Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores in California. Predicted indoor air quality and energy consumption using a matrix of ventilation scenarios (Final Report)

Through mass-balance modeling of various ventilation scenarios that might satisfy the ASHRAE 62.1 Indoor Air Quality (IAQ) Procedure, we estimate indoor concentrations of contaminants of concern (COCs) in California “big box” stores, compare estimates to available thresholds, and for selected scenarios estimate differences in energy consumption. Findings are intended to inform decisions on adding performance-based approaches to ventilation rate (VR) standards for commercial buildings. Using multi-zone mass-balance models and available contaminant source rates, we estimated concentrations of 34 COCs for multiple ventilation scenarios: VRmin (0.04 cfm/ft 2 ), VRmax (0.24 cfm/ft 2 ), and VRmid (0.14 cfm/ft 2 ). We compared COC concentrations with available health, olfactory, and irritant thresholds. We estimated building energy consumption at different VRs using a previously developed EnergyPlus model. VRmax did control all contaminants adequately, but VRmin did not, and VRmid did so only marginally. Air cleaning and local ventilation near strong sources both showed promise. Higher VRs increased indoor concentrations of outdoor air pollutants. Lowering VRs in big box stores in California from VRmax to VRmid would reduce total energy use by an estimated 6.6% and energy costs by 2.5%. Reducing the required VRs in California’s big box stores could reduce energy use and costs, but poses challenges for health and comfort of occupants. Source removal, air cleaning, and local ventilation may be needed at reduced VRs, and even at current recommended VRs. Also, alternative ventilation strategies taking climate and season into account in ventilation schedules may provide greater energy cost savings than constant ventilation rates, while improving IAQ.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical challenges for energy conservation in N -body simulations of collapsing self-interacting dark matter halos

Dark matter (DM) halos can be subject to gravothermal collapse if the DM is not collisionless, but engaged in strong self-interactions instead. When the scattering is able to efficiently transfer heat from the centre to the outskirts, the central region of the halo collapses and reaches densities much higher than those for collisionless DM. This phenomenon is potentially observable in studies of strong lensing. Current theoretical efforts are motivated by observations of surprisingly dense substructures. However, a comparison with observations requires accurate predictions. One method to obtain such predictions is to use N-body simulations. Collapsed halos are extreme systems that pose severe challenges when applying state-of-the-art codes to model self-interacting dark matter (SIDM). In this work, we investigate the root of such problems, with a focus on energy non-conservation. Moreover, we discuss possible strategies to avoid them. We ran N-body simulations, both with and without SIDM, of an isolated DM-only halo and we adjusted the numerical parameters to check the accuracy of the simulation. We find that not only the numerical scheme for SIDM can lead to energy non-conservation, but also the modelling of gravitational interaction and the time integration are problematic. The main issues we find are: (a) particles changing their time step in a non-time-reversible manner; (b) the asymmetry in the tree-based gravitational force evaluation; and (c) SIDM velocity kicks breaking the time symmetry. Tuning the parameters of the simulation to achieve a high level of accuracy allows us to conserve energy not only at early stages of the evolution, but also later on. However, the cost of the simulations becomes prohibitively large as a result. Some of the problems that make the simulations of the gravothermal collapse phase inaccurate can be overcome by choosing appropriate numerical schemes. However, other issues still pose a challenge. Our findings motivate further works on addressing the challenges in simulating strong DM self-interactions.

dark matter↗

Recommendations on Implementing the Energy Conservation Building Code in Visakhapatnam, AP, India

Visakhapatnam can play an important role in improving energy efficiency in its buildings by implementing ECBC. This document seeks to capture stakeholder recommendations on a road map for implementation, which can help all market players plan for implementation. Visakhapatnam also has an opportunity to serve as a role model for other Smart Cities and cities in general in India. The road map and steps that VUDA adopts to implement ECBC can provide helpful examples to these other cities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On numerical energy conservation for an implicit particle-in-cell method coupled with a binary Monte-Carlo algorithm for Coulomb collisions

We report conventional particle-in-cell (PIC) methods suffer from enhanced numerical heating (explicit PIC) or cooling (semi-implicit PIC) when coupled with a binary Monte-Carlo algorithm for Coulomb collisions. In this work, a fully-implicit θ-PIC scheme (with adjustable time-biasing parameter 1/2 ≤ θ ≤) is considered. The discrete change in energy of a closed system after a time step for this scheme scales with (1/2 - θ)C θ , where C θ is a positive definite quantity that depends on the frequency spectrum of the energy in the fields. Collisions lead to additional energy in the field fluctuations associated with high-frequency light waves produced by a numerical Bremsstrahlung process, which can result in a large increase in the numerical cooling rate for θ > 1/2. However, for θ = 1/2, energy is exactly conserved. The energy in the field fluctuations on long time scales agrees with that calculated using the equipartition theorem for a classical system in thermodynamic equilibrium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Fabrication of Photonic Crystals for Thermal Energy Conservation

The vision of intelligent and large-area fabrics capable of signal processing, sensing and energy harvesting has made incorporating electronic devices into flexible fibers an active area of research. Fiber-integrated rectifying junctions in the form of photovoltaic cells and light-emitting diodes (LEDs) have been fabricated on optical fiber substrates. However, the length of these fiber devices has been limited by the processing methods and the lack of a sufficiently conductive and transparent electrode. Their cylindrical device geometry is ideal for single device architectures, like photovoltaics and LEDs, but not amenable to building multiple devices into a single fiber. In contrast, the composite preform-to-fiber approach pioneered in our group addresses the key challenges of device density and fiber length simultaneously. It allows one to construct structured fibers composed of metals, insulators and semiconductors and enables the incorporation of many devices into a single fiber capable of performing complex tasks such as of angle of incidence and color detection. However, until now, devices built by the preform-to-fiber approach have demonstrated only ohmic behavior due to the chalcogenide semiconductor's amorphous nature and defect density. From a processing standpoint, non-crystallinity is necessary to ensure that the preform viscosity during thermal drawing is large enough to extend the time-scale of breakup driven by surface tension effects in the fluids to times much longer than that of the actual drawing. The structured preform cross-section is maintained into the microscopic fiber only when this requirement is met. Unfortunately, the same disorder that is integral to the fabrication process is detrimental to the semiconductors' electronic properties, imparting large resistivities and effectively pinning the Fermi level near mid-gap. Indeed, the defect density within the mobility gap of many chalcogenides has been found to be 1018-1019 cm-3 eV-1, resulting in a narrow depletion width and ohmic behavior at metal-semiconductor junctions. In this work we incorporated phase-changing semiconductors, those that may be easily converted between the amorphous and crystalline states, into composite fibers with a goal towards constructing rectifying junctions in fiber.

14 SOLAR ENERGY↗

RenewableNY - An Industrial Energy Conservation Initiative

The New York Industrial Retention Network (NYIRN) manages the RenewableNY program to assist industrial companies in New York City to implement energy efficiency projects. RenewableNY provides companies with project management assistance and grants to identify opportunities for energy savings and implement energy efficiency projects. The program helps companies identify energy efficient projects, complete an energy audit, and connect with energy contractors who install renewable energy and energy efficient equipment. It also provides grants to help cover the costs of installation for new systems and equipment. RenewableNY demonstrates that a small grant program that also provides project management assistance can incentivize companies to implement energy efficiency projects that might otherwise be avoided. Estimated savings through RenewableNY include 324,500 kWh saved through efficiency installations, 158 kW of solar energy systems installed, and 945 thm of gas avoided.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Generalization and extension of the law of acoustic energy conservation in a nonuniform flow

An exact conservation equation is derived which generalizes the familiar acoustic energy equations. The new relation is valid for arbitrary disturbances to a viscous, compressible flow. It is suggested by a development of the acoustic energy equation by means of a regular perturbation expansion of the general energy equation of fluid mechanics. A perturbation energy density and flux are defined and identified as the exact physical quantities whose leading order perturbation representations are the usual acoustic energy density and flux. The conservation equation governing the perturbation energy quantities is shown to yield previously known results for several special cases.

Myers, M. K.↗

Identification of cost effective energy conservation measures

In addition to a successful program of readily implemented conservation actions for reducing building energy consumption at Kennedy Space Center, recent detailed analyses have identified further substantial savings for buildings representative of technical facilities designed when energy costs were low. The techniques employed for determination of these energy savings consisted of facility configuration analysis, power and lighting measurements, detailed computer simulations and simulation verifications. Use of these methods resulted in identification of projected energy savings as large as $330,000 a year (approximately two year break-even period) in a single building. Application of these techniques to other commercial buildings is discussed

Bierenbaum, H. S.↗

Electron Bifurcation Makes the Puzzle Pieces Fall Energetically into Place in Methanogenic Energy Conservation

Microbial life has evolved a wide range of metabolisms exploiting in many cases unanticipated suites of oxidation-reduction reactions to generate energy. Although many of these suites of reactions don't allow these microbes to enjoy the same quality of energetic life that we enjoy via respiration/oxidative phosphorylation, it has conferred the ability for life to exploit almost any oxidation-reduction reaction. We find in many of these cases when energy is sparing, the difference between life and death may be conserving the maximal amount of energy and minimizing loss of free energy through heat.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy conserving and potential-enstrophy dissipating schemes for the shallow water equations

To incorporate potential enstrophy dissipation into discrete shallow water equations with no or arbitrarily small energy dissipation, a family of finite-difference schemes have been derived with which potential enstrophy is guaranteed to decrease while energy is conserved (when the mass flux is nondivergent and time is continuous). Among this family of schemes, there is a member that minimizes the spurious impact of infinite potential vorticities associated with infinitesimal fluid depth. The scheme is, therefore, useful for problems in which the free surface may intersect with the lower boundary.

Arakawa, Akio↗

Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores and other commercial buildings in California. Issues related to the ASHRAE 62.1 Indoor Air Quality Procedure

This report considers the question of whether the California Energy Commission should incorporate the ASHRAE 62.1 ventilation standard into the Title 24 ventilation rate (VR) standards, thus allowing buildings to follow the Indoor Air Quality Procedure. This, in contrast to the current prescriptive standard, allows the option of using ventilation rate as one of several strategies, which might include source reduction and air cleaning, to meet specified targets of indoor air concentrations and occupant acceptability. The research findings reviewed in this report suggest that a revised approach to a ventilation standard for commercial buildings is necessary, because the current prescriptive ASHRAE 62.1 Ventilation Rate Procedure (VRP) apparently does not provide occupants with either sufficiently acceptable or sufficiently healthprotective air quality. One possible solution would be a dramatic increase in the minimum ventilation rates (VRs) prescribed by a VRP. This solution, however, is not feasible for at least three reasons: the current need to reduce energy use rather than increase it further, the problem of polluted outdoor air in many cities, and the apparent limited ability of increasing VRs to reduce all indoor airborne contaminants of concern (per Hodgson (2003)). Any feasible solution is thus likely to include methods of pollutant reduction other than increased outdoor air ventilation; e.g., source reduction or air cleaning. The alternative 62.1 Indoor Air Quality Procedure (IAQP) offers multiple possible benefits in this direction over the VRP, but seems too limited by insufficient specifications and inadequate available data to provide adequate protection for occupants. Ventilation system designers rarely choose to use it, finding it too arbitrary and requiring use of much non-engineering judgment and information that is not readily available. This report suggests strategies to revise the current ASHRAE IAQP to reduce its current limitations. These strategies, however, would make it more complex and more prescriptive, and would require substantial research. One practical intermediate strategy to save energy would be an alternate VRP, allowing VRs lower than currently prescribed, as long as indoor VOC concentrations were no higher than with VRs prescribed under the current VRP. This kind of hybrid, with source reduction and use of air cleaning optional but permitted, could eventually evolve, as data, materials, and air-cleaning technology allowed gradual lowering of allowable concentrations, into a fully developed IAQP. Ultimately, it seems that VR standards must evolve to resemble the IAQP, especially in California, where buildings must achieve zero net energy use within 20 years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AN ENERGY-CONSERVING, PARTICLE-DOMINATED, TIME-DEPENDENT MODEL OF 3C 58 AND ITS OBSERVABILITY AT HIGH ENERGIES

We present a time-dependent spectral model of the nebula 3C 58 and compare it with available data. The model is for a leptonic nebula in which particles are subject to synchrotron, inverse Compton, self-synchrotron Compton, adiabatic, and bremsstrahlung processes. We find that 3C 58 is compatible with being a particle-dominated nebula, with a magnetic field of 35 {mu}G. A broken power-law injection fits well the multi-frequency data, with a break energy at about 40 GeV. We find that 3C 58 is not expected to appear in VERITAS or MAGIC II, unless the local IR background is a factor of {approx}20 off Galactic models' averages. For cases in which the cosmic microwave background dominates the inverse Compton contribution, we find that 3C 58 will not be visible either for the Cherenkov Telescope Array.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of storage system designs and techniques for optimizing energy conservation in integrated utility systems. Volume 3: (Assessment of technical and cost characteristics of candidate IUS energy storage devices)

Six energy storage technologies (inertial, superconducting magnetic, electrochemical, chemical, compressed air, and thermal) were assessed and evaluated for specific applicability to the IUS. To provide a perspective for the individual storage technologies, a brief outline of the general nature of energy storage and its significance to the user is presented.

Source record↗

Energy savings modelling of re-tuning energy conservation measures in large office buildings

Today, many large commercial buildings use sophisticated building automation systems (BASs) to manage a wide range of building equipment. While the capabilities of BASs have increased over time, many buildings still do not fully use the BAS’s capabilities and are not properly commissioned, operated or maintained, which leads to inefficient operation, increased energy use, and reduced lifetimes of the equipment. This paper investigates the energy savings potential of several common HVAC system re-tuning measures on a typical large office building, using the Department of Energy’s building energy modeling software, EnergyPlus. The baseline prototype model uses roughly as much energy as an average large office building in existing building stock, but does not utilize any re-tuning measures. Individual re-tuning measures simulated against this baseline include automatic schedule adjustments, damper minimum flow adjustments, thermostat adjustments, as well as dynamic resets (set points that change continuously with building and/or outdoor conditions) to static pressure, supply-air temperature, condenser water temperature, chilled and hot water temperature, and chilled and hot water differential pressure set points. Six combinations of these individual measures have been formulated – each designed to conform to limitations to implementation of certain individual measures that might exist in typical buildings. All the individual measures and combinations were simulated in 16 climate locations representative of specific U.S. climate zones. The modeling results suggest that the most effective energy savings measures are those that affect the demand-side of the building (air-systems and schedules). Many of the demand-side individual measures were capable of reducing annual total HVAC system energy consumption by over 20% in most cities that were modeled. Supply side measures affecting HVAC plant conditions were only modestly successful (less than 5% annual HVAC energy savings for most cities for all measures). Combining many of the re-tuning measures revealed deep savings potential. Some of the more aggressive combinations revealed 35-75% reductions in annual HVAC energy consumption, depending on climate and building vintage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy conservation and the transportation sector

The present status of the energy implications of the transportation systems in the United States was illustrated, with primary emphasis on the technologies and methods for achieving a substantial reduction in the associated energy price (approximately 25% of the nation's energy is consumed directly in the operation of these systems). These technologies may be classified as follows: (1) improvement of system efficiency (system operations or technological), (2) substitution for scarce energy resources (electrification, alternate fuels, use of man power, recycling), (3) curtailment of end use (managed population growth rate, education of citizenry, alternatives to personal transportation, improved urban planning, reduced travel incentives). Examples and illustrations were given. Thirty-four actions were chosen on the basis of a preliminary filtering process with the objective of: (1) demonstrating a methodological approach to arrive at logical and consistent conservation action packages, (2) recommending a viable and supportable specific set of actions.