Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire Containment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Fire- and Heat-Resistant Laminating Resins

Imide compounds containing phosphourus thermally polymerized. New maleimido- or citraconimido-end-capped monomers, have relatively low melting temperatures, polymerized at moderate temperatures to rigid bisimide resins without elimination of volatiles. Monomers dissolve in such solvents as methyl ethyl ketone, acetone, and tetrahydrofuran, suitable and perferred as "varnish solvents" for composite fabrication. Low melting points of these componds allow use as adhesives without addition of solvents.

Kourtides, Demetrius A.↗

PFAS Removal by Ion Exchange Resins: Background and Knowledge Gaps with Respect to the Hanford Site

Per- and polyfluoroalkyl substances (PFAS) have been a rising concern for the past two decades, with the United States Department of Defense and Environmental Protection Agency investing millions of dollars in research into remediation and clean-up technologies. Due to the environmental persistence, toxicity, biological uptake, and ongoing changes in both federal and state regulatory space, understanding the fate and transport of PFAS compounds has been of growing concern to the US Department of Energy (DOE). The DOE’s Hanford Site is investigating historical use of PFAS and will be doing site characterization for PFAS. Thus, PFAS have not yet been identified as a contaminant concern in regulatory documents. Based on historical records that mention the discharge of aqueous film-forming foam containing PFAS and having on-site fire stations (a risk factor for PFAS contamination), it seems likely that environmental releases of PFAS may have occurred. Pump and treat (P&T) remediation is the selected remedy for multiple groundwater contaminant plumes at Hanford. These P&T systems use ion exchange (IX) as a component of aboveground treatment, with the specific resins depending on the target contaminants. There is potential that these IX resins may be able to remove PFAS from groundwater, but investigation is needed to understand affinity/selectivity and removal capacity given the groundwater composition and the operating conditions. This report provides background on PFAS uses and chemistry, then provides a review of IX resin applications for PFAS, identifying knowledge gaps. Recommendations are provided regarding research needed to address knowledge gaps and acquire information needed to propose IX as a future PFAS remediation technology at the Hanford Site, as well as other U.S. Department of Energy sites. Generally, PFAS compounds are fluorinated substances that contain at least one fully fluorinated methyl or methylene carbon – with a few noted exceptions, any chemical with at least a perfluorinated methyl group (–CF3) or a perfluorinated methylene group (–CF2–) is a PFAS. These chemical compounds are characterized as non-biodegradable, non-reactive, non-photolytic, and hydrolysis resistant. This makes them highly recalcitrant within the environment, however polyfluoroalkyl materials are less recalcitrant as the carbon chains contain C–H bonds which are more easily broken than carbon – fluorine (C–F) bonds. The backbone carbon structures are commonly punctuated with a head group, the most well-known of them are perfluorooctanesulfonic acid and perfluorooctanoic acid, which possess a sulfonate and a carboxylate group, respectively. IX resins are marketed for the removal of PFAS from water systems and industrial water, however, the mechanism of removal is not as well understood as for anion or cation removal. A better understanding of the mechanism of removal would enable the development of IX resins that have improved specificity for PFAS removal. Four knowledge gaps were identified: 1) the effect of dissolved ions on the IX resin PFAS removal effectiveness, 2) the effect of additional primary contaminants of concern (PCOCs) or secondary contaminants of concern (SCOCs) on the effectiveness of PFAS via IX resin, 3) the mechanisms of PFAS removal from water, and 4) practical solutions to IX resin regeneration and waste disposal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LAPS Lidar Measurements at the ARM Alaska Northslope Site (Support to FIRE Project)

This report consists of data summaries of the results obtained during the May 1998 measurement period at Barrow Alaska. This report does not contain any data interpretation or analysis of the results which will follow this activity. This report is forwarded with a data set on magnetic media which contains the reduced data from the LAPS lidar in 15 minute intervals. The data was obtained during the period 15-30 May 1998. The measurement period overlapped with several aircraft flights conducted by NASA as part of the FIRE project. The report contains a summary list of the data obtained plus figures that have been prepared to help visualize the measurement periods. The order of the presentation is as follows: Section 1. A copy of the Statement of Work for the planned activity of the second measurement period at the ARM Northslope site is provided. Section 2. A list of the data collection periods shows the number of one minute data records stored during each hour of operation and the corresponding size (Mbytes) of the one hour data folders. The folder and file names are composed from the year, month, day, hour and minute. The date/time information is given in UTC for easier comparison with other data sets. Section 3. A set of 4 comparisons between the LAPS lidar results and the sondes released by the ARM scientists from a location nearby the lidar. The lidar results show the +/- 1 sigma statistical error on each of the independent 75 m altitude bins of the data. This set of 4 comparisons was used to set and validate the calibration value which was then used for the complete data set. Section 4. A set of false color figures with up to 10 hours of specific humidity measurements are shown in each graph. Two days of measurements are shown on each page. These plots are crude representations of the data and permit a survey which indicates when the clouds were very low or where interesting events may occur in the results. These plots are prepared using the real time sequence plot program which has no smoothing in either the altitude or time (except that you are allowed to pick the integration time and time step. All of these plots were prepared with 15 minute integration and 5 minute time step. Section 5. A set of time sequence data for all of the extended observation periods are shown with a smoothing algorithm from the Matlab plotting library. Most of these data are integrated for 5 minutes and stepped at I minute intervals but several plots are shown with both 15 minute integration and 5 minute steps. The upper level on these data was selected and converted to the white background where the error in the specific humidity reached 25%. Section 6. The set of one hour integrated plots shown with up to 4 hours per page are provided- from the real time analysis snapshot program. The only difference in these plots and the real time display is that the plots are stopped at an altitude where the error appears to be too large for the data to contain any meaningful information.

Philbrick, C. Russell↗

Measurement Report :Emission Factors of NH3 and NHx for Wildfires and Agricultural Fires in the United States

During the 2019 Fire Influence on Regional to Global Environments and Air Quality (FIREX-AQ) study, the NASA DC-8 carried out in situ chemical measurements in smoke plumes emitted from wildfires and agricultural fires in the contiguous United States. The DC-8 payload included a modified proton-transfer-reaction time-of-flight mass spectrometer (PTR-ToF-MS) for the fast measurement of gaseous ammonia (NH 3 ) and a high-resolution time-of-flight aerosol mass spectrometer (AMS) for the fast measurement of submicron particulate ammonium (NH 4 + ). We herein report data collected in smoke plumes emitted from 6 wildfires in the Western United States, 2 prescribed grassland fires in the Central United States, 1 prescribed forest fire in the Southern United States, and 66 small agricultural fires in the Southeastern United States. Smoke plumes contained double to triple digit ppb levels of NH 3 . In the wildfire plumes, a significant fraction of NH 3 had already been converted to NH 4 + at the time of sampling (≥2 h after emission). Substantial amounts of NH 4 + were also detected in freshly emitted smoke from corn and rice field fires. We herein present a comprehensive set of emission factors of NH 3 and NH x , with NH x = NH 3 + NH 4 + . Average NH 3 and NH x emission factors for wildfires in the Western United States were 1.86±0.75 g kg −1 and 2.47±0.80 g kg −1 of fuel burned, respectively. Average NH 3 and NH x emission factors for agricultural fires in the Southeastern United States were 0.89±0.58 and 1.74±0.92 g kg −1 , respectively. Our data show no clear inverse correlation between modified combustion efficiency (MCE) and NH 3 emissions. The observed NH 3 emissions were significantly higher than measured in previous laboratory experiments in the FIREX FireLab 2016 study.

Laura Tomsche↗

Criticality Control Overpack Fire Testing (Phase III)

This report will describe the one test conducted during phase III of the Pipe Overpack Container (POC) test campaign, present preliminary results from these tests, and discuss implications for the Criticality Control Overpack (CCO). The goal of this test was to see if aerosol surrogate material inside the Criticality Control Container (CCC) gets released when the drum lid of the CCO comes off during a thirty-minute long, fully-engulfing, fire test. As expected from POC tests conducted in Phase I and II of this test campaign, the CCO drum lid is ejected about one minute after the drum is exposed to fully-engulfing flames. The remaining pressure inside the drum is high enough to eject the top plywood dunnage a considerable distance from the drum. Subsequently, most of the bottom plywood dunnage supporting the CCC burns off during and after the fire. High pressure buildup inside the CCC and inside two primary containers holding the surrogate powder also results in damage to the filter media of the CCC and the filter-house, thread attachment of the primary canisters. No discernable release of surrogate powder material was detected from the two primary containers when pre- and post-test average mass were compared. However, when the average masses are corrected to account for possible uncertainties in mass measurements, error overlap does not preclude the possibility that some surrogate powder mass may have been lost from these primary canisters. Still, post-test conditions of the secondary canisters enclosing these two primary canisters suggest it is very unlikely this mass loss would have escaped into the CCC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Examination of entrainment, combustibility, and heat transfer due to cell venting inside simplified battery energy storage enclosures

Battery energy storage systems (ESS) assembled of modules containing lithium-ion batteries can pose fire and explosion hazards during thermal runaway because vented gases may accumulate, combust, or escape enclosures. Here, we propose a prototypical configuration composed of the main components of an ESS rack, where modules are represented as rectangles within an enclosure and vent gas is injected steadily through the top of a module. This idealized geometry allows for exploration of how rack-level characteristics can influence smaller single-cell or module-level scales. Through this geometry, we conduct numerical simulations to understand how variations in the vent velocity, temperature, and vertical location affect entrainment rates, fraction of uncombusted fuel, rich-gas coverage, and heat flux to other modules. At lower vent velocities and vertical positions, buoyancy drives enough entrainment and mixing to react with most of the vent gases on the converging plenum. As jet momentum increases and/or buoyancy decreases via higher vent position in the rack, vent gases can propagate into and burn in the divergence plenum. Heat flux to the impinged module scales strongly with vent momentum and temperature, while heat transfer to upper modules peaks when flames in the diverging plenum reach the surface and declines when combustion is suppressed.

Computational fluid dynamics↗

Using Ionic Liquid Additive to Enhance Lubricating Performance for Low-Viscosity Engine Oil

Energy efficient lubricants are essential for sustainable transportation, and the trend is to develop and implement lower viscosity lubricants with more effective additives. Ionic liquids (ILs) have been reported as candidate additives with superior friction and wear reducing capabilities. Unlike most literature relying on bench-scale testing of simple oil–IL blends, this study produced low-viscosity (SAE 0W-12) fully formulated engine oils using a phosphonium-organophosphate IL as an antiwear additive and evaluated them in both bench-scale tribological testing and full-scale fired engine dynamometer testing. The experimental formulation containing a combination of ZDDP and IL outperformed the formulations using either ZDDP or IL alone, as well as a commercial SAE 0W-20 engine oil in terms of mitigating boundary friction, wear, and contact fatigue-induced micropitting. Furthermore, racing engine dynamometer tests demonstrated 3–4 °C lower oil temperature, 4–5 ft-lbs higher horsepower output, and up to 9.9% better fuel economy for the IL-containing SAE 0W-12 experimental oil compared with selected commercial SAE 5W-30 and 0W-20 engine oils.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spin frustration and an exotic critical point in ferromagnets from nonuniform opposite g factors

Here, it is demonstrated that novel spin frustration can be induced in ferromagnets with nonuniform opposite Landé g-factors. The frustrated state is characterized by a mutual interplay of typical ferromagnetic (FM) and antiferromagnetic (AF) features, such as the zero-field susceptibility being FM-like at low temperatures but AF-like at high temperatures. It is also found to contain an exotic zero-temperature 'half fire, half ice' critical point at which the spins on one sublattice are fully disordered and on the other one are fully ordered. We suggest that such frustration may occur in a number of copper-iridium oxides such as Sr 3 CuIrO 6 . We also anticipate a realization of the frustration and 'partial fire, partial ice' states in certain antiferromagnets, lattice gas, and neuron systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of Irradiation on Thermal Properties of Polyurethane Foam

Polyurethane foam is used as a thermal insulator, fire protective material, and impact absorber in the 9977 shipping package. The 9977 shipping package is used to transport special nuclear materials (SNM), and store SNM in the K-area complex at the Savannah River Site. The primary fire-retardant mechanism in the foam is that it produces intumescent char when exposed to high temperatures. Intumescence occurs in the direction of heat application and can allow the foam to “repair” cracks in the event of a mechanical impact, in addition to serving as a secondary thermal barrier with decreased heat conductivity. Because the foam is being used for long-term storage applications, it is vital that it retain its physical, thermal, and mechanical properties over the course of time and with the events of exposure of heat and irradiation. The goal of this project was to determine the effects of gamma irradiation on the thermal properties of polyurethane foam, both in terms of cumulative irradiation and rate of irradiation. At the dose rates and cumulative doses of irradiation measured, there was no correlation between higher cumulative irradiation and thermal stability, specific heat capacity, or chemical structure. Based on the results of the experiments, the fire protective properties in the 9977 shipping containers should be retained with the expected amount of radiation exposure.

36 MATERIALS SCIENCE↗

Lightweight, Fire-Resistant Graphite Composites

Aircraft safety improved with interior paneling made of new laminate with good thermophysical properties. Featuring lightweight graphite composite, laminate more heat-and flame-resistant and produces much less smoke in fire than commonly used epoxy-resin-containing laminates. New laminate prepared without epoxy resin. Graphite unidirectional cloth preimpregnated with blend of vinyl polystyrylpyridine and bismaleimide (VPSP-BMI). Either of two types of VPSP-BMI blend used, depending on method of preparation of chemicals and technique used to fabricate panel.

Kourtides, D. A.↗

CID overview

On December 1, 1984, NASA and the Federal Aviation Administration (FAA) conducted the first remotely piloted air-to-ground crash test of a transport category aircraft. The Full-Scale Transport Controlled Impact Demonstration (CID) was the culmination of 4 years of effort by the two agencies. NASA and the FAA had many objectives during the joint planning and execution of the Controlled Impact Demonstration. The structural loads experiment was very successful. Ninety-seven percent of the channels were active at impact. The data is still being assessed. Only a portion of the data is presented here; approximately 80 channels of data are available. Analysis of the remaining data is in progress. Interior photography was also very successful. One hundred percent of the cameras functioned. The film contains unique information on the development of fire and smoke in the interior of the aircraft. From a human tolerance point of view, the CID was simulation of a survivable crash.

Hayduk, R. J.↗

Multiple-Nozzle Spray Head Applies Foam Insulation

Spray head equipped with four-nozzle turret mixes two reactive components of polyurethane and polyisocyanurate foam insulating material and sprays reacting mixture onto surface to be insulated. If nozzle in use becomes clogged, fresh one automatically rotated into position, with minimal interruption of spraying process. Incorporates features recirculating and controlling pressures of reactive components to maintain quality of foam by ensuring proper blend at outset. Also used to spray protective coats on or in ships, aircraft, and pipelines. Sprays such reactive adhesives as epoxy/polyurethane mixtures. Components of spray contain solid-particle fillers for strength, fire retardance, toughness, resistance to abrasion, or radar absorption.

Walls, Joe T.↗

Vanguard Satellite Separation Mechanisms

Early in the Vanguard program it became apparent that a thoroughly reliable means of separating the satellite packages from the third-stage rocket would be required. A completely self -contained standard mechanism was developed with redundant firing circuits for use on both test vehicles and satellite-launching vehicles. A change in the experimental objectives of the test-vehicle payload units necessitated modification of some of the standard separation mechanisms. A strap, pull-pin, girth-ring separation device was developed which employed the basic actuation of the standard mechanisms. Evidence of residual burning of the third stage made it necessary to delay separation longer than the time designed into the long-delay separation device. The standard separation mechanism was modified and integrated with the satellite command receiver system so that a ground command after third-stage burnout would cause separation. Flight performance of the various separation mechanisms proved their reliability; they performed without failure in all Vanguard launchings.

Baumann, Robert C.↗

Real-Time Object Recognition in Color Imagery

Military test ranges containing unexploded ordnance due to live-fire testing and training exercises are a significant safety problem in many locations.

object recognition color imagery unexploded ordnan↗

Bayesian Assessment of Chlorofluorocarbon (CFC), Hydrochlorofluorocarbon (HCFC) and Halon Banks Suggest Large Reservoirs Still Present in Old Equipment

Halocarbons contained in equipment such as air conditioners, fire extinguishers, and foams continue to be emitted after production has ceased. These ‘banks’ within equipment and applications are thus potential sources of future emissions, and must be carefully accounted for in order to evaluate nascent production versus banked emissions. Here, we build on a probabilistic Bayesian model, previously developed to quantify CFC-11, 12 and 113 banks and their emissions. We extend this model to a suite of the major banked chemicals regulated under the Montreal Protocol (HCFC-22, HCFC-141b, and HCFC-142b, halon-1211, and halon-1301, and CFC-114 and CFC-115) along with CFC-11, 12 and 113 in order to quantify a fuller range of ozone-depleting substance banks by chemical and equipment type. We show that if atmospheric lifetime and prior assumptions are accurate, banks are very likely larger than previous international assessments suggest, and that total production has been very likely higher than reported. We identify that banks of greatest climate-relevance, as determined by global warming potential weighting, are largely concentrated in CFC-11 foams and CFC-12 and HCFC-22 non-hermetic refrigeration. Halons, CFC-11, and 12 banks dominate the banks weighted by ozone depletion potential. Thus, we identify and quantify the uncertainties in substantial banks whose future emissions will contribute to future global warming and delay ozone hole recovery if left unrecovered.

Halocarbons↗

A Mobile Robot for Remote Response to Incidents Involving Hazardous Materials

This paper will describe a teleoperated mobile robot system being developed at JPL for use by the JPL Fire Department/HAZMAT Team. The project, which began in October 1990, is focused on prototyping a robotic vehicle which can be quickly deployed and easily operated by HAZMAT Team personnel allowing remote entry and exploration of a hazardous material incident site. The close involvement of JPL Fire Department personnel has been critical in establishing system requirements as well as evaluating the system. The current robot, called HAZBOT III, has been especially designed for operation in environments that may contain combustible gases. Testing of the system with the Fire Department has shown that teleoperated robots can successfully gain access to incident sites allowing hazardous material spills to be remotely located and identified. Work is continuing to enable more complex missions through enhancement of the operator interface and by allowing tetherless operation.

robots teleoperator hazardous materials HAZMAT HAZ↗