Development and modeling for a small-scale, rapidly heated high explosives initiation time (HEIT) experiment
Most small-scale assessments of explosive sensitivity, including the popular drop-weight impact test, convolute thermal and mechanical phenomena to the extent that it has been extremely challenging to decipher how an explosive ignites and propagates reactions. For instance, an impact generates heat through a range of dissipation mechanisms, which can in turn, depending on the reaction rates of the explosive, lead to chemical decomposition. To deconvolute the various contributions to the sub-shock initiation and propagation of explosive reactions, we describe the development and modeling of the High Explosives Initiation Time (HEIT) test - a new, small-scale, high-throughput experiment designed to rapidly heat milligram quantities of energetic materials confined within small diameter steel needles. Specifically, we have modeled and designed a 250 joule pulsed power system capable of rapidly delivering electrical current to the needles, resulting in rapid heat delivery to the sample. In conclusion, the energy deposition rate into the sample is controlled by different transmission line topologies. Modeling in COMSOL is performed to understand the energy required to heat up the explosive sample.