At least 145 records · Page 8

The curled wake model: a three-dimensional and extremely fast steady-state wake solver for wind plant flows

Abstract. Wind turbine wake models typically require approximations, such as wake superposition and deflection models, to accurately describe wake physics. However, capturing the phenomena of interest, such as the curled wake and interaction of multiple wakes, in wind power plant flows comes with an increased computational cost. To address this, we propose a new hybrid method that uses analytical solutions with an approximate form of the Reynolds-averaged Navier–Stokes equations to solve the time-averaged flow over a wind plant. We compare results from the solver to supervisory control and data acquisition data from the Lillgrund wind plant obtaining wake model predictions which are generally within 1 standard deviation of the mean power data. We perform simulations of flow over the Columbia River Gorge to demonstrate the capabilities of the model in complex terrain. We also apply the solver to a case with wake steering, which agreed well with large-eddy simulations. This new solver reduces the time – and therefore the related cost – it takes to simulate a steady-state wind plant flow (on the order of seconds using one core). Because the model is computationally efficient, it can also be used for different applications including wake steering for wind power plants and layout optimization.

17 WIND ENERGY↗

Addressing deep array effects and impacts to wake steering with the cumulative-curl wake model

Abstract. Wind farm design and analysis heavily rely on computationally efficient engineering models that are evaluated many times to find an optimal solution. A recent article compared the state-of-the-art Gauss-curl hybrid (GCH) model to historical data of three offshore wind farms. Two points of model discrepancy were identified therein: poor wake predictions for turbines experiencing a lot of wakes and wake interactions between two turbines over long distances. The present article addresses those two concerns and presents the cumulative-curl (CC) model. Comparison of the CC model to high-fidelity simulation data and historical data of three offshore wind farms confirms the improved accuracy of the CC model over the GCH model in situations with large wake losses and wake recovery over large inter-turbine distances. Additionally, the CC model performs comparably to the GCH model for single- and fewer-turbine wake interactions, which were already accurately modeled. Lastly, the CC model has been implemented in a vectorized form, greatly reducing the computation time for many wind conditions. The CC model now enables reliable simulation studies for both small and large offshore wind farms at a low computational cost, thereby making it an ideal candidate for wake-steering optimization and layout optimization.

17 WIND ENERGY↗

Astronomical image sensors.

Signal-generating astronomical sensors, describing Stratoscope Ii balloon-borne telescope

ASTRONOMICAL TELESCOPE↗

Terrestrial contamination in Apollo lunar samples.

The contamination prevention procedures adopted for controlling the collection, processing, and analysis of the Apollo lunar samples in order to keep them free of significant levels of terrestrial organic matter are described. The organic contaminants actually found in the samples by the various investigators are summarized. It is shown that the program succeeded in providing investigators with samples containing less than 0.1 ppm total contamination.

Flory, D. A.↗

Analysis of organogenic compounds in Apollo 11, 12, and 14 lunar samples.

DCl was used to distinguish hydrocarbons produced by acid treatment from hydrocarbons originally present in the samples when volatiles released by acid and thermal treatments from Apollo 11, 12, and 14 lunar samples were studied by quadrupole mass spectrometry and gas chromatography mass spectrometry. Multiple ion plotting permitted separation of deuterated from nondeuterated hydrocarbons in the DCl products. Stepwise thermal treatment was used to distinguish the source of the volatile compounds. The presence of LM rocket exhaust products was traced in two samples, and the presence of high-temperature stable nitrides in some samples is indicated.

Flory, D. A.↗

Organic analysis of lunar samples and the Martian surface.

In addition to the organogenic elements (H, C, N, O, S, P) which are necessary for the synthesis of organic molecules, the lunar samples from Apollo 11, 12, 14, and 15 contain substantial amounts of CO, N2, and CO2 which are released at relatively high temperatures and smaller amounts of more complex organic compounds (e.g., benzene). The lunar surface provides one of the less favorable solar system models for the synthesis of organic compounds; yet small amounts of these compounds have been detected in the returned samples. It is reasonable to assume that the different physical and developmental features of the planet Mars (increased gravitational field, presence of an atmosphere with CO2, CO, and H2O, recent volcanic and tectonic activity, etc.) would favor an increased organic content of the surface of this planet relative to the moon. Therefore the organic molecules present in the Martian soil should be measurable by miniaturized mass spectrometers after fractional distillation or gas chromatographic separation of the volatiles released by moderate heating.

Oro, J.↗

Environmental control of lunar samples in the Lunar Receiving Laboratory

The contamination controls used in the Lunar Receiving Laboratory during the processing of lunar samples are described. Initially, the lunar sample containers were opened and the material was examined in a vacuum complex with approximated lunar surface conditions. The process of examining and distributing the samples from this vacuum complex was time consuming. During both Apollo 11 and 12 missions portions of the lunar samples were processed for allocation in a small sterile glove box in a dry nitrogena atmosphere. After Apollo 12 a new system was installed based upon the experience gained from the small glove box. The system uses dry nitrogen as an environmental blanket and has the capability of being sterilized and of maintaining this sterility.

Reynolds, M. A.↗

Organic contamination monitoring and control in the Lunar Receiving Laboratory

An assessment of the nature and amount of organic matter present in returned lunar material has been one of the major scientific goals of the Apollo programs. The small amounts of organic matter expected to be indigenous to the lunar material can be easily detected by the analytical instrumentation used in organic geochemistry. The integrity of the lunar samples could, therefore, only be maintained by carefully controlling the collection, processing, and analyses of the lunar material. The procedures for contamination control are discussed along with the experimental approaches.

Simoneit, B. R.↗