Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fabry-Perot interferometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Polar cap diurnal temperature variations - Observations and modeling

High-spectral-resolution measurements of the O(1D) emission line, performed with the Fabry-Perot interferometer (Thule, Greenland), were used to observe the diurnal variation of the thermospheric temperature in the geomagnetic polarcap at solar minimum (January 1987). By tracing the trajectory of a parcel backward in time and space from the Thule location, it is shown that the observed diurnal temperature variation is due to the degree of solar heat input that a parcel experiences en route to the polar cap, and the route a parcel takes through the polar cusp. It is also shown that the hydrodynamic variations in the winter high-latitude regions from solar maximum to solar minimum are insufficient to mask the thermodynamical effects associated with the offset of the geographic and geomagnetic poles.

Mccormac, F. G.↗

Three component laser anemometer measurements in an annular cascade of core turbine vanes with contoured end wall

The three mean velocity components were measured in a full-scale annular turbine stator cascade with contoured hub end wall using a newly developed laser anemometer system. The anemometer consists of a standard fringe configuration using fluorescent seed particles to measure the axial and tangential components. The radial component is measured with a scanning confocal Fabry-Perot interferometer. These two configurations are combined in a single optical system that can operate simultaneously in a backscatter mode through a single optical access port. Experimental measurements were obtained both within and downstream of the stator vane row and compared with calculations from a three-dimensional inviscid computer program. In addition, detailed calibration procedures are described that were used, prior to the experiment, to accurately determine the laser beam probe volume location relative to the cascade hardware.

Goldman, Louis J.↗

Balloon-based interferometric techniques

A balloon-borne triple-etalon Fabry-Perot Interferometer, observing the Doppler shifts of absorption lines caused by molecular oxygen and water vapor in the far red/near infrared spectrum of backscattered sunlight, has been used to evaluate a passive spaceborne remote sensing technique for measuring winds in the troposphere and stratosphere. There have been two successful high altitude balloon flights of the prototype UCL instrument from the National Scientific Balloon Facility at Palestine, TE (May 80, Oct. 83). The results from these flights have demonstrated that an interferometer with adequate resolution, stability and sensitivity can be built. The wind data are of comparable quality to those obtained from operational techniques (balloon and rocket sonde, cloud-top drift analysis, and from the gradient wind analysis of satellite radiance measurements). However, the interferometric data can provide a regular global grid, over a height range from 5 to 50 km in regions of clear air. Between the middle troposphere (5 km) and the upper stratosphere (40 to 50 km), an optimized instrument can make wind measurements over the daylit hemisphere with an accuracy of about 3 to 5 m/sec (2 sigma). It is possible to obtain full height profiles between altitudes of 5 and 50 km, with 4 km height resolution, and a spatial resolution of about 200 km, along the orbit track. Below an altitude of about 10 km, Fraunhofer lines of solar origin are possible targets of the Doppler wind analysis. Above an altitude of 50 km, the weakness of the backscattered solar spectrum (decreasing air density) is coupled with the low absorption crosssection of all atmospheric species in the spectral region up to 800 nm (where imaging photon detectors can be used), causing the along-the-track resolution (or error) to increase beyond values useful for operational purposes. Within the region of optimum performance (5 to 50 km), however, the technique is a valuable potential complement to existing wind measuring systems and can provide a low cost addition to powerful active (LIDAR) wind measuring systems now under development.

Rees, David↗

The radial velocity search for extrasolar planets

Stars are observed with a ground-based instrument designed to measure small changes in the line-of-sight velocities. The purpose of the observations is to detect large planets by the oscillatory reflex motion they induce on the stars they are orbiting. The instrument is an optical spectrometer for which wavelengths are first calibrated by transmission through a tunable Fabry-Perot etalon interferometer. Changes in the line-of-sight velocities are revealed by changes in the Doppler shift of the absorption-line spectra of stars. The scrambling of incident light by an optical fiber and the stability of wavelength calibration by a tilt-tunable Fabry-Perot etalon provide immunity to systematic errors that historically have effected more conventional radial velocity spectrographs. A cross-dispersed echelle spectrograph spatially separates the orders of constructive interference transmitted through the etalon. Selecting several echelle diffraction orders in the vicinity of 4250 to 4750 A, which are imaged on a CCD, about 350 points on the profile of the stellar spectrum are sampled by successive orders of interferometric transmission through the etalon.

Mcmillen, R. S.↗

The High Spectral Resolution Lidar

The High Spectral Resolution Lidar (HSRL) system was developed for the remote measurement of atmospheric optical properties. Measurements are obtained by the separation of the backscattered signal into aerosol and molecular channels using a high spectral resolution Fabry-Perot optical interferometer to separate the aerosol contributions to backscatter near the laser wavelength from the Doppler-shifted molecular component of the backscatter. The transmitter consists of an optically pumped pulsed dye laser of the oscillator-amplifier design which emits at 467.88 nm, with a bandwidth of less than 0.3 pm. The transmitter and receiver share a common Schmidt-Cassegrain telescope, although they do not share the same field stop, but rather two conjugate stops. The HSRL system uses a computer-controlled dual-channel photon-counting data acquisition system providing for stable measurements at very low power levels and an excellent dynamic range. The system has been used to obtain airborne measurements of height profiles of aerosol and molecular backscatter cross sections.

Eloranta, E. W.↗

High spectral resolution lidar to measure optical scattering properties of atmospheric aerosols. I - Theory and instrumentation

A high spectral resolution lidar technique to measure optical scattering properties of atmospheric aerosols is described. Light backscattered by the atmosphere from a narrowband optically pumped oscillator-amplifier dye laser is separated into its Doppler broadened molecular and elastically scattered aerosol components by a two-channel Fabry-Perot polyetalon interferometer. Aerosol optical properties, such as the backscatter ratio, optical depth, extinction cross section, scattering cross section, and the backscatter phase function, are derived from the two-channel measurements.

Shipley, S. T.↗

A pressure scanning Fabry-Perot magnetometer.

Description of an oscillating magnetic analyzer (KDP crystal plus Glan-Thompson prism) coupled to an echelle-interferometer spectrograph, and of single-slit magnetometer which by pressure variations can be made to scan the entire profiles of the circularly and linearly polarized Zeeman components. Freon gas is used as the scanner gas with wavelength displacements of 0.02 A per 0.1 in. Hg pressure change at the NaD lines. The available scan range is 15 A in the visual spectral region.

Fay, T. D.↗

Application of Fabry-perot Spectrometers for Measurement of Upper Atmosphere Temperatures and Winds

The mechanisms giving rise to certain airglow and auroral emissions and their height distribution are briefly surveyed. The basic principles of operation of scanning Fabry-Perot spectrometers are outlined in order to illustrate the calibration and use of such instruments to measure Doppler broadening and shift of atomic emission lines in the spectrum of the airglow and aurora and hence to infer atmospheric temperatures and wind velocities. Technical details of some specific instruments are given. Brief mention is made of the use of wide angle Michelson interferometers for the same application. Emphasis is given to the future importance of imaging Fabry-Perot spectrometers to permit the detailed mapping of temperature and wind velocity, especially in the auroral regions.

F Jacka↗

Remote displacement measurement using a passive interferometer with a fiber-optic link

Remote displacement measurement is demonstrated using a Fabry-Perot cavity with a multimode optical fiber link. The sensing cavity modulates, as a function of its length, the spectrum of a light-emitting diode (LED). The light returns via the fiber and is analyzed by a tunable reference cavity. A closed-loop control causes the reference cavity to track the sensing cavity length within 2 x 10 to the -12th m. Displacement range is 2 x 10 to the -6th m. The reference cavity length is measured interferometrically, using a laser, to obtain the sensing cavity length. Advantages of this sensing technique include compatibility with multimode fiber-optic components, high immunity to optical losses, and large dynamic range.

Beheim, G.↗

Infrared Fabry-Perot and heterodyne spectrometers

The status of infrared instrumentation for astronomical investigations at U.C. Berkeley is described with emphasis on the techniques of high spectral and spatial resolution. Present instrumentation includes three Fabry-Perot spectrometers for the 10, 20, and 100 micron wavelength regions, a submillimeter receiver using an optically pumped laser, a 10 micron heterodyne spectrometer for studies of planetary atmospheres, and a 2-element 10 micron stellar interferometer for measuring the angular diameters of infrared stars.

Betz, A.↗