Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Filtration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Analysis of strategies to meet ASHRAE S241 infectious aerosol control targets by space type and region using EnergyPlus™ simulations

Professional organizations, such as ASHRAE, have recently proposed new voluntary standards for controlling infectious aerosols. Specifically, ASHRAE Standard 241 (S241) defines equivalent clean air targets for a range of space types that can be met through combinations of mitigation measures. This paper seeks to inform the selection of measures by space type and climate zone through building simulations that quantify the impacts of increased outdoor air ventilation; increasing filtration and/or adding germicidal ultraviolet (GUV) in the central heating, ventilation, and air-conditioning (HVAC) systems; or using portable air cleaners (PACs), upper room GUV, or whole room GUV approaches to increase equivalent clean air delivery. The measures are assessed individually and in practical combinations for their ability to meet S241 in four space types (offices, classrooms, dining areas, and healthcare waiting rooms) using prototype buildings modeled using EnergyPlus. The mitigation measures are compared holistically against baseline building operations using metrics for equivalent clean air, energy, and comfort. The results in this study show that single measures can meet S241 for offices with minimal impacts on energy and comfort, while either upper room GUV systems or combinations of measures such as MERV 13 HVAC filtration with PACs are needed to meet S241 for classrooms. The dining area and healthcare waiting room targets cannot be met in this study when assuming design occupancy and MS2 as the challenge agent, even when combining multiple measures together. This paper provides valuable considerations when designing measures to meet S241 for a range of spaces and scenarios.

GUV

Seeding Advanced Treated Wastewater for Purposes of Direct Potable Reuse

Direct potable reuse (DPR) is a promising solution to address water scarcity. However, a better understanding of how introducing advanced treated water (ATW) affects microbial communities present in distribution systems is needed. Here, in this study, we measured changes to the microbial water quality in simulated distribution systems that were conditioned using treated, unimpaired surface water (SW) and then transitioned to ATW. In addition, we investigated whether adding a biological filtration step would seed the microbial community of the ATW and whether the influence would persist in the simulated distribution systems. We found that the bulk water in the ATW-fed distribution systems had lower cell counts and ATP concentrations and a distinct microbial community (based on 16S amplicon sequencing) compared to the SW-fed or the seeded ATW-fed systems. However, biofilm community composition and biomass remained consistent regardless of the feedwater. Increased microbial biomass and diversity were present in the seeded ATW, with several amplicon sequence variants identified as being introduced by the biological filter. Our results suggest that directly introducing ATW to distribution systems could disturb the existing microbial community. Preparing ATW for distribution via biological filtration may deliver more predictable and stable microbial water quality than introducing unseeded ATW.

16S

Development of a pilot system for converting sweet potato starch into glucose syrup

Sweet potato has been chosen as one of NASA's crops to support human beings in future space missions. One of the possible uses is to make syrup that can be used as a general sweetener. In this work a simple engineering system for converting sweet potato starch into glucose syrup was studied on a laboratory scale. The system comprises the following main units: a blender, continuous stirred tank reactor (CSTR), centrifugal and vacuum filters, deionization column and vacuum evaporator. The system was tested by carrying out conversion processes from fresh sweet potato roots. The roots were pealed, sliced, homogenized, heated and hydrolyzed by diastase of malt and Dextrozyme C (Novo Nordisk BioChem, North America, Inc.) enzymes in the CSTR. After hydrolysis the slurry was filtered, de-ionized and concentrated to get glucose syrup. The performance of the system was evaluated based on the quality of the conversion. The main factor was the level of reducing sugars except for the deionization where ash content and color were the main factors. Through careful control of the system units, good heating performance in the CSTR was obtained and the hydrolysis process attained sufficient conversion. The filtration process that incorporated the centrifuge was faster than when it was by-passed to the vacuum filter but losses in sugars were higher. Deionization removed more than 90% of the ash and reduced pigmentation, with probable insignificant losses in sugars during the deionization process. Recovery levels when the centrifuge was used and when it was by-passed could reach about 65% and 78%, respectively. These correspond to reducing sugar concentration of 259 and 310 mg/ml in 150-ml syrups from 300 g of sweet potatoes in each process. However, from concentration trials, syrups with volumes of 100 and 70 ml with the respective dextrose equivalence of 281 and 213 mg/ml were obtained. The syrups obtained were brownish in color and the process that employed centrifugal filtration gave a product with color that resembled the original color of the sweet potatoes. Further work is required to improve the overall system performance.

Non-NASA Center

Filter Media Tests Under Simulated Martian Atmospheric Conditions

Human exploration of Mars will require the optimal utilization of planetary resources. One of its abundant resources is the Martian atmosphere that can be harvested through filtration and chemical processes that purify and separate it into its gaseous and elemental constituents. Effective filtration needs to be part of the suite of resource utilization technologies. A unique testing platform is being used which provides the relevant operational and instrumental capabilities to test articles under the proper simulated Martian conditions. A series of tests were conducted to assess the performance of filter media. Light sheet imaging of the particle flow provided a means of detecting and quantifying particle concentrations to determine capturing efficiencies. The media's efficiency was also evaluated by gravimetric means through a by-layer filter media configuration. These tests will help to establish techniques and methods for measuring capturing efficiency and arrestance of conventional fibrous filter media. This paper will describe initial test results on different filter media.

Martian Atmosphere

Filter Efficiency and Leak Testing of Returned ISS Bacterial Filter Elements After 2.5 Years of Continuous Operation

The atmosphere revitalization equipment aboard the International Space Station (ISS) and future deep space exploration vehicles provides the vital functions of maintaining a habitable environment for the crew as well as protecting the hardware from fouling by suspended particulate matter. Providing these functions are challenging in pressurized spacecraft cabins because no outside air ventilation is possible and a larger particulate load is imposed on the filtration system due to lack of sedimentation in reduced gravity conditions. The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Adsorption (HEPA) filters deployed at multiple locations in each module. These filters are referred to as Bacteria Filter Elements (BFEs). As more experience has been gained with ISS operations, the BFE service life, which was initially one year, has been extended to two to five years, dependent on the location in the U.S. Segment. In previous work we developed a test facility and test protocol for leak testing the ISS BFEs. For this work, we present results of leak testing a sample set of returned BFEs with a service life of 2.5 years, along with particulate removal efficiency and pressure drop measurements. The results can potentially be utilized by the ISS Program to ascertain whether the present replacement interval can be maintained or extended to balance the on-ground filter inventory with extension of the lifetime of ISS to 2024. These results can also provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

ISS Air Quality

International Space Station (ISS) Bacterial Filter Elements (BFEs): Filter Efficiency and Pressure Testing of Returned Units

The air revitalization system aboard the International Space Station (ISS) provides the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation due to the microgravity environment in Low Earth Orbit (LEO). The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Adsorption (HEPA) media filters deployed at multiple locations in each U.S. Segment module; these filters are referred to as Bacterial Filter Elements, or BFEs. These filters see a replacement interval, as part of maintenance, of 2-5 years dependent on location in the ISS. In this work, we present particulate removal efficiency, pressure drop, and leak test results for a sample set of 8 BFEs returned from the ISS after filter replacement. The results can potentially be utilized by the ISS Program to ascertain whether the present replacement interval can be maintained or extended to balance the on-ground filter inventory with extension of the lifetime of ISS beyond 2024. These results can also provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

Filtration

Filter Efficiency and Pressure Testing of Returned ISS Bacterial Filter Elements (BFEs)

The air quality control equipment aboard the International Space Station (ISS) and future deep space exploration vehicles provide the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation. The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Air (HEPA) filters deployed at multiple locations in each U.S. Seg-ment module; these filters are referred to as Bacterial Filter Elements, or BFEs. In our previous work, we presented results of efficiency and pressure drop measurements for a sample set of two returned BFEs with a service life of 2.5 years. In this follow-on work, we present similar efficiency, pressure drop, and leak tests results for a larger sample set of six returned BFEs. The results of this work can aid the ISS Program in managing BFE logistics inventory through the stations planned lifetime as well as provide insight for managing filter element logistics for future exploration missions. These results also can provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

ISS Air Quality

International Space Station (ISS) Bacterial Filter Elements (BFEs): Filter Efficiency and Pressure Drop Testing of Returned Units

The air quality control equipment aboard the International Space Station (ISS) and future deep space exploration vehicles provide the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation. The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Air (HEPA) filters deployed at multiple locations in each U.S. Seg-ment module; these filters are referred to as Bacterial Filter Elements, or BFEs. In our previous work, we presented results of efficiency and pressure drop measurements for a sample set of two returned BFEs with a service life of 2.5 years. In this follow-on work, we present similar efficiency, pressure drop, and leak tests results for a larger sample set of six returned BFEs. The results of this work can aid the ISS Program in managing BFE logistics inventory through the stations planned lifetime as well as provide insight for managing filter element logistics for future exploration missions. These results also can provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

ISS Air Quality

Influence of overhead HVAC and aerosol control strategies on coarse mode particle dispersion and exposure in a full-scale room experiment

Coarse mode respiratory aerosols can carry viral loads over long distances and have very different dynamics than submicron particles, but experimental studies under realistic conditions remain limited. Here, to study the differential impacts on exposure under different mixing conditions, we co-released 7–10 µm particles and carbon dioxide (CO 2 )—which served as an indicator of gas and submicron particle dynamics—in a 158 m 3 room at LBNL's FLEXLAB facility with an overhead heating, ventilation, and air conditioning (HVAC) system. The room was arranged as a distanced meeting then a classroom with eight heated manikins and a researcher. Spatial variability was measured using 16 particle counters and 22–26 CO 2 sensors throughout the space. Conditions included: HVAC off or supply air at 1000-1060 m 3 h -1 at neutral, cooling, or heating temperatures; with and without 20% outdoor air; and added HVAC filtration, portable air cleaners (PACs), or a physical barrier between the speaker and occupants. We found that good mixing via neutral or cooling supply air or use of PACs under heating lowered coarse particle exposure at some locations, but increased exposure for one-quarter to two-thirds of manikins compared to poor mixing under heating. A physical barrier reduced direct transfer of coarse particles during heating, but less during cooling. High spatial variability shows that a single measurement cannot represent occupant exposure. Instantaneous air mixing assumptions overstate the effectiveness of ventilation, HVAC filtration, and upper-room germicidal ultraviolet disinfection for coarse particles, as relatively few particles reach the return grille or upper room under most conditions.

Air mixing

Calcium-organic matter fouling in nanofiltration: Synchrotron-based X-ray fluorescence and absorption near-edge structure spectroscopy for speciation

Calcium (Ca)-enhanced organic matter (OM) fouling of nanofiltration (NF) membranes leads to reduced flux during desalination and requires frequent cleaning. Fouling mechanisms are not fully understood, which limits the development of targeted fouling control methods. This study employed synchrotron-based X-ray fluorescence (XRF) and X-ray absorption near-edge structure (XANES) spectroscopy to quantify the spatial distribution and mass of Ca deposition as well as changes in the Ca coordination environment characteristic of specific fouling mechanisms, respectively. Bench-scale filtration experiments were performed using feed solutions containing Ca and ten different types of organic matter (OM), as well as the common scalants, calcium carbonate (CaCO 3 ) and calcium sulfate (CaSO 4 ). Osmotic backwash (OB) was performed at regular intervals for fouling control. Ca-OM aggregation resulted in greater flux decline and lower flux recovery during OB than Ca conditioning of membranes followed by filtration of feed solution with OM. Linear combination fitting (LCF) of XANES absorption spectra from fouled membranes indicated that Ca-OM aggregation preferentially occurred for OM types that exhibited both high carboxylic group and negative charge density. Consequently, these OM types exhibited greater deposition of Ca and TOC on the membrane surface when compared to other OM types. For the coexistence of scalants and OM, Ca speciation within the fouling layer was characteristic of both Ca bound to the membrane (i.e. potential bridging, charge screening) as well as Ca-OM aggregation and deposition mechanisms, while a range of crystal polymorphs were observed to occur simultaneously. XRF and XANES represent powerful tools for the elucidation of NF fouling mechanisms by quantification of Ca deposition as well as Ca speciation. Fouling control methods should target OM types with high carboxyl group density and negative charge to neutralize or eliminate interactions with Ca.

42 ENGINEERING

DeSelenator: A Se-Removal Process for Environmental Decontamination of Wastewaters from Coal-Burning Power Plants

Selenium may become a toxic contaminant of freshwater systems when released into the environment through industrial wastewaters from mining, coal-burning power plants, or oil refining. Efficient and cost-effective Se-removal technologies are therefore necessary to reduce Se concentrations in these wastewaters to below the regulatory discharge limits. In this study, we have demonstrated an effective process that removes Se, mostly as selenate anions, from wastewaters generated by coal-burning power plants. This process, dubbed DeSelenator, leverages the high concentration of sulfate relative to selenate in the wastewater and the propensity of these oxyanions to cocrystallize with benzene-bis-iminoguanidinium (BBIG) cations into extremely insoluble salts (on par with BaSO 4 ). The SO 4 2− /SeO 4 2− cocrystallization with BBIG removes over 90% of S and Se from the wastewater. Following removal of the precipitate by filtration, the filtrate is passed over an anion-exchange resin that further reduces selenium concentration to 5 ppb, the EPA’s regulatory limit for freshwater systems. Finally, the effluent is passed over an activated carbon column, which removes 99.8% of the residual BBIG ligand remaining after crystallization, allowing for the safe discharge of the treated water into the environment. The Se-removal process was first optimized in the lab at the bench scale and then tested in the field at the Tennessee Valley Authority’s Bull Run coal-burning power plant. A technoeconomic assessment found the cost of water treatment with DeSelenator is on par with that of the active biological method, which is currently considered a state-of-the-art Se-removal technology.

anions

Recovery of Oxpure 612C-50 Coconut Carbon Particles Using Bump Arrays

Cyanide is used to leach gold from crushed ore (solid matrix) into a gold cyanide solution. The gold is extracted from the cyanide solution by adsorption onto activated carbon. The gold extraction process occurs when the activated coconut carbon is placed into tanks that contain the gold cyanide solution either in a batch process or into a continuous flow circuit. The coconut carbon is then removed from the solution for gold recovery. The use of the mesofluidic separation system (a deterministic lateral displacement system) can significantly reduce costs and waste generated from the process of removing the coconut carbon from the solution. In the coconut carbon recovery process used at many gold mines in Nevada, the gold is attached to carbon particles that are still in the cyanide liquor. The mesofluidic system can rapidly remove the gold bearing carbon particles from the cyanide liquor quickly and with no operating costs. The benefits include: • Reduce operational costs related to filtration and hydro-cyclones • Reduced acid usage for the elution gold stripping phase as only 25% of the fluids will follow the carbon particles to the final express lane when two mesofluidic systems are used in series This alternative particle removal techniques would be advantageous. A promising technique for removing larger particles from slurries is mesofluidic separation, similar to deterministic lateral displacement arrays or “bump” arrays [1] but operates at much larger flow rates. As described by Pease, et al. [2], “Bump arrays in deterministic lateral displacement devices separate large particles from small particles using arrays of staggered posts. Large particles, defined as those with radii larger than the distance between the edge of a post and the stagnation streamline from the next downstream post, must bump toward one side of the device, whereas particles smaller than this distance slalom from entrance to exit without net lateral displacement.” Unlike filters or sieves, the posts in the arrays that cause separation do not block or occlude particle flow but work because particles go around the posts. Unlike hydrocyclones separation, separation is not driven by particle density, because gravitational forces are unimportant to mesofluidic separation. Burns, et al., and Pease, et al., have shown that particles may be separated from complex suspensions, under turbulent flow conditions, and at industrially important flow rates [3-5]. They have also recently shown that mesofluidic devices may be arranged in series to increase separation performance [6]. In this paper, we evaluate the mesofluidic system for the separation of commercial OxPure GR 612 Charred Coconut shell particles as a proof of principle test for the rapid separation using the 1500 micron cut mesofluidic separator. We first describe the experimental system and conditions. We then present the experimental results. [1] Huang, L.R., E.C. Cox, R.H. Austin, J.C. Sturm. 2004. Continuous particle separation through deterministic lateral displacement. Science, 304, 987–990. https://doi.org/10.1126/science.1094567. [2] Pease L.F., J.A. Bamberger, C.A. Burns, and M.J. Minette. 2021. Large Particle Separation from Non-Newtonian Slurries using Bump Arrays. In Proceedings of the ASME 2021 Fluids Engineering Division Summer Meeting FEDSM2021-65904, V003T08A023. New York, New York: ASME. doi:10.1115/FEDSM2021-65904 [3] Burns C.A., T.G. Veldman, J. Serkowski, R.C. Daniel, X.-Y. Yu, M.J. Minette, L.F. Pease. 2021. Mesofluidic separation versus dead-end filtration. Separation and Purification Technology, 254, 117256. https://doi.org/10.1016/j.seppur.2020.117256. [4] Pease L.F., J.E. Serkowski, T.G. Veldman, J. Williams, X.-Y. Yu, M.J. Minette, J.A. Bamberger, C.A. Burns. 2021. Can Bump Arrays Separate Particles from Turbulent Flows?. In Proceedings of the ASME 2021 Fluids Engineering Division Summer Meeting FEDSM2021-67696, V003T08A024. New York, New York: ASME. doi:10.11

mesofluidic separation, slurry, bump array

Pigment removal from reverse-printed laminated flexible films by solvent-targeted recovery and precipitation

The solvent-targeted recovery and precipitation (STRAP) process separates and recovers the constituent resins in multilayer plastic packaging films by selective polymer dissolution. In this work, the cause of coloring in the STRAP-recycled polyethylene (PE) resins from postindustrial printed films was identified as decomposed diarylide pigments. Two different approaches are needed to completely remove the dissolved colorants during the STRAP process including (i) adding an activated carbon (AC) adsorbent to the solvent after polymer dissolution and (ii) proper mechanical filtration of the polymer-solvent cake to remove as much solvent from the cake as possible. Colorless recycled PE can be produced by a combination of the proposed approaches (choosing the proper solvent, adding an AC adsorbent, and doing proper mechanical filtration) with minimal accumulation of colorants in the recycled STRAP solvents. This study demonstrated that high-quality STRAP low-density PE can be obtained from printed plastic films, enhancing the potential circularity of these packaging materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Closing the loop: model-predictive control for a closed-circuit reverse osmosis system

This article presents a model-predictive controller (MPC) for the maximization of the energy efficiency of a closed-circuit desalination reverse osmosis (CCRO) system. CCRO is a process for producing drinking water that is based on a cyclic operation with the following two phases: (a) filtration and (b) drain. In this article, we test model predictive control for optimal control of this process. The most important features of our approach are as follows: (a) the selection of a model structure that enables reliable forecasts of the filtration phase (up to 3 h), (b) an on-line model calibration strategy that ensures model forecast reliability, and (c) the satisfaction of equipment safety and operational constraints on the selected setpoints. We challenge this through deliberate introduction of changes in the unmeasured feed concentration and the applied constraints. Our results indicate that frequent model parameter updates are critical to maintain model reliability for MPC purposes. In addition, we illustrate that parameter identifiability is not guaranteed and that deliberate variation in flow rates is necessary even though the process never operates in steady state. Finally, MPC can compute flow rate setpoints that maximize the energy efficiency of the CCRO process while satisfying the applicable equipment and safety constraints.

closed-circuit reverse osmosis

Mark-18A Cold Runs

The Savannah River National Laboratory (SRNL) is tasked by the National Nuclear Security Administration (NNSA) to recover highly valued isotopes from irradiated Mark-18A (Mk-18A) targets. The Savannah River Site (SRS) has sixty-five Mk-18A targets available for the recovery of the high valued materials. The sixty-five Mk-18A targets are currently stored in the L-Area Basin and will be removed one at a time and individually transported to SRNL. Upon receipt at SRNL, the Mk-18A target material will be removed from the confinement, dissolved, chemically separated, and calcined to a stable oxide. The flowsheet is designed to recover the plutonium as well as the trivalent actinides. The remaining unrecovered material will be discarded to the high activity drain (HAD) system in SRNL. A specially designed cask was procured for transport of the targets from L-Area to SRNL. Once received at SRNL, the targets will be loaded into the back of Cell 7 and resized as they enter the cell. The resized targets (1/4 lengths) will then be processed one at a time through the following processes: caustic dissolution and filtration; acidic dissolution and filtration, Reillex anion exchange, diglycolamide (DGA) cation exchange; and DGA calcination. This processing will result in two product streams. The first is an aqueous plutonium solution which will be removed from the shielded cells and taken to a glovebox for further purification and conversion to an oxide. The second is a calcined oxide containing the Am and Cm as well as other lanthanide fission products which will be removed from the shielded cells using a bagless transfer system. Both materials will be packaged for shipment to Oak Ridge National Laboratory (ORNL). All equipment to carry out this process was designed, procured or fabricated, and installed in a mock-up facility (716-4A) at SRS to allow for simulation testing in a non-radioactive area. This equipment was then dismantled and transferred from 716-4A to 773-A and installed in the SRNL Shielded Cells. After installation in the shielded cells facility testing was performed using water followed by surrogates and cold chemicals. Issues were identified during these evaluations, including equipment issues as well as technical challenges. Many of the issues were rectified during performance of the cold runs, and the remaining have a resolution identified. Table ES-1 provides a summary of all issues identified during the cold run operations, as well as the status and identified resolutions to outstanding issues.

07 ISOTOPE AND RADIATION SOURCES

Characterization of Tank 9H Annulus Sample in Support of Residual Material Inventory Determinations

The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC) to provide sample preparation and characterization of the Tank 9H annulus sample in support of Residual Material Inventory Determinations. One Tank 9H sample in three vials [HTF-9-25-13, HTF-9-25-14 and HTF-9-25-15], with each vial containing approximately 200 mL of the Tank 9H annulus salt solution, were delivered to the SRNL Shielded Cells for sample preparation and characterizations in February 2025. The density of the “as-received” solution contained in each of the three Tank 9H annulus sample vials were determined followed by a solid-liquid separation on each one using 0.45-micron Nalgene® nylon filter membranes. The resulting filtrates were combined to form the Tank 9H annulus sample with a total volume of about 600 mL. The combined wet solid fractions, about a total of 4.8 grams of salt material, remaining on the filter membranes were air-dried in the Shielded Cells for 72 hours. The total weight of the air-dried solids was 2.1 grams. These air-dried solids were washed with deionized water (DI water) at a phase ratio of 60 mL DI water/gram of solids to recover insoluble solids, if any. No visible or measurable quantity of insoluble solids were recovered after DI water washing of the air-dried solids because the air-dried solids completely dissolved in the DI water. The solid fraction-wash water was not combined with the 600 mL of the filtrate solution, and the resulting solution was not screened or analyzed for radionuclides. Aliquot sample volumes of the undiluted Tank 9H annulus sample were sent to the SRNL analytical services groups for radionuclides, elementals, anions and total mercury analysis by various methods including radiochemical separations/counting methods, inductively coupled plasma-atomic emission spectroscopy (ICP-AES), and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) and special preparations. All sample analyses were performed in triplicate. This report presents the analytical characterization results for the Tank 9H annulus sample. The results are also reported where analytical methods yielded additional analytes, other than those requested by SRMC. In the characterization of the Tank 9H annulus sample, the detection limits for all the analytes, as specified in the Technical Task Request (TTR) and Task Technical and Quality Assurance Plan (TTQAP), were met.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Mesofluidic Inline Separation for Produced Water Treatment

Mesofluidic inline separation developed by PNNL represents an opportunity to remove a key barrier in the treatment of produced water, namely suspended solids that clog downstream operations. The US alone produces over 800 billion gallons of produced water each year, most of which is reinjected underground (but not into the aquifers) as waste. The impact from treating and reusing even a fraction of this wastewater is immense as aquifers in the Midwest and elsewhere dry. The work described herein is essential to leveraging the opportunity to improve produced water quality (to allow for beneficial use) by combining mesofluidic inline separators with reverse osmosis systems. Providing water for agricultural and industrial uses in the American Southwest and Midwest by allowing the reuse of petroleum produced water may be critical to the long-term economics of the region. This is especially true as drought conditions are rapidly lowering aquifer levels in these regions. The incumbent technology for desalination is reverse osmosis (RO) due to its ability to treat a wide range of feedwaters and technological maturity. However, suspended solids cause RO (and other dissolved solids removal technologies) to become clogged and loose performance. A common strategy is to use prefilters upstream of RO systems, but these membrane-based filters easily clog and require regular maintenance. Unlike membrane filters, mesofluidic inline separators provide removal of suspended solids with much lower pressure drops than conventional systems filtration systems, permitting substantially higher flowrates. Although the amount of produced water from petroleum operations is vast, only a small fraction of it is reused or turned into potable water, for example, because of the lack of technologies to remove both dissolved and suspended solids at a significant throughput. This project shows that mesofluidic inline separators coupled with a commercial dissolved solids removal technology (RO) are positioned to do exactly that. Mesofluidic inline separators fit within commercial piping and are tunable for particle sizes of interest as described below. Indeed, mesofluidic inline separators have remarkably smaller footprints than competing filtration technologies and are easily transportable from jobsite to jobsite. This technology has no moving parts so that solids removal can be accomplished at much lower operating cost.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Elimination of gases and contamination from water

Filtration system with membrane type hydrophilic and hydrophobic filters gives absolute filtration with automatic venting of freed gases, and prevents backward transmission of contamination with no bacterial growth through the filters. Filter aids in degassing industrial solutions and in removing oxygen from sea water.

Buck, A. P.