Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical signals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Characterization of quantum well structures using a photocathode electron microscope

Present day integrated circuits pose a challenge to conventional electronic and mechanical test methods. Feature sizes in the submicron and nanometric regime require radical approaches in order to facilitate electrical contact to circuits and devices being tested. In addition, microwave operating frequencies require careful attention to distributed effects when considering the electrical signal paths within and external to the device under test. An alternative testing approach which combines the best of electrical and optical time domain testing is presented, namely photocathode electron microscope quantitative voltage contrast (PEMQVC).

Spencer, Michael G.↗

Emergent discrete space-time crystal of Majorana-like quasiparticles in chiral liquid crystals

Time crystals spontaneously break the time translation symmetry, as recently has been frequently reported in quantum systems. Here we describe the observation of classical analogues of both 1+1-dimensional and 2+1-dimensional discrete space-time crystals in a liquid crystal system driven by a Floquet electrical signal. These classical time crystals comprise particle-like structural features and exists over a wide range of temperatures and electrical driving conditions. The phenomenon-enabling period-doubling effect comes from their topological Majorana-like quasiparticle features, where periodic inter-transformations of co-existing topological solitons and disclinations emerge in response to external stimuli and play pivotal roles. Our discrete space-time crystals exhibit robustness against temporal perturbations and spatial defects, behaving like a time-crystalline analogues of a smectic phase. Our findings show that the simultaneous symmetry breaking in time and space can be a widespread occurrence in numerous open systems, not only in quantum but also in a classical soft matter context.

FOS: Physical sciences↗

Spatiotemporal dynamics of ionic reorganization near biological membrane interfaces

Electrical signals in excitable cells involve spatially localized ionic fluxes through ion channels and pumps on cellular lipid membranes. Common approaches to understand how these fluxes spread assume that the membrane and the surrounding electrolyte comprise an equivalent circuit of capacitors and resistors, which ignores the localized nature of transmembrane ion transport, the resulting ionic gradients and electric fields, and their spatiotemporal relaxation. Here, we consider a model of localized ion pumping across a lipid membrane, and use theory and simulation to investigate how the electrochemical signal propagates spatiotemporally in and out of plane along the membrane. The localized pumping generates long-ranged electric fields with three distinct scaling regimes along the membrane: a constant potential near-field region, an intermediate monopolar region, and a far-field dipolar region. Upon sustained pumping, the monopolar region expands radially in plane with a steady speed that is enhanced by the dielectric mismatch and the finite thickness of the lipid membrane. For unmyelinated lipid membranes in physiological settings, we find remarkably fast propagation speeds of ∼ 40 m / s , allowing faster ionic reorganization compared to bare diffusion. Together, our paper shows that transmembrane ionic fluxes induce transient long-ranged electric fields in electrolyte solutions, which may play hitherto unappreciated roles in biological signaling. Published by the American Physical Society 2025

Row, Hyeongjoo (ORCID:000000033623512X)↗

Size and Structural Control of Mechanoluminescent ZnS:Mn 2+ Nanocrystals for Optogenetic Neuromodulation

Mechanoluminescent materials hold immense potential for various transformative applications, from medical imaging and diagnostics to health monitoring and wearable displays. Conventionally produced as bulk powders or microparticles, they face significant size limitations for advanced applications, particularly in biological systems and microscale devices. Here, this work presents an approach to ZnS:Mn 2+ nanocrystal synthesis that involves self-assembly and subsequent calcination. In addition to effective size control within the nanoscale, this approach promotes the formation of abundant stacking faults, significantly enhancing piezoelectric and mechanoluminescent properties by increasing trap density and reducing trap depth. Unlike mechanoluminescent materials produced using conventional methods, these nanocrystals demonstrate strong mechanoluminescence without requiring UV pre-excitation, and the light emission persists even after mechanical stress is removed. These advantageous properties make them promising candidates for optogenetic neuromodulation, as they can effectively trigger electrical signals in neurons upon ultrasound stimulation both with and without UV pre-excitation. The persistent mechanoluminescence prolongs the duration of neuronal electrical activity, providing an extended temporal window for neuromodulation compared to conventional mechanoluminescent materials. This study provides a scalable method for producing efficient mechanoluminescent nanoparticles and reveals the crucial role of particle size and defect structures in determining their mechanoluminescent behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data storage, image tube type

Method and apparatus for the storage of digital or analog electrical signals are provided by a memory storage system employing a conventional vidicon tube. At the beginning of an operating cycle, the vidicon is conditioned to accept electrical data input by exposing its photosensitive target to a short, high intensity light flash. A first electron beam scan of the photosensitive surface then sets up a charge pattern on the photosensitive target. A second electron beam scan of the photosensitive surface by an unmodulated electron beam then develops an output signal across an output resistor by using capacitive currents. The conditioning and scanning steps are operated repetitively at high speed using conventional television camera scan, sync, and power supply circuitry to provide a low cost data storage system.

Lipoma, P. C.↗

Integrated Electrode Arrays for Neuro-Prosthetic Implants

Arrays of electrodes integrated with chip-scale packages and silicon-based integrated circuits have been proposed for use as medical electronic implants, including neuro-prosthetic devices that might be implanted in brains of patients who suffer from strokes, spinal-cord injuries, or amyotrophic lateral sclerosis. The electrodes of such a device would pick up signals from neurons in the cerebral cortex, and the integrated circuit would perform acquisition and preprocessing of signal data. The output of the integrated circuit could be used to generate, for example, commands for a robotic arm. Electrode arrays capable of acquiring electrical signals from neurons already exist, but heretofore, there has been no convenient means to integrate these arrays with integrated-circuit chips. Such integration is needed in order to eliminate the need for the extensive cabling now used to pass neural signals to data-acquisition and -processing equipment outside the body. The proposed integration would enable progress toward neuro-prostheses that would be less restrictive of patients mobility. An array of electrodes would comprise a set of thin wires of suitable length and composition protruding from and supported by a fine-pitch micro-ball grid array or chip-scale package (see figure). The associated integrated circuit would be mounted on the package face opposite the probe face, using the solder bumps (the balls of the ball grid array) to make the electrical connections between the probes and the input terminals of the integrated circuit. The key innovation is the insertion of probe wires of the appropriate length and material into the solder bumps through a reflow process, thereby fixing the probes in place and electrically connecting them with the integrated circuit. The probes could be tailored to any distribution of lengths and made of any suitable metal that could be drawn into fine wires. Furthermore, the wires could be coated with an insulating layer using anodization or other processes, to achieve the correct electrical impedance. The probe wires and the packaging materials must be biocompatible using such materials as lead-free solders. For protection, the chip and package can be coated with parylene.

Brandon, Erik↗

Investigation of modified uni-traveling carrier photodiode for cryogenic microwave photonic links

Quantum devices present the potential for unparalleled computing and communications capabilities; however, the cryogenic temperatures required to successfully control and read out many qubit platforms can prove to be very challenging to scale. Recently, there has emerged an interest in using microwave photonics to deliver control signals down to ultracold stages via optical fiber, thereby reducing thermal load and facilitating dense wavelength multiplexing. Photodetectors can then convert this optical energy to electrical signals for qubit control. The fidelity of the quantum operations of interest therefore depend heavily upon the characteristics of the photodiode, yet experimental demonstrations of fiber-coupled photodetection systems at low temperatures are relatively few in number, leaving important open questions regarding how specific detectors may perform in real-world cryogenic settings. In this work, we examine a highly linear modified uni-traveling carrier photodiode (MUTC-PD) under C-band illumination (1530–1565 nm) at three temperature regimes (300 K, 80 K, and ∼4 K) and multiple bias conditions. Our findings of reduced responsivity but preserved bandwidth are consistent with previous studies, while our saturation tests suggest a variety of potential applications for MUTC-PDs in cryogenic microwave photonics with and without electrical bias. Overall, our results should provide a valuable foundation for the continued and expanding use of this detector technology in quantum information processing.

47 OTHER INSTRUMENTATION↗

Photocapacitive image converter

An apparatus for converting a radiant energy image into corresponding electrical signals including an image converter is described. The image converter includes a substrate of semiconductor material, an insulating layer on the front surface of the substrate, and an electrical contact on the back surface of the substrate. A first series of parallel transparent conductive stripes is on the insulating layer with a processing circuit connected to each of the conductive stripes for detecting the modulated voltages generated thereon. In a first embodiment of the invention, a modulated light stripe perpendicular to the conductive stripes scans the image converter. In a second embodiment a second insulating layer is deposited over the conductive stripes and a second series of parallel transparent conductive stripes perpendicular to the first series is on the second insulating layer. A different frequency current signal is applied to each of the second series of conductive stripes and a modulated image is applied to the image converter.

Miller, W. E.↗

Frequency tracked gated pulse technique for ultrasonic frequency

A tracking generator 21 is slaved to a spectrum analyzer 23 to produce an input signal having a frequency that follows the frequency of the spectrum analyzer sweeping local oscillator 22. The input signal is gated to a transducer 26 by a transmitter gate 25 to produce ultrasonic waves in the sample 28. The resulting ultrasonic echoes are converted into electrical signals by the transducer and then gated into the spectrum analyzer by receiver gate 29. This arrangement produces spectra that are equivalent to shock-exciting the transducer with a true delta function shock-excitation.

Cantrell, Jr., John H.↗

3D printable feedstock inks for signal control or computation

In one aspect the present disclosure relates to a 3D printed signal control backbone apparatus. The apparatus may have a filament including a first material section and a plurality of second material sections. The first material section is bounded on opposing ends by the second material sections. The first material section is formed by an ink having a percolating network of a plurality of chiplets infused in a non-conductive polymer. The plurality of chiplets form electrically responsive elements imparting a predetermined logic function and which are responsive to a predetermined electrical signal. The second material sections are formed by an ink which is electrically conductive.

Murialdo, Maxwell↗

Radiation Shielding System Using a Composite of Carbon Nanotubes Loaded with Electropolymers

Single-wall carbon nanotubes (SWCNTs) coated with a hydrogen-rich, electrically conducting polymer such as polyethylene, receive and dissipate a portion of incoming radiation pulse energy to electrical signals that are transmitted along the CNT axes, and are received at energy-dissipating terminals. In this innovation, an array of highly aligned nanowires is grown using a strong electric field or another suitable orientation procedure. Polyethylene (PE), polymethymlethacrylate (PMMA), or other electrically conducting polymer is spin-coated onto the SWCNTs with an average thickness of a few hundred nanometers to a few tenths of micrometers to form a PE/SWCNT composite. Alternatively, the polymer is spin-coated onto the nanowire array or an anodized alumina membrane (AAM) to form a PE/metal core shell structure, or PE can be electropolymerized using the SWCNTs or the metal nanowires as an electrode to form a PE/SWCNT core shell structure. The core shell structures can be extruded as anisotropic fibers. A monomer can be polymerized in the presence of SWCNTs to form highly cross-linked PE/SWCNT films. Alternatively, Pb colloid solution can be impregnated into a three-dimensional PE/SWCNT nanostructure to form a PW/SWCNT/Pb composite structure. A face-centered cubic (FCC) arrangement provides up to 12 interconnection channels connected to each core, with transverse channel dimensions up to 20 nm, with adequate mechanical compressive strength, and with an associated electrical conductivity of around 3 Seimens/cm for currents ranging from 0.01 to 10 mA. This threedimensional nanostructure is used as a host material to house appropriate radiation shielding material such as hydrogen- rich polymer/CNT structures, metal nanoparticles, and nanowires. Thicknesses of this material required to attenuate 10 percent, 50 percent, and 90 percent of an incident beam (gamma, X-ray, ultraviolet, neutron, proton, and electron) at energies in the range of 0 440 MeV are being determined, for example, by measuring fluence rate reduction. For example, a radiation field arrives first at an exposed surface of the innovation and produces an associated first electric field within the metal-like fingers of the three-dimensional nanostructure. This field is intensified near the exposed tips of the fingers, and this intensified field generates an intensified second electric field near the adjacent exposed tips of the coated CNSs. This generates an associated electrical current in the CNSs, and the associated electropolymer coating. The current is received by the second substrate transport component and is transported to the dissipation mechanism located contiguously to the second substrate.

McKay, Chris↗

Manipulating cobalt oxide on N-doped aligned electrospun carbon nanofibers towards instant electrochemical detection of dopamine secreted by living cells

A demand exists for the development of miniaturized biosensors with high sensitivity and a wide dynamic range for rapid detecting dopamine (DA) levels. Here, an electrochemical sensor is created by decorating closely packed cobalt oxide (Co 3 O 4 ) nanograins on nitrogen-doped electrospun carbon nanofibers (NECNFs) via a facile electrodeposition method. The carbon nanofiber matrix provides both a scaffold with ultrahigh surface area for homogeneous dispersion of cobalt oxide nanostructures and facilitates the electrochemical conductivity for the hybrid electrode. The sensing principle is based on the redox reaction between DA and DA quinone that generates electrical signal, which is detectable via differential pulse voltammetry (DPV) and chronoamperometry (CA). Owing to a high electroactive surface area and facilitating electron transfer between electrode surface and the target molecule, the electrical sensing platform exhibits superior sensitivity and selectivity toward DA, with an excellent limit of detection (9 nM) over a wide range of concentrations (0.01 to 100 μM). Moreover, based on its excellent sensing properties and biocompatibility, the sensor has been used for the real-time monitoring exogeneous DA released from pheochromocytoma (PC12) cells. This work demonstrates promise of a novel sensor technology that may render rapid point-of-care testing of DA towards early clinical diagnosis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neuro-Prosthetic Implants With Adjustable Electrode Arrays

Brushlike arrays of electrodes packaged with application-specific integrated circuits (ASICs) are undergoing development for use as electronic implants especially as neuro-prosthetic devices that might be implanted in brains to detect weak electrical signals generated by neurons. These implants partly resemble the ones reported in Integrated Electrode Arrays for Neuro-Prosthetic Implants (NPO-21198), NASA Tech Briefs, Vol. 27, No. 2 (February 2003), page 48. The basic idea underlying both the present and previously reported implants is that the electrodes would pick up signals from neurons and the ASICs would amplify and otherwise preprocess the signals for monitoring by external equipment. The figure presents a simplified and partly schematic view of an implant according to the present concept. Whereas the electrodes in an implant according to the previously reported concept would be microscopic wires, the electrodes according to the present concept are in the form of microscopic needles. An even more important difference would be that, unlike the previously reported concept, the present concept calls for the inclusion of microelectromechanical actuators for adjusting the depth of penetration of the electrodes into brain tissue. The prototype implant now under construction includes an array of 100 electrodes and corresponding array of electrode contact pads formed on opposite faces of a plate fabricated by techniques that are established in the art of microelectromechanical systems (MEMS). A mixed-signal ASIC under construction at the time of reporting the information for this article will include 100 analog amplifier channels (one amplifier per electrode). On one face of the mixed-signal ASIC there will be a solder-bump/micro-pad array that will have the same pitch as that of the electrode array, and that will be used to make the electrical and mechanical connections between the electrode array and the ASIC. Once the electrode array and the ASIC are soldered together, the remaining empty space between them will be filled with a biocompatible epoxy, the remaining exposed portions of the ASIC will be covered with micromachined plates for protection against corrosive bodily fluids, and then the ASIC and its covering micromachined plates will be coated with parylene

Whitacre, Jay↗

Protobiological informatoin, bidirectional recognition and reverse translation

Emergence of protobiological information has been suggested by experiments in which heated mixtures of alpha-amino acids order themselves into a self limited array of thermal proteins. The polymers display selective catalytic, hormonal, and other activities. Interactions of varied cationic thermal proteins with polynucleotides indicate selective recognition in both directions. Reverse translation is partly a missing link in the molecular evolution flowsheet. The self ordering of amino acids serves conceptually as a deterministic evolutionary precursor of the modern coding mechanism. The possibility for the evolution of information at an early nontemplated protein stage is supported by findings of electrical signals from proteinoid microspheres prepared with no DNA/RNA in their history. The deposition of thermal copolyamino acids on lipid membranes in the Mueller-Rudin apparatus has here been found to produce electrical behavior like that evoked by bacterial EIM polypeptide. A new procedure is to make a film of membrane on the electrode; the results provide maximal repeatability. The principle of nonrandom biomacromolecular specificity identified by these studies in molecular evolution have been extrapolated to principles of evolution of advanced organisms.

Fox, S. W.↗

Physical insights into biological memory using phospholipid membranes

Electrical signals may propagate along neuronal membranes in the brain, thus enabling communication between nerve cells. In doing so, lipid bilayers, fundamental scaffolds of all cell membranes, deform and restructure in response to such electrical activity. These changes impact the electromechanical properties of the membrane, which then physically store biological memory. This memory can exist either over a short or long period of time. Traditionally, biological memory is defined by the strengthening or weakening of transmissions between individual neurons. In this report we show that electrical stimulation may also alter the properties of the lipid membrane, thus pointing toward a novel mechanism for memory storage. Furthermore, based on the analysis of existing electrophysiological data, we study molecular mechanisms underlying the long-term potentiation in phospholipid membranes. Finally, we examine possible relationships between the memory capacitive properties of lipid membranes, neuronal learning, and memory.

59 BASIC BIOLOGICAL SCIENCES↗

Detecting Conductive Liquid Leaking from Nonconductive Pipe

A method that can be implemented with relatively simple electronic circuitry provides a capability for detecting leakage of an electrically conductive liquid from an electrically nonconductive underground pipe. Alternatively or in addition, the method can be applied to locate the pipe, whether or not there is a leak. Although the method is subject to limitations (some of which are described below), it is still attractive as an additional option for detecting leaks and locating pipes without need for extensive digging. The method is based on capacitive coupling of an alternating electrical signal from the liquid to a portable electronic unit that resembles a metal detector. A signal voltage is applied to the liquid at some convenient point along the pipe: for example, the signal could be coupled into the liquid via an aboveground metal pipe fitting, the interior surface of which is in contact with the liquid. The signal is conducted through the liquid in the pipe; in the case of diffusive leak of liquid into the surrounding ground, the signal is conducted through the leak, into the portion of the adjacent ground that has become soaked with the liquid. (A drip leak cannot be detected by this method because there is no conductive path between the liquid inside and the liquid outside the pipe.) The portable unit includes an electrically conductive plate connected to the input terminal of an amplifier. When the plate is brought near the pipe or the leaked liquid, a small portion of the signal power is coupled capacitively from the liquid to the plate. The user scans the plate near the ground surface to find the locus of maximum signal strength. The leak can be identified as a relatively wide area, contiguous with the location of the pipe, over which the signal is detectable.

Youngquist, Robert C.↗

Coherent electrical control of a single high-spin nucleus in silicon

Nuclear spins are highly coherent quantum objects. In large ensembles, their control and detection via magnetic resonance is widely exploited, for example, in chemistry, medicine, materials science and mining. Nuclear spins also featured in early proposals for solid-state quantum computers and demonstrations of quantum search and factoring algorithms. Scaling up such concepts requires controlling individual nuclei, which can be detected when coupled to an electron. However, the need to address the nuclei via oscillating magnetic fields complicates their integration in multi-spin nanoscale devices, because the field cannot be localized or screened. Control via electric fields would resolve this problem, but previous methods relied on transducing electric signals into magnetic fields via the electron–nuclear hyperfine interaction, which severely affects nuclear coherence. In this work, we demonstrate the coherent quantum control of a single 123 Sb (spin-7/2) nucleus using localized electric fields produced within a silicon nanoelectronic device. The method exploits an idea proposed in 1961 but not previously realized experimentally with a single nucleus. Our results are quantitatively supported by a microscopic theoretical model that reveals how the purely electrical modulation of the nuclear electric quadrupole interaction results in coherent nuclear spin transitions that are uniquely addressable owing to lattice strain. The spin dephasing time, 0.1 seconds, is orders of magnitude longer than those obtained by methods that require a coupled electron spin to achieve electrical driving. These results show that high-spin quadrupolar nuclei could be deployed as chaotic models, strain sensors and hybrid spin-mechanical quantum systems using all-electrical controls. Integrating electrically controllable nuclei with quantum dots could pave the way to scalable, nuclear- and electron-spin-based quantum computers in silicon that operate without the need for oscillating magnetic fields.

42 ENGINEERING↗

Electro-optic crystals and their use for light modulation

Several methods of modulating a beam of light, which have been described in the literature, utilizing the influence of an electrical signal on the birefringence of certain crystals, will be reviewed. These employ optics which respond to the state of polarization of a light beam, and include intensity modulation, position modulation, and the possibility of an electrically tuned optical filter. The influence of the piezo-optic, or strain contribution to the total electro-optic response in the design of an optoelectronic device will be discussed. Current experimental work in our laboratory in which the strain contribution is separated from the direct effect will be described. The strain-free effect is measured by applying a step voltage to the crystal, and observing the initial response. The electro-optical transient response can be observed with nanosecond time resolution. An electronic sampling technique is used to extract the desired response from photon noise. The stress-free or low-frequency effect is measured similarly but at low audio frequencies. Single crystal tetragonal BaT10 3 has been investigated in detail with the result that the strain-optic contribution to the low frequency effect r_(c) = r_(33)—r_(13) is about 80% of the total, where it is only 10% in KDP and 45% in ADP. The magnitudes of the electro-optic effect, dielectric constant, and other related properties are compared for several materials potentially useful as electro-optic modulators, and some comments are made about the practical problems of building a modulator.

ELECTRO-OPTICS↗