Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical components”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Selective Heating Through Y-Junction Waveguide Designed by Acoustic Shape Optimization

Unlike phononic crystals or systems designed by topology optimization, waveguides designed by shape optimization do not have voids or internal defects, making the fabrication process more suitable for additive manufacturing. By designing a Y-junction waveguide through shape optimization, an ultrasonic wave can be controlled so that it propagates to a predetermined location just by adjusting its frequency. These demultiplexed ultrasonic waves can be used to transport signals or stimulate nearby materials. As an example, the ultrasonic wave is converted to heat at different locations, which can be applied to mechanisms that can take advantage of heating. First, shape optimization is performed on a cylindrical structure to selectively propagate ultrasonic waves of a particular frequency while attenuating others, which is analyzed through a finite element model. The numerical study results are compared with experimental measurements from samples fabricated through additive manufacturing methods. After verifying the concept, the Y-junction waveguide is fabricated to demultiplex the wave and selectively heat different locations. Here the results show that the method of combining shape optimization with additive manufacturing is exceptionally simple and capable of demultiplexing ultrasonic waves, which can replace complex electrical components with single-material waveguides.

36 MATERIALS SCIENCE↗

Impact of ion fluxes across thylakoid membranes on photosynthetic electron transport and photoprotection

In photosynthetic thylakoid membranes the proton motive force (pmf) not only drives ATP synthesis, in addition it is central to controlling and regulating energy conversion. As a consequence, dynamic fine-tuning of the two pmf components, electrical (Δψ) and chemical (ΔpH), is an essential element for adjusting photosynthetic light reactions to changing environmental conditions. Good evidence exists that the Δψ/ΔpH partitioning is controlled by thylakoid potassium and chloride ion transporters and channels. However, a detailed mechanistic understanding of how these thylakoid ion transporter/channels control pmf partitioning is lacking. In this work, we combined functional measurements on potassium and chloride ion transporter and channel loss-of-function mutants with extended mathematical simulations of photosynthetic light reactions in thylakoid membranes to obtain detailed kinetic insights into the complex interrelationship between membrane energization and ion fluxes across thylakoid membranes. The data reveal that potassium and chloride fluxes in the thylakoid lumen determined by the K + /H + antiporter KEA3 and the voltage-gated Cl – channel VCCN1/Best1 have distinct kinetic responses that lead to characteristic and light-intensity-dependent Δψ/ΔpH oscillations. These oscillations fine-tune photoprotective mechanisms and electron transport which are particularly important during the first minutes of illumination and under fluctuating light conditions. By employing the predictive power of the model, we unravelled the functional consequences of changes in KEA3 and VCCN1 abundance and regulatory/enzymatic parameters on membrane energization and photoprotection.

59 BASIC BIOLOGICAL SCIENCES↗

Managing Power Systems-Induced Wildfire Risks Using Optimal Scheduled Shutoffs

The increasing demands for electricity and the increase in extreme weather conditions are putting unprecedented pressure on our electric grids. Often, this pressure leads to electrical component failures, which might ignite wildfires. This work develops a novel model to balance the reliability of power network operations and the risk of wildfire ignition by opti- mizing the operational schedule of power transmission networks considering time-varying risk measures that include exogenous and operational factors. Energy storage systems are considered to deliver power during peak wildfire hours and enable temporal load shifting. The problem is formulated as a mixed-integer linear program that maximizes a weighted sum of the served power demand and the reduction in grid-induced wildfire risk. The results demonstrate the ability of the model to significantly reduce wildfire risk without considerable load shedding.

power systems operations↗

Resilience Assessment for Distribution Systems during Hurricanes: A Learning-Based Framework

This paper presents a proactive strategy for hurricane-resilient distribution systems. It proposes a Bayesian Neural Network-based outage prediction model considering various parameters, including electrical components, and weather and environmental factors. Addressing challenges in imbalanced outage datasets, a Bias-Variance Tradeoff method is proposed. A resilience assessment model quantifies resilience indices, providing insights into system weaknesses. The approach identifies weak points and serves as a planning benchmark. Numerical results on the modified IEEE 123-node test system demonstrate effectiveness in realistic hurricane scenarios.

Vahedi, Soroush↗

SRNL Coulometer for LANL - SRNL-Testing 2020 (Final Report)

SRNL fabricated two coulometers that have been delivered to LANL. All testing for electrical components is performed by R&D engineering and the results are attached to this report. Instrument testing for the first instrument was completed on August 2018 and installation at LANL was completed February 2019. This report addresses testing performed at FH Analytical Laboratory for the second instrument that arrived at LANL on June 5th, 2020. The testing is performed using Plutonium working standards. The instrument was kept in a radiologically clean area. The component calibration of the second LANL coulometer was completed in SRNL Building 723-A.

47 OTHER INSTRUMENTATION↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Precitech N200 Lathe Refurbish/Upgrade Project [Slides]

Background: LANL purchased two Precitech N200 Lathes in 2002; Machines were modified for glovebox operations; First lathe became operational in 2009; After nearly 15 years of continuous operation, electric components have started to fail; Precitech has been refurbishing N200 lathes for other 20 years; Existing lathes in PF-4 needed for surveillances/certification missions; after training at Precitech, LANL workers will perform refurbishment/upgrade tasks in PF-4.

42 ENGINEERING↗

Task 12 PV Sustainability - Life Cycle Inventories and Life Cycle Assessments of Photovoltaic Systems

Life Cycle Assessment (LCA) is a structured, comprehensive method of quantifying material- and energy-flows and their associated impacts in the life cycles of products (i.e., goods and services). One of the major goals of IEA PVPS Task 12 is to provide guidance on assuring consistency, balance, transparency and quality of LCA to enhance the credibility and reliability of the results. The current report presents the latest consensus life cycle inventories among the authors, PV LCA experts in North America, Europe, Asia and Australia. At this time consensus is limited to four technologies for which there are well-established and up-to-date life cycle inventory (LCI) data (mono- and multi-crystalline Si, CdTe, CIGS, as well as one emerging technology (perovskite silicon tandem). LCIs are necessary for LCA and the availability of such data is often the greatest barrier for conducting LCA. The Task 12 LCA experts have put great efforts in gathering and compiling the LCI data presented in this report. These include detailed inputs and outputs during manufacturing of cell, wafer, module, and balance-of-system (i.e., structural and electrical components) that were estimated from actual production and operation facilities. In addition, data are presented to enable analyses of various types of PV installations; these include operational data of rooftop and ground-mount PV systems and country-specific PV-mixes. The LCI datasets presented in this report are the latest that are available to the public describing the status in 2018 for crystalline Si (some manufacturing data from 2011 were not updated), 2015 and 2017-2018 for CdTe, 2010 for CIGS, 2010 for HCPV, and 2017 for perovskite silicon tandem technology.

14 SOLAR ENERGY↗

RECON Label Quality Report

The final quality of any AI/ML system is directly related to the quality of the input data used to train the system. In this case, we are trying to build a reliable image classifier that can correctly identify electrical components in x-ray images. The classification confidence is directly related to the quality of the labels in the training data, which are used in developing the AI/ML classifier. Incorrect or incomplete labels can substantially hinder the performance of the system during the training process, as it tries to compensate for variations that should not exist. Image labels are entered by subject matter experts, and in general can be assumed to be correct. However, this is not a guarantee, so developing ways to measure label quality and help identify or reject bad labels is important, especially as the database continues to grow. Given the current size of the database, a full manual review of each component is not feasible. This report will highlight the current state of the “RECON” x-ray image database and summarize several recent developments to try to help ensure high quality labeling both now and in the future. Questions that we hope to answer with this development include: 1) Are there any components with incorrect labels? 2) Can we suggest labels for components that are marked “Unknown”? 3) What kind of overall confidence do we have in the quality of the existing labels? 4) What systems or procedures can we put in place to maximize label quality?

42 ENGINEERING↗

FY25 Mid-Year Report: FABIA In-Field Laser Absorption Spectroscopy for UF6 Enrichment

From September 2024 through April 2025, the FABIA team has been working towards completing the IAEA requirements for technology transfer of the instrument. The primary tasks in place for this transfer are to complete a validation study using various enrichments of UF6, to finalize the data analysis routines in the FABIA software, and to complete FABIA electrical component compatibility. These topics are expanded in greater detail below. In addition to the tasks, the FABIA team hosted IAEA representatives to observe a live analysis demonstration of the FABIA instrument on February 3, 2025. As a result of this visit, some updates to the tasks were communicated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New tungsten alloy has high strength at elevated temperatures

Tungsten-hafnium-carbon alloy has tensile strengths of 88,200 psi at 3000 deg F and 62,500 psi at 3500 deg F. Possible industrial applications for this alloy would include electrical components such as switches and spark plugs, die materials for die casting steels, and heating elements.

Source record↗

Method of disjoining adhesively bonded electronic cordwood modules

Embedment of resistive heating elements in a cordwood module used for packaging electronic components, facilitates separation of the adhesive bond between the module, and metal heat sink and the potting material without damaging the components. Electrical power applied to the elements causes breakdown of bonding material.

Sacramone, P. J.↗

Thermally conductive polymers

A thermally conductive polymer is provided having physical and chemical properties suited to use as a medium for potting electrical components. The polymer is prepared from hydroquinone, phenol, and formaldehyde, by conventional procedures employed for the preparation of phenol-formaldehyde resins. While the proportions of the monomers can be varied, a preferred polymer is formed from the monomers in a 1:1:2.4 molar or ratio of hydroquinone:phenol:formaldehyde.

Byrd, N. R.↗

Processing of thermionic power on an electrically propelled spacecraft

A study to define the power processing equipment required between a thermionic reactor and an array of mercury-ion thrusters for a nuclear electric propulsion system is reported. Observations and recommendations that resulted from this study were: (1) the preferred thermionic-fuel-element source voltages are 23 V or higher; (2) transistor characteristics exert a strong effect on power processor mass; (3) the power processor mass could be considerably reduced should the magnetic materials that exhibit low losses at high frequencies, that have a high Curie point, and that can operate at 15 to 20 kG become avaliable; (4) electrical component packaging on the radiator could reduce the area that is sensitive to meteoroid penetration, thereby reducing the meteoroid shielding mass requirement; (5) an experimental model of the power processor design should be built and tested to verify the efficiencies, masses, and all the automatic operational aspects of the design.

Macie, T. W.↗