Experimental investigation of a bio-based commercial phase change material melting in an inclined rectangular enclosure
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Not provided.
Structurally regular nanopore arrays fabricated to contain independently controllable annular electrodes represent a new kind of architecture capable of electrochemically addressing small collections of matter—down to the single entity (molecule, particle, and biological cell) level. Furthermore, these nanopore electrode arrays (NEAs) can also be interrogated optically to achieve single entity spectroelectrochemistry. Larger entities such as nanoparticles and single bacterial cells are investigated by dark-field scattering and potential-controlled single-cell luminescence experiments, respectively, while NEA-confined molecules are probed by single molecule luminescence. By carrying out these experiments in arrays of identically constructed nanopores, massively parallel collections of single entities can be investigated simultaneously. The multilayer metal–insulator design of the NEAs enables highly efficient redox cycling experiments with large increases in analytical sensitivity for chemical sensing applications. NEAs may also be augmented with an additional orthogonally designed nanopore layer, such as a structured block copolymer, to achieve hierarchically organized multilayer structures with multiple stimulus-responsive transport control mechanisms. Finally, NEAs constructed with a transparent bottom layer permit optical access to the interior of the nanopore, which can result in the cutoff of far-field mode propagation, effectively trapping radiation in an ultrasmall volume inside the nanopore. Furthermore, the bottom metal layer may be used as both a working electrode and an optical cladding layer, thus, producing bifunctional electrochemical zero-mode waveguide architectures capable of carrying out spectroelectrochemical investigations down to the single molecule level.
Not Available
Abstract not provided.
This letter represents the five-day written notification for elevated fluoride levels at the Building 858N, Acid Waste Neutralization (AWN) System in accordance with the ABCWUA Sewer Use and Wastewater Ordinance § 3-6-5(B), Reports of Potential Problems. This AWN System is covered under the ABCWUA Industrial Wastewater Permit No. 2069G. The immediate notification to the ABCWUA occurred at 21:42 on August 1, 2019.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Annual energy savings of up to $\$ 4$ to $\$ 5$ billion could be achieved nationwide through basic insulation and heating system retrofits of existing homes. However, current utility energy efficiency programs are costly and challenging to scale. Customer acquisition occurs primarily through energy bill mailers, mass media, and online advertising that lack specificity about home-specific retrofit opportunities, expected energy savings, and cost-effectiveness. Specific retrofit opportunities are identified via on-site home energy assessments (HEAs) that are inconvenient to homeowners, expensive, and of variable accuracy. We developed computational algorithms that automatically analyze communicating thermostat (CT) heating data that could be used to increase the customer uptake of insulation and air sealing energy conservation measures (ECMs) by identifying homes with the most significant retrofit opportunities, estimating post-retrofit energy savings, and formulating home-specific outreach. The algorithms are based on an extended second-order grey-box model that characterizes a building’s thermal response using lumped elements, coupled with an empirical model of infiltration that accounts for both wind and stack effects. The basic parameters of the model correspond to actual physical parameters of the home, i.e., the home’s overall R-value of and the building envelope ACH50. Unlike the conventional approach, which estimates model parameters based on the best fit to the observed time-dependent room temperature, our approach derives correlations between the daily heating system runtime and temperature difference (indoor-outdoor) that are more robust to data quality issues in real-world applications. We also used HEA data for algorithm development and validation. With the help of our utility partners, Eversource and National Grid, we obtained data sets for hundreds of Massachusetts homes. For each home, these data sets included three sets of information anonymized by the utility: (1) CT data (HVAC runtime, room temperature, and, for some vendors, outdoor temperature and wind speed) collected by the CT vendor (one of three) over a heating season, (2) HEA report performed by the HEA vendor (same vendor for all homes), (3) Monthly utility gas bills coincident with the CT data (3 to 24 per home, depending on availability). For some homes, we also obtained blower-door test results. Initially, we applied the algorithms developed to homes with a single CT and then extended them to homes with two CTs by using an equivalent home approach. Finally, we developed algorithms for prediction of energy savings and a methodology of comparing our predictions with those generated by HEAs. The main technical results indicate that we can reliably identify homes with insulation and/or air sealing retrofit opportunities and provide accurate savings predictions. Our hypothesis is that the algorithms could be applied to utility energy efficiency programs to identify homes that could realize significant energy savings from insulation and/or air sealing retrofits. This information could then be used to reach out to those homes with highly customized outreach, thereby delivering increased program energy savings and cost-effectiveness. This would: Significantly increase the uptake rate of on-site HEAs, and Significantly increase the fraction of HEAs resulting in ECM implementation. To test these hypotheses, we designed and conducted a randomized controlled trial (RCT). The RCT results suggest that personal messaging leads to a two- to five-fold increase in the HEA uptake rate.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A mini split cooling system will be used to maintain temperature requirements in a mobile secure transport system. While the split cooling system was designed to be used in static residential or commercial applications, it was selected for this transportation application due to a unique set of security requirements. However, the system’s ability maintain reliability and survive prolonged long-term shock and vibration is a significant concern. The mitigation strategy is to select vibration isolation mounts and perform lifetime shock and vibration testing to demonstrate survivability. The goal of this study is to generate a finite element model of the system and perform modal analysis to inform selection of vibration mounts to minimize the amount of vibrational energy transferred to the split cooling system. The scope of this report is limited to study of the condensing unit only, and geometric variation of the assembly will not be allowed.
Oak Ridge National Laboratory (ORNL) worked with DowAksa Industry to investigate the potential of using PA66 material to produce larger composite parts, transcending the limitations of traditional presses. The project aimed to develop a suitable material for printing battery boxes using Nylon 66 infused with 40 wt.% carbon fiber, compatible with the ORNL Additive Manufacturing and Compression Molding (AM-CM) system. However, even with extensive work, it was concluded that the material is not compatible with the AMCM process and suitable for joining using compression technique. Main reason for the incompatibility were found to be very high crystallinity of the PA66 grade chosen for this work. To improve printability, a modifier (proprietary) was added to decrease crystallinity, but this led to reduced thermal stability and adhesion issues.
UL Solutions produced this report as a summary of a test series executed at Sandia National Laboratories that they funded. This report was approved for release by UL Solutions in October 2025 and released in 2026 on their website at https://www.ul.com/insights/methods-and-recommendations-large-scale-deflagration-testing-battery-energy-storage-system.