Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EYES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Experimental tests of a superposition hypothesis to explain the relationship between the vestibuloocular reflex and smooth pursuit during horizontal combined eye-head tracking in humans

1. We used a modeling approach to test the hypothesis that, in humans, the smooth pursuit (SP) system provides the primary signal for cancelling the vestibuloocular reflex (VOR) during combined eye-head tracking (CEHT) of a target moving smoothly in the horizontal plane. Separate models for SP and the VOR were developed. The optimal values of parameters of the two models were calculated using measured responses of four subjects to trials of SP and the visually enhanced VOR. After optimal parameter values were specified, each model generated waveforms that accurately reflected the subjects' responses to SP and vestibular stimuli. The models were then combined into a CEHT model wherein the final eye movement command signal was generated as the linear summation of the signals from the SP and VOR pathways. 2. The SP-VOR superposition hypothesis was tested using two types of CEHT stimuli, both of which involved passive rotation of subjects in a vestibular chair. The first stimulus consisted of a "chair brake" or sudden stop of the subject's head during CEHT; the visual target continued to move. The second stimulus consisted of a sudden change from the visually enhanced VOR to CEHT ("delayed target onset" paradigm); as the vestibular chair rotated past the angular position of the stationary visual stimulus, the latter started to move in synchrony with the chair. Data collected during experiments that employed these stimuli were compared quantitatively with predictions made by the CEHT model. 3. During CEHT, when the chair was suddenly and unexpectedly stopped, the eye promptly began to move in the orbit to track the moving target. Initially, gaze velocity did not completely match target velocity, however; this finally occurred approximately 100 ms after the brake onset. The model did predict the prompt onset of eye-in-orbit motion after the brake, but it did not predict that gaze velocity would initially be only approximately 70% of target velocity. One possible explanation for this discrepancy is that VOR gain can be dynamically modulated and, during sustained CEHT, it may assume a lower value. Consequently, during CEHT, a smaller-amplitude SP signal would be needed to cancel the lower-gain VOR. This reduction of the SP signal could account for the attenuated tracking response observed immediately after the brake. We found evidence for the dynamic modulation of VOR gain by noting differences in responses to the onset and offset of head rotation in trials of the visually enhanced VOR.(ABSTRACT TRUNCATED AT 400 WORDS).

Non-NASA Center↗

Dynamic Light Scattering Developed to Look Through the Eye's Window Into the Body

Microgravity researcher Dr. Rafat R. Ansari, from the NASA Glenn Research Center, has found that the eye operates much like a camera and is the "window to the body." The eye contains transparent tissue through which light passes, providing us a view of what's going on inside. These transparent tissues represent nearly every tissue type that exists throughout the body. With the correlations and comparisons of these tissues done at Glenn, we hope to improve doctors' ability to diagnose diseases at much earlier stages. The medical community will be able to look noninvasively and quantitatively into a patient's eyes to detect disease before symptoms appear. Since the eye is easily accessed by light, the optical technologies created at Glenn can be used to evaluate its structure and physiology in health, aging, and disease.

Stauber, Laurel J.↗

Anticipatory Eye Movements in Interleaving Templates of Human Behavior

Performance modeling has been made easier by architectures which package psychological theory for reuse at useful levels of abstraction. CPM-GOMS uses templates of behavior to package at a task level (e.g., mouse move-click, typing) predictions of lower-level cognitive, perceptual, and motor resource use. CPM-GOMS also has a theory for interleaving resource use between templates. One example of interleaving is anticipatory eye movements. This paper describes the use of ACT-Stitch, a framework for translating CPM-GOMS templates and interleaving theory into ACT-R, to model anticipatory eye movements in skilled behavior. The anticipatory eye movements explain performance in a well-practiced perceptual/motor task, and the interleaving theory is supported with results from an eye-tracking experiment.

Matessa, Michael↗

Persistent Seroconversion after Accidental Eye Exposure to Calcifying Nanoparticles

Biosafety of nanomaterials has attracted much attention recently. We report here a case where accidental human eye exposure to biogenic nanosized calcium phosphate in the form of calcifying nanoparticles (CNP) raised a strong IgG immune response against proteins carried by CNP. The antibody titer has persisted over ten years at the high level. The IgG was detected by ELISA using CNPs propagated in media containing bovine and human serum as antigen. The exposure incident occurred to a woman scientist (WS) at a research laboratory in Finland at 1993. CNP, also termed "nanobacteria", is a unique self-replicating agent that has not been fully characterized and no data on biohazards were available at that time. Before the accident, her serum samples were negative for both CNP antigen and anti-CNP antibody using specific ELISA tests (Nanobac Oy, Kuopio, Finland). The accident occurred while WS was harvesting CNP cultures. Due to a high pressure in pipetting, CNP pellet splashed into her right eye. Both eyes were immediately washed with water and saline. The following days there was irritation and redness in the right eye. These symptoms disappeared within two weeks without any treatment. Three months after the accident, blood and urine samples of WS were tested for CNP cultures (2), CNP-specific ELISA tests, and blood cell counts. Blood cell counts were normal, CNP antigen and culture tests were negative. A high IgG anti-CNP antibody titer was detected (see Figure). The antibodies of this person have been used thereafter as positive control and standard in ELISA manufacturing (Nano-Sero IgG ELISA, Nanobac Oy, Kuopio, Finland).

Ciftcioglu, Neva↗

Assessing blood brain barrier dynamics or identifying or measuring selected substances or toxins in a subject by analyzing Raman spectrum signals of selected regions in the eye

A non-invasive method for analyzing the blood-brain barrier includes obtaining a Raman spectrum of a selected portion of the eye and monitoring the Raman spectrum to ascertain a change to the dynamics of the blood brain barrier. Also, non-invasive methods for determining the brain or blood level of an analyte of interest, such as glucose, drugs, alcohol, poisons, and the like, comprises: generating an excitation laser beam (e.g., at a wavelength of 600 to 900 nanometers); focusing the excitation laser beam into the anterior chamber of an eye of the subject so that aqueous humor, vitreous humor, or one or more conjunctiva vessels in the eye is illuminated; detecting (preferably confocally detecting) a Raman spectrum from the illuminated portion of the eye; and then determining the blood level or brain level (intracranial or cerebral spinal fluid level) of an analyte of interest for the subject from the Raman spectrum. In certain embodiments, the detecting step may be followed by the step of subtracting a confounding fluorescence spectrum from the Raman spectrum to produce a difference spectrum; and determining the blood level and/or brain level of the analyte of interest for the subject from that difference spectrum, preferably using linear or nonlinear multivariate analysis such as partial least squares analysis. Apparatus for carrying out the foregoing methods are also disclosed.

Lambert, James L.↗

Studies of the Ability to Hold the Eye in Eccentric Gaze: Measurements in Normal Subjects with the Head Erect

We studied the ability to hold the eyes in eccentric horizontal or vertical gaze angles in 68 normal humans, age range 19-56. Subjects attempted to sustain visual fixation of a briefly flashed target located 30 in the horizontal plane and 15 in the vertical plane in a dark environment. Conventionally, the ability to hold eccentric gaze is estimated by fitting centripetal eye drifts by exponential curves and calculating the time constant (t(sub c)) of these slow phases of gazeevoked nystagmus. Although the distribution of time-constant measurements (t(sub c)) in our normal subjects was extremely skewed due to occasional test runs that exhibited near-perfect stability (large t(sub c) values), we found that log10(tc) was approximately normally distributed within classes of target direction. Therefore, statistical estimation and inference on the effect of target direction was performed on values of z identical with log10t(sub c). Subjects showed considerable variation in their eyedrift performance over repeated trials; nonetheless, statistically significant differences emerged: values of tc were significantly higher for gaze elicited to targets in the horizontal plane than for the vertical plane (P less than 10(exp -5), suggesting eccentric gazeholding is more stable in the horizontal than in the vertical plane. Furthermore, centrifugal eye drifts were observed in 13.3, 16.0 and 55.6% of cases for horizontal, upgaze and downgaze tests, respectively. Fifth percentile values of the time constant were estimated to be 10.2 sec, 3.3 sec and 3.8 sec for horizontal, upward and downward gaze, respectively. The difference between horizontal and vertical gazeholding may be ascribed to separate components of the velocity position neural integrator for eye movements, and to differences in orbital mechanics. Our statistical method for representing the range of normal eccentric gaze stability can be readily applied in a clinical setting to patients who were exposed to environments that may have modified their central integrators and thus require monitoring. Patients with gaze-evoked nystagmus can be flagged by comparing to the above established normative criteria.

Reschke, Millard F.↗

Eye Tracking Metrics for Workload Estimation in Flight Deck Operation

Flight decks of the future are being enhanced through improved avionics that adapt to both aircraft and operator state. Eye tracking allows for non-invasive analysis of pilot eye movements, from which a set of metrics can be derived to effectively and reliably characterize workload. This research identifies eye tracking metrics that correlate to aircraft automation conditions, and identifies the correlation of pilot workload to the same automation conditions. Saccade length was used as an indirect index of pilot workload: Pilots in the fully automated condition were observed to have on average, larger saccadic movements in contrast to the guidance and manual flight conditions. The data set itself also provides a general model of human eye movement behavior and so ostensibly visual attention distribution in the cockpit for approach to land tasks with various levels of automation, by means of the same metrics used for workload algorithm development.

Ellis, Kyle↗

The Walk on Floor Eyes Closed Tandem Step Test as a Quantitative Measure of Ataxia After Space Flight

INTRODUCTION Posture and locomotion are among the functions most affected by space flight. Postflight ataxia can be quantified easily by using the walk on the floor line test with the eyes closed (WOFEC). Data from a modified WOFEC were obtained as part of an ongoing interdisciplinary pre- and postflight study (Functional Task Test, FTT) designed to evaluate both postflight functional performance of astronauts and related physiological changes. METHODS Five astronauts with flight durations of 12 to 16 days participated in this study. Performance measurements were obtained in 2 preflight sessions, on landing day, and 1, 6, and 30 days after landing. The WOFEC test consisted of walking with the feet placed heel to toe in tandem, arms folded across the chest and eyes closed, for 10 steps. A trial was initiated after the eyes were closed and the front foot was aligned with the rear foot. The performance metric was the average percentage of correct steps completed over 3 trials. A step was not counted as correct if the crewmember sidestepped, opened eyes, or paused for more than 3 seconds between steps. Step accuracy was scored independently by 3 examiners. RESULTS Immediately after landing subjects seemed to be unaware of their foot position relative to their body or the floor. The percentage of correct steps was significantly decreased on landing day. Partial recovery was observed the next day, and full recovery to baseline on the sixth day post landing. CONCLUSION These data clearly demonstrate the sensorimotor challenges facing crewmembers after they return from space flight. Although this simple test is intended to complement the FTT battery of tests, it has some stand-alone value as it provides investigators with a means to quantify vestibular ataxia as well as provide instant feedback on postural stability without the use of complex test equipment.

Fisher, E. A.↗

Attentional Modulation of Eye Torsion Responses

Eye movements generally have both reflexive and voluntary aspects, but torsional eye movements are usually thought of as a reflexive response to image rotation around the line of sight (torsional OKN) or to head roll (torsional VOR). In this study we asked whether torsional responses could be modulated by attention in a case where two stimuli rotated independently, and whether attention would influence the latency of responses. The display consisted of rear-projected radial "pinwheel" gratings, with an inner annulus segment extending from the center to 22 degrees eccentricity, and an outer annulus segment extending from 22 degrees out to 45 degrees eccentricity. The two segments rotated around the center in independent random walks, stepping randomly 4 degrees clockwise or counterclockwise at 60 Hz. Subjects were asked to attend to one or the other while keeping fixation steady at the center of the display. To encourage attention on one or the other segment of the display, subjects were asked to move a joystick in synchrony with the back and forth rotations of one part of the image while ignoring the other. Eye torsion was recorded with the scleral search coil technique, sampled at 500 Hz. All four subjects showed roughly 50% stronger torsion responses to the attended compared to unattended segments. Latency varied from 100 to 150 msec across subjects and was unchanged by attention. These findings suggest that attention can influence eye movement responses that are not typically under voluntary control.

attention↗

Attentional Modulation of Eye Torsion Responses

Eye movements generally have both reflexive and voluntary aspects, but torsional eye movements are usually thought of as a reflexive response to image rotation around the line of sight (torsional OKN) or to head roll (torsional VOR). In this study we asked whether torsional responses could be modulated by attention in a case where two stimuli rotated independently, and whether attention would influence the latency of responses. The display consisted of rear-projected radial pinwheel gratings, with an inner annulus segment extending from the center to 22 degrees eccentricity, and an outer annulus segment extending from 22 degrees out to 45 degrees eccentricity. The two segments rotated around the center in independent random walks, stepping randomly 4 degrees clockwise or counterclockwise at 60 Hz. Subjects were asked to attend to one or the other while keeping fixation steady at the center of the display. To encourage attention on one or the other segment of the display, subjects were asked to move a joystick in synchrony with the back and forth rotations of one part of the image while ignoring the other. Eye torsion was recorded with the scleral search coil technique, sampled at 500 Hz. All four subjects showed roughly 50 stronger torsion responses to the attended compared to unattended segments. Latency varied from 100 to 150 msec across subjects and was unchanged by attention. These findings suggest that attention can influence eye movement responses that are not typically under voluntary control.

ocular torsion↗

ORNL Biometric Eye Model for Iris Recognition

Iris recognition has been proven to be an accurate and reliable biometric. However, the recognition of non-ideal iris images such as off angle images is still an unsolved problem. We propose a new biometric targeted eye model and a method to reconstruct the off-axis eye to its frontal view allowing for recognition using existing methods and algorithms. This allows for existing enterprise level algorithms and approaches to be largely unmodified by using our work as a pre-processor to improve performance. In addition, we describe the `Limbus effect' and its importance for an accurate segmentation of off-axis irides. Our method uses an anatomically accurate human eye model and ray-tracing techniques to compute a transformation function, which reconstructs the iris to its frontal, non-refracted state. Then, the same eye model is used to render a frontal view of the reconstructed iris. The proposed method is fully described and results from synthetic data are shown to establish an upper limit on performance improvement and establish the importance of the proposed approach over traditional linear elliptical unwrapping methods. Our results with synthetic data demonstrate the ability to perform an accurate iris recognition with an image taken as much as 70 degrees off-axis.

Santos-Villalobos, Hector J↗

Investigating the Association of Eye Gaze Pattern and Diagnostic Error in Mammography

The objective of this study was to investigate the association between eye-gaze patterns and the diagnostic accuracy of radiologists for the task of assessing the likelihood of malignancy of mammographic masses. Six radiologists (2 expert breast imagers and 4 Radiology residents of variable training) assessed the likelihood of malignancy of 40 biopsy-proven mammographic masses (20 malignant and 20 benign) on a computer monitor. Eye-gaze data were collected using a commercial remote eye-tracker. Upon reviewing each mass, the radiologists were also asked to provide their assessment regarding the probability of malignancy of the depicted mass as well as a rating regarding the perceived difficulty of the diagnostic task. The collected data were analyzed using established algorithms and various quantitative metrics were extracted to characterize the recorded gaze patterns. The extracted metrics were correlated with the radiologists diagnostic decisions and perceived complexity scores. Results showed that the visual gaze pattern of radiologists varies substantially, not only depending on their experience level but also among individuals. However, some eye gaze metrics appear to correlate with diagnostic error and perceived complexity more consistently. These results suggest that although gaze patterns are generally associated with diagnostic error and the human perceived difficulty of the diagnostic task, there are substantially individual differences that are not explained simply by the experience level of the individual performing the diagnostic task.

Voisin, Sophie↗

Gaze Estimation for Off-Angle Iris Recognition Based on the Biometric Eye Model

Iris recognition is among the highest accuracy biometrics. However, its accuracy relies on controlled high quality capture data and is negatively affected by several factors such as angle, occlusion, and dilation. Non-ideal iris recognition is a new research focus in biometrics. In this paper, we present a gaze estimation method designed for use in an off-angle iris recognition framework based on the ANONYMIZED biometric eye model. Gaze estimation is an important prerequisite step to correct an off-angle iris images. To achieve the accurate frontal reconstruction of an off-angle iris image, we first need to estimate the eye gaze direction from elliptical features of an iris image. Typically additional information such as well-controlled light sources, head mounted equipment, and multiple cameras are not available. Our approach utilizes only the iris and pupil boundary segmentation allowing it to be applicable to all iris capture hardware. We compare the boundaries with a look-up-table generated by using our biologically inspired biometric eye model and find the closest feature point in the look-up-table to estimate the gaze. Based on the results from real images, the proposed method shows effectiveness in gaze estimation accuracy for our biometric eye model with an average error of approximately 3.5 degrees over a 50 degree range.

Karakaya, Mahmut↗

Measuring Human Performance in Simulated Nuclear Power Plant Control Rooms Using Eye Tracking

Control room modernization will be an important part of life extension for the existing light water reactor fleet. As part of modernization efforts, personnel will need to gain a full understanding of how control room technologies affect performance of human operators. Recent advances in technology enables the use of eye tracking technology to continuously measure an operator’s eye movement, which correlates with a variety of human performance constructs such as situation awareness and workload. This report describes eye tracking metrics in the context of how they will be used in nuclear power plant control room simulator studies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Absorption of wireless radiation in the child versus adult brain and eye from cell phone conversation or virtual reality

Highlights: • More cell phone radiation is absorbed by children's inner brain tissues than adults’. • Children's radiofrequency radiation exposure should be reduced. • Further research to evaluate the risks to the eye from use of VR is urgently needed. • It is biologically relevant and feasible to reduce the standards’ averaging volume. • Current methods to determine wireless device compliance should be revised. Children's brains are more susceptible to hazardous exposures, and are thought to absorb higher doses of radiation from cell phones in some regions of the brain. Globally the numbers and applications of wireless devices are increasing rapidly, but since 1997 safety testing has relied on a large, homogenous, adult male head phantom to simulate exposures; the “Standard Anthropomorphic Mannequin” (SAM) is used to estimate only whether tissue temperature will be increased by more than 1 Celsius degree in the periphery. The present work employs anatomically based modeling currently used to set standards for surgical and medical devices, that incorporates heterogeneous characteristics of age and anatomy. Modeling of a cell phone held to the ear, or of virtual reality devices in front of the eyes, reveals that young eyes and brains absorb substantially higher local radiation doses than adults’. Age-specific simulations indicate the need to apply refined methods for regulatory compliance testing; and for public education regarding manufacturers' advice to keep phones off the body, and prudent use to limit exposures, particularly to protect the young.

54 ENVIRONMENTAL SCIENCES↗

Cortexin diffusion in human eye sclera

Investigation of the diffusion of cytamines, a typical representative of which is cortexin, is important for evaluating the drug dose, necessary to provide sufficient concentration of the preparation in the inner tissues of the eye. In the present paper, the cortexin diffusion rate in the eye sclera is measured using the methods of optical coherence tomography (OCT) and reflectance spectroscopy. The technique for determining the diffusion coefficient is based on the registration of temporal dependence of the eye sclera scattering parameters caused by partial replacement of interstitial fluid with the aqueous cortexin solution, which reduces the level of the OCT signal and decreases the reflectance of the sclera. The values of the cortexin diffusion coefficient obtained using two independent optical methods are in good agreement. (optical technologies in biophysics and medicine)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of laser UV radiation on the eye scleral tissue in patients with open-angle glaucoma

We report the results of an experimental study of the effect of short-pulse laser UV radiation on the eye scleral tissue. As samples, we used isolated flaps of the eye scleral tissue from the patients with open-angle glaucoma of the second and third stages. The impact was implemented using the radiation of an excimer XeCl laser with a wavelength of 308 nm and a laser with a wavelength tunable within from 210 to 355 nm. Depending on the problem to be solved, the energy density on the surface of the irradiated tissue varied from a fraction of mJ cm{sup –2} to 15 J cm{sup –2}. For the first time we studied the optical properties of the intraocular fluid in the UV and blue spectral range. The study of the ablation process under the action of radiation with a wavelength of 308 nm showed that the rate of material evaporation can vary within 24 % – 30 % at an energy density above 7 J cm{sup –2}, depending on the glaucoma stage and the individual features of a patient. The excitation – emission matrices of laser-induced fluorescence (LIF) of the eye scleral tissue were studied experimentally using a laser with a wavelength tuned in the range 210 – 355 nm. We found the differences in the LIF spectra caused by the excitation wavelength and the open-angle glaucoma stage. (laser medicine)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-635: Process Mapping of Eye Plaque Brachytherapy

Purpose: To apply a risk-based assessment and analysis technique (AAPM TG 100) to eye plaque brachytherapy treatment of ocular melanoma. Methods: The role and responsibility of personnel involved in the eye plaque brachytherapy is defined for retinal specialist, radiation oncologist, nurse and medical physicist. The entire procedure was examined carefully. First, major processes were identified and then details for each major process were followed. Results: Seventy-one total potential modes were identified. Eight major processes (corresponding detailed number of modes) are patient consultation (2 modes), pretreatment tumor localization (11), treatment planning (13), seed ordering and calibration (10), eye plaque assembly (10), implantation (11), removal (11), and deconstruction (3), respectively. Half of the total modes (36 modes) are related to physicist while physicist is not involved in processes such as during the actual procedure of suturing and removing the plaque. Conclusion: Not only can failure modes arise from physicist-related procedures such as treatment planning and source activity calibration, but it can also exist in more clinical procedures by other medical staff. The improvement of the accurate communication for non-physicist-related clinical procedures could potentially be an approach to prevent human errors. More rigorous physics double check would reduce the error for physicist-related procedures. Eventually, based on this detailed process map, failure mode and effect analysis (FMEA) will identify top tiers of modes by ranking all possible modes with risk priority number (RPN). For those high risk modes, fault tree analysis (FTA) will provide possible preventive action plans.

61 RADIATION PROTECTION AND DOSIMETRY↗