Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUOROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Minilaparotomy-Assisted Transmesenteric-Transjugular Intrahepatic Portosystemic Shunt: Comparison with Conventional Transjugular Approach

PurposeThis study was performed to compare the intrahepatic shunt function outcome and procedural complications of minilaparotomy-assisted transmesenteric (MAT)-transjugular intrahepatic portosystemic shunt (TIPS) placement with the conventional transjugular method.MethodsThis is a retrospective review of all patients who had a MAT or conventional TIPS procedure over a 6-year period at our institute. The primary patency rate, fluoroscopy time, technical success, major procedure-related complications, and mortality data were compared between two treatment groups.ResultsWe included 49 patients with MAT-TIPS, and 63 with conventional TIPS, with an average follow-up of 21.43 months. The primary patency rates at 6 and 12 months were 82.9 and 66.7 % in the conventional TIPS group, and 81.0 and 76.5 % in the MAT-TIPS group (p = 1.000, and 0.529), respectively. There was no significant difference in technical success rate, post-procedure portosystemic pressure gradient, fluoroscopy time, and peri-procedural mortality rate between treatment groups. Major procedural-related complications were seen more frequently among MAT-TIPS patients (p = 0.012). In the MAT-TIPS group, 5 (10.2 %) patients developed post-procedure minilaparotomy, wound-related complications, and 5 (10.2 %) developed bacterial peritonitis; whereas, none of patients with conventional TIPS had either of these complications (p = 0.014).ConclusionWhile both MAT-TIPS and conventional TIPS had similar shunt primary patency rate and technical success rate, the MAT approach was associated with a significantly higher rate of minilaparotomy-related wound complications or infectious complications. These complications maybe prevented by a change in post-procedure monitoring and therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robotic-Assisted Versus Manual Prostatic Arterial Embolization for Benign Prostatic Hyperplasia: A Comparative Analysis

PurposeProstatic artery embolization (PAE) is a safe and efficacious procedure for benign prostatic hyperplasia (BPH), though is technically challenging. We present our experience of technical and clinical outcomes of robotic and manual PAE in patients with BPH.Materials and MethodsIRB-approved retrospective study of 40 consecutive patients 49–81 years old with moderate or severe grade BPH from May 2014 to July 2015: 20 robotic-assisted PAE (group 1), 20 manual PAE (group 2). Robotic-assisted PAE was performed using the Magellan Robotic System. American Urological Association (AUA-SI) score, cost, technical and clinical success, radiation dose, fluoroscopy, and procedure time were reviewed. Statistical analysis was performed within and between each group using paired t test and one-way analysis of variance respectively, at 1 and 3 months.ResultsNo significant baseline differences in age and AUA-SI between groups. Technical success was 100% (group 1) and 95% (group 2). One unsuccessful subject from group 2 returned for a successful embolization using robotic assistance. Fluoroscopy and procedural times were similar between groups, with a non-significant lower patient radiation dose in group 1 (30,632.8 mGy/cm{sup 2} vs 35,890.9, p = 0.269). Disposable cost was significantly different between groups with the robotic-assisted PAE incurring a higher cost (group 1 $4530.2; group 2 $1588.5, p < 0.0001). Clinical improvement was significant in both arms at 3 months: group 1 mean change in AUA-SI of 8.3 (p = 0.006), group 2: 9.6 (p < 0.0001). No minor or major complications occurred.ConclusionsRobotic-assisted PAE offers technical success comparable to manual PAE, with similar clinical improvement with an increased cost.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Method of Adrenal Venous Sampling via an Antecubital Approach

PurposeCurrently, almost all adrenal venous sampling (AVS) procedures are performed by femoral vein access. The purpose of this study was to establish the technique of AVS via an antecubital approach and evaluate its safety and feasibility.Materials and MethodsFrom January 2012 to June 2015, 194 consecutive patients diagnosed as primary aldosteronism underwent AVS via an antecubital approach without ACTH simulation. Catheters used for bilateral adrenal cannulations were recorded. The success rate of bilateral adrenal sampling, operation time, fluoroscopy time, dosage of contrast, and incidence of complications were calculated.ResultsA 5F MPA1 catheter was first used to attempt right adrenal cannulation in all patients. Cannulation of the right adrenal vein was successfully performed in 164 (84.5%) patients. The 5F JR5, Cobra2, and TIG catheters were the ultimate catheters for right adrenal cannulation in 16 (8.2%), 5 (2.6%), and 9 (4.6%) patients, respectively. For left adrenal cannulation, JR5 and Cobra2 catheters were used in 19 (9.8%) and 10 (5.2%) patients, respectively, while only TIG catheters were used in the remaining 165 (85.1%) patients. The rate of successful adrenal sampling on the right, left, and bilateral sides was 91.8%, 93.3%, and 87.6%, respectively. The mean time of operation was (16.3 ± 4.3) minutes, mean fluoroscopy time was (4.7 ± 1.3) minutes, and the mean use of contrast was (14.3 ± 4.7) ml. The incidence of adrenal hematoma was 1.0%.ConclusionsThis study showed that AVS via an antecubital approach was safe and feasible, with a high rate of successful sampling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrasound-Guided Angioplasty of Dysfunctional Vascular Access for Haemodialysis. The Pros and Cons

PurposeTo describe the benefits and the disadvantages of angioplasty in dialysis fistulas using only ultrasound guidance.Materials and MethodsThis is a prospective study in 132 failing or non-maturing arteriovenous accesses that underwent 189 ultrasound-guided balloon angioplasties. The technical success was defined as non-use of X-ray fluoroscopy during the procedure.Results127 procedures (67%) were successfully completed without fluoroscopy. Most failures were due to difficulty to traverse aneurismal segments, as well as anastomotic stenoses. Including initial failures, the primary patency rates at 6, 12 months and 2 years were 75 ± 3, 41 ± 3 and 14 ± 2%, respectively.ConclusionEndovascular repair of the dysfunctional vascular access for haemodialysis under ultrasound guidance is feasible and safe in roughly two-thirds of cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Usefulness of Virtual Fluoroscopic Preprocedural Planning During Percutaneous Transhepatic Biliary Drainage

Purpose To retrospectively evaluate the usefulness of virtual fluoroscopic preprocedural planning (VFPP) in the percutaneous transhepatic biliary drainage (PTBD) procedure.Materials and MethodsTwenty-two patients who were treated by PTBD were included in this study. Twelve patients were treated using PTBD intraoperative referencing coronal computed tomography (CT) images (i.e., coronal CT group), and ten patients were treated using PTBD intraoperative referencing VFPP images (i.e., VFPP group). To analyze the effect of the intraoperative referencing VFPP image, the VFPP group was retrospectively compared with the coronal CT group.ResultsThe characteristics of both patient groups were not statistically significantly different. There were no significant differences in the targeted bile duct, diameter and depth of the target bile, breath-holding ability, number of targeted bile duct puncture attempts, change in the targeted bile duct, and exchange of the drainage catheter. However, the X-ray fluoroscopy time and the procedure time were significantly shorter in the VFPP group than in the coronal CT group (196 vs. 334 s, P < 0.05; and 16.0 vs. 27.2 min, P < 0.05).ConclusionIntraoperative referencing using the VFPP imaging in PTBD intuitively can be a useful tool for better localization of the guidewire in the bile duct and thereby shorten the X-ray fluoroscopy time and procedure time while minimizing radiation exposure and complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hybrid Approach for Biliary Interventions Employing MRI-Guided Bile Duct Puncture with Near-Real-Time Imaging

ObjectiveTo assess the feasibility of a hybrid approach employing MRI-guided bile duct (BD) puncture for subsequent fluoroscopy-guided biliary interventions in patients with non-dilated (≤3 mm) or dilated BD (≥3 mm) but unfavorable conditions for ultrasonography (US)-guided BD puncture.MethodsA total of 23 hybrid interventions were performed in 21 patients. Visualization of BD and puncture needles (PN) in the interventional MR images was rated on a 5-point Likert scale by two radiologists. Technical success, planning time, BD puncture time and positioning adjustments of the PN as well as technical success of the biliary intervention and complication rate were recorded.ResultsVisualization even of third-order non-dilated BD and PN was rated excellent by both radiologists with good to excellent interrater agreement. MRI-guided BD puncture was successful in all cases. Planning and BD puncture times were 1:36 ± 2.13 (0:16–11:07) min. and 3:58 ± 2:35 (1:11–9:32) min. Positioning adjustments of the PN was necessary in two patients. Repeated capsular puncture was not necessary in any case. All biliary interventions were completed successfully without major complications.ConclusionA hybrid approach which employs MRI-guided BD puncture for subsequent fluoroscopy-guided biliary intervention is feasible in clinical routine and yields high technical success in patients with non-dilated BD and/or unfavorable conditions for US-guided puncture. Excellent visualization of BD and PN in near-real-time interventional MRI allows successful cannulation of the BD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transfemoral Venous Access Facilitates Upper Extremity Dialysis Interventions: Procedural Success and Clinical Outcomes

Purpose: To report technical success and clinical outcomes of transfemoral venous access for upper extremity dialysis interventions. Materials and Methods: A total of 15 patients underwent a transfemoral venous approach for fistulography (n = 4; 27%) or thrombectomy (n = 11; 73%) over a 14-month period. Access characteristics, sheath size, thrombectomy method, angioplasty site, fluoroscopy time, radiation dose, technical and clinical success, complications, and post-intervention primary and secondary patency rates were recorded. Results: Access type included arteriovenous fistulas (n = 10; 67%) and grafts (n = 5; 33%). The most common configuration was brachio-brachial (n = 6; 38%). Mean age of access was 37 months. Mean prior interventions were 4. Right CFV access was used in all patients using 6–8-French (most common: 7-French [n = 10; 67%]) sheaths. Most thrombectomies (n = 11; 73%) required both pharmacologic and mechanical maceration (n = 9; 82%). All accesses required angioplasty to treat underlying stenosis at the outflow vein (n = 12; 80%) or arteriovenous anastomosis (n = 9; 90%). Mean fluoroscopy time was 26.43 min. Air kerma and dose area product were 178.06 ± 225.77 mGy and 57,768.83 ± 87,553.29 μGym{sup 2}, respectively. Procedural and clinical success rates were 93% and 80%, respectively. Technical failure was due to persistent stenosis in one patient. Clinical failure was due to unsuccessful dialysis immediately following intervention in three patients. Mean post-intervention primary patency and secondary patency durations were 2.8 and 4.8 months, respectively. Primary patency rates at 1 and 3 months were 50% and 35%, respectively. Secondary patency rates at 1 and 3 months were 58% and 30%, respectively. Conclusion: A transfemoral venous approach for intervention of upper extremity dialysis accesses may be a valuable adjunct to traditional approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Experience with Real-Time 3-D Guidance Based on C-Arm-Acquired Cone-Beam CT (CBCT) in Transjugular Intrahepatic Portosystemic Stent Shunt (TIPSS) Placement

PurposeThe aim of this study was to evaluate the feasibility of cone-beam computed tomography (CBCT)-based real-time 3-D guidance of TIPSS placement and its positioning compared to standard guiding methods.Materials and MethodsIn a prospective, randomized, consecutive study design from 2015 to 2017, we included 21 patients in the CBCT guided group and 15 patients in the ultrasound (US) guided group. The prospective groups were compared in terms of success rate of intervention, portal vein puncture/procedure time, number of puncture attempts and applied dose. We furthermore retrospectively analyzed the last 23 consecutive cases with fluoroscopic guided portal vein puncture in terms of success rate, procedure time and applied dose, as it has been the standard method before US guidance.ResultsThe median number of puncture attempts (CBCT: n = 2, US: n = 4, p = 0.249) and the mean puncture time (CBCT: 32 ± 45 min, US: 36 ± 45 min, p = 0.515) were not significantly different. There were furthermore no significant differences in the mean time needed for the total TIPSS procedure (CBCT: 115 ± 52 min, US: 112 ± 41 min, fluoroscopy: 110 ± 33 min, p = 0.996). The mean applied dose of the complete procedure also showed no statistically significant differences (CBCT: 563 ± 289 Gy·cm{sup 2}, US: 322 ± 186 Gy·cm{sup 2}, fluoroscopy: 469 ± 352 Gy·cm{sup 2}, p = 0.069). There were no image guidance related complications.ConclusionReal-time 3-D needle guidance based on CBCT is feasible for TIPSS placement. In terms of puncture attempts, duration and dose, CBCT guidance was not inferior to the control groups and may be a valuable support for interventionists in TIPSS procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MVP™ Micro Vascular Plug Systems for the Treatment of Pulmonary Arteriovenous Malformations

Purpose: To describe our institutional experience with MVP™ micro vascular plug systems for the treatment of pulmonary arteriovenous malformations (PAVMs). Materials and Methods: We performed a retrospective medical record review of 52 patients with 119 PAVMs treated exclusively with MVP™ systems (69 procedures/153 MVP™ systems) between July 2014 and July 2018. All patients had PAVMs with feeding artery diameters ≥ 2 mm. MVP™ systems were deployed according to physician preference. We collected patient demographic information; procedural data (including size of feeding artery, size and number of embolics used per PAVM, fluoroscopy time, contrast administration), technical success rates, complications, and persistence. Persistence was assessed using computed tomography angiography (CTA) performed 1–3 months and 3–5 years after embolization per clinical protocol. Results: All procedures were technically successful without major complications. Mean feeding artery diameter was 3.3 ± 1.2 mm. Mean fluoroscopy time per procedure and contrast volume administered per procedure were 35 ± 16 min and 217 ± 101 mL, respectively. A mean of 1.3 ± 0.8 MVP™ systems was used per PAVM. There were no instances of persistence during a mean follow-up time of 328 ± 258 days (range 26 to 914 days). Conclusions: For PAVMs with feeding artery diameters of 2 to 7.9 mm (mean 3.3 ± 1.2 mm), MVP™ systems are safe and effective given their high technical success rates and lack of persistence. Further prospective work will be required to elucidate the advantages and disadvantages of these MVP™ systems for PAVM embolization. Level of Evidence: Level III.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Fusion Guidance for In Situ Laser Fenestration of Aortic Stent graft for Endovascular Repair of Complex Aortic Aneurysm: Feasibility, Efficacy and Overall Functional Success

Objective: To evaluate feasibility, efficacy and overall functional success of image fusion guidance during laser-assisted in situ fenestration of aortic stent graft (LISFAS) for endovascular repair of complex aortic aneurysm (complex-EVAR) in a prospective study. Methods: Between September 2016 and July 2018, 20 patients were included and treated with LISFAS for complex-EVAR. Aortic aneurysms were either para-renal (n = 15) or thoraco-abdominal (n = 5) with 57 mm [first quartile: 54; third quartile: 68] median aneurysm diameter in 69 years [68;78] patients. All interventions were performed using the same angiographic system and 3D image fusion software for overlying pre-intervention CTA on per-intervention 2D fluoroscopy with cone-beam CT images to display target vessels ostia. Results: LISFAS for complex-EVAR with image fusion was performed in all patients, and no endovascular intervention required conversion to an open aortic repair. LISFAS of all target vessels was feasible in 18 patients (90%); 48 fenestrations out of 50 were performed successfully. Two fenestrations failed for renal arteries in two patients. Median ischemic times were as follows: 34 min [25;43] for superior mesenteric artery; 69 min [56;83] for left renal artery; 73 min [36;102] for right renal artery; and 93 min [89;96] for the celiac trunk. Median intervention and fluoroscopy times, iodinated contrast volume and X-ray exposure were 180 min [150;180], 74 min [64;87], 80 mL [59;113] and 338 Gy.cm{sup 2} [259;495], respectively. Efficacy was found in 17 patients (85%) on one-week follow-up CTA: Two patients had type 1 and 3 endoleaks, respectively, that were successfully embolized. Overall functional success was 90%. Median hospitalization stay was 9 days [8, 17]. The 30-day safety analysis was 90% (n = 2 deaths) owing to an undetermined cause and to bowel ischemia after low flow in intensive care unit. Conclusions: LISFAS using image fusion was feasible, efficient and overall functionally successful for complex-EVAR in this preliminary study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inferences About Prostate Intrafraction Motion From Pre- and Posttreatment Volumetric Imaging

Purpose: To evaluate the ability of rectal filling, bladder filling, and prostate localization from pre- and posttreatment volumetric imaging to predict prostate intrafraction motion. Methods and Materials: Pre- and posttreatment cone beam computed tomography images (CBCTs) and intrafractional kV fluoroscopy were acquired at each fraction for 20 prostate patients in supine position, totaling 374 fractions available for analysis. Rectal and bladder filling status were evaluated for each CBCT, and correlation with prostate intrafraction motion measured from kV fluoroscopy was performed. The accuracy of pre and posttreatment prostate localization to predict intrafraction motion was evaluated. Results: Rectal filling status was a significant predictor of prostate intrafraction motion (p <0.001), and gas volume was correlated with the maximum vector displacement at MV delivery with a correlation coefficient (cc) of 0.37 and p <0.001. Prostate motion was greater for patients who consistently had gas volume >0.5 cm{sup 3} within the imaged region (cc = 0.52, p = 0.028). A weak relationship was found between bladder filling and posterior prostate drift for fractions with gas volume {<=}0.5 cm{sup 3} (cc = -0.17, p = 0.046). The sensitivity of detecting a 3-, 5-, and 7-mm excursion at MV delivery using posttreatment imaging was 76%, 75%, and 81% respectively. Conclusions: Rectal filling is a significant predictor of prostate intrafraction motion, whereas bladder filling is of limited usefulness. Pre- and posttreatment localization can provide a reasonable estimate of prostate motion during MV delivery when intrafraction localization is not available, with an error of 95% within 3.1 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Effect of Intrafraction Motion and Residual Setup Error for Hypofractionated Prostate Intensity-Modulated Radiotherapy With Online Cone Beam Computed Tomography Image Guidance

Purpose: To quantify the dosimetric effect and margins required to account for prostate intrafractional translation and residual setup error in a cone beam computed tomography (CBCT)-guided hypofractionated radiotherapy protocol. Methods and Materials: Prostate position after online correction was measured during dose delivery using simultaneous kV fluoroscopy and posttreatment CBCT in 572 fractions to 30 patients. We reconstructed the dose distribution to the clinical tumor volume (CTV) using a convolution of the static dose with a probability density function (PDF) based on the kV fluoroscopy, and we calculated the minimum dose received by 99% of the CTV (D{sub 99}). We compared reconstructed doses when the convolution was performed per beam, per patient, and when the PDF was created using posttreatment CBCT. We determined the minimum axis-specific margins to limit CTV D{sub 99} reduction to 1%. Results: For 3-mm margins, D{sub 99} reduction was {<=}5% for 29/30 patients. Using post-CBCT rather than localizations at treatment delivery exaggerated dosimetric effects by {approx}47%, while there was no such bias between the dose convolved with a beam-specific and patient-specific PDF. After eight fractions, final cumulative D{sub 99} could be predicted with a root mean square error of <1%. For 90% of patients, the required margins were {<=}2, 4, and 3 mm, with 70%, 40%, and 33% of patients requiring no right-left (RL), anteroposterior (AP), and superoinferior margins, respectively. Conclusions: For protocols with CBCT guidance, RL, AP, and SI margins of 2, 4, and 3 mm are sufficient to account for translational errors; however, the large variation in patient-specific margins suggests that adaptive management may be beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Randomized Controlled Trial of Lorazepam to Reduce Liver Motion in Patients Receiving Upper Abdominal Radiation Therapy

Purpose: Reduction of respiratory motion is desirable to reduce the volume of normal tissues irradiated, to improve concordance of planned and delivered doses, and to improve image guided radiation therapy (IGRT). We hypothesized that pretreatment lorazepam would lead to a measurable reduction of liver motion. Methods and Materials: Thirty-three patients receiving upper abdominal IGRT were recruited to a double-blinded randomized controlled crossover trial. Patients were randomized to 1 of 2 study arms: arm 1 received lorazepam 2 mg by mouth on day 1, followed by placebo 4 to 8 days later; arm 2 received placebo on day 1, followed by lorazepam 4 to 8 days later. After tablet ingestion and daily radiation therapy, amplitude of liver motion was measured on both study days. The primary outcomes were reduction in craniocaudal (CC) liver motion using 4-dimensional kV cone beam computed tomography (CBCT) and the proportion of patients with liver motion ≤5 mm. Secondary endpoints included motion measured with cine magnetic resonance imaging and kV fluoroscopy. Results: Mean relative and absolute reduction in CC amplitude with lorazepam was 21% and 2.5 mm respectively (95% confidence interval [CI] 1.1-3.9, P=.001), as assessed with CBCT. Reduction in CC amplitude to ≤5 mm residual liver motion was seen in 13% (95% CI 1%-25%) of patients receiving lorazepam (vs 10% receiving placebo, P=NS); 65% (95% CI 48%-81%) had reduction in residual CC liver motion to ≤10 mm (vs 52% with placebo, P=NS). Patients with large respiratory movement and patients who took lorazepam ≥60 minutes before imaging had greater reductions in liver CC motion. Mean reductions in liver CC amplitude on magnetic resonance imaging and fluoroscopy were nonsignificant. Conclusions: Lorazepam reduces liver motion in the CC direction; however, average magnitude of reduction is small, and most patients have residual motion >5 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geometric Verification of Dynamic Wave Arc Delivery With the Vero System Using Orthogonal X-ray Fluoroscopic Imaging

Purpose: The purpose of this study was to define an independent verification method based on on-board orthogonal fluoroscopy to determine the geometric accuracy of synchronized gantry–ring (G/R) rotations during dynamic wave arc (DWA) delivery available on the Vero system. Methods and Materials: A verification method for DWA was developed to calculate O-ring-gantry (G/R) positional information from ball-bearing positions retrieved from fluoroscopic images of a cubic phantom acquired during DWA delivery. Different noncoplanar trajectories were generated in order to investigate the influence of path complexity on delivery accuracy. The G/R positions detected from the fluoroscopy images (DetPositions) were benchmarked against the G/R angulations retrieved from the control points (CP) of the DWA RT plan and the DWA log files recorded by the treatment console during DWA delivery (LogActed). The G/R rotational accuracy was quantified as the mean absolute deviation ± standard deviation. The maximum G/R absolute deviation was calculated as the maximum 3-dimensional distance between the CP and the closest DetPositions. Results: In the CP versus DetPositions comparison, an overall mean G/R deviation of 0.13°/0.16° ± 0.16°/0.16° was obtained, with a maximum G/R deviation of 0.6°/0.2°. For the LogActed versus DetPositions evaluation, the overall mean deviation was 0.08°/0.15° ± 0.10°/0.10° with a maximum G/R of 0.3°/0.4°. The largest decoupled deviations registered for gantry and ring were 0.6° and 0.4° respectively. No directional dependence was observed between clockwise and counterclockwise rotations. Doubling the dose resulted in a double number of detected points around each CP, and an angular deviation reduction in all cases. Conclusions: An independent geometric quality assurance approach was developed for DWA delivery verification and was successfully applied on diverse trajectories. Results showed that the Vero system is capable of following complex G/R trajectories with maximum deviations during DWA below 0.6°.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hybrid x-ray/optical luminescence imaging: Characterization of experimental conditions

Purpose: The feasibility of x-ray luminescence imaging is investigated using a dual-modality imaging system that merges x-ray and optical imaging. This modality utilizes x-ray activated nanophosphors that luminesce when excited by ionizing photons. By doping phosphors with lanthanides, which emit light in the visible and near infrared range, the luminescence is suitable for biological applications. This study examines practical aspects of this new modality including phosphor concentration, light emission linearity, detector damage, and spectral emission characteristics. Finally, the contrast produced by these phosphors is compared to that of x-ray fluoroscopy. Methods: Gadolinium and lanthanum oxysulfide phosphors doped with terbium (green emission) or europium (red emission) were studied. The light emission was imaged in a clinical x-ray scanner with a cooled CCD camera and a spectrophotometer; dose measurements were determined with a calibrated dosimeter. Using these properties, in addition to luminescence efficiency values found in the literature for a similar phosphor, minimum concentration calculations are performed. Finally, a 2.5 cm agar phantom with a 1 cm diameter cylindrical phosphor-filled inclusion (diluted at 10 mg/ml) is imaged to compare x-ray luminescence contrast with x-ray fluoroscopic contrast at a superficial location. Results: Dose to the CCD camera in the chosen imaging geometry was measured at less than 0.02 cGy/s. Emitted light was found to be linear with dose (R{sup 2}=1) and concentration (R{sup 2}=1). Emission peaks for clinical x-ray energies are less than 3 nm full width at half maximum, as expected from lanthanide dopants. The minimum practical concentration necessary to detect luminescent phosphors is dependent on dose; it is estimated that subpicomolar concentrations are detectable at the surface of the tissue with typical mammographic doses, with the minimum detectable concentration increasing with depth and decreasing with dose. In a reflection geometry, x-ray luminescence had nearly a 430-fold greater contrast to background than x-ray fluoroscopy. Conclusions: X-ray luminescence has the potential to be a promising new modality for enabling molecular imaging within x-ray scanners. Although much work needs to be done to ensure biocompatibility of x-ray exciting phosphors, the benefits of this modality, highlighted in this work, encourage further study.

60 APPLIED LIFE SCIENCES↗

Calibration-free device sizing using an inverse geometry x-ray system

Purpose: Quantitative coronary angiography (QCA) can be used to support device size selection for cardiovascular interventions. The accuracy of QCA measurements using conventional x-ray fluoroscopy depends on proper calibration using a reference object and avoiding vessel foreshortening. The authors have developed a novel interventional device sizing method using the inverse geometry scanning-beam digital x-ray (SBDX) fluoroscopy system. The proposed method can measure the diameter and length of vessel segments without imaging a reference object and when vessels appear foreshortened. Methods: SBDX creates multiple tomosynthetic x-ray images corresponding to planes through the patient volume. The structures that lie in the plane are in focus and the features above and below the plane are blurred. Three-dimensional localization of the vessel edges was performed by examining the degree of blurring at each image plane. A 3D vessel centerline was created and used to determine vessel magnification and angulation relative to the image planes. Diameter measurements were performed using a model-based method and length measurements were calculated from the 3D centerline. Phantom validation was performed by measuring the diameter and length of vessel segments with nominal diameters ranging from 0.5 to 2.8 mm and nominal lengths of 42 mm. The phantoms were imaged at a range of positions between the source and the detector ({+-}16 cm relative to isocenter) and with a range of foreshortening angles (0 deg. - 75 deg.). Results: Changes in vessel phantom position created magnifications ranging from 87% to 118% relative to isocenter magnification. Average diameter errors were less than 0.15 mm. Average length measurements were within 1% (0.3 mm) of the true length. No trends were observed between measurement accuracy and magnification. Changes in vessel phantom orientation resulted in decreased apparent length down to 28% of the original nonforeshortened length. Average diameter errors were less than 0.25 mm across all vessel angulations; errors were less than 0.1 mm for smaller diameter vessels and low to moderate vessel angles. Diameter errors increased with true diameter and vessel angle relative to the image plane. Average length measurement errors were also within 1% (0.3 mm) for each angulation. Conclusions: Tomosynthetic imaging with SBDX can accurately measure dimensions of vessels in various magnifications and angulations without calibration. This method may be more accurate and convenient than conventional QCA techniques.

60 APPLIED LIFE SCIENCES↗

Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance

Purpose: A flat-panel detector based mobile isocentric C-arm for cone-beam CT (CBCT) has been developed to allow intraoperative 3D imaging with sub-millimeter spatial resolution and soft-tissue visibility. Image quality and radiation dose were evaluated in spinal surgery, commonly relying on lower-performance image intensifier based mobile C-arms. Scan protocols were developed for task-specific imaging at minimum dose, in-room exposure was evaluated, and integration of the imaging system with a surgical guidance system was demonstrated in preclinical studies of minimally invasive spine surgery. Methods: Radiation dose was assessed as a function of kilovolt (peak) (80-120 kVp) and milliampere second using thoracic and lumbar spine dosimetry phantoms. In-room radiation exposure was measured throughout the operating room for various CBCT scan protocols. Image quality was assessed using tissue-equivalent inserts in chest and abdomen phantoms to evaluate bone and soft-tissue contrast-to-noise ratio as a function of dose, and task-specific protocols (i.e., visualization of bone or soft-tissues) were defined. Results were applied in preclinical studies using a cadaveric torso simulating minimally invasive, transpedicular surgery. Results: Task-specific CBCT protocols identified include: thoracic bone visualization (100 kVp; 60 mAs; 1.8 mGy); lumbar bone visualization (100 kVp; 130 mAs; 3.2 mGy); thoracic soft-tissue visualization (100 kVp; 230 mAs; 4.3 mGy); and lumbar soft-tissue visualization (120 kVp; 460 mAs; 10.6 mGy) - each at (0.3 x 0.3 x 0.9 mm{sup 3}) voxel size. Alternative lower-dose, lower-resolution soft-tissue visualization protocols were identified (100 kVp; 230 mAs; 5.1 mGy) for the lumbar region at (0.3 x 0.3 x 1.5 mm{sup 3}) voxel size. Half-scan orbit of the C-arm (x-ray tube traversing under the table) was dosimetrically advantageous (prepatient attenuation) with a nonuniform dose distribution ({approx}2 x higher at the entrance side than at isocenter, and {approx}3-4 lower at the exit side). The in-room dose (microsievert) per unit scan dose (milligray) ranged from {approx}21 {mu}Sv/mGy on average at tableside to {approx}0.1 {mu}Sv/mGy at 2.0 m distance to isocenter. All protocols involve surgical staff stepping behind a shield wall for each CBCT scan, therefore imparting {approx}zero dose to staff. Protocol implementation in preclinical cadaveric studies demonstrate integration of the C-arm with a navigation system for spine surgery guidance-specifically, minimally invasive vertebroplasty in which the system provided accurate guidance and visualization of needle placement and bone cement distribution. Cumulative dose including multiple intraoperative scans was {approx}11.5 mGy for CBCT-guided thoracic vertebroplasty and {approx}23.2 mGy for lumbar vertebroplasty, with dose to staff at tableside reduced to {approx}1 min of fluoroscopy time ({approx}40-60 {mu}Sv), compared to 5-11 min for the conventional approach. Conclusions: Intraoperative CBCT using a high-performance mobile C-arm prototype demonstrates image quality suitable to guidance of spine surgery, with task-specific protocols providing an important basis for minimizing radiation dose, while maintaining image quality sufficient for surgical guidance. Images demonstrate a significant advance in spatial resolution and soft-tissue visibility, and CBCT guidance offers the potential to reduce fluoroscopy reliance, reducing cumulative dose to patient and staff. Integration with a surgical guidance system demonstrates precise tracking and visualization in up-to-date images (alleviating reliance on preoperative images only), including detection of errors or suboptimal surgical outcomes in the operating room.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Patient radiation doses in interventional cardiology in the U.S.: Advisory data sets and possible initial values for U.S. reference levels

Purpose: To determine patient radiation doses from interventional cardiology procedures in the U.S and to suggest possible initial values for U.S. benchmarks for patient radiation dose from selected interventional cardiology procedures [fluoroscopically guided diagnostic cardiac catheterization and percutaneous coronary intervention (PCI)]. Methods: Patient radiation dose metrics were derived from analysis of data from the 2008 to 2009 Nationwide Evaluation of X-ray Trends (NEXT) survey of cardiac catheterization. This analysis used deidentified data and did not require review by an IRB. Data from 171 facilities in 30 states were analyzed. The distributions (percentiles) of radiation dose metrics were determined for diagnostic cardiac catheterizations, PCI, and combined diagnostic and PCI procedures. Confidence intervals for these dose distributions were determined using bootstrap resampling. Results: Percentile distributions (advisory data sets) and possible preliminary U.S. reference levels (based on the 75th percentile of the dose distributions) are provided for cumulative air kerma at the reference point (K{sub a,r}), cumulative air kerma-area product (P{sub KA}), fluoroscopy time, and number of cine runs. Dose distributions are sufficiently detailed to permit dose audits as described in National Council on Radiation Protection and Measurements Report No. 168. Fluoroscopy times are consistent with those observed in European studies, but P{sub KA} is higher in the U.S. Conclusions: Sufficient data exist to suggest possible initial benchmarks for patient radiation dose for certain interventional cardiology procedures in the U.S. Our data suggest that patient radiation dose in these procedures is not optimized in U.S. practice.

07 ISOTOPE AND RADIATION SOURCES↗