Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fixed grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Long-Duration High-Resolution Large-Eddy Simulations of Hurricane Laura (2020) for Infrastructure Design

This dataset provides long-duration large-eddy simulations (LES) of Hurricane Laura (2020), capturing the turbulent boundary-layer wind field during the storm's passage at horizontal grid spacings of 55.55 m and 10 m. Hurricane Laura made landfall as a Category 4 storm in southwestern Louisiana at 06:00 UTC on 27 August 2020, producing widespread damage to coastal infrastructure. The simulations characterize the spatial and temporal variability of the turbulent wind at heights spanning the lowest 300 m of the boundary layer, throughout the approach and passage of the storm's eyewall over a fixed location. To resolve the spatial heterogeneity of wind and turbulence conditions across the storm, seven independent refined LES runs are performed at radial locations spanning the storm relative to its direction of motion. The refinement positions are defined on a normalized radial coordinate r ̂=r/R, where R≈21 km is Laura's radius of maximum wind, and lie between r ̂=-1.5 and r ̂=+1.5 in ∆r ̂=0.5 increments along a line perpendicular to the storm's track at the midpoint of the simulation. Negative r ̂ corresponds to locations south-southwest of the storm center and positive r ̂ to locations north-northeast. The dataset is segmented into seven radial refinement groups.

17 WIND ENERGY↗

Temporal Coarse Graining for Classical Stochastic Noise in Quantum Systems

Simulations of quantum systems with Hamiltonian classical stochastic noise can be challenging when the noise exhibits temporal correlations over a multitude of time scales, such as for 1/f noise in solid-state quantum information processors. Here we present an approach for simulating Hamiltonian classical stochastic noise that performs temporal coarse-graining by effectively integrating out the high-frequency components of the noise. We focus on the case where the stochastic noise can be expressed as a sum of Ornstein-Uhlenbeck processes. Temporal coarse-graining is then achieved by conditioning the stochastic process on a coarse realization of the noise, expressing the conditioned stochastic process in terms of a sum of smooth, deterministic functions and bridge processes with boundaries fixed at zero, and performing the ensemble average over the bridge processes. For Ornstein-Uhlenbeck processes, the deterministic components capture all dependence on the coarse realization, and the stochastic bridge processes are not only independent but taken from the same distribution with correlators that can be expressed analytically, allowing the associated noise propagators to be precomputed once for all simulations. This combination of noise trajectories on a coarse time grid and ensemble averaging over bridge processes has practical advantages, such as a simple concatenation rule, that we highlight with numerical examples.

Albash, Tameem [Sandia National Lab. (SNL-NM), Alb↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Climate change-resilient snowpack estimation in the Western United States

Abstract In the 21st century, warmer temperatures and changing atmospheric circulation will likely produce unprecedented changes in Western United States snowfall 1–3 , with impacts on the timing, amount, and spatial patterns of snowpack 4–7 . The ~900 snow pillow stations are indispensable to water resource management by measuring snow-water equivalent (SWE) 8,9 in strategic but fixed locations 10,11 . However, this network may not be impacted by climate change in the same way as the surrounding area 12 and thus fail to accurately represent unmeasured locations; climate change thereby threatens our ability to measure the effects of climate change on snow. In this work, we show that maintaining the current peak SWE estimation skill is nonetheless possible. We find that explicitly including spatial correlations—either from gridded observations or learned by the model—improves skill at predicting distributed snowpack from sparse observations by 184%. Existing artificial intelligence methods can be useful tools to harness the many available sources of snowpack information to estimate snowpack in a nonstationary climate.

54 ENVIRONMENTAL SCIENCES↗

The GGCMI Phase 2 emulators: global gridded crop model responses to changes in CO 2 , temperature, water, and nitrogen (version 1.0)

Statistical emulation allows combining advantageous features of statistical and process-based crop models for understanding the effects of future climate changes on crop yields. We describe here the development of emulators for nine process-based crop models and five crops using output from the Global Gridded Model Intercomparison Project (GGCMI) Phase 2. The GGCMI Phase 2 experiment is designed with the explicit goal of producing a structured training dataset for emulator development that samples across four dimensions relevant to crop yields: atmospheric carbon dioxide (CO2) concentrations, temperature, water supply, and nitrogen inputs (CTWN). Simulations are run under two different adaptation assumptions: that growing seasons shorten in warmer climates, and that cultivar choice allows growing seasons to remain fixed. The dataset allows emulating the climatological-mean yield response of all models with a simple polynomial in mean growing-season values. Climatological-mean yields are a central metric in climate change impact analysis; we show here that they can be captured without relying on interannual variations. In general, emulation errors are negligible relative to differences across crop models or even across climate model scenarios; errors become significant only in some marginal lands where crops are not currently grown. We demonstrate that the resulting GGCMI emulators can reproduce yields under realistic future climate simulations, even though the GGCMI Phase 2 dataset is constructed with uniform CTWN offsets, suggesting that the effects of changes in temperature and precipitation distributions are small relative to those of changing means. The resulting emulators therefore capture relevant crop model responses in a lightweight, computationally tractable form, providing a tool that can facilitate model comparison, diagnosis of interacting factors affecting yields, and integrated assessment of climate impacts.

54 ENVIRONMENTAL SCIENCES↗

Large-Scale Simulation of Regional Demand Flexibility Implementation and Customer Economic Impact

The Distribution System Operator with Transactive (DSO+T) study conducted a large-scale simulation of over 60,000 customers in a region the size of Texas to demonstrate the effective coordination of distributed energy resources (DERs) in commercial and residential buildings. The integrated simulation included both the bulk (wholesale generation and transmission) and distribution systems. The DERs (including batteries, electric vehicles, air conditioning, and water heaters) participated in a transactive energy retail market that was integrated into an existing competitive wholesale market. The engineering and economic performance of the resulting demand flexibility was evaluated over annual simulations for both moderate and high renewable generation scenarios. A detailed parametric cost model was developed to enable detailed economic analysis of key stakeholders. In addition, fixed and dynamic customer tariffs were designed and applied to the customer population. This allowed the impact on annual customer bills to be analyzed for various building types (residential versus commercial; single- versus multi-family). This paper presents results showing the relative flexibility of batteries, electric vehicles, and building loads throughout the year and under different renewable scenarios. This feeds a detailed breakdown of the impact this flexibility has on the operating costs of the grid and the resulting net economic benefit. Finally, the study showed that practically all customer classes (including non-participating customers) save money under the proposed demand flexibility scheme. The study found overall net annual economic savings of $3.3-5.0B for a region the size of Texas equating to average customer bill savings of 10-16%.

Reeve, Hayden M.↗

Scalable fabrication of an array-type fixed-target device for automated room temperature X-ray protein crystallography

X-ray crystallography is one of the leading tools to analyze the 3-D structure, and therefore, function of proteins and other biological macromolecules. Traditional methods of mounting individual crystals for X-ray diffraction analysis can be tedious and result in damage to fragile protein crystals. Furthermore, the advent of multi-crystal and serial crystallography methods explicitly require the mounting of larger numbers of crystals. To address this need, we have developed a device that facilitates the straightforward mounting of protein crystals for diffraction analysis, and that can be easily manufactured at scale. Inspired by grid-style devices that have been reported in the literature, we have developed an X-ray compatible microfluidic device that can be used to trap protein crystals in an array configuration, while also providing excellent optical transparency, a low X-ray background, and compatibility with the robotic sample handling and environmental controls used at synchrotron macromolecular crystallography beamlines. At the Stanford Synchrotron Radiation Lightsource (SSRL), these capabilities allow for fully remote-access data collection at controlled humidity conditions. Furthermore, we have demonstrated continuous manufacturing of these devices via roll-to-roll fabrication to enable cost-effective and efficient large-scale production.

chemical engineering↗

Intelligent Control of Thermal Energy Storage in the Manufacturing Sector for Plant-Level Grid Response

Industrial facilities are seeking new strategies that help in providing savings mechanisms for demand charges. Demand charges are the charges incurred by industrial facilities as a result of power usage. Thermal energy storage has advanced significantly with lots of new applications, garnering the interest of many industrial facilities. These applications could be used to shave the industrial facilities’ peak electric demand and reduce their demand charges. This paper aims to demonstrate the efficacy of thermal energy storage in reducing demand charges and highlight new developments in the integration of smart control systems with thermal energy storage. The study compares energy consumption and peak demand for a facility equipped with and without thermal energy storage tanks using a fixed schedule for charging and discharging. Additionally, the paper examines the impact of incorporating a smart controller to determine when to charge and discharge the tank based on the facility’s real-time power usage and a given setpoint. The results indicate cost savings from the use of thermal energy storage tanks under two proposed scenarios, reflected in the reduced cost of power consumption for the studied facility. The incorporation of a smart controller with the thermal energy storage tank in the facility studied could provide estimated savings of 3.3% per year of power consumption charges, without considering the contribution of any incentives. The estimated savings provided by the fixed schedule scenario are 2.7% per year.

25 ENERGY STORAGE↗

Technoeconomic Design Optimization for Fast Reactors. Part II: Impact of Technoeconomic Constraints on Optimal Design

There is a current drive toward optimizing reactors, particularly small/micro reactors to minimize cost and maximize performance. Previous work has investigated the development of technoeconomic workflows for the design optimization of pool-type fast reactors that aim to deploy into district energy grids. Initial scoping studies verified that the workflow was capable of capturing design trends throughout a variety of design configurations and problem formulations while remaining sufficiently flexible. In this paper, this methodology is applied to understand how cost functions and technoeconomic constraints can drive optimal reactor design. Specifically, the UPu10Zr-fueled fast reactor model from Part I is adapted to include changes in the fissile content limits, control rod worth limits, control rod drive cost, and assumed fuel form. In the case of constraint relaxation at fixed power (fissile content and control rod worth limits), cost sensitivities of 5% to 10% were uncovered. Multi-objective optimization at varying reactor power levels with individualized control rod drives for each assembly (as opposed to one operational and one safety drive) increased cost by $\$10$ to $\$25$ million and substantially altered the optimal core geometry, favoring geometries with substantially fewer control rod placements relative to baseline optimization. Finally, a multi-objective optimization was performed at varying power levels with the fuel form overhauled to metallic, high-assay low-enriched uranium–based U10Zr with more refined fuel cost models. In the case of uranium fueling, the costs increased by at least $50 million relative to the baseline case. Furthermore, economic fuel zoning and lower reactivity swing cores were recovered. Each case serves to demonstrate the value of applying technoeconomic workflows to initial reactor design scoping studies to better understand the trade-off for a proposed concept between different design options.

Argonne Reactor Computation (ARC) codes↗

Estimating the impacts of natural gas power generation growth on solar electricity development: PJM's evolving resource mix and ramping capability

Abstract Expansion of distributed solar photovoltaic (PV) and natural gas‐fired generation capacity in the United States has put a renewed spotlight on methods and tools for power system planning and grid modernization. This article investigates the impact of increasing natural gas‐fired electricity generation assets on installed distributed solar PV systems in the Pennsylvania–New Jersey–Maryland (PJM) Interconnection in the United States over the period 2008–2018. We developed an empirical dynamic panel data model using the system‐generalized method of moments (system‐GMM) estimation approach. The model accounts for the impact of past and current technical, market and policy changes over time, forecasting errors, and business cycles by controlling for PJM jurisdictions‐level effects and year fixed effects. Using an instrumental variable to control for endogeneity, we concluded that natural gas does not crowd out renewables like solar PV in the PJM capacity market; however, we also found considerable heterogeneity. Such heterogeneity was displayed in the relationship between solar PV systems and electricity prices. More interestingly, we found no evidence suggesting any relationship between distributed solar PV development and nuclear, coal, hydro, or electricity consumption. In addition, considering policy effects of state renewable portfolio standards, net energy metering, differences in the PJM market structure, and other demand and cost‐related factors proved important in assessing their impacts on solar PV generation capacity, including energy storage as a non‐wire alternative policy technique. This article is categorized under: Photovoltaics > Economics and Policy Fossil Fuels > Climate and Environment Energy Systems Economics > Economics and Policy

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Adaptive cold-load pickup considerations in 2-stage microgrid unit commitment for enhancing microgrid resilience

In an extended main grid outage spanning multiple days, load shedding serves as a critical mechanism for islanded microgrids to maintain essential power and energy reserves that are indispensable for fulfilling reliability and resiliency mandates. However, using load shedding for such purposes leads to increasing occurrence of cold load pickup (CLPU) events. Here, this study presents an innovative adaptive CLPU model that introduces a method for determining and incorporating parameters related to CLPU power and energy requirements into a two-stage microgrid unit commitment (MGUC) algorithm. In contrast to the traditional fixed-CLPU-curve approach, this model calculates CLPU duration, power, and energy demands by considering outage durations and ambient temperature variations within the MGUC process. By integrating the adaptive CLPU model into the MGUC problem formulation, it allows for the optimal allocation of energy resources throughout the entire scheduling horizon to fulfill the CLPU requirements when scheduling multiple CLPU events. The performance of the enhanced MGUC algorithm considering CLPU needs is assessed using actual load and photovoltaic (PV) data. Simulation results demonstrate significant improvements in dispatch optimality evaluated by the amount of load served, customer comfort, energy storage operation, and adherence to energy schedules. These enhancements collectively contribute to reliable and resilient microgrid operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing Active Distribution Systems Resilience by Fully Distributed Self-Healing Strategy

Distributed restoration can exploit smart grid technologies to enhance the resilience of active distribution networks toward a self-healing smart grid. However, the large number of decision variables, especially the binary ones for reconfiguration, bring challenges to developing scalable distributed distribution service restoration (DDSR) strategies. This paper proposes a fully distributed solution procedure based on the alternating direction method of multipliers (ADMM) for mixed-integer programming problems and applies to develop the DDSR framework. The method consists of relax-drive-polish phases, 1) relaxing binary variables, and applying the convex ADMM as a warm start; 2) driving the solutions toward Boolean values through a proximal operator; 3) fixing the obtained binding binary variables and solving the rest of the problem to polish results and achieve a high-quality suboptimal solution. Then, an autonomous clustering strategy and consensus ADMM are integrated with the proposed method to realize the fully distributed cluster-based framework of DDSR. This framework can first determine DER scheduling and switch status for reconfiguration to energize the out-of-service areas from local faults, and then provide the load restoration solution in a distributed manner for total blackouts in large-scale distribution networks. Furthermore, the effectiveness and scalability of the proposed DDSR framework are demonstrated through testing on the IEEE 123-node, IEEE 8500-node, and synthetic 100k-node test feeders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Dry Cooler Air-Side Performance on a sCO2 Power Cycle for a CSP Application

Uncertainty around the design and control of the supercritical CO2 power cycle must be reduced before this technology can be implemented for large-scale grid support. To better understand the day-to-day performance of an sCO2 cycle, off-design performance calculations must be included for all power block components, and performance assumptions must be removed. This study has expanded the modeled scope to include the air-side performance for the dry cooler and has incorporated discretized heat transfer calculations for both streams through the pre-cooler to better predict off-design performance. This study considered a recompression Brayton cycle in a concentrating solar power application. The cycle model utilized fixed sCO2 turbomachinery maps for the main compressor, recompressor, and expander operating to supply approximately 10 MW gross at the design point. Fixed vendor-supplied fan curves were used to calculate the air-side performance of the dry cooler. The primary heater was modeled considering both the sCO2 and heat transfer fluid streams. Off-design performance was predicted for an ambient temperature range of 0-55℃, a HTF temperature range of 705-735℃, and a HTF mass flow range of 50-105% of the design point value. To understand the importance of modeling the air-side performance, the cycle off-design performance was also calculated using a constant CO2 outlet temperature assumption and a constant approach temperature assumption for the dry cooler. Results show that using these assumptions can significantly alter the power output and cycle efficiency predictions.

14 SOLAR ENERGY↗

Feature-Based PMU Event Classification under Variable PMU Participation and Overlapping Events

Danovo Energy Solution's presented its paper named: Feature-Based PMU Event Classification under Variable PMU Participation and Overlapping Events at the 2026 Georgia Tech Fault & Disturbance Analysis Conference. The full paper can be found at OSTI ID# 3169150 Paper Abstract—Phasor Measurement Units (PMUs) stream time synchronized, high-resolution measurements from the grid, enabling data-driven techniques for event detection and classification. Accurate event classification improves grid reliability and stability. Events can be detected by varying numbers of PMUs and exhibit different durations depending on the event type. This variability challenges standard classifiers that require uniform input sizes. Moreover, multiple events may coincide, which increases classification complexity. Standard classifiers assign each instance to the class with the highest predicted probability, whereas overlapping events may exhibit comparable probabilities across multiple classes. In this study, to handle data size variability, we extract a wide range of time–frequency domain features from all available PMUs for each event into a fixed-length vector, facilitating the application of standard machine learning classifiers, including Random Forest, XGBoost, LightGBM, Support Vector Machine, and Multilayer Perceptron. To account for overlapping events, a probabilistic post-processing step is applied. For a given data instance, if multiple predicted class probabilities exceed 30% and the differences between them are less than 10%, the event is assigned to multiple classes. Experiments using real-world PMU data demonstrate that the Random Forest and XGBoost models achieve the highest accuracy, while the proposed post-processing method yields perfect classification performance on external unseen test sets.

Nematirad, Reza [Danova Energy Solutions]↗

Feature-Based PMU Event Classification under Variable PMU Participation and Overlapping Events

This paper is the basis for a presentation help at the 2026 Georgia Tech Fault & Disturbance Analysis Conference, which can be found at OSTI # 3168287 Paper Abstract—Phasor Measurement Units (PMUs) stream time synchronized, high-resolution measurements from the grid, enabling data-driven techniques for event detection and classification. Accurate event classification improves grid reliability and stability. Events can be detected by varying numbers of PMUs and exhibit different durations depending on the event type. This variability challenges standard classifiers that require uniform input sizes. Moreover, multiple events may coincide, which increases classification complexity. Standard classifiers assign each instance to the class with the highest predicted probability, whereas overlapping events may exhibit comparable probabilities across multiple classes. In this study, to handle data size variability, we extract a wide range of time–frequency domain features from all available PMUs for each event into a fixed-length vector, facilitating the application of standard machine learning classifiers, including Random Forest, XGBoost, LightGBM, Support Vector Machine, and Multilayer Perceptron. To account for overlapping events, a probabilistic post-processing step is applied. For a given data instance, if multiple predicted class probabilities exceed 30% and the differences between them are less than 10%, the event is assigned to multiple classes. Experiments using real-world PMU data demonstrate that the Random Forest and XGBoost models achieve the highest accuracy, while the proposed post-processing method yields perfect classification performance on external unseen test sets.

Nematirad, Reza [Danovo Energy Solutions]↗

Quantifying the Solar Energy Resource for Puerto Rico

After Hurricane Maria, multiple U.S. Department of Energy laboratories studied the state of the electric grid in Puerto Rico and analyzed grid resilience and grid integration of renewable energy. As part of the work done at the National Renewable Energy Laboratory, researchers created new solar resource data, conducted a technical potential and supply curve analysis, and studied the interannual variability of the solar resource. A new methodology was developed to downscale solar resource data from the National Solar Radiation Data Base (NSRDB) from a 4-km x 4-km spatial and 30-minute temporal resolution to a 2 km x 2 km and 5-minute resolution. This methodology primarily used simple physical principles to develop high-resolution cloud properties which were then used to compute solar radiation. The high-resolution datasets were validated against ground measurements and the error metrics were found to be similar to the original lower resolution dataset. Using 20 years of downscaled data from the NSRDB multi-year capacity factors for photovoltaics (PV) were developed for both single-axis tracking and fixed latitude-tilt configurations. Use of the multi-year data provides the ability to understand variability in capacity factors due to variability in weather over a long period of time. For Puerto Rico the coastal regions were found to have significant higher capacity factors than inland. Using land-use and terrain information a technical potential analysis was conducted for Puerto Rico. This analysis restricted single PV plant development to a maximum of 100 MW nameplate capacity. The nameplate capacity for each municipality were then determined. Based on our assumptions, 56 of the 78 total municipalities of Puerto Rico contain some level of solar capacity. Most of the interior municipalities did not have any capacity because of the geographic exclusions used in this study. The lowest capacity for a PV plant observed in a municipality was 10 MW. The maximum capacity within a county was 2,000 MW. Further a supply curve analysis was conducted by taking the results of the technical potential and quantifying system and transmission costs. The levelized cost of energy (LCOE) was calculated for each theoretical PV plant site, and the levelized cost of transmission was added to the LCOE to produce a total cost estimate for each site. The results of the supply curve analysis allow for a relative comparison of the cost for integrating new PV capacity into the grid. This analysis indicates that cheaper total LCOE sites tend to be larger in capacity. The total capacity in this study was found to be far beyond the maximum peak load for the island. However, this study does not consider the economic and market potential for development. The cumulative capacity presented in this study assumes that the best locations are developed first and ignores the complex decision paths for new power plant development. Therefore, this analysis can only be treated as illustrative. Finally this study investigates the impact of inter-annual variability of resource using a variety of metrices including probability of exceedance and variation in capacity factor and LCOE. This study demonstrates that the capacity factor or LCOE could vary by over 10% year to year. This clearly indicates the risks involved in using any particular year of data and clearly points to the use of multi-year data to reduce some of the risks related to variability in weather.

14 SOLAR ENERGY↗

Influence of Lake Ice Biases in Reanalysis Data on Downscaled Climate Simulations over the Great Lakes Region

This data package contains observation-based and model-simulated datasets (all provided in NetCDF format) for evaluating how wintertime lake-ice representation affects regional weather and climate over the Laurentian Great Lakes (freshwater lake ecosystem) during the high–ice-cover winter of 2009. The observational component includes: (1) Stage IV gridded precipitation at 4 km, hourly resolution for January–February 2009 over the Great Lakes region (radar–gauge multisensor precipitation analyses); (2) Great Lakes Surface Environmental Analysis (GLSEA) satellite-derived lake-ice coverage at 1.3 km, daily resolution for the 2009 winter months, providing ice coverage over Lakes Superior, Michigan, Huron, Erie, and Ontario; and (3) in situ measurements at the Standard Rock site on Lake Superior from the Great Lakes Evaporation Network (GLEN) at hourly resolution, including near-surface atmospheric variables and sensible and latent heat fluxes (air–lake exchange) at a fixed point location. The modeling component provides corresponding fields from two simulations, both archived at 4 km, hourly resolution: a standalone Weather Research Forecasting model (WRF) run driven by the European Centre for Medium-Range Weather Forecasts (ECMWF) Reanalysis 5 (ERA5), and a two-way coupled model using WRF and the Finite Volume Community Ocean Model (WRF-FVCOM, a 3-D hydrodynamic lake model). These outputs include variables relevant to air–lake interaction and lake-effect processes (e.g., near-surface temperature, humidity, wind, precipitation, and surface turbulent fluxes), enabling direct comparison with the observational datasets. Users can analyze and visualize these NetCDF files with common tools such as Python (e.g., xarray, netCDF4, numpy, pandas), NCO/CDO, Panoply, or ncview; NetCDF variables can also be converted to other formats (e.g., CSV, GeoTIFF) using these utilities.

EARTH SCIENCE > ATMOSPHERE > ATMOSPHERIC TEMPERATU↗

Deep Reinforcement Learning-Based Control of Energy Storage for Interarea Oscillation Damping

With the increasing electricity consumption and lack of transmission investment, today's power systems are operated much closer to their limits, raising concerns of inter-area oscillations that deteriorate the system stability. Here, this article presents a novel energy storage placement and control approach for enhanced damping of interarea oscillations. Combining the residual analysis and dominant mode analysis, we are able to identify the advantageous locations for placing energy storage that achieve improved damping performance. To overcome the challenges, such as fixed control parameters and insufficient damping, we propose to use a deep reinforcement learning-based approach for energy storage control. A state-of-the-art guided surrogate-gradient-based evolutionary strategy is used to train a learning agent in a robust, efficient, and reproducible manner. Parallel computing is also adopted to speed up the training process. The proposed strategy has been tested on both medium and large-scale systems. The proposed methods have demonstrated their effectiveness in mitigating various interarea oscillations within a timeframe of 20 s, thereby averting system collapse and enhancing power grid stability effectively.

25 ENERGY STORAGE↗