Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLOW RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Heat Transfer Experiments of a 1st Stage Blade Cascade for Supercritical CO2 Oxy-Combustion Turbine Application

The results of internally cooled 1st stage blade (S1B) cascade testing in a supercritical CO2 environment is presented. The turbine blade design has been previously established for the end application of an oxy-combustion turbine operating in the Allam-Fetvedt cycle with turbine inlet conditions of 305 bar and 1150°C. The internally cooled blade features leading edge (LE) region impingement cooling, mid-section ribbed serpentine passages, and a pin-finned trailing edge (TE) region before cooling ejection holes. The geometry for the tested blade cascade has a cooled central blade with un-cooled blades on either side to match flowpath areas of the actual turbine. The flowpath reuses internal components previously employed for mid-section region ribbed serpentine passage experiments that established Nusselt number enhancement ratios over a range of Reynolds numbers from 100,000-400,000. New components include flow conditioning plates upstream and downstream of the blade cascade to adequately represent the flow field and blade external heat transfer coefficient profiles for the actual turbine. The cooled central blade utilizes uniform crystal temperature sensors (UCTS) with six sensors each on the blade pressure and suction surfaces distributed radially and from LE to TE. The post-processed UCTS quantified the maximum wall temperature seen at each installed sensor location. The test procedure consisted of establishing supercritical CO2 cooling flow temperature and flow rate and maintaining it throughout the test. The flow rate aims to match that for the actual in-service turbine blade design and is maintained through an orifice restriction to keep the pressure differential between internal cooling flow and external hot flow nearly constant. For the sCO2 flow path external to the blade, temperatures were ramped throughout the test via control of the test loop’s natural gas burner heater. The maximum temperature seen was 468°C and held constant for a duration of 10 minutes at which the blade metal temperature was predicted to be at its maximum before ramping down. For the turbine blade design for service inlet conditions, external flow path computational fluid dynamics (CFD) results and an internal cooling 1-D thermal and hydraulic flow network model using experimentally validated correlations served as thermal finite element (FE) boundary conditions to predict blade metal temperatures. These predicted temperatures were subsequently utilized in a structural FE model to predict blade life ratings dictated by Haynes 282 creep strength data, having a strong dependence on temperature. The boundary conditions experienced during testing are used in the same workflow and compared to the experimental results, with the goal of validating the analysis methodology and providing insight on the uncertainty in local metal temperature predictions.

20 FOSSIL-FUELED POWER PLANTS↗

Planar multifrequency mid-IR microwave-pumped lasers

The characteristics of planar repetitively pulsed diffusion-cooled HF, DF, HF – DF, Xe, and HF – DF – Xe(Kr) lasers pumped by a microwave discharge (2.45 GHz) are studied depending on the pump pulse duration (10 – 40 μs) and repletion rate (50 – 400 Hz), as well as on the composition and pressure of the working gas mixture (30 – 200 Torr) at low (to 0.6 L s{sup −1}) gas flow rates. It is demonstrated for the first time that a HF – DF – Xe gas-discharge laser may simultaneously operate as a HF – DF chemical molecular laser and a recombination laser based on xenon atom transitions and generate broadband (octave) radiation in the range 2.0 – 4.2 μm with an average output power of 43 mW and an efficiency of 0.9 %. With substitution of xenon for krypton, lasing in a HF – DF – Kr laser is obtained at wavelengths of 2.52 – 4.15 μm. Lasing in a HF – DF laser was achieved simultaneously in two spectral regions (2.7 – 2.9 and 3.6 – 4.2 μm) with an output power of ∼50 mW. It is found that a decrease in the pump pulse duration with a simultaneous increase in the pulse repletion rate for retaining the average energy deposition leads to an increase in the average output power and efficiency of the laser. At low pulse repetition rates (50 – 100 Hz) and a low gas mixture flow rate, helium buffer gas can be effectively substituted for neon. Operation of the Xe laser was achieved in the spectral range 2.03 – 3.65 μm with an average output power of 580 Mw at a pump pulse duration of 20 μs, a pulse repetition rate to 10 kHz, and a maximum efficiency of 55 %. The obtained experimental results demonstrate the possibility of creating broadband HF – DF – Xe lasers emitting in the frequency range 2 – 4 μm with a desired ratio of intensities in different spectral ranges. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DBD plasma-assisted ethanol steam reforming for green H 2 production: Process optimization through response surface methodology (RSM)

Herein this work investigates ethanol steam reforming (ESR) to produce hydrogen (H 2 ) in a dielectric barrier discharge (DBD) plasma reactor. A five-level, three-factor experiment design was performed using a response surface methodology (RSM) to evaluate the combined effects of the three process parameters, including discharge power, total flow rate, and ethanol-to-water (EtOH/H 2 O) molar ratio on the plasma-assisted ESR reaction. Quadratic regression models were employed in RSM to fit the experimental results and present the correlation between process parameters and targeted responses (EtOH conversion, H 2 yield, H 2 selectivity, and specific energy requirement (SER) for H 2 production). The results suggested that the EtOH/H 2 O molar ratio is considered to have the most significant effect on the EtOH conversion and H 2 , H 2 selectivity, while the total flow rate is the most significant parameter determining SER for H 2 production. Process optimization demonstrated the optimal process conditions, including a discharge power of 55.9 W, a total flow rate of 26.7 ml/min, and an EtOH/H 2 O molar ratio equal to 0.34. A validation test was performed and confirmed the feasibility of the optimization process.

08 HYDROGEN↗

Geomechanical and Hydrogeological Evaluation of a Shallow Hydraulic Fracture at the Devine Fracture Pilot Site, Medina County, Texas

UT-Austin’s Devine Fracture Pilot Site, 50 miles southwest of San Antonio, Texas, has been targeted for a comprehensive, multidisciplinary development of fracture diagnostic techniques that are cross-validated by ground-truth data acquisition near a recently created, 175-ft-deep, horizontal hydraulic fracture (Ahmadian et al. 2018 Demonstration of proof of concept of electromagnetic geophysical methods for high resolution illumination of induced fracture networks. In Proceedings of the SPE Hydraulic Fracturing Technology Conference and Exhibition, The Woodlands, Texas, USA, 23–25 January 2018. SPE-189858-MS.). To evaluate the fracture diagnostic methods at this site, we conducted injection tests with a predefined volumetric flow-rate profile, resembling a diagnostic fracture injection test on September 2020. Subsequently, we developed hydrogeological and geomechanical models based on flow-rate and bottomhole-pressure measurements. History-matching efforts using a simplified layer-cake hydrogeological model resulted in the field-scale formation permeability of 9.87 × 10 –15 m 2 (10 mD) and Darcy-scale fracture permeability. The analysis of the bottomhole pressure and injection-rate history showed that (1) the newly created horizontal fracture was closed adjacent to the injection well pre-injection and (2) the initial pump-pressure increase at a nominal volumetric injection rate led to near-well fracture reopening, fluid conductivity increase, and abrupt injection-rate increase. To overcome hydrogeological-model limitations of predicting fracture reopening throughout injection, we extended the modeling to a finite-element, poroelastic analysis of horizontal-fracture growth using a cohesive-zone model. Using this fracture-reopening model, we improved the history match of the transient-pressure response during the experiment by adjusting the hydromechanical properties. Furthermore, post-injection pressure transient analyses helped reduce uncertainty in the overburden-stress gradient, and the initial hydraulic-fracturing simulation verified the plausibility of achieving the surveyed propped fracture area.

02 PETROLEUM↗

Evaluation of a Wave Powered Water Pump Performance by Ocean Field Testing and WEC-Sim Modeling

This submission from AMEC (the Atlantic Marine Energy Center) includes data from an ocean field deployment of a wave powered water pump in March 2023. The wave pump is an upweller device, designed to enhance macroalgal aquaculture. The wave pump device was deployed off the coast of Isles of Shoals Appledore Island in Maine, USA. The data were collected using a custom-built DAQ module comprised of Arduino Unos. GPS time stamp accompanies the data. The data are volumetric flow rate from the wave pump, and relative motion of the device between float and spar buoys. Flow rate is measured by flow meter, and relative motion is measured by lidar. Calibration data for the lidar and flow meter sensors are included. This data set also includes synchronous Sofar Spotter buoy data from a mooring approximately 300 feet away from the wave pump mooring. Video data from the deployment are included from both on-board the device sporadically throughout the deployment, and from a webcam for a short duration of the deployment. Hydrophone data were also taken co-currently, and are available by contacting Martin Wosnik at the University of New Hampshire. The Matlab code used to process the field data is incorporated. A biological assessment is included which aided the NEPA consultation process, prior to conducting the field deployment. A WEC-Sim numerical model of the wave pump, and a re-design effort are part of this work. Code used to validate the WEC-Sim model from the field data are also included.

16 TIDAL AND WAVE POWER↗

KIPT ADS Target Cooling Analyses by MCNP/Fluent

This report presents multi-physics analyses of the target cooling system of the accelerator driven system (ADS) of the Kharkiv Institute of Physics and Technology (KIPT) using MCNP and Fluent computer programs. MCNP has been used to transport electrons, gammas, and neutrons, and to calculate the energy deposition in the target using a mesh-tally. The mesh-tally data have been imported in Fluent by a C subroutine that has been compiled and linked to Fluent as a user defined function. The KIPT ADS is in operation and Fluent used the CAD model from the manufacturing process of the target. The Fluent results for the reference case match very well the literature results obtained by STAR-CCM+ during the design phase. Other cases that differ from the reference one have been analyzed; in these cases, it is assumed a malfunction of the electron accelerator control or the primary water coolant pump. The target cooling system operates normally for all the analyzed cases except when the inlet water mass flow rate is decreased. If the water coolant mass flow decreases to 25%, the water maximum temperature exceeds the boiling point. However, the transient analysis showed that the target cooling system can operate for 180 seconds when the inlet water mass flow rate is decreased down by 50%.

42 ENGINEERING↗

Acquisitive root exploration strategies help maintain higher peak sap flux rates during summer drought, but more root biomass does not

Roots are responsible for soil water uptake, yet little is known about how variation in fine-root traits relates to whole-tree water movement, particularly during periods of drought. By combining a 3-yr dataset monitoring sap flow rates with measures of fine-root biomass, length, and morphology across 10 tree species, we addressed hypotheses concerning the role of fine-root system size and morphology in determining tree responses to summer drought as well as potential changes in their relative importance under more severe droughts. Greater fine-root biomass and length did not enable trees to maintain high rates of sap flow during drought, whereas the morphological traits, specific root length and specific root area, were linked to sustained sap flow rates during drought. We found that all species, irrespective of root traits, progressively reduced their sap flow under more extreme drought conditions, although more acquisitive root morphology was still associated with smaller reductions. Our results run counter to long-standing assumptions that larger root systems are better able to access soil water and maintain photosynthetic activity during drought. Instead, we find evidence that root morphology at least partially determines the capacity for water uptake and movement as soil moisture declines.

drought↗

Blind Modeling Validation Exercises Using the Horizontal Dry Cask Simulator

The U.S. Department of Energy (DOE) established a need to understand the thermal-hydraulic properties of dry storage systems for commercial spent nuclear fuel (SNF) in response to a shift towards the storage of high-burnup (HBU) fuel (> 45 gigawatt days per metric ton of uranium, or GWd/MTU). This shift raises concerns regarding cladding integrity, which faces increased risk at the higher temperatures within spent fuel assemblies present within HBU fuel compared to low-burnup fuel (≤ 45 GWd/MTU). A dry cask simulator (DCS) was built at Sandia National Laboratories (SNL) in Albuquerque, New Mexico to produce validation-quality data that can be used to test the accuracy of the modeling used to predict cladding temperatures. These temperatures are critical to evaluating cladding integrity throughout the storage cycle of commercial spent nuclear fuel. A model validation exercise was previously carried out for the DCS in a vertical configuration. Lessons learned during the previous validation exercise have been applied to a new, blind study using a horizontal dry cask simulator (HDCS). Three modeling institutions – the Nuclear Regulatory Commission (NRC), Pacific Northwest National Laboratory (PNNL), and Empresa Nacional del Uranio, S.A., S.M.E. (ENUSA) – were granted access to the input parameters from the DCS Handbook, SAND2017-13058R, and results from a limited data set from the horizontal BWR dry cask simulator tests reported in the HDCS update report, SAND2019-11688R. With this information, each institution was tasked to calculate peak cladding temperatures and air mass flow rates for ten HDCS test cases. Axial as well as vertical and horizontal transverse temperature profiles were also calculated. These calculations were done using modeling codes (ANSYS/Fluent, STAR-CCM+, or COBRA-SFS), each with their own unique combination of modeling assumptions and boundary conditions. For this validation study, the ten test cases of the horizontal dry cask simulator were defined by three independent variables – fuel assembly decay heat (0.5 kW, 1 kW, 2.5 W, and 5 kW), internal backfill pressure (100 kPa and 800 kPa), and backfill gas (helium and air). The plots provided in Chapter 3 of this report show the axial, vertical, and horizontal temperature profiles obtained from the dry cask simulator experiments in the horizontal configuration and the corresponding models used to describe the thermal-hydraulic behavior of this system. The tables provided in Chapter 3 illustrate the closeness of fit of the model data to the experiment data through root mean square (RMS) calculations of the error in peak cladding temperatures (PCTs), PCT axial locations, axial temperature profiles, vertical and horizontal temperature profiles at two different axial locations, and air mass flow rates for the ten test cases, normalized by the experimental results. The model results are assigned arbitrary model numbers to retain anonymity. Due to the relatively flat axial temperature profiles, small temperature gradients resulted in large deviations of all models’ PCT axial location from the experimental PCT axial location. When the PCT axial location error is excluded in the calculation of the combined RMS of the normalized errors that considers PCT, the temperature profiles, and the air mass flow rates, the model data fits the experimental data to within 5%. When the vault information is excluded, the model data fits the experimental data to within 2.5%. An error analysis was developed further for one model, using the model and experimental uncertainties in each validation parameter to calculate validation uncertainties. The uncertainties for each parameter were used to define quantifiable validation criteria. For this analysis, the model was considered validated for a given comparison metric if the normalized error in that metric divided by the validation uncertainty was less than or equal to 1. When considering the combined RMS of the normalized errors of all metrics divided by their validation uncertainties, the model was found to have satisfied the criterion for model validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modelling uranium dioxide corrosion under repository conditions: A pore-scale study of the chemical and thermal processes

This paper investigates the corrosion behaviors of spent uranium dioxide (UO 2 ) fuel when placed in geological repositories. We performed pore-scale reactive transport simulations of the UO 2 corrosion process in a defective fuel rod with different orientations of breach or fracture on its clad. It is found that the corrosion rate has strong dependency on the breach orientation. The highest corrosion rate of UO 2 is calculated when the angle between the groundwater flow direction and the clad fracture reaches 180°. UO 2 corrosion simulations with different flow rates are compared. The results show the higher flow rate accelerates the corrosion of UO 2 fuel. The effect of pH on the corrosion process is also determined. It is indicated that higher pH can limit the corrosion of UO 2 by reducing the reaction rate. The dependence of reaction rate and time on reactive surface area is explored. Spent fuel with lower surface area demonstrates longer lifetime under corrosion conditions. A numerical model coupling thermal conduction and chemical reactions is developed to assess the impact of temperature on the process of UO 2 corrosion. The results show that higher temperature leads to larger corrosion rates for UO 2 . Here, the predicted reaction rates are higher in comparison with the isothermal results. Hence, our results can help improve the fundamental understanding of UO 2 corrosion in geological repositories for long-term storage of spent nuclear fuels and provide guidance for the safe operations and selection of appropriate repositories.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Physics-Constrained Deep Learning Model for Simulating Multiphase Flow in 3D Heterogeneous Porous Media

Physics-based simulators for multiphase flow in porous media emulate nonlinear processes with coupled physics, and usually require extensive computational resources for software development, maintenance and simulation execution. As a result, a huge demand exists for fast modeling of coupled processes in a wide range of subsurface applications including geological sequestration, hydrocarbon recovery and geothermal energy extraction. In this work, an efficient physics-constrained deep learning model is developed for solving multiphase flow in 3-Dimensional (3D) heterogeneous porous media. The model fully leverages the spatial topology predictive capability of convolutional neural networks, specifically U-Net with successive contracting and expansive steps, and is coupled with an efficient continuity-based smoother to predict flow responses that need spatial continuity. Furthermore, the transient regions are penalized to steer the training process such that the model can accurately capture flow in these regions. The model takes inputs including properties of porous media, fluid properties and well controls, and predicts the temporal-spatial evolution of the state variables (pressure and saturation). While maintaining the continuity of fluid flow, the 3D spatial domain is decomposed into 2D images for reducing training cost, and the decomposition results in an increased number of training data samples and better training efficiency. Additionally, a surrogate model is separately constructed as a postprocessor to calculate well flow rate based on the predictions of state variables from the deep learning model. We use the example of CO 2 injection into saline aquifers, and apply the physics-constrained deep learning model that is trained from physics-based simulation data and emulates the physics process. The model performs prediction with a speedup of ~ 1400 times compared to physics-based simulations, and the average temporal errors of predicted pressure and saturation plumes are 0.27% and 0.099% respectively. Furthermore, water production rate is efficiently predicted by a surrogate model for well flow rate, with a mean error less than 5%. Therefore, with its unique scheme to cope with the fidelity in fluid flow in porous media, the physics-constrained deep learning model can become an efficient predictive model for computationally demanding inverse problems or other coupled processes.

58 GEOSCIENCES↗

Full Length Assembly Testing in PELICAN (Final Report)

In support of the development of the U.S. Department of Energy (DOE) Versatile Test Reactor (VTR), a thermal hydraulics test facility was constructed to generate experimental measurement of the pressure drop across a single full-scale assembly containing prototypic axial reflectors, fuel, and plena components. Constructed and operated at Argonne National Laboratory, the Pressure drop Experimental Loop for Investigations of Core Assemblies in Nuclear reactors (PELICAN) facility was designed to achieve hydraulic conditions identical to those anticipated for a full-scale fuel assembly located in the VTR core in the region with the highest flow rate. Using water as surrogate for liquid sodium, the flow loop was operated at elevated temperatures and pressures to match the thermophysical properties of liquid sodium and ensure matching Reynolds and Euler numbers. The measurement objectives for data generated from this test facility was driven primarily by the validation needs for code calculations and simulations of the reference VTR core. These objectives focused on the need to validate pressure drop results across the various segments of the fuel assembly as they relate directly to the pumping power and safety of the reactor. Presented in this report are experimental results and analytical comparisons based on testing of a full-length assembly in PELICAN. Housed within a hexagonal test section extending 3.4 m in length, the tested assembly features a prototypic lower reflector, grid plates, wire-wrapped rod bundle, upper reflector, and exit region. The rod bundle extends over 1.5 m in length and contains 217 individual wire-wrapped rods with dimensions that best reflect the reference VTR design. The as-tested bundle assembly was fabricated using 316 stainless steel 0.25-inch (6.35-mm) diameter rods wrapped with 0.04-inch (1.016-mm) diameter wire at a helical pitch of 10.51 inch (26.6 cm). Details of the method for in-house wire-wrapping, assembly, and installation are provided later in this report. Experimental measurements of pressure drop at 19 positions along the test assembly were recorded for a range of flow conditions, with special attention paid to key locations within the assembly, including component inlet and outlet, transition, and wire-wrapped rod bundle regions. Testing conditions were based on 110°C water with flow rates ranging from 50 to 450 GPM (3 to 27 kg/s) at the inlet of the test assembly generating Reynolds numbers and velocities up to ~8.0×10 4 and ~7.8 m/s, respectively, within the rod bundle region. Non-dimensional values for the friction factor were then calculated based on these experimental measurements and compared against those predicted by various analytical correlations available from open literature. Predictions by the upgraded Cheng and Todreas, Rehme, and Novendstern correlations fell within 4% to those values measured experimentally.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Interfacing Atmospheric Flow Tube to Ion Mobility Spectrometry: FY 2021 Final Report

An atmospheric flow tube (AFT) provides extended ion-molecule reaction times of 2-3 seconds compared to milliseconds in typical mass spectrometers. This results in several orders of magnitude enhanced sensitivity allowing for vapor detection at the parts-per-quadrillion levels when an AFT is coupled to a mass spectrometer (MS). The goal of this project was to demonstrate the feasibility of integrating an AFT ionization source to a more portable ion mobility spectrometer (IMS). This project was successful in integrating AFT to IMS, as shown in Figure ES.1. The PNNL team demonstrated measurable ion signal from an AFT-IMS with a Faraday plate detector. Reasonable ion signals were detectable at low flow rates approaching 1 m/s. This is close to the flow rates used with the AFT-MS, which has demonstrated parts-per-quadrillion vapor detection. Vapor detection enables non-contact detection of a variety of illicit substances for various applications including cargo screening, mail sorting facilities, and checkpoints. With further improvements to enhance detection, AFT-IMS has the potential to allow ultra-trace vapor detection in a more portable device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical simulation of flow and mixing in fracture intersections

Fluid transport through fractured geological formations is strongly influenced by the redistribution of solutes at fracture intersections. In this study, we perform detailed numerical simulations of flow and scalar transport within the intersection of two smooth, planar fractures. The analysis focuses on the mixing ratio, the proportion of solute flux exiting along the outlet branch aligned with the primary inlet flow direction, relative to the total solute flux at the outlets. We systematically investigate how the mixing ratio varies with four key parameters: Peclet number, Reynolds number, flow rate ratio between outlet branches, and fracture intersection angle. Results show that the mixing ratio decreases with increasing Peclet number and outlet flow rate ratio, consistent with reduced diffusive spreading and enhanced streamline routing. While low Reynolds numbers have minimal impact, inertial effects at higher Reynolds numbers significantly increase the mixing ratio. Additionally, acute and obtuse intersection angles alter flow partitioning and modify the solute distribution at the outlets. These findings provide a quantitative basis for incorporating physically realistic mixing behavior—intermediate between complete mixing and streamline-following assumptions—into network-scale transport models. The results have direct relevance to subsurface energy systems, including geothermal energy production, carbon sequestration, and contaminant remediation.

58 GEOSCIENCES↗

Flow through negatively charged, nanoporous membranes separates Li + and K + due to induced electromigration

Flow through negatively charged nanopores separates Li + and K + with selectivities of up to 70 and Li + passages from 20% to above 100%. Remarkably, both the Li + /K + selectivity and Li + passage initially increase with flow rate, breaking the permeability/selectivity trade-off. Modelling demonstrates that flow through the membranes creates electric fields that retard transport of cations. Selectivity increases with flow rate because the K + electromigration velocity exceeds its convective velocity, but for Li + electromigration is weaker than convection. Here, modelling also shows the importance of controlling concentration polarization. With further work, related separations might provide highly pure Li salts for battery manufacturing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flow and pressure estimators in a waste heat recovery system

An apparatus includes a pump circuit structured to receive pump data indicative of an operating characteristic of a pump feeding a fluid to a waste heat recovery (WHR) system; a flow circuit structured to receive valve position data indicative of a position of a valve downstream of the pump, estimate a flow rate of the fluid exiting the pump, and estimate the flow rate of the fluid exiting the valve; and a pressure circuit structured to receive pressure data indicative of the pressure of the fluid exiting the valve, estimate a change in pressure of the fluid across the WHR system, and determine a pressure of the fluid in a hot section of the WHR system based on the pressure of the fluid exiting the valve and the change in the pressure of the fluid across the WHR system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Novel High Energy Density Sorption-based Thermal Battery for Low-grade Thermal Energy Storage

Thermal energy storage (TES) can alleviate peak demand on the electricity grid by offsetting building thermal loads, increasing the grid’s reliability and resilience. However, low energy density and poor energy performance of existing TES technologies limit their applications. Sorption-based thermal battery (STB) system is thus developed using three-phase sorption technology to harvest low-temperature heat, store it with a much higher energy density than common TES systems and dehumidify air or provide space cooling in buildings. Although STB has been experimentally proved to be feasible, influencing factors on its performance are still unknown by far. Therefore, this paper conducted a parametric analysis on crystallization and crystal dissolution performance of a developed STB test rig. The crystallization results showed that the energy density of the STB increased with reducing the solution flow rate and the cooling water temperature. The dissolution results showed that a higher discharge rate of the STB can be achieved with increasing the flow rate and temperature of inlet diluted solution. The work in this study is helpful to the optimal design and operation of the STB system.

Wang, Lingshi↗

Ion-Exchange Modeling of Crystalline Silicotitanate for Cesium Removal - 20283

The Tank Closure Cesium Removal (TCCR) system is a Savannah River Site (SRS) demonstration 'at-tank' process designed to remove {sup 137}Cs from the high-level aqueous tank waste so that the decontaminated solution can be disposed as low-level waste. Cesium is removed by ion exchange (IX) columns using engineered IONSIV{sup TM} R9120-B form of the Crystalline Silicotitanate (CST) media. The TCCR system is deployed at Tanks 10 and Tank 11 in the SRS H Tank Farm. Water is added to the salt-cake in Tank 10 H to dissolve it. The dissolved salt solution waste is pumped out of Tank 10H (feed tank), through filters and IX columns. The decontaminated salt solution is transferred to Tank 11 (receipt tank), and on to Tank 50H for final disposal in the Saltstone Production Facility. The current TCCR can accommodate lead-lag (two-column) or lead-lag-guard (three-column) configurations to optimize media utilization and achieve the target decontamination. To assist the TCCR operations, a parametric study was conducted to evaluate the impact of different parameters (e.g., column configurations (single column, two columns or three columns in series), waste characteristics, operating temperature, process flow rate, CST average particle size) on the IX column performance including CST bed utilization. The initial results indicate that the IX column performance is improved at slower process flow rate, at lower operating temperature, and with smaller CST average particle size. Multi-column configurations are recommended, because the single-column configuration does not utilize CST bed effectively. This paper demonstrates the versatility of the ion exchange modeling to evaluate the effects of CST characteristics and operational parameters on IX column performances. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗