Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy storage system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Development and Analysis of Control Strategies for a 1 MW/3.2 MWh Energy Storage System at Avista Utilities

This report documents the work performed by Pacific Northwest National Laboratory (PNNL) and Washington State University (WSU) supporting an effort to develop control strategies for a 1 MW/3.2 MWh energy storage system (ESS) at Avista Utilities (Avista). The ESS project is funded though the Washington Clean Energy Fund (CEF) program administered by the Washington State Department of Commerce (DOC). A tri-party Cooperative Research and Development Agreement (CRADA), namely the CRADA 360, was created in 2015 to facilitate this work.

25 ENERGY STORAGE↗

Economic Analysis of a Novel Thermal Energy Storage System Using Solid Particles for Grid Electricity Storage: Preprint

As renewable power generation becomes the mainstream new-built energy source, energy storage will become an indispensable need to complement the uncertainty of renewable resources to firm the power supply. When phasing out fossil-fuel power plants to meet the carbon neutral utility target in the midcentury around the world, large capacity of energy storage will be needed to provide reliable grid power. The integration of renewable power and storage to support future carbon-free utility has several significant and positive impacts including expanding the renewable generation into the grid, improving the peak-load response, and balancing the electricity supply and demand. Long-duration energy storage (10–100 hours duration) can potentially complement the reduction of fossil-fuel baseload generation that otherwise would risk grid security when a large portion of grid power comes from variable renewable sources. Current energy storage methods based on pumped storage hydropower or batteries have many limitations. Thermal energy storage (TES) has unique advantages in scale and siting flexibility to provide grid-scale storage capacity. A particle-based TES system has promising cost and performance for the future growing energy storage needs. This paper introduces the system and components required for the particle TES to be technically and economically competitive. A technoeconomic analysis based on preliminary component designs and performance shows that the particle TES integrated with an efficient air-Brayton combined cycle power system can provide power for several days by low-cost, high-performance storage cycles. It addresses grid storage needs by enabling large-scale grid integration of intermittent renewables like wind and solar, thereby increasing their grid value. The design specifications and cost estimations of major components in a commercial scale system are presented in this paper. The cost model provides insights for further development and cost comparison with competing technologies.

27 ARPA - Advanced Research Projects Agency-Energy↗

Photovoltaic Plant and Battery Energy Storage System Integration at NREL's Flatirons Campus

Although utility-scale solar photovoltaic (PV) power plants are becoming a cost-effective energy resource, there is belief within the energy industry that the increasing penetrations of PV technologies could potentially impact grid reliability. This is due to the variability across timescales, the forecast uncertainty of the solar energy resource, and the impacts on both distribution and transmission systems. This can cause utilities to severely limit PV installations or to assign PV integration costs when considering a least-cost portfolio of resources. As California and other regions in the United States are marching toward fulfilling - and probably exceeding - their renewables portfolio standards goals, grid operators are beginning to face operational challenges that could have implications for existing renewable and nonrenewable generators and that will shape opportunities for future projects. In this work, we focused on developing controls and conducting demonstrations for AC-coupled PV-battery energy storage systems (BESS) in which PV and BESS are collocated and share a point of common coupling (PCC).

14 SOLAR ENERGY↗

Conceptual Design Study of a Thermal Energy Storage System Using Granular Solids for Coal-fired Boilers

<span style="font-size: 12pt;">Presentation for the 2020 International Pittsburgh Coal Conference held virtually from September 8-11, 2020.</span><span style="font-size: 12pt;">Abstract: As electricity from various renewable energy sources is increasingly supplied to the power grid, the grid’s stability will be challenged. Proposed grid-stability solutions will need to address variability of sources, such as solar and wind energy, in order to alleviate problems such as overgeneration and ramping. In regions where increases in solar energy are prominent, such as California, the net power demand curve often referred to as “the Duck Curve,” has caused problems for energy dispatchers, due to over-generation and fast ramping demands. In this project, we investigated a conceptual design for a Thermal Energy Storage System (TESS) integrated into a coal-fired power plant to support grid-scale storage. Implementing a TESS into power plants can allow for an increase in renewable sources, increase grid resilience, and allow conventional coal-fired plants to operate more efficiently. For this project, a TESS using granular solids as the energy-storage media is integrated into a conventional coal-fired power plant. The purpose of the TESS is to store energy from the flue gas during low demand periods and transfer the energy to steam during peak demand periods. The storage allows the stabilization of combustion and related boiler components at low loads and provides the opportunity to avoid some shutdowns. This study uses thermodynamic properties of several candidate thermal storage materials to estimate the size of storage system required for several operating scenarios. </span>

Huckaby, E. David↗

Predictive-Maintenance Practices: For Operational Safety of Battery Energy Storage Systems

Changes in the Demand Profile and a growing role for renewable and distributed generation are leading to rapid evolution in the electric grid. These changes are beginning to considerably strain the transmission and distribution infrastructure. Utilities are increasingly recognizing that the integration of energy storage in the grid infrastructure will help manage intermittency and improve grid reliability. This recognition, coupled with the proliferation of state-level renewable portfolio standards and rapidly declining lithium-ion (Li-ion) battery costs, has led to a surge in the deployment of battery energy storage systems (BESSs). Additionally, although BESSs represented less than 1% of grid-scale energy storage in the United States in 2019, they are the preferred technology to meet growing demand because they are modular, scalable, and easy to deploy across diverse use cases and geographic locations.

25 ENERGY STORAGE↗

Hybrid Distributed Wind and Battery Energy Storage Systems

This document is a literature review of battery coupled distributed wind applications, including but not limited to fully DC-based power systems, the conceptual value of co-located wind and storage assets, and black start capabilities. This report will serves as a baseline reference document for MIRACL hybrids system research and to identify opportunities for future research in this space.

17 WIND ENERGY↗

On the role of Battery Energy Storage Systems in the day-ahead Contingency-Constrained Unit Commitment problem under renewable penetration

The integration of variable Renewable Energy Sources (vRES) to alleviate greenhouse gas emissions has introduced significant challenges for power systems operations. These challenges include high levels of uncertainty due to the intermittence associated with vRES and therefore impose the need to devise a reliable and cost-effective day-ahead unit commitment and power and reserves scheduling for real-time operations. Also, this increasing penetration of vRES requires higher ramping capabilities from units originally designed for other purposes (e.g., base-load generation), which might be exacerbated during contingency states. Hence, in this work, we propose a methodology to address the day-ahead Contingency-Constrained Unit Commitment (CCUC) problem that leverages the participation of Battery Energy Storage Systems (BESSs) to address load-following and post-contingency management, therefore alleviating the ramping burden on conventional thermal generators. To do so, we formulate a three-level optimization problem that represents the decision-making process of obtaining the least-cost commitment, generation and reserves scheduling, while restricting the Conditional Value-at-Risk (CVaR) of the system imbalance at real-time operations to user-defined tolerance levels. In addition, we devise a computationally efficient solution approach for the proposed problem based on the Column-and Constraint Generation (CCG) algorithmic framework. Two numerical experiments are conducted to empirically illustrate the benefits of the proposed methodology. Key results indicate a reduction in real-time ramping needs and a better usage of the system resources, with a reduction in the overall system commitment levels and reserve scheduling costs when compared to a benchmark case in which storage is not available.

Moreira, Alexandre↗

Use of Systems Engineering in Repurposing Coal-Fired Power Plants with Malta Pumped Thermal Energy Storage System

he electric sector across North America is facing a transition. Both economics and policy decisions have pointed towards a broad retirement of fossil assets across markets. Owners are facing the problem of how to evolve the base of the electric sector from fossil asset to greener alternative. Coal-fired power plants built the modern electricity grid. Their rotating machinery are the beating heart of the grid, providing essential resiliency and reliability services. Power plant retirements are disruptive to plant workforces and cause outsized impacts on surrounding communities. The transition from thermal power plants that use rotating machinery to generate electricity (e.g., coal- and gas-fired plants) to variable, inverter-based generation (e.g., solar and wind) is affecting the reliability of the electric grid. Grid operators and national regulators have issued warnings about known and anticipated risk. In 2021, Malta Inc. was awarded a Department of Energy (DOE) grant to study how to integrate a Malta 100MW Pumped Heat Energy Storage (PHES) system with a retiring coal-fired power plant to meet emissions requirements, retain plant workforces, preserve communities, and maintain grid reliability. This presentation provides a summary of this study, focusing on how systems engineering approach was used to arrive at a proposed design concept that met multiple objectives and requirements. There will be three main parts for this presentation. The first part of the presentation will focus on how different systems engineering was applied for this work. In particular, the following areas: stakeholder engagement, site selection process, developing requirements and use cases for the integrated system, defining the system and its boundary, coming up with different system architecture/option, performing a techno-economic analysis to compare the different options and down selection of the preferred option, will be discusses. For these areas, discussion on the decisions on how much breadth and depth to go into each area will be provided. These discussions provide good insights into how to apply systems engineering. The second part of the presentation will provide a deeper dive into the two recommended integration options that repurpose coal-fired power plants with Malta PHES system. The comparison of the two options and general guidance of how to choose an option will be provided. This is particularly useful for utilities who are facing coal-plant retirements. The two options will be compared based on its performance (such as power output, efficiency), complexity, and cost. The social impact on local communities of the two options will also be discussed. The final part of the presentation will discuss the impact that this work has had, including Malta Inc. being invited to the White House to discuss progress and outcomes of this work with the Interagency Working Group on Coal and Power Plant Communities and Economic Revitalization. In summary, this presentation aims to provide a showcase of how sy

25 ENERGY STORAGE↗

Analysis of degradation in residential battery energy storage systems for rate-based use-cases

This article examines the impact of residential battery energy storage (BES) systems' operational modes on the life (i.e. usable energy capacity) of the battery under several climatic conditions and battery chemistries. The sharp increase in residential BES installations has been a result of decreasing costs of batteries, increase in rate structures motivated applications such as solar self-consumption and time-of-use energy management, and customers purchasing these systems for backup power. While these different modes of operations provide a combination of increased bill savings, reliability of supply, and energy sustainability to the customer, their operational characteristics vary significantly between use-cases. Functional life of BES systems is known to be strongly dependent on their operating conditions. In this article, we analyze the operation of residential BES systems under different rate-based use-cases, for different battery chemistries and cell designs, and under different environmental conditions. This is conducted by simulating the control of BES operations using rate-based cycling algorithms and analyzing the prognosis of multiple battery lifetime models that consider complex nonlinear dependencies of operational stress factors such as state-of-charge, depth-of-discharge, and temperature on degradation. Significant variations in battery life are observed owing to the differences in characteristics of the uses-cases coupled with environmental conditions and battery chemistries. Such differences lead to the conclusion that choice of residential BES technologies and chemistries should account for their intended use-cases.

25 ENERGY STORAGE↗

Enhanced Inertial Support: Modeling Fast Frequency Response Controls for Energy Storage System Inverters

Reduction of power system inertia is a growing concern for grid operators given the transition under way from conventional fossil generators to inverter-based resources. One key concern is the rapid and severe dip in power system frequency following a large disturbance which could trigger remedial actions including operation of under frequency load shedding (UFLS) relays. A potential solution is to utilize battery energy storage systems (BESS) to provide fast frequency response(FFR) to mitigate the system frequency impact of low system inertia. In this work, we investigate different control parameters to achieve modeled FFR response from BESS in the simulated US Western Interconnection. First, a very low inertia model is developed from an existing positive sequence model of the Western Interconnection. Afterwards, we tune the BESS dynamic response parameters to eliminate any risks of reaching UFLS relay thresholds following the loss of large generators. Finally, we investigate the relative impact of having large BESS units in comparison of multiple smaller units in the same area. The results of the analyses indicate that 1 GW of transmission-connected BESS can help mitigate the frequency drop caused by large generators outages in the Western Interconnection, and significantly reduce the risk of under frequency load shedding.

power system dynamic performance, Low Inertia, Fas↗

Investigation of two concrete thermal energy storage system configurations for continuous power production

Two Modelica concrete thermal energy storage (CTES) models are built to analyze potential CTES system designs. One design is the single pipe network design wherein a heat transfer fluid (HTF) flows in one direction during heat deposition and the opposite direction during heat removal. All pipes in the network are used for either deposition (charging) or removal (discharging). The second design is a dual pipe network design in which a network of HTF pipes carries charging fluid and a separate piping network carries discharging HTF. Operation of these two configurations to produce constant steam is evaluated. Here, results indicate that the designs are likely appropriate for different applications with the single pipe network appearing appropriate for batch energy applications and the dual pipe network for continuous energy applications.

25 ENERGY STORAGE↗

Integrated Heat Exchanger-Phase Change Material Thermal Energy Storage System

The purpose of this study is to experimentally investigate the thermal performance of an innovative thermal energy storage (TES) system that combines the advantages of the phase-change material (PCM)/graphite foam latent heat TES medium developed at Argonne National Laboratory (Argonne) and the internally supported plate-fin (ISPE) cell architecture heat transfer fluid (HTF) flow channels developed at Brayton Energy (Brayton). Several essential tasks were accomplished: (1) Thermal property characterization. Thermal properties of the graphite foam were characterized, providing necessary data for experimental result analysis and numerical simulation. (2) Design and optimization of lab-scale test module. Based on Brayton’s full-scale heat exchanger (HX)-TES system, the experimental test module was designed, optimized, and fabricated. (3) Thermal performance testing and data analysis. Five cycle tests were successfully conducted—including one with approximately 3.5 psig of pressure applied to the diaphragms—to investigate the thermal performance of the experimental test module for charging and discharging. Temperature profiles were generated for each charging test and discharging test as a function of time. The temperature profiles clearly show three TES stages: sensible heat (temperature increase), latent heat (melting), and sensible heat (temperature increase) for the charging process. Similarly, the temperature profiles clearly show three thermal energy release stages: sensible heat (temperature decrease), latent heat (solidification), and sensible heat (temperature decrease). Melting and solidification of the PCM generally occurred in relatively narrow temperature ranges, indicated by the flattened temperature regions in the temperature profiles. These phase changes ranged approximately 3°C for melting and 3.5°C for solidification. The charging and discharging temperature profiles were similar for similar experimental parameter tests whether or not pressure was applied to the diaphragm to eliminate the gap between the HX surface and the TES subsystem. This indicates that the effect of a small gap between the HX surface and the TES subsystem is insignificant for charging and discharging. (4) Comparison of experimental data and simulation results. We compared the experimental data to the numerical simulation results. Numerical simulations were conducted by using the ANSYS FLUENT 2019 R3 commercial computational fluid dynamics software. The predicted phase-change times agreed reasonably well with those from the experimental data. In most cases, the estimated time differences between the relative phase changes were within 16%. The predicted start and end times for the charging process agreed well with those from the experimental data. However, the simulation results showed earlier start and end times than the experimental data for the discharging process. Overall, the experimental data and its comparison with the simulation predictions verified the technical viability of the integrated ISPF HX-PCM/graphite foam latent-heat TES system.

25 ENERGY STORAGE↗

Energy storage systems for electrical microgrids with pulsed power loads

Pulsed power loads (PPLs) are highly non-linear and can cause significant stability and power quality issues in an electrical microgrid. According to the present invention, many of these issues can be mitigated by an Energy Storage System (ESS) that offsets the PPL. The ESS can maintain a constant bus voltage and decouple the generation sources from the PPL. For example, the ESS specifications can be obtained with an ideal, band-limited hybrid battery and flywheel system.

Weaver, Wayne W.↗

SIW21-95: Hybridizing Synchronous Condensers with Grid-Forming Battery Energy Storage Systems

One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.

grid forming↗

Technical and economic feasibility of molten chloride salt thermal energy storage systems

A techno-economic study is performed to assess the feasibility of molten chloride salt thermal energy storage (TES) systems for next generation concentrating solar power. Refractory liners internally insulate tanks to allow tank shells to be constructed from carbon steel. The liner must not be wetted by salt to maintain predictable thermal properties and manageable heat loss out of the tank. The commercial scale tank liner is an anchored brick and mortar design with expansion joints to accommodate thermal expansion. Furthermore, finite element analysis is performed to optimize the thermal and mechanical profile of the tank. Equalizing the shell temperature between the water-cooled foundation and the shell wall is necessary to minimize differential thermomechanical stress and lower overall stress values below industrial allowable limits. The cost of the TES system is estimated to be $60/kWhth, which is four times greater than Department of Energy targets. Solutions to reduce system cost and overall risk are proposed.

14 SOLAR ENERGY↗

Mitigation of Motor Stalling and FIDVR via Energy Storage Systems with Temporal Logic Specifications

The fault-induced delayed voltage recovery (FIDVR) phenomenon has been very common from the distribution system through the transmission system. It causes a delay on recovering significantly depressed local voltage after the fault is cleared, and it can also lead to more widespread cascading system failures. Mitigating this event with current control approaches is challenging and becoming a crucial issue. Here, a model predictive control-based strategy employing signal temporal logic specifications is proposed to help mitigate FIDVR. To this end, it investigates and extends a dynamic performance model allowing analytic insights into the system-wide impact of motor stalling and FIDVR. The proposed controller provides richer descriptions of voltage specifications addressing both magnitude and time simultaneously. We consider different control specifications with reactive power support from energy storage systems to prevent the voltage during/after the fault from dropping too low, and reduce the delay time of voltage recovery. The simulation results conducted with the IEEE 57 bus test network validate the proposed method and demonstrate the effectiveness of the mitigation strategy on FIDVR.

25 ENERGY STORAGE↗

Optimization-Based Dynamic Voltage Support of Microgrids Using Energy Storage Systems

A microgrid network is characterized by a high R/X ratio, making the voltage more sensitive to active power changes compared to bulk power systems, where the voltage is regulated primarily by reactive power. Due to its sensitivity, voltage control approaches for microgrids should also consider the active power input coupling, making it very different from conventional power systems. Additionally, as the energy costs associated with active and reactive powers are different and the operational conditions of microgrids connected to active distribution systems vary over time, the ideal controller to provide voltage support must be flexible enough to handle these technical and operational constraints. This paper proposes a model predictive control approach to provide dynamic voltage support using energy storage systems. This approach uses a simplified predictive model of the system to solve the model predictive control problem. By proper selection of model predictive control weighting parameters, the quality of service provided can be adjusted to achieve the desired performance. A simulation study in MATLAB/Simulink validates the proposed approach for the Cordova, Alaska microgrid. Results show that the performance of the voltage support can be adjusted depending on the choice of weight and constraints of the controller.

24 POWER TRANSMISSION AND DISTRIBUTION↗