Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Monitoring a large-volume injection at Cranfield, Mississippi—Project design and recommendations (SECARB Integrated Results Study)

Injection and storage of 4 million metric tons of CO 2 have been monitored to observe multiphase fluid flow, to test technologies, to document permanence of storage, and to advance techniques for capacity estimation. The injection interval is the 3000-m-deep fluvial Tuscaloosa Formation at a structural closure that defines the Cranfield oilfield. Tests were conducted in the oil-producing area as well as in the downdip brine aquifer. These tests assessed the feasibility, operation, and sensitivity ofmonitoring using a selection oftools in the vadose zone, in the shallow groundwater, above the injection zone, and within the injection zone. Although each monitoring approach merits a separate, detailed analysis, this paper assesses the success of the overall strategy for monitoring and presents an overview of conclusions from multiple data sets. Comparisons of modeled to observed reservoir response highlight the difficulties encountered in uniquely explaining measured pressure and fluid saturation measurements at interwell and field scales. Results of this study provide a cautionary note to regulatory and accreditation end users about the feasibility of obtaining unique and quantitative matches between fluid flow models and field measurements.

54 ENVIRONMENTAL SCIENCES↗

A conceptual geochemical model of the geothermal system at Surprise Valley, CA

Characterizing the geothermal system at Surprise Valley (SV), northeastern California, is important for determining the sustainability of the energy resource, and mitigating hazards associated with hydrothermal eruptions that last occurred in 1951. Previous geochemical studies of the area attempted to reconcile different hot spring compositions on the western and eastern sides of the valley using scenarios of dilution, equilibration at low temperatures, surface evaporation, and differences in rock type along flow paths. These models were primarily supported using classical geothermometry methods, and generally assumed that fluids in the Lake City mud volcano area on the western side of the valley best reflect the composition of a deep geothermal fluid. In this contribution, we address controls on hot spring compositions using a different suite of geochemical tools, including optimized multicomponent geochemistry (GeoT) models, hot spring fluid major and trace element measurements, mineralogical observations, and stable isotope measurements of hot spring fluids and precipitated carbonates. We synthesize the results into a conceptual geochemical model of the Surprise Valley geothermal system, and show that high-temperature (quartz, Na/K, Na/K/Ca) classical geothermometers fail to predict maximum subsurface temperatures because fluids re-equilibrated at progressively lower temperatures during outflow, including in the Lake City area. We propose a model where hot spring fluids originate as a mixture between a deep thermal brine and modern meteoric fluids, with a seasonally variable mixing ratio. The deep brine has deuterium values at least 3 to 4‰ lighter than any known groundwater or high-elevation snow previously measured in and adjacent to SV, suggesting it was recharged during the Pleistocene when meteoric fluids had lower deuterium values. The deuterium values and compositional characteristics of the deep brine have only been identified in thermal springs and groundwater samples collected in proximity to structures that transmit thermal fluids, suggesting the brine may be thermal in nature. On the western side of the valley at the Lake City mud volcano, the deep brine-meteoric water mixture subsequently boils in the shallow subsurface, precipitates calcite, and re-equilibrates at about 130 °C. On the eastern side of the valley, meteoric fluid mixes to a greater extent with the deep brine, cools conductively without boiling, and the composition is modified as dissolved elements are sequestered by secondary minerals that form along the cooling and outflow path at temperatures <130 °C. Re-equilibration of geothermal fluids at lower temperatures during outflow explains why subsurface temperature estimates based on classical geothermometry methods are highly variable, and fail to agree with temperature estimates based on dissolved sulfate-oxygen isotopes and results of classical and multicomponent geothermometry applied to reconstructed deep well fluids. Furthermore, the proposed model is compatible with the idea suggested by others that thermal fluids on the western and eastern side of the valley have a common source, and supports the hypothesis that low temperature re-equilibration during west to east flow is the major control on hot spring fluid compositions, rather than dilution, evaporation, or differences in rock type.

15 GEOTHERMAL ENERGY↗

Simultaneous real-time measurement of composition, flow, attenuation, density, and pipe-wallthickness in multiphase fluids

Apparatus (10) and methods for making simultaneous measurements of composition (water-cut), fluid flow, and sound attenuation in a multiphase fluid flowing (15) through a pipe (12) in real-time, using the same apparatus (10) are described. Additionally, the apparatus (10) provides real-time pipe wall thickness monitoring for observing pipe corrosion or internal deposition. Knowledge of wall thickness is necessary to correct for water-cut (oil-water composition) automatically by adjusting the liquid path length internal to the pipe (spool). The use of short duration frequency chirp excitation signals (24) enables the apparatus to provide information that can be used to extract multiple levels of information from the same measurement in multiphase fluids including the presence of a significant quantity of gas (˜60% gas volume fraction) in different flow regimes. Besides measuring steady flow, this device is useful for measurements during fast changing flows, such as for a rod-pumped well. Measurements up to about 1000 times a second can reliably be made.

Sinha, Dipen N.↗

Diagnostic system for measuring temperature, pressure, CO.sub.2 concentration and H.sub.2O concentration in a fluid stream

A diagnostic system for measuring temperature, pressure, CO.sub.2 concentration and H.sub.2O concentration in a fluid stream is described. The system may include one or more probes that sample the fluid stream spatially, temporally and over ranges of pressure and temperature. Laser light sources are directed down pitch optical cables, through a lens and to a mirror, where the light sources are reflected back, through the lens to catch optical cables. The light travels through the catch optical cables to detectors, which provide electrical signals to a processer. The processer utilizes the signals to calculate CO.sub.2 concentration based on the temperatures derived from H.sub.2O vapor concentration. A probe for sampling CO.sub.2 and H.sub.2O vapor concentrations is also disclosed. Various mechanical features interact together to ensure the pitch and catch optical cables are properly aligned with the lens during assembly and use.

42 ENGINEERING↗

Integrated acoustic phase separator and multiphase fluid composition monitoring apparatus and method

An apparatus and method for down hole gas separation from the multiphase fluid flowing in a wellbore or a pipe, for determining the quantities of the individual components of the liquid and the flow rate of the liquid, and for remixing the component parts of the fluid after which the gas volume may be measured, without affecting the flow stream, are described. Acoustic radiation force is employed to separate gas from the liquid, thereby permitting measurements to be separately made for these two components; the liquid (oil/water) composition is determined from ultrasonic resonances; and the gas volume is determined from capacitance measurements. Since the fluid flows around and through the component parts of the apparatus, there is little pressure difference, and no protection is required from high pressure differentials.

42 ENGINEERING↗

Integrated acoustic phase separator and multiphase fluid composition monitoring apparatus and method

An apparatus and method for down hole gas separation from the multiphase fluid flowing in a wellbore or a pipe, for determining the quantities of the individual components of the liquid and the flow rate of the liquid, and for remixing the component parts of the fluid after which the gas volume may be measured, without affecting the flow stream, are described. Acoustic radiation force is employed to separate gas from the liquid, thereby permitting measurements to be separately made for these two components; the liquid (oil/water) composition is determined from ultrasonic resonances; and the gas volume is determined from capacitance measurements. Since the fluid flows around and through the component parts of the apparatus, there is little pressure difference, and no protection is required from high pressure differentials.

42 ENGINEERING↗

Design and performance of a variable gap system for thermal conductivity measurements of high temperature, corrosive, and reactive fluids

We report high-temperature fluids such as molten salts, liquid metals, and gasses are being proposed for many advanced energy systems including thermal energy storage devices, concentrating solar plants, and advanced nuclear reactor designs. However, the chemical behavior and thermophysical properties of many of these fluids have not been well characterized, which hinders the design, modeling, safety analysis, and deployment of these systems. Thermal conductivity is a property that is especially limited by existing measurement capabilities, which are subject to errors caused by convection, material interaction, radiative heat transfer, and instrument degradation. Therefore, there is a lack of standard, systematic measurement techniques for high-temperature, reactive, and corrosive fluids. In this work, the development of a variable gap thermal conductivity measurement system is detailed. The system is designed to measure the thermal conductivity of highly corrosive and reactive fluids, and survive operation between 100 °C and 800 °C. The effects of convection are minimized by limiting the thickness of the specimen to thin sizes (<0.3 mm). Corrections for radiative heat transfer were included in the working equations to consider specimens with varying optical properties. The design, construction, instrumentation, operating principles, and data analysis techniques are discussed in detail. The system was tested up to 500 °C using helium gas and molten KNO 3 -NaNO 3 to verify the measurement technique and determine the sources of error. At 300 and 400 °C KNO 3 -NaNO 3 , results showed maximum relative error of 6% when compared to results in the literature. The helium results were within 13% of those in the literature at 300 and 400 °C. Higher errors were observed at 500 °C for both fluids, and the sources of these errors are discussed.

42 ENGINEERING↗

Measuring the cross section of the N 15 ( α , γ ) 19 F reaction using a single-fluid bubble chamber

15 N(α, γ) 19 F is believed to be the primary means of stellar nucleosynthesis of fluorine. Here we present the use of a single-fluid bubble chamber to measure the cross section of the time-inverse photo-dissociation reaction. The method benefits from a luminosity increase of several orders of magnitude due to the use of a thicker liquid target - compared to thin films or gas targets - and from the reciprocity theorem. We discuss the results of experiments at the Thomas Jefferson National Accelerator Facility, where the cross section of the photodisintegration process 19 F(γ, α) 15 N was measured by bombarding a superheated fluid of C 3 F 8 with bremsstrahlung γ rays produced by impinging a 4 - 5.5 MeV electron beam on a Cu radiator. From the photodissociation yield the cross section was extracted by performing a convolution with a Monte Carlo–generated γ-ray beam spectrum. The measurement produced a cross section that was then time inverted using the reciprocity theorem. The cross section for the 15 N(α, γ) 19 F reaction was determined down to a value in the range of hundreds of picobarns. We report that with further improvements of the experimental setup the technique could potentially push cross section measurements down to the single picobarn range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intrinsic momentum generation by a combined neoclassical and turbulence mechanism in diverted DIII-D plasma edge

Fluid Reynolds stress from turbulence has usually been considered to be responsible for the anomalous toroidal momentum transport in tokamak plasma. Experiment by Müller et al. [Phys. Rev. Lett. 106, 115001 (2011)], however, reported that neither the observed edge rotation profile nor the inward momentum transport phenomenon at the edge region of an H-mode plasma could be explained by the fluid Reynolds stress measured with reciprocating Langmuir-probe. The full-function gyrokinetic code XGC1 is used to explain, for the first time, Müller et al.'s experimental observations. It is discovered that, unlike in the plasma core, the fluid Reynolds stress from turbulence is not sufficient for momentum transport physics in plasma edge. The “turbulent neoclassical” physics arising from the interaction between kinetic neoclassical orbit dynamics and plasma turbulence is key in the tokamak edge region across the plasma pedestal into core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sensing of fluid viscoelasticity from piezoelectric actuation of cantilever flexural vibration

An experimental method is proposed to measure the rheological properties of fluids. The effects of fluids on the vibration actuated by piezoelectric patches were analyzed and used in measuring viscoelastic properties. Fluid-structure interactions induced changes in the beam vibration properties and frequency-dependent variations of the complex wavenumber of the beam structure were used in monitoring these changes. To account for the effects of fluid-structure interaction, fluids were modelled as a simple viscoelastic support at one end of the beam. The measured properties were the fluid’s dynamic shear modulus and loss tangent. Using the proposed method, the rheological properties of various non-Newtonian fluids were measured. The frequency range for which reliable viscoelasticity results could be obtained was 10–400 Hz. Viscosity standard fluids were tested to verify the accuracy of the proposed method, and the results agreed well with the manufacturer’s reported values. The simple proposed laboratory setup for measurements was flexible so that the frequency ranges of data acquisition were adjustable by changing the beam’s mechanical properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pahute Mesa Well Development and Testing Analyses for Wells ER-20-7, ER-20-8 #2, and ER-EC-11, Revision 1

This report analyzes the following data collected from ER-20-7, ER-20-8 No.2, and ER-EC-11 during WDT operations: (1) Chemical indicators of well development (Section 2.0); (2) Static hydraulic head (Section 3.0); (3) Radiochemistry and geochemistry (Section 4.0); (4) Drawdown observed at locations distal to the pumping well (Section 5.0); and (5) Drilling water production, flow logs, and temperature logs (Section 6.0). The new data are further considered with respect to existing data as to how they enhance or change interpretations of groundwater flow and transport, and an interim small-scale conceptual model is also developed and compared to Phase I concepts. The purpose of well development is to remove drilling fluids and drilling-associated fines from the formation adjacent to a well so samples reflecting ambient groundwater water quality can be collected, and to restore hydraulic properties near the well bore. Drilling fluids can contaminate environmental samples from the well, resulting in nonrepresentative measurements. Both drilling fluids and preexisting fines in the formation adjacent to the well can impede the flow of water from the formation to the well, creating artifacts in hydraulic response data measured in the well.

54 ENVIRONMENTAL SCIENCES↗

X-ray Doppler Velocimetry for Diagnosis of Fluid Motion in ICF Implosions

Paper describes development of a novel diagnostic for measurement of bulk fluid motion in materials that is particularly applicable to very hot, x-ray emitting plasmas in the High Energy Density Physics (HEDP) regime. The X-ray Doppler Velocimetry technique relies on monochromatic imaging in multiple x-ray energy bands near the center of an x-ray emission line in a plasma, and utilizes bent imaging crystals. Higher energy bands are preferentially sensitive to plasma moving towards the viewer, while lower energy bands are preferentially sensitive to plasma moving away from the viewer. Combining multiple images in different energy bands allows for a reconstruction of the fluid velocity field integrated along the line of sight. This paper reviews the technique and discusses progress towards benchmarking the technique with proof-of-principle HEDP experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fluid dynamic design and experimental study of an aspirated temperature measurement platform used in climate observation

Due to the solar radiation effect, current air temperature sensors inside a thermometer screen or radiation shield may produce measurement errors that are 0.8 °C or higher. To improve the observation accuracy, an aspirated temperature measurement platform is designed. A computational fluid dynamics (CFD) method is implemented to analyze and calculate the radiation error of the aspirated temperature measurement platform under various environmental conditions. Then, a radiation error correction equation is obtained by fitting the CFD results using a genetic algorithm (GA) method. In order to verify the performance of the temperature sensor, the aspirated temperature measurement platform, temperature sensors with a naturally ventilated radiation shield, and a thermometer screen are characterized in the same environment to conduct the intercomparison. The average radiation errors of the sensors in the naturally ventilated radiation shield and the thermometer screen are 0.44 °C and 0.25 °C, respectively. In contrast, the radiation error of the aspirated temperature measurement platform is as low as 0.05 °C. This aspirated temperature sensor allows the radiation error to be reduced by approximately 88.6% compared to the naturally ventilated radiation shield, and allows the error to be reduced by a percentage of approximately 80% compared to the thermometer screen. The mean absolute error and root mean square error between the correction equation and experimental results are 0.032 °C and 0.036 °C, respectively, which demonstrates the accuracy of the CFD and GA methods proposed in this research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transient evolution of permeability and friction in a slowly slipping fault activated by fluid pressurization

The mechanisms of permeability and friction evolution in a natural fault are investigated in situ. During three fluid injection experiments at different places in a fault zone, we measured simultaneously the fluid pressure, fault displacements and seismic activity. Changes in fault permeability and friction are then estimated concurrently. Results show that fault permeability increases up to 1.58 order of magnitude as a result of reducing effective normal stress and cumulative dilatant slip, and 19-to-60.8% of the enhancement occurs without seismic emissions. When modeling the fault displacement, we found that a rate-and-state friction and a permeability dependent on both slip and slip velocity together reasonably fit the fault-parallel and fault-normal displacements. This leads to the conclusion that the transient evolution of fault permeability and friction caused by a pressure perturbation exerts a potentially dominant control on fault stability during fluid flow.

58 GEOSCIENCES↗

Runaway electron plateau current profile reconstruction from synchrotron imaging and Ar-II line polarization angle measurements in DIII-D

Abstract Current profile reconstructions are obtained for high current ( I p ≃ 550 kA) post-disruption runaway electron (RE) plateau plasmas in DIII-D. Two novel methods of measuring the RE current profile in high-current RE plateaus are introduced and compared: localization of the q = 2 rational surface using visible synchrotron emission (SE) imaging and the measurement of the polarization angle of line-integrated Ar-II line emission. The two methods are found to be consistent with each other within the data uncertainties. Different simulations of the RE current profile are compared with the measurements: the toroidal fluid RE model is found to best fit the data, within the measurement uncertainties. In addition to introducing two novel methods to measure the RE current profile and validating present simulation capabilities, this work demonstrates that instabilities can grow at q = 2 and q = 1 surfaces without necessarily causing a RE final loss instability. Numerical simulations are also presented to elucidate the role of these instabilities on synchrotron emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of Neutron Imaging to InvestigateFlow Through Fractures for EGS

This paper will describe ongoing efforts at Oak Ridge National Laboratory to develop a unique experimental capability for investigating flow through porous and fractured geological media using neutron imaging techniques. This capability is expected to support numerous areas of investigation associated with flow processes relevant to EGS including, but not limited to: experimental visualization and measurement of velocity profiles and other flow characteristics to better inform reduced-order modeling of flow through fractures; laboratory scale validation of flow models and simulators; and a 'real-time' tool for studying geochemical rock/fluid interactions by noninvasively measuring material effects such as precipitation and dissolution in EGS representative conditions. Neutron scattering and attenuation based techniques have many distinctive advantages over other radiographic imaging methods for studying certain types of physical processes because cold and thermal neutrons are more highly attenuated by materials with large Hydrogen compositions while they more easily penetrate higher Z materials, such as those used in structural applications. Experiments exploiting this behavior may therefore be devised to study flow behaviors in samples even when thick pressure vessel walls and large sample masses are present. The objective of this project is to develop an experimental setup and methodology for taking EGS representative core samples with engineered fractures and fracture features, subjecting them to a triaxial stress state at EGS representative temperatures (up to 300 degrees C), and pumping high pressure fluid through the sample while imaging and measuring fluid flow characteristics using high flux neutron beams. This effort will take advantage of signature Oak Ridge National Laboratory facilities, including the Spallation Neutron Source and High Flux Isotope Reactor, as well as its core expertise in Neutron Science. Towards this end, a geothermal pressure test cell and flow system has been developed that can accommodate 1.5 diameter, 6 long core samples and apply a radial confining pressure up to 10,000 psi with fluid flow pressures up to 5,000 psi. This cell has been specially designed to optimize the transmission of neutrons and permit improved imaging of the interior of the sample of interest. Proof of principle measurements of the system have been performed and will be discussed in this paper. Techniques for injecting fluid contrast agents to permit visualization and quantification of flow profiles are also being developed and will be described along with future development plans.

Polsky, Yarom↗

Completion Report for Well ER-2-2 Corrective Action Unit 97: Yucca Flat/Climax Mine, Revision 1

Well ER-2-2 was drilled for the U.S. Department of Energy, Nevada National Security Administration Nevada Field Office in support of the Underground Test Area (UGTA) Activity. The well was drilled from January 17 to February 8, 2016, as part of the Corrective Action Investigation Plan (CAIP) for Corrective Action Unit 97: Yucca Flat/Climax Mine, Nevada Test Site, Nevada. The primary purpose of the well was to collect hydrogeologic data to evaluate uncertainty in the flow and transport conceptual model and its contamination boundary forecasts, and to detect radionuclides in groundwater from the CALABASH (U2av) underground test. Well ER-2-2 was not completed as planned due to borehole stability problems. As completed, the well includes a piezometer (p1) to 582 meters (m) (1,909 feet [ft]) below ground surface (bgs) installed in the Timber Mountain lower vitric-tuff aquifer (TMLVTA) and a 12.25-inch (in.) diameter open borehole to 836 m (2,743 ft) bgs in the Lower tuff confining unit (LTCU). A 13.375-in. diameter carbon-steel casing is installed from the surface to a depth of 607 m (1,990 ft) bgs. Data collected during borehole construction include composite drill cutting samples collected every 3.0 m (10 ft), geophysical logs to a depth of 672.4 m (2,206 ft) bgs, water-quality measurements (including tritium), water-level measurements, and slug test data. The well penetrated 384.05 m (1,260 ft) of Quaternary alluvium, 541.93 m (1,778 ft) of Tertiary Volcanics (Tv) rocks, and 127.71 m (419 ft) of Paleozoic carbonates. The stratigraphy and lithology were generally as expected. However, several of the stratigraphic units were significantly thicker then predicted—principally, the Tunnel formation (Tn), which had been predicted to be 30 m (100 ft) thick; the actual thickness of this unit was 268.22 m (880 ft). Fluid depths were measured in the borehole during drilling as follows: (1) in the piezometer (p1) at 552.15 m (1,811.53 ft) bgs and (2) in the main casing (m1) at 551.69 m (1,810.01 ft) bgs. As expected, field measurements for tritium were above the Safe Drinking Water Act limit (20,000 picocuries per liter) for a portion of the Tertiary volcanic section near the water table. Tritium concentrations were at or near the field detection limit in the Lower carbonate aquifer (LCA) while drilling. During drilling, a sample was collected while circulating in the LCA. The sample was submitted for off-site laboratory analysis. The sample results indicated low but measurable tritium concentrations. All Fluid Management Plan requirements were met during drilling activities.

54 ENVIRONMENTAL SCIENCES↗

Towards replacing physical testing of granular materials with a Topology-based Model

In the study of packed granular materials, the performance of a sample (e.g., the detonation of a high-energy explosive) often correlates to measurements of a fluid flowing through it. The “effective surface area,” the surface area accessible to the airflow, is typically measured using a permeametry apparatus that relates the flow conductance to the permeable surface area via the Carman-Kozeny equation. This equation allows calculating the flow rate of a fluid flowing through the granules packed in the sample for a given pressure drop. However, Carman-Kozeny makes inherent assumptions about tunnel shapes and flow paths that may not accurately hold in situations where the particles possess a wide distribution in shapes, sizes, and aspect ratios, as is true with many powdered systems of technological and commercial interest. To address this challenge, we replicate these measurements virtually on micro-CT images of the powdered material, introducing a new Pore Network Model based on the skeleton of the Morse-Smale complex. Pores are identified as basins of the complex, their incidence encodes adjacency, and the conductivity of the capillary between them is computed from the cross-section at their interface. We build and solve a resistive network to compute an approximate laminar fluid flow through the pore structure. Here, we provide two means of estimating flow-permeable surface area: (i) by direct computation of conductivity, and (ii) by identifying dead-ends in the flow coupled with isosurface extraction and the application of the Carman-Kozeny equation, with the aim of establishing consistency over a range of particle shapes, sizes, porosity levels, and void distribution patterns.

36 MATERIALS SCIENCE↗