Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flowmeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Respiratory analysis system and method

A system is described for monitoring the respiratory process in which the gas flow rate and the frequency of respiration and expiration cycles can be determined on a real time basis. A face mask is provided with one-way inlet and outlet valves where the gas flow is through independent flowmeters and through a mass spectrometer. The opening and closing of a valve operates an electrical switch, and the combination of the two switches produces a low frequency electrical signal of the respiratory inhalation and exhalation cycles. During the time a switch is operated, the corresponsing flowmeter produces electric pulses representative of the flow rate; the electrical pulses being at a higher frequency than that of the breathing cycle and combined with the low frequency signal. The high frequency pulses are supplied to conventional analyzer computer which also receives temperature and pressure inputs and computes mass flow rate and totalized mass flow of gas. From the mass spectrometer, components of the gas are separately computed as to flow rate. The electrical switches cause operation of up-down inputs of a reversible counter. The respective up and down cycles can be individually monitored and combined for various respiratory measurements.

Liu, F. F.↗

The feasibility of a fluidic respiratory flow meter

A study was undertaken to determine the feasibility of adapting a fluidic airspeed sensor for use as a respiratory flowmeter. A Pulmonary Function Testing Flowmeter was developed which should prove useful for mass screening applications. The fluidic sensor threshold level was not reduced sufficiently to permit its adaptation to measuring the low respiratory flow rates encountered in many respiratory disorders.

Neradka, V. F.↗

Development of a prototype fluid volume measurement system

The research is reported in applying the axial fluid temperature differential flowmeter to a urine volume measurement system for space missions. The fluid volume measurement system is described along with the prototype equipment package. Flowmeter calibration, electronic signal processing, and typical void volume measurements are also described.

Poppendiek, H. F.↗

Ultrasonic Doppler measurement of renal artery blood flow

Implantable pulsed Doppler ultrasonic flowmeter development has resulted in designs for application to the aortas of dogs and humans, and to human renal and coronary arteries. A figure of merit was derived for each design, indicating the degree of its precision. An H-array design for transcutaneous observation of blood flow was developed and tested in vitro. Two other simplified designs for the same purpose obviate the need to determine vessel orientation. One of these will be developed in the next time period. Techniques for intraoperative use and for implantation have had mixed success. While satisfactory on large vessels, higher ultrasonic frequencies and alteration of transducer design are required for satisfactory operation of pulsed Doppler flowmeters with small vessels.

Source record↗

Advanced Recording and Preprocessing of Physiological Signals

The measurement of the volume flow-rate of blood in an artery or vein requires both an estimate of the flow velocity and its spatial distribution and the corresponding cross-sectional area. Transcutaneous measurements of these parameters can be performed using ultrasonic techniques that are analogous to the measurement of moving objects by use of a radar. Modern digital data recording and preprocessing methods were applied to the measurement of blood-flow velocity by means of the CW Doppler ultrasonic technique. Only the average flow velocity was measured and no distribution or size information was obtained. Evaluations of current flowmeter design and performance, ultrasonic transducer fabrication methods, and other related items are given. The main thrust was the development of effective data-handling and processing methods by application of modern digital techniques. The evaluation resulted in useful improvements in both the flowmeter instrumentation and the ultrasonic transducers. Effective digital processing algorithms that provided enhanced blood-flow measurement accuracy and sensitivity were developed. Block diagrams illustrative of the equipment setup are included.

Bentley, P. B.↗

Doppler instrumentation for measuring blood velocity and flow

Doppler ultrasonic blood flowmeters are reviewed in detail. The importance of measurement accuracy for transcutaneous flowmeters and their clinical application is stressed. Doppler imaging was combined with conventional pulse echo imaging, and diagnostic information was extracted from flow signals. The range and extent of applications of Doppler instruments was also presented.

Gill, R. W.↗

Technique for Measuring Gas Conversion Factors

Technique for measuring calibration conversion factors for hydrocarbon mass flowmeters applied to widely used type of commercial thermal mass flowmeter for hydrocarbon gases. Values of conversion factors for two common hydrocarbons measured using this technique in good agreement with empirical values cited by manufacturer. Similar agreement expected for all other hydrocarbons. Technique based on Nernst theorem for matching partial pressure of oxygen in combustion product gases with that in normal air. Simple, quick, and relatively safe, particularly for toxic/poisonous hydrocarbons.

Singh, J. J.↗

Measurement of viscosity of gaseous mixtures at atmospheric pressure

Coefficients of viscosity of various types of gas mixtures, including simulated natural-gas samples, have been measured at atmospheric pressure and room temperature using a modified capillary tube method. Pressure drops across the straight capillary tube section of a thermal mass flowmeter were measured for small, well-defined, volume flow rates for the test gases and for standard air. In this configuration, the flowmeter provides the volumetric flow rates as well as a well-characterized capillary section for differential pressure measurements across it. The coefficients of viscosity of the test gases were calculated using the reported value of 185.6 micro P for the viscosity of air. The coefficients of viscosity for the test mixtures were also calculated using Wilke's approximation of the Chapman-Enskog (C-E) theory. The experimental and calculated values for binary mixtures are in agreement within the reported accuracy of Wilke's approximation of the C-E theory. However, the agreement for multicomponent mixtures is less satisfactory, possible because of the limitations of Wilkes's approximation of the classical dilute-gas state model.

Singh, J. J.↗

Measuring Viscosities of Gases at Atmospheric Pressure

Variant of general capillary method for measuring viscosities of unknown gases based on use of thermal mass-flowmeter section for direct measurement of pressure drops. In technique, flowmeter serves dual role, providing data for determining volume flow rates and serving as well-characterized capillary-tube section for measurement of differential pressures across it. New method simple, sensitive, and adaptable for absolute or relative viscosity measurements of low-pressure gases. Suited for very complex hydrocarbon mixtures where limitations of classical theory and compositional errors make theoretical calculations less reliable.

Singh, Jag J.↗

Method and device for determining heats of combustion of gaseous hydrocarbons

A method and device is provided for a quick, accurate and on-line determination of heats of combustion of gaseous hydrocarbons. First, the amount of oxygen in the carrier air stream is sensed by an oxygen sensing system. Second, three individual volumetric flow rates of oxygen, carrier stream air, and hydrocrabon test gas are introduced into a burner. The hydrocarbon test gas is fed into the burner at a volumetric flow rate, n, measured by a flowmeter. Third, the amount of oxygen in the resulting combustion products is sensed by an oxygen sensing system. Fourth, the volumetric flow rate of oxygen is adjusted until the amount of oxygen in the combustion product equals the amount of oxygen previously sensed in the carrier air stream. This equalizing volumetric flow rate is m and is measured by a flowmeter. The heat of combustion of the hydrocrabon test gas is then determined from the ratio m/n.

Singh, Jag J.↗

Seal testing of large diameter rocket motors

This investigative program examines leakage testing of elastomeric O-ring seals for a solid rocket casing and provides direction towards an improved nondestructive postassembly test. It also details test equipment for the Space Shuttle systems solid rocket boosters (SRB). The results are useful to designers of hardware for pressure containment vessels which use O-ring seals. Using several subscale seal and groove configuration test fixtures equipped with either two or three O-ring seals in series, seal integrity is investigated with both a pressure decay and flowmeter methods. Both types of test equipment adequately detect the practical range of expected seal leak rates of 1 to 0.0001 sccs. The flowmeter leak test equipment appears to reduce testing time substantially. Limited seal leakage testing is performed on full-sized rocket motor segment seals, a pre-Challenger short stack, providing comparison of bore seals to test specimen bore and face seals. The conclusions are that seal reliability, verified via a performance pressure test, can be affected by temperature, quantity of grease, test pressure, and seal pressure load direction. Potential seal failure scenarios including contamination, seal damage, and sealing surface damage are discussed. Recommendations are made for an improved test procedure.

Moore, N. B.↗

Development of Conceptual Lead Cartridge Design to Perform Irradiation Experiments in VTR

This paper seeks to introduce the latest design of the Extended Length Test Assembly–Cartridge Lead (ELTA-CL) with associated thermal-hydraulic (TH) assessment and related experiment activities to support the critical component development performed by the ELTA-CL team (Los Alamos National Laboratory, Westinghouse Electric Company, and the University of New Mexico). The goal of the ELTA-CL program is to develop and validate an experimental capability to perform irradiation experiments in the Versatile Test Reactor (VTR) addressing Lead Fast Reactor (LFR) technology gaps, in support of the commercial development of advanced lead-cooled fast reactor concepts. Through a design maturation process and parametric study, a conceptual design is proposed to meet the requirements for material and corrosion testing. Thermal-hydraulic characteristics for the conceptual design at desired operating conditions are assessed with systems-level (one-dimensional) and computational fluid dynamics (three-dimensional) simulations. Along with the conceptual design work, experimental activities for the development of critical components such as the pump and flowmeter are undertaken. From both the modeling study and the experimental results, the design requirements of the Phase 1 ELTA-CL (e.g., 500°C and 2 m/s) are achievable with the current conceptual design. Additional design improvements and safety assessments at both steady-state and transient conditions for the final ELTA-CL design will be pursued.

42 ENGINEERING↗

Thermal Hydraulic Experimental Test Article - Report of THETA Commissioning for METL Testing

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, [1], further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned before installing into METL test vessel #4. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fabrication and Preliminary Demonstration of Microwave Resonant Cavity Transducer Performance

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. We have developed an initial design for proof-of-principle testing of the flow sensor performance in microwave K-band. A cylindrical resonator prototype was fabricated from brass for initial tests in water. The cavity size is matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed, consisting of a piping Tee with bulkhead WR-42 microwave waveguide installed in leak-proof design. In the test article, the cylindrical cavity is positioned in the center of the pipe. A microwave waveguide circulator was installed in the setup to suppress microwave reflections at the cavity entrance. Preliminary spectral characterization of cavity spectral response was performed with microwave VNA. Applying mechanical pressure to cavity membrane showed a measurable shift in the microwave resonant frequency. We also investigate mechanical integrity of the flowmeter’s membrane through computer simulations. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Flow Sensor Test Article (F-STAr) - Status Report for FY2021

This report will review updates on the status of F-STAr. First, the report will describe a general overview of the test article and how each component interacts. Then, each main component will be discussed in a deep dive section which will review the design and other relevant details. F-STAr components which are discussed in more detail include the 120 GPM-pump, the support structure and test sections, 5 kW-heater, the 2 kW-cooler and cooling system, and the submersible flowmeter. Finally, this report will conclude with a brief recap and a bulleted outline of the path moving forward.

42 ENGINEERING↗

First Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the sensor was initially investigated with analytical derivations and with COMSOL RF Module computer simulations of resonant frequency spectral shift due to uniform load. We also investigated the mechanical integrity of the flowmeter’s membrane through analytical modelling and COMSOL Structural Mechanics Module computer simulations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the material’s yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure. Using results from models, we have developed an initial design for a microwave K-band sensor. A cylindrical resonator prototype was fabricated from brass for the initial tests. The external dimensions of the cavity are matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed consisting of a piping Tee with a bulkhead WR-42 microwave waveguide installed in a leak-proof assembly. A microwave waveguide circulator was installed in the setup to suppress the effect of reflections at the cavity entrance by increasing the isolation between the input and the output port. Preliminary spectral characterization of cavity spectral response was performed with a portable PXIe chassis microwave VNA with a custom GUI. Preliminary dry tests of the transducer response were conducted with a set of calibrated weights. Transducer frequency shift was shown to be monotonically increasing with increasing pressure. The next steps will involve investigation of the transducer performance for water flow sensing.

42 ENGINEERING↗

Flow Sensor Test Article (F-STAr) (Design and Fabrication Status Report)

The Flow Sensor Test Article (F-STAr) is a test article currently under construction for the Mechanisms Engineering Test Loop (METL). F-STAr was designed to provide high sodium flowrate capabilities for sensor calibration, component testing, and fluid studies. Figure 1 shows two solid model views of the new test article. F-STAr includes a high-capacity pump that can provide a nominal flowrate of 120 GPM; a test section support structure that can accommodate a wide array of sub-test articles and their instrumentation; and finally, a heating and cooling system to aid in controlling the testing environment. Initially, F-STAr will be configured to test liquid metal flow sensors, specifically field shift sensors like the Eddy Current Flow Sensors (ECFS) based on the RDT C4-7T standard. To test these sensors, two test sections were designed that attempt to model Sodium Fast Reactor (SFR) outlet conditions. Figure 2 shows models of the “Full-Scaled Test Section” (FSTS) that represents a generic SFR fuel handling socket and a “Pseudo-Scaled Test Section” (PSTS) that represents a generic array of scaled fuel handling sockets. While F-STAr will be configured to test ECFS’s, it can also be outfitted to meet other experimental needs. For example, F-STAr could be setup with a test section that includes a fluidic diode or a component test investigating the performance of hydrodynamic bearings. Other test sections include studies of sodium thermal hydraulics like thermal striping. Overall, F-STAr is a flexible test article designed to accommodate many needs. This report will provide a status update on the design and construction of F-STAr. Manufacturing of all components has commenced, and several components have already been completed. These components include the pump and test section assembly stand. Other components, such as the heater, have been completed but were rejected due to the vendor not meeting the requirements of the purchase order. Lastly, the submersible flowmeter and main flange components are under construction, and their status will be reviewed in this report. Overall, most of the F-STAr components and parts will be completed by the end of September 2022.

42 ENGINEERING↗

Flow Sensor Test Article (F-STAr) - Assembly and Water Testing Report

The Flow Sensor Test Article (F-STAr) is a new test article under development for the Mechanisms Engineering Test Loop (METL) facility at Argonne National Laboratory. F-STAr’s purpose is to provide sodium submersible, high flowrate testing capabilities for the development of sensors, components, fluid studies and more. This report will provide a status update on the assembly and initial qualification testing of F-STAr. All components have been manufactured and received. Some modifications to these components were made to support minor changes in the test article design. Additionally, the power distribution, and data acquisition and control enclosures were designed, completed, and tested along with the control system software. Furthermore, initial qualification testing was completed in water. Finally, the F-STAr submersible Electromagnetic Flowmeter (EMFM) was completed and calibrated in flowing sodium.

42 ENGINEERING↗