Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLASH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Code-to-code comparison and validation of the radiation-hydrodynamics capabilities of the FLASH code using a laboratory astrophysical jet

The potential for laser-produced plasmas to yield fundamental insights into high energy density physics (HEDP) and deliver other useful applications can sometimes be frustrated by uncertainties in modeling the properties and behavior of these plasmas using radiation-hydrodynamics codes. In an effort to overcome this and to corroborate the accuracy of the HEDP capabilities in the publicly available FLASH radiation-hydrodynamics code, we present detailed code-to-code comparisons between FLASH and the HYDRA code developed at Lawrence Livermore National Laboratory using previously published HYDRA simulations from Grava et al. [Phys. Rev. E 78, 016403 (2008)]. That study describes a laser experiment that produced a jet-like feature that the authors compare to astrophysical jets. Importantly, the Grava et al. [Phys. Rev. E 78, 016403 (2008)] experiment included detailed x-ray interferometric measurements of electron number densities and a time-integrated measurement of the soft x-ray spectrum. Despite markedly different methods for treating the computational mesh, and different equations of state and opacity models, the FLASH results resemble the results from HYDRA and, most importantly, the experimental measurements of electron density. Having validated the FLASH code in this way, we use the code to further investigate and understand the formation of the jet seen in the Grava et al. [Phys. Rev. E 78, 016403 (2008)] experiment and discuss its relation to the Wan et al. [Phys. Rev. E 55, 6293 (1997)] experiment at the NOVA laser.

Orban, Chris (ORCID:0000000312004538)↗

Feasibility and performance of the staged Z-pinch: A one-dimensional study with FLASH and MACH2

Z-pinch platforms constitute a promising pathway to fusion energy research. Here, we present a one-dimensional numerical study of the staged Z-pinch (SZP) concept using the FLASH and MACH2 codes. We discuss the verification of the codes using two analytical benchmarks that include Z-pinch-relevant physics, building confidence on the codes' ability to model such experiments. Then, FLASH is used to simulate two different SZP configurations: a xenon gas-puff liner (SZP1*) and a silver solid liner (SZP2). The SZP2 results are compared against previously published MACH2 results, and a new code-to-code comparison on SZP1* is presented. Using an ideal equation of state and analytical transport coefficients, FLASH yields a fuel convergence ratio (CR) of approximately 39 and a mass-averaged fuel ion temperature slightly below 1 keV for the SZP2 scheme, significantly lower than the full-physics MACH2 prediction. For the new SZP1* configuration, full-physics FLASH simulations furnish large and inherently unstable CRs (>300) but achieve fuel ion temperatures of many kilo-electron volts. While MACH2 also predicts high temperatures, the fuel stagnates at a smaller CR. The integrated code-to-code comparison reveals how magnetic insulation, heat conduction, and radiation transport affect platform performance and the feasibility of the SZP concept.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Code-to-code comparison between FLASH and HYDRA in gas-puff Z-pinch modeling

The numerical modeling of gas-puff Z pinches involves the nonlinear coupling of a broad range of complex, multi-physics phenomena that makes such simulations challenging. The challenge is further compounded by nonlinear instabilities that can impact the dynamics of imploding gas-puff Z pinches, such as the magneto Rayleigh–Taylor instability (MRTI). If the growth rate and amplitude of the latter is comparable to the relevant timescales and properties of the imploding plasma, the MRTI can dramatically alter implosion dynamics, dictate pinch stability, and govern the plasma properties achievable in pulsed-power-driven laboratory experiments. National Laboratories and academic teams have developed numerical tools that can accurately model Z-pinch configurations and provide reliable design capabilities that can guide experimental choices and assist in interpreting experimental results. Most such tools, however, are not broadly available. Here, we present newly developed Z-pinch simulation capabilities of the publicly available FLASH code, applied in the study of MRTI growth and dynamical effects in gas-puff implosions. To verify the new implementations, we perform a comparison of FLASH gas-puff implosion simulations with previously published calculations with the HYDRA code from Lawrence Livermore National Laboratory, which have been validated with experimental data from the CESZAR pulsed-power driver at the University of California, San Diego. The experiments involved double- and triple-nozzle configurations, in an experimental attempt to stabilize the pinch to the MRTI. The code-to-code comparison shows similar results between the FLASH and HYDRA simulations, supporting the use of FLASH in the modeling of future gas-puff Z-pinch experiments at CESZAR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Capacitive discharge in flash experiments: A discussion of the charged species

Abstract We report on the discharge of the capacitance formed at the electrodes in flash experiments with yttria stabilized zirconia. The experiments were carried out by disconnecting the current, and, instead, short circuiting the electrodes through a resistor. The time dependent voltage across the resistor was measured; the ratio yielded the discharge current. The current decayed exponentially with time, as expected in an RC circuit, which allowed the measurement of the capacitance. Experiments were carried out in two ways. In one case the specimens were flashed within a glove box filled with Ar (< 1 ppm O 2 ): these yielded electronic conductors. In the other case the specimens were flashed in ambient air: while electronically conducting in‐flash these specimens recover their prior insulating behavior as soon as the current is turned off. The stored charge was two orders of magnitude greater in the Ar experiments. Rather unexpectedly, the sign of the voltage expressed at the electrodes was opposite in experiments carried out in air and in Ar. The capacitance measured in the discharge experiments is attributed to the formation of space charge adjacent to the electrodes. In the case of Ar experiments, the capacitance is very large, approaching 1 F; in this case the space charge is expected to be constituted from ions. In the air experiments the specimen becomes insulating, trapping the electrons as a space charge. Hall effect measurements of the carrier density and X‐ray photoelectron spectroscopy characterization of electronically conducting single crystal specimen of cubic zirconia are reported.

Materials Science↗

Image Alignment and Flat-Field Correction of Film and Computed Radiography Images on the LLNL Flash Testbed

Computed radiography (CR) imaging plates and film are used in HEAF firing tanks and in the NDE group. The imaging plates allow for the creation of high-resolution digital images with flash X-ray (FXR). A typical treatment of flash X-ray radiographs is flat-field correction, where the image from an experiment is normalized by a “flat-field” or “bright-field” image. This flat-field image is taken in an identical configuration to the experimental image, but without the object or experiment in the field of view (FOV). This treatment reduces spatial effects from the FXR spot size and detector misalignment, as each pixel value in the corrected image represents a ratio of collected radiation with the object in FOV to the collected radiation without the object in FOV. One challenge in the creation of a corrected image is the misalignment of the CR plate or film pack between capturing the flat-field image and the experimental image. Fiducial structures can remedy this issue. Small (3.18mm) stainless steel ball bearings serve as good fiducial structures due to their small size and high radiographic contrast. Spheres are view-agnostic geometry, always presenting a circular cross section no matter the orientation. This process was developed for images from the flash X-ray testbed. The flash testbed was used to compare the X-ray transmission at different thicknesses of aluminum and copper step wedges. Each step wedge section is a rectangular shape, so evaluation is made much simpler if the rectangles are not rotated with respect to the image. This alignment process aligns the object and flat-field images together and leaves the rectangles of each step aligned with the image.

36 MATERIALS SCIENCE↗

The Spectacular Ultraviolet Flash from the Peculiar Type Ia Supernova 2019yvq

Early observations of Type Ia supernovae (SNe Ia) provide essential clues for understanding the progenitor system that gave rise to the terminal thermonuclear explosion. Here, we present exquisite observations of SN 2019yvq, the second observed SN Ia, after iPTF 14atg, to display an early flash of emission in the ultraviolet (UV) and optical. Our analysis finds that SN 2019yvq was unusual, even when ignoring the initial flash, in that it was moderately underluminous for a SN Ia ($M_g \approx -18.5$ mag at peak) yet featured very high absorption velocities ($v \approx 15,0000$ km s -1 for Si II λ6355 at peak). We find that many of the observational features of SN 2019yvq, aside from the flash, can be explained if the explosive yield of radioactive 56 Ni is relatively low (we measure $M_{^{56}\mathrm{Ni}} = 0.31 \pm 0.05\,M_\odot$) and it and other iron-group elements are concentrated in the innermost layers of the ejecta. To explain both the UV/optical flash and peak properties of SN 2019yvq we consider four different models: interaction between the SN ejecta and a nondegenerate companion, extended clumps of 56 Ni in the outer ejecta, a double-detonation explosion, and the violent merger of two white dwarfs. Each of these models has shortcomings when compared to the observations; it is clear additional tuning is required to better match SN 2019yvq. In closing, we predict that the nebular spectra of SN 2019yvq will feature either H or He emission, if the ejecta collided with a companion, strong [Ca II] emission, if it was a double detonation, or narrow [O I] emission, if it was due to a violent merger.

79 ASTRONOMY AND ASTROPHYSICS↗

Do Flashing and Sealant Materials Need to be Exposed to Extreme Cycling?

In the U.S., over 50% of homes were built before 1980, when minimal building codes existed. The aging of building envelopes can significantly contribute to the air leakage, moisture intrusion, and durability of buildings leading to higher energy demands. Although the durability of building materials and envelope systems has been studied extensively, the durability of specific components like window-wall flashing and sealants remains underexplored. Current standards such as ASTM, NIST, and AAMA primarily focus on durability testing considering the high temperatures only and require sealant testing on anodized aluminum panels, leaving questions about performance in cold or fluctuating temperatures unanswered. Current ASTM and AAMA standards provide guidelines for durability testing but predominantly focus on exposure to higher temperature conditions. It remains unclear how exposure to cold temperatures, or cycles of both hot and cold conditions, affect the durability of these materials. Furthermore, AAMA standards mandate that flashing materials be tested on anodized aluminum panels, which may not reflect real-world applications. Therefore, this initial study aims to explore this concern through testing by constructing two window-wall interface prototypes and applying five different flashing and sealant materials to their joints. These samples were subjected to extreme temperatures, ranging from −34 ℃ (−30 °F) to 50 ℃ (122 °F), over a 28-day period (fourteen cycles of 24 hours), with daily visual inspections to document any signs of deterioration such as wrinkling, distortion, or warping. The study has two main objectives: (1) to determine whether flashing and sealant materials lose their durability and strength when exposed to varying climate conditions, specifically cold climates, and (2) to assess whether the interaction of these materials with different substrates (e.g., lumber, PVC, insulation) affects their durability and strength under varying climate conditions. The findings demonstrate how aging impacts the durability of window-wall systems interfaces, justifying future research that potentially could lead to the development of new testing protocols if significant defects are identified.

Palani, Hevar [ORNL] (ORCID:0000000220211994)↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

Frequency of light-flashes induced by Cerenkov radiation from heavy cosmic-ray nuclei

The expected frequency was calculated for light flashes induced in the dark-adapted eye by Cerenkov radiation from the flux of heavy nuclei that exists in space beyond the geomagnetic field. The expected frequency of light flashes depends on the threshold number of photons that must be absorbed in a rod cluster. The results of the calculation are presented as a curve of the mean frequency of light flashes versus the threshold number of absorbed photons. The results are not sensitive to variations in the path length from 5 to 15 grams per square centimeter of water-equivalent before the nucleus reaches the retina. Calculations were based on the fluxes and energy spectra of galactic cosmic ray nuclei of helium to iron, measured at a time of minimum solar modulation. The expected light flash frequencies induced by Cerenkov radiation are consistent with the frequencies reported by the astronauts on Apollo missions 11 through 14.

Madey, R.↗

Conspicuity of target lights: The influence of flash rate and brightness

The stimulus characteristics of lights that might aid a pilot to see and avoid, by alerting him to a potential threat were studied. The relative conspicuity of foveally equated, point-source, steady and flashing lights of several brightnesses, seen against a star background was examined. From the subject's viewpoint, these target lights could appear anywhere within a large (40 deg horizontal by 35 deg vertical) field of view. The lights appeared at random time intervals while the subject was periodically distracted by a simulated cockpit task. The results indicate that correct target detection increases and reaction time decreases with increased target intensity. Steady lights are missed more frequently and acquired more slowly than flashing lights, but no significant differences are found among the wide range of flash rates employed. The intensity of the light has a greater effect on both detection and reaction time to steady lights than to flashing lights. These results are compared with results of other researchers who used targets which appeared at fixed locations. The longest reaction times were recorded to lights which appeared either at the extremes or at the very center of the visual field.

Connors, M. M.↗

Light flashes observed by astronauts on Skylab 4

Two dedicated light flash observing sessions were conducted by one of the crewmen during the Skylab 4 mission. Analyses of his observations reveal a strong correlation between flash frequency and primary cosmic-ray flux, and an even stronger correlation between flash frequency and the South Atlantic Anomaly (SAA) region of the inner belt trapped radiation. Calculations indicate that an all-proton inner belt probably cannot produce the observed SAA flash rate, and they suggest that there may exist a previously unobserved inner belt flux of multiply charged nuclei.

Pinsky, L. S.↗

Apollo light flash investigations

The visual phenomenon of light flashes resulting from high energy, heavy cosmic rays penetrating the command module structure and crewmembers' eyes is investigated. Light flash events observed during dedicated sessions on Apollo 15, 16, 17 are described along with a Monte Carlo simulation of the exposure of an astronaut to cosmic radiation during a mission. Results of the Apollo Light Flash Moving Emulsion Detector experiment developed for Apollo 16 and 17 to obtain a direct record of incident cosmic ray particles are correlated with crewmembers' reports of light flashes.

W. Zachary Osborne↗

Quantitative observation of light flash sensations experiment MA-106

Light flashes caused by the interaction of cosmic particles with the visual apparatus have been observed by astronauts on all space missions since Apollo 11. This Apollo Soyuz Test Project experiment compared measurements of the observer's visual sensitivity with measurements of the ambient radiation environment and with the frequency and character of the flashes observed. The data obtained reveal a latitude dependence of the frequency of observed flashes. This distribution of flashes is correlated with the distribution of cosmic particles with stopping power greater than 15 keV/ micrometers in the eye. The interaction of dark adaptation, specific ionization, and range of particles in the retina as factors in the visualization of particle passage is discussed.

Budinger, T. F.↗

The structure of lightning flashes HF-UHF: 12 September 1975, Atlanta, Georgia

Simultaneous measurement of sferics at 3, 30, 139, and 295 MHz were made during thunderstorms. Wideband electronics and an analogue tape recorder continuously recorded the radiation from lightning with about 300 kHz of bandwidth. The data were obtained during the passage of a cold front. Flashing rate, burst rate and the structure of individual flashes were recorded. The record of a typical flash begins with a sudden burst of closely spaced pulses whose temporal structure is typical of the stepped leader, and ends in a large pulse suggestive of a first return stroke. The remainder of the flash consists of a sequence of pulses of varying amplitude separated by quiet periods of the order of milliseconds. The shape of these pulses and the temporal structure suggest that the first few large pulses are return strokes. Other discharges begin with widely spaced discrete pulses and resemble the preceding discharge less the leader and return stroke phase. The radiation exhibits a similar structure, at each of the frequencies monitored.

Levine, D. M.↗

Visual light flash observations on Skylab 4

Evaluation of light flashes observed in earth orbit establishes: (1) a strong correlation of very high flash rates with passage through the South Atlantic anomaly; (2) evidence for a predicted latitude effect; and (3) an increased flash rate outside the anomaly during a second observation period. Event rates and flash descriptions during South Atlantic anomaly passes indicate that there may be particles heavier than protons in the inner belt of trapped radiation.

Hoffman, R. A.↗

Char yield and flash-fire propensity of pyrolysis gases from materials

Comparison of the char yield after occurrence of a flash fire in the pyrolysis gases from various materials indicates that increased char yield appears to be associated with reduced flash-fire propensity for certain types of materials. For certain other materials, flash-fire propensity appears to be independent of char yield. The mechanisms of thermal decomposition and char formation may be more important factors in flash-fire propensity than the quantitative degree of char formation.

Hilado, C. J.↗

Thermonuclear-flash models for X-ray burst sources

Theoretical models for X-ray burst sources that invoke thermonuclear flashes in the surface layers of an accreting neutron star are discussed. Emphasis is placed on the studies by Joss (1978) and Joss and Li (1979) on the evolution of the helium-burning shell. Numerical calculations with regard to the mass accretion rate, core temperature of the neutron star and the sensitivity of the flash properties to the assumed mass and radius of the neutron star are considered. Attention is also given to the behavior of the surface luminosity following a thermonuclear flash, the decline from maximum X-ray luminosity, structure of the surface layers prior to and during the first helium-burning flash and the temporal evolution of the first X-ray burst.

Joss, P. C.↗

Flash heating is required to minimize sodium losses from chondrules

Chondrules were formed by high-temperature melting events, but do not always show Na depletion compared to CI chondrites, though extensive Na loss has been found in previous isothermal experiments. While Na loss can be prevented by high partial pressure of Na in the nebula, many people favor a flash-heating mechanism to reduce the Na loss from chondrule melts. To examine the validity of the flash-heating hypothesis, we have conducted a series of flash-heating experiments and observed Na loss rate under different conditions. Our results support the flash heating as a plausible heating mechanism to form chondrules.

Yu, Y.↗