Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Usage Reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Metal–organic frameworks as O 2 -selective adsorbents for air separations

Oxygen is a critical gas in numerous industries and is produced globally on a gigatonne scale, primarily through energy-intensive cryogenic distillation of air. The realization of large-scale adsorption-based air separations could enable a significant reduction in associated worldwide energy consumption and would constitute an important component of broader efforts to combat climate change. Certain small-scale air separations are carried out using N 2 -selective adsorbents, although the low capacities, poor selectivities, and high regeneration energies associated with these materials limit the extent of their usage. In contrast, the realization of O 2 -selective adsorbents may facilitate more widespread adoption of adsorptive air separations, which could enable the decentralization of O 2 production and utilization and advance new uses for O 2 . Here, we present a detailed evaluation of the potential of metal–organic frameworks (MOFs) to serve as O 2 -selective adsorbents for air separations. Drawing insights from biological and molecular systems that selectively bind O 2 , we survey the field of O 2 -selective MOFs, highlighting progress and identifying promising areas for future exploration. As a guide for further research, the importance of moving beyond the traditional evaluation of O 2 adsorption enthalpy, ΔH, is emphasized, and the free energy of O 2 adsorption, ΔG, is discussed as the key metric for understanding and predicting MOF performance under practical conditions. Based on a proof-of-concept assessment of O 2 binding carried out for eight different MOFs using experimentally derived capacities and thermodynamic parameters, we identify two existing materials and one proposed framework with nearly optimal ΔG values for operation under user-defined conditions. While enhancements are still needed in other material properties, the insights from the assessments herein serve as a guide for future materials design and evaluation. Computational approaches based on density functional theory with periodic boundary conditions are also discussed as complementary to experimental efforts, and new predictions enable identification of additional promising MOF systems for investigation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reserve Li/SOC12 Battery Safety Testing

A reserve Lithium/Thionyl Chloride Battery concept is developed and undergoing feasibility testing in terms of performance, safety and abusive conditions. The feasibility of employing a battery of this type to replace thermal batteries in certain applications is demonstrated. Excellent performance of a Li/SOCl2 reserve battery is obtained across the temperature range from 0 C to +44 C. Performance improvement over the thermal battery usage is greater by a factor of 3 when discharge time and energy density are compared. Performance over an expanded temperature range is also possible. Safety and abusive testing is accomplished successfully on a series of five units. Further performance improvements can be achieved with regard to battery weight and volume reductions.

Dils, C. T.↗

China's Top-1000 Energy-Consuming Enterprises Program:Reducing Energy Consumption of the 1000 Largest Industrial Enterprises in China

In 2005, the Chinese government announced an ambitious goal of reducing energy consumption per unit of GDP by 20% between 2005 and 2010. One of the key initiatives for realizing this goal is the Top-1000 Energy-Consuming Enterprises program. The energy consumption of these 1000 enterprises accounted for 33% of national and 47% of industrial energy usage in 2004. Under the Top-1000 program, 2010 energy consumption targets were determined for each enterprise. The objective of this paper is to evaluate the program design and initial results, given limited information and data, in order to understand the possible implications of its success in terms of energy and carbon dioxide emissions reductions and to recommend future program modifications based on international experience with similar target-setting agreement programs. Even though the Top-1000 Program was designed and implemented rapidly, it appears that--depending upon the GDP growth rate--it could contribute to somewhere between approximately 10% and 25% of the savings required to support China's efforts to meet a 20% reduction in energy use per unit of GDP by 2010.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Addressing Energy Demand through Demand Response. International Experiences and Practices

Demand response (DR) is a load management tool which provides a cost-effective alternative to traditional supply-side solutions to address the growing demand during times of peak electrical load. According to the US Department of Energy (DOE), demand response reflects “changes in electric usage by end-use customers from their normal consumption patterns in response to changes in the price of electricity over time, or to incentive payments designed to induce lower electricity use at times of high wholesale market prices or when system reliability is jeopardized.” 1 The California Energy Commission (CEC) defines DR as “a reduction in customers’ electricity consumption over a given time interval relative to what would otherwise occur in response to a price signal, other financial incentives, or a reliability signal.” 2 This latter definition is perhaps most reflective of how DR is understood and implemented today in countries such as the US, Canada, and Australia where DR is primarily a dispatchable resource responding to signals from utilities, grid operators, and/or load aggregators (or DR providers).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hexavalent Chromium Reduction by Zero Valent Iron in the Presence and Absence of TCE and CCl{sub 4} - 18445

Among the hundreds of chromium and chlorinated organic contaminated sites in the United States are Hanford and Savannah River Sites, which are of special interest to the U.S. Department of Energy (DOE). At the Hanford Site, chromate was used throughout the site as a corrosion inhibitor in reactor cooling water, which led to its discharge to the surface through spills during usage, disposal to cribs, and pipeline leaks. Chromium migration to the water table would result in rapid migration to the Columbia River, a main source of drinking water and salmon spawning. Also, of interest to the DOE is a blend of Cr(VI), TCE and CCl{sub 4} co-contaminants present in the soil subsurface and ground water and possible remediation strategies to reduce their impact on the health of communities downstream. This research study focused on degradation of hexavalent chromium, Cr(VI) to Cr (III) by zero valent iron Fe(0) in the presence and absence of TCE and CCl{sub 4} in batch reactors. It was determined that degradation of Cr(VI) by Fe (0) in the presence and absence of TCE and CCl{sub 4} is a complex surface limiting reaction and order of the reaction varies between second order initially (0∼1 hr) and zeroth order in the long term (∼ over 6 hours). The observed pseudo-first order rate constant for TCE and Cr(VI) degradation are 0.8869 hr{sup -1} for TCE and 1.217 hr{sup -1} for Cr(VI), respectively. The relative magnitudes of rate constants indicate that in the presence of excess ZVI, both Cr(VI) and TCE compete for the available ZVI but the degradation of Cr(VI) is much faster than that of TCE. Preliminary experiments on the degradation of CCl{sub 4} suggest it is not as readily degradable by ZVI as TCE, due to its non-polar nature. A mixture of ZVI and Fe(II) was used to achieve a suitable degradation pattern for CCl{sub 4} in the presence of Cr(VI); 82% degradation of CCl{sub 4} was achieved and the rate constant was found to be 0.3113 hr{sup -1}. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demonstration and Evaluation of an Advanced Oxidation Technology for Cooling Tower Water Treatment

A cooling tower is a heat rejection device that uses an evaporative cooling process to reject heat to the atmosphere from water cooled chilled water plant. Cooling towers are commonly applied to water cooled chilled water plants in large commercial buildings. The Silver Bullet alternative water treatment (AWT) technology is a non-chemical-based cooling tower water treatment technology. It is advertised as a simpler water treatment technology that can reduce cooling tower blowdown by increasing the CoC, which reduces monthly chemical costs, monthly operation and maintenance costs, and the amount of scale that collects on condenser water tubes and cooling towers. The primary focus of this evaluation was measuring cooling tower make up water usage pre- and post- installation of the AWT. In addition, annual reductions in cooling tower chemical costs, monthly water chemistry reports, ease of installation, and overall cost effectiveness were evaluated.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SolOpt

This software requires inputs of simple hot water system inventory information and general building usage information to calculate the energy and cost benefits of solar PV and solar SHW systems. This tool conducts and complex hourly simulation of solar PV and SHW energy production to optimize rooftop area. Four optimization criteria are offered that will change the sizes of the two solar energy systems: !'Jet-present value, discounted payback period, C02 reduction, and total renewable energy production. This tool includes the option for advanced system design inputs if they are known. This tool calculates energy savings, demand reduction, cost savings, incentives and building life cycle costs including: simple payback, discounted payback, net-present value, and savings to investment ratio. In addition this tool also displays the environmental benefits of a project.

Dean, Jesse↗

Impact of Extended Daylight Saving Time on National Energy Consumption Report to Congress

The Energy Policy Act of 2005 (Pub. L. No. 109-58; EPAct 2005) amended the Uniform Time Act of 1966 (Pub. L. No. 89-387) to increase the portion of the year that is subject to Daylight Saving Time. (15 U.S.C. 260a note) EPAct 2005 extended the duration of Daylight Saving Time in the spring by changing its start date from the first Sunday in April to the second Sunday in March, and in the fall by changing its end date from the last Sunday in October to the first Sunday in November. (15 U.S.C. 260a note) EPAct 2005 also called for the Department of Energy to evaluate the impact of Extended Daylight Saving Time on energy consumption in the United States and to submit a report to Congress. (15 U.S.C. 260a note) This report presents the results of impacts of Extended Daylight Saving Time on the national energy consumption in the United States. The key findings are: (1) The total electricity savings of Extended Daylight Saving Time were about 1.3 Tera Watt-hour (TWh). This corresponds to 0.5 percent per each day of Extended Daylight Saving Time, or 0.03 percent of electricity consumption over the year. In reference, the total 2007 electricity consumption in the United States was 3,900 TWh. (2) In terms of national primary energy consumption, the electricity savings translate to a reduction of 17 Trillion Btu (TBtu) over the spring and fall Extended Daylight Saving Time periods, or roughly 0.02 percent of total U.S. energy consumption during 2007 of 101,000 TBtu. (3) During Extended Daylight Saving Time, electricity savings generally occurred over a three- to five-hour period in the evening with small increases in usage during the early-morning hours. On a daily percentage basis, electricity savings were slightly greater during the March (spring) extension of Extended Daylight Saving Time than the November (fall) extension. On a regional basis, some southern portions of the United States exhibited slightly smaller impacts of Extended Daylight Saving Time on energy savings compared to the northern regions, a result possibly due to a small, offsetting increase in household air conditioning usage. (4) Changes in national traffic volume and motor gasoline consumption for passenger vehicles in 2007 were determined to be statistically insignificant and therefore, could not be attributed to Extended Daylight Saving Time.

02 PETROLEUM↗

Size and Structure of the Sequence Space of Repeat Proteins

The coding space of protein sequences is shaped by evolutionary constraints set by requirements of function and stability. We show that the coding space of a given protein family— the total number of sequences in that family—can be estimated using models of maximum entropy trained on multiple sequence alignments of naturally occurring amino acid sequences. We analyzed and calculated the size of three abundant repeat proteins families, whose members are large proteins made of many repetitions of conserved portions of *30 amino acids. While amino acid conservation at each position of the alignment explains most of the reduction of diversity relative to completely random sequences, we found that correlations between amino acid usage at different positions significantly impact that diversity. We quantified the impact of different types of correlations, functional and evolutionary, on sequence diversity. Analysis of the detailed structure of the coding space of the families revealed a rugged landscape, with many local energy minima of varying sizes with a hierarchical structure, reminiscent of frustrated energy landscapes of spin glass in physics. This clustered structure indicates a multiplicity of subtypes within each family and suggests new strategies for protein design.

Jacopo Marchi↗

Wet Waste Hydrothermal Liquefaction and Biocrude Upgrading to Hydrocarbon Fuels: 2021 State of Technology

Each year the U.S. Department of Energy Bioenergy Technologies Office (BETO) assesses progress in their research and development efforts toward sustainable production of renewable fuels (DOE 2016) through the annual state of technology (SOT) assessment. The SOT assessment evaluates the impact of the year’s research progress on the modeled minimum fuel selling price (MFSP) for selected biofuel conversion pathways and measures the current state of the technology relative to defined goal case projections. Supply chain sustainability analysis to track and guide research toward improved greenhouse gas (GHG) emissions, energy usage, water usage and other environmental metrics for the pathway is performed by Argonne National Laboratory (Cai et al. 2018, 2020). Technical and cost targets for a projected goal case set for the year 2022 were previously established for the wet waste hydrothermal liquefaction (HTL) and biocrude upgrading pathway and summarized in a design report (Snowden-Swan et al. 2017). Process performance advancements made for HTL and biocrude hydrotreating have resulted yearly reductions in the modeled MFSP relative to the initial SOT (2018) (Snowden-Swan et al. 2020, 2021). This report summarizes the research and associated techno-economic analysis (TEA) for the pathway 2021 SOT. Methods and economic assumptions for the nth plant analysis used for the TEA are consistent with the design report (Snowden-Swan et al. 2017), with the exception of updates in the modeled cost year (2016) and income tax rate (21%).

09 BIOMASS FUELS↗

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Application of Active Controls (IAAC) technology to an advanced subsonic transport project: Final ACT configuration evaluation

The Final ACT Configuration Evaluation Task of the Integrated Application of Active Controls (IAAC) technology project within the energy efficient transport program is summarized. The Final ACT Configuration, through application of Active Controls Technology (ACT) in combination with increased wing span, exhibits significant performance improvements over the conventional baseline configuration. At the design range for these configurations, 3590 km, the block fuel used is 10% less for the Final ACT Configuration, with significant reductions in fuel usage at all operational ranges. Results of this improved fuel usage and additional system and airframe costs and the complexity required to achieve it were analyzed to determine its economic effects. For a 926 km mission, the incremental return on investment is nearly 25% at 1980 fuel prices. For longer range missions or increased fuel prices, the return is greater. The technical risks encountered in the Final ACT Configuration design and the research and development effort required to reduce these risks to levels acceptable for commercial airplane design are identified.

Source record↗

In-Use Fleet Evaluation of Fast-Charge Battery Electric Transit Buses

With support from the U.S. Department of Energy's Vehicle Technologies Office, the National Renewable Energy Laboratory (NREL) conducts real-world performance evaluations of advanced medium- and heavy-duty fleet vehicles. Evaluation results can help vehicle manufacturers fine-tune their designs and assist fleet managers in selecting fuel-efficient, low-emission vehicles that meet their economic and operational goals. In 2015, NREL launched an in-service evaluation of 12 battery electric buses (BEBs) compared to conventional compressed natural gas (CNG) buses operated by Foothill Transit in West Covina, California. The study aims to improve understanding of the overall usage and effectiveness of fast-charge BEBs and associated charging infrastructure in transit operation. To date, NREL researchers have analyzed more than 148,000 km of in-use operational data, including driving and charging events. Foothill Transit purchased the BEBs with grant funding from the Federal Transit Administration's Transit Investments for Greenhouse Gas and Energy Reduction Program.

33 ADVANCED PROPULSION SYSTEMS↗

Decentralised optimisation of cogeneration in virtual power plants

Within several projects we investigated grid structures and management strategies for active grids with high penetration of renewable energy resources and distributed generation (RES and DG). Those ''smart grids'' should be designed and managed by model based methods, which are elaborated within these projects. Cogeneration plants (CHP) can reduce the greenhouse gas emissions by locally producing heat and electricity. The integration of thermal storage devices is suitable to get more flexibility for the cogeneration operation. If several power plants are bound to centrally managed clusters, it is called ''virtual power plant''. To operate smart grids optimally, new optimisation and model reduction techniques are necessary to get rid with the complexity. There is a great potential for the optimised management of CHPs, which is not yet used. Due to the fact that electrical and thermal demands do not occur simultaneously, a thermally driven CHP cannot supply electrical peak loads when needed. With the usage of thermal storage systems it is possible to decouple electric and thermal production. We developed an optimisation method based on mixed integer linear programming (MILP) for the management of local heat supply systems with CHPs, heating boilers and thermal storages. The algorithm allows the production of thermal and electric energy with a maximal benefit. In addition to fuel and maintenance costs it is assumed that the produced electricity of the CHP is sold at dynamic prices. This developed optimisation algorithm was used for an existing local heat system with 5 CHP units of the same type. An analysis of the potential showed that about 10% increase in benefit is possible compared to a typical thermally driven CHP system under current German boundary conditions. The quality of the optimisation result depends on an accurate prognosis of the thermal load which is realised with an empiric formula fitted with measured data by a multiple regression method. The key functionality of a virtual power plant is to increase the value of the produced power by clustering different plants. The first step of the optimisation concerns the local operation of the individual power generator, the second step is to calculate the contribution to the virtual power plant. With small extensions the suggested MILP algorithm can be used for an overall EEX (European Energy Exchange) optimised management of clustered CHP systems in form of the virtual power plant. This algorithm has been used to control cogeneration plants within a distribution grid. (author)

20 FOSSIL-FUELED POWER PLANTS↗

Modeling the Impacts of Solar Distributed Generation on U.S. Water Resources

Distributed electric power generation technologies typically use little or no water per unit of electrical energy produced; in particular, renewable energy sources such as solar PV systems do not require cooling systems and present an opportunity to reduce water usage for power generation. Within the US, the fuel mix used for power generation varies regionally, and certain areas use more water for power generation than others. The need to reduce water usage for power generation is even more urgent in view of climate change uncertainties. In this paper, we present an example case within the state of Tennessee, one of the top four states in water consumption for power generation and one of the states with little or no potential for developing centralized renewable energy generations. The potential for developing PV generation within Knox County, Tennessee, is studied, along with the potential for reducing water withdrawal and consumption within the Tennessee Valley stream region. Electric power generation plants in the region are quantified for their electricity production and expected water withdrawal and consumption over one year, where electrical generation data is provided over one year and water usage is modeled based on the cooling system(s) in use. Potential solar PV electrical production is modeled based on LiDAR data and weather data for the same year. Our proposed methodology can be summarized as follows: First, the potential solar generation is compared against the local grid demand. Next, electrical generation reductions are specified that would result in a given reduction in water withdrawal and a given reduction in water consumption, and compared with the current water withdrawal and consumption rates for the existing fuel mix. The increase in solar PV development that would produce an equivalent amount of power, is determined. In this way, we consider how targeted local actions may affect the larger stream region through thoughtful energy development. This model can be applied to other regions, other types of distributed generation, and used as a framework for modeling alternative growth scenarios in power production capacity in addition to modeling adjustments to existing capacity.

distributed energy generation↗

Distributed Cross-Channel Hierarchical Aggregation for Foundation Models

Vision-based scientific foundation models hold significant promise for advancing scientific discovery and innovation. This potential stems from their ability to aggregate images from diverse sources—such as varying physical groundings or data acquisition systems—and to learn spatio-temporal correlations using transformer architectures. However, tokenizing and aggregating images can be compute-intensive, a challenge not fully addressed by current distributed methods. In this work, we introduce the Distributed Cross-Channel Hierarchical Aggregation (D-CHAG) approach designed for datasets with a large number of channels across image modalities. Our method is compatible with any model-parallel strategy and any type of vision transformer architecture, significantly improving computational efficiency. We evaluated D-CHAG on hyperspectral imaging and weather forecasting tasks. When integrated with tensor parallelism and model sharding, our approach achieved up to a 75% reduction in memory usage and more than doubled sustained throughput on up to 1,024 AMD GPUs on the Frontier Supercomputer.

Tsaris, Aristeidis (aris) [ORNL] (ORCID:0000000277↗

Conceptual Feasibility Study of the Hyperloop Vehicle for Next-Generation Transport

The Hyperloop concept is proposed as a faster, cheaper alternative to high-speed rail and traditional short-haul aircraft. It consists of a passenger pod traveling through a tube under light vacuum while being propelled and levitated by a combination of permanent and electro-magnets. The concept addresses NASA's research thrusts for growth in demand, sustainability, and technology convergence for high-speed transport. Hyperloop is a radical departure from other advanced aviation concepts, however it remains an aeronautics concept that tackles the same strategic goals of low-carbon propulsion and ultra-effcient vehicles. System feasibility was investigated by building a multidisciplinary vehicle sizing model that takes into account aerodynamic, thermodynamic, structures, electromagnetic, weight, and mission analyses. The sizing process emphasized the strong coupling between the two largest systems: the tube and the passenger pod. The model was then exercised to examine Hyperloop from a technical and cost perspective. The structural sizing analysis of the travel tube demonstrates potential for signi cant capital cost reductions by considering an underwater route. Examination of varying passenger capacity indicates that the system can be operated with a wide range of passenger loads without significant change in operating expenses. Lastly, a high-level sizing study simulated variations in tube area, pressure, pod speed, and passenger capacity showing that there is a tube pressure that minimizes operating energy usage. The value of this optimal tube pressure is highly sensitive to numerous design details. These combined estimates of energy consumption, passenger throughput, and mission analyses all support Hyperloop as a faster and cheaper alternative to short-haul flights. The tools and expertise used to quantify these results also demonstrate how traditional aerospace design methods can be leveraged to handle the complex and coupled design process. Much of the technology development required for the Hyperloop is shared with next-generation aircraft. Furthermore, the substantial public interest and active commercial development make it an ideal candidate as an aircraft technology driver and test bed.

Hyperloop Vehicle↗

Pathway to Decarbonization Through Industrial Energy Efficiency: Micro and Macro Perspectives from Compressed Air Usage

Abstract Energy audits directly provided the industrial sector with reduced energy costs and avoided emissions. Still, they also lead to far-reaching indirect and induced local, regional, and national benefits. This paper aims to present the techno-economic-environmental analysis to achieve decarbonization through implementing industrial energy efficiency at micro and macro levels. An integrated techno-economic-environmental methodology is developed. Case studies of micro-level carbon reduction efforts through industrial energy efficiency technologies are presented. The broader macroeconomic and environmental effects of technology on society are analyzed using data from 206 energy audits of industrial compressed air systems conducted over 13 years. The impacts show that energy-efficient improvements lead to direct cost savings for manufacturers, boost economic activity across sectors, and affect carbon dioxide emissions both short-term and long-term in the region. Given their extensive benefits, energy audits significantly influence policymaking. We devised a methodology to link micro-level energy audit data with macroeconomic and environmental analyses to quantify these cascading benefits. The economic scenario analysis shows that $228 M has been saved from direct industrial energy savings from implementing all compressed air recommendations in the studied periods and the region. In addition, the investment made through manufacturers would create 2,025 jobs and $383 M annually, cascading regional economic impacts. The environmental analysis shows that the regional manufacturers have directly avoided about 2.8 M metric tons of carbon dioxide emissions.

Engineering↗