Analysis of high vacuum systems using SINDA'85

The theory, algorithms, and test data correlation analysis of a math model developed to predict performance of the Space Station Freedom Vacuum Exhaust System are presented. The theory used to predict the flow characteristics of viscous, transition, and molecular flow is presented in detail. Development of user subroutines which predict the flow characteristics in conjunction with the SINDA'85/FLUINT analysis software are discussed. The resistance-capacitance network approach with application to vacuum system analysis is demonstrated and results from the model are correlated with test data. The model was developed to predict the performance of the Space Station Freedom Vacuum Exhaust System. However, the unique use of the user subroutines developed in this model and written into the SINDA'85/FLUINT thermal analysis model provides a powerful tool that can be used to predict the transient performance of vacuum systems and gas flow in tubes of virtually any geometry. This can be accomplished using a resistance-capacitance (R-C) method very similar to the methods used to perform thermal analyses.

Spivey, R. A.↗

Shuttle primary reaction control system engine exhaust plume contamination effects

Space Shuttle proximity operations constitute an important part of the SSF induced external environment. The impingement of primary reaction control system (PRCS) engine plumes on SSF functional surfaces during docking or berthing and separation leads to concerns about molecular contamination and high speed particle impact. The Shuttle Plume Impingement flight Experiment (SPIE) was designed to provide a direct measure of both the molecular contamination and particle impact rates produced by Shuttle PRCS engines in the LEO environment. The measured permanent deposition produced by PRCS engine firings was less than that assumed in current SSF programatic assessments. Only two to three possible high velocity particle impact pits were observed on the RMS end effector hardware.

Koontz, Steve↗

Evaluation of fuel-borne sodium effects on a DOC-DPF-SCR heavy-duty engine emission control system: Simulation of full-useful life

Here we report that for renewable fuels to displace petroleum, they must be compatible with emissions control devices. Pure biodiesel contains up to 5 ppm Na + K and 5 ppm Ca + Mg metals, which have the potential to degrade diesel emissions control systems. This study aims to address these concerns, identify deactivation mechanisms, and determine if a lower limit is needed. Accelerated aging of a production exhaust system was conducted on an engine test stand over 1001 h using 20% biodiesel blended into ultra-low sulfur diesel (B20) doped with 14 ppm Na. This Na level is equivalent to exposure to Na at the uppermost expected B100 value in a B20 blend for the system full-useful life. During the study, NOx emissions exceeded the engine certification limit of 0.33 g/bhp-hr before the 435,000-mile requirement. Replacing aged diesel oxidation catalyst (DOC), diesel particulate filter (DPF), and selective catalytic reduction (SCR) devices with new degreened parts showed that each device contributed equally to the NOx increase. Following this systems-based evaluation, a detailed investigation of the individual components was completed. Na was determined to have minimal impact on DOC activity. For this system, it is estimated that B20-Na resulted in 50% more ash into the DPF. However, the Na did not diffuse into the cordierite DPF nor degrade its mechanical properties. The SCR degradation was found to be caused by a small amount of precious group metals (PGM) contamination that increased NH3 oxidation, and lowered NOx reduction. Therefore, we determined that the primary effect of Na in this study is through increased ash in the DPF rather than deactivation of the catalytic activity.

42 ENGINEERING↗

Removing Welding Fumes

Portable exhaust duct for machining and welding shops removes oil mist, dust, smoke, and fumes. Duct used with shop exhaust system, inlets of which placed at various convenient locations in shop floor. Flanged connector on underside of wheeled base links flexible tube to exhaust system under floor. Made especially for welding in room with low ceiling.

Moore, Lloyd J.↗

RCM and application at Sandia National Labs.

Reliability-Centered Maintenance (RCM) is a process used to determine what must be done to ensure that any physical asset continues to do whatever its users want it to do in its present operating context. There are 7 basic questions of RCM: (1) what are the functions of the asset; (2) in hwat ways does it fail to fulfill its functions; (3) what causes each functional failure; (4) what happens when each failure occurs; (5) in what way does each failure matter; (6) what can be done to predict or prevent each failure; and (7) what should be done if a suitable proactive task cannot be found. SNL's RCM experiences: (1) acid exhaust system - (a) reduced risk of system failure (safety and operational consequences), (b) reduced annual correctiv maintenance hours from 138 in FY06 to zero in FY07, FY08, FY09, FY10 and FY11 so far, (c) identified single point of failure, mitigated risk, and recommended a permanent solution; (2) fire alarm system - (a) reduced false alarms, which cause costly evacuations, (b) precented 1- to 2-day evacuation by identifying and obtaining a critical spare for a network card; (3) heating water system - (a) reduced PM hours on fire-tube boilers by 60%, (b) developed operator tasks and PM plan for modular boilers, which can be applied to many installations; and (4) GIF source elevator system - (a) reduced frequency of PM tasks from 6 months to 1 year, (b) established predictive maintenance task that identified overheating cabinet and prevented potential electrical failure or fire.

99 GENERAL AND MISCELLANEOUS↗

Analysis of Multiengine Transport Airplane Fire Records

An analysis has been made of Civil Aeronautics Administration and Civil Aeronautics Board commercial airplane fire records collected during the 10-year period ending July 1, 1948. The results of the analysis show that: 1. Gasoline was most frequently the initial combustible ignited in flight and ground fires and is considered to be the most hazardous of the combustibles carried. 2. Although electrical-ignition sources are the most frequent flight-fire ignition source by a small margin, the exhaust system is concluded to be the most hazardous ignition source because it is necessarily located near the lubricating-oil and gasoline-plumbing systems and the resulting fires are relatively severe. The electrical-ignition sources usually involve only the electrical insulation and result in small-volume fires. The exhaust system was found to be the most frequent ground-fire ignition source. 3. Engine failures were the most frequent cause of the union of combustible and ignition source that resulted in flight fires. 4. Fuel-plumbing-system failures were the most frequent cause of fires occurring during ground operation. 5. The evidence concerning crash fires was not sufficiently extensive to provide information concerning the factors that affect the start and the spread of fire. In order that future records may be more useful, all crash accidents should be studied to determine why fire does or does not occur and to establish data that relate the occurrence and the spread of fire to airplane design and operation.

Pesman, Gerard J.↗

Exhaust gas heat recovery system

A powertrain includes an engine, an exhaust system including an exhaust passageway in fluid communication with the engine, an exhaust gas heat exchanger, a transmission having a transmission cooling system, a transmission heat exchanger, a heater core, a pump, and an engine coolant circuit. The engine coolant circuit provides fluid communication between the engine, the exhaust gas heat exchanger, the transmission heat exchanger, the heater core, and the pump. The exhaust gas heat exchanger is operatively connected to the exhaust system and configured to transfer heat between the engine coolant circuit and the exhaust system. The transmission heat exchanger is operatively connected to the transmission cooling system and configured to transfer heat between the engine coolant circuit and the transmission cooling system.

33 ADVANCED PROPULSION SYSTEMS↗

Separate Flow Nozzle Test Status Meeting

NASA Glenn, in partnership with US industry, completed an exhaustive experimental study on jet noise reduction from separate flow nozzle exhaust systems. The study developed a data base on various bypass ratio nozzles, screened quietest configurations and acquired pertinent data for predicting the plume behavior and ultimately its corresponding jet noise. Several exhaust system configurations provided over 2.5 EPNdB jet noise reduction at take-off power. These data were disseminated to US aerospace industry in a conference hosted by NASA GRC whose proceedings are shown in this report.

Saiyed, Naseem H.↗

Static Aerodynamic Performance Investigation of a Fluid Shield Nozzle

In pursuit of an acoustically acceptable, high performance exhaust system capable of meeting Federal Aviation Regulation 36 Stage 3 noise goals for the High Speed Civil Transport application, General Electric Aircraft Engines conducted a design study to incorporate a fluid shield into a 36-chute suppressor exhaust-nozzle system. After a full scale preliminary mechanical design of the resulting fluid shield exhaust system, scale model aerodynamic performance tests and acoustic tests were conducted to establish both aerodynamic performance and acoustic characteristics. Data are presented as thrust coefficients, discharge coefficients, chute-base pressure drags, and plug static pressure distributions.

Balan, C.↗

Indoor Air Quality and Ventilation in Residential Deep Energy Retrofits

Because airtightening is a significant part of Deep Energy Retrofits (DERs), concerns about ventilation and Indoor Air Quality (IAQ) have emerged. To investigate this, ventilation and IAQ were assessed in 17 non-smoking California Deep Energy Retrofit homes. Inspections and surveys were used to assess household activities and ventilation systems. Pollutant sampling performed in 12 homes included six-day passive samples of nitrogen dioxide (NO 2 ), formaldehyde and air exchange rate (AER); time-resolved data loggers were used to measure particle counts. Half of the homes provided continuous mechanical ventilation. Despite these homes being twice as airtight (3.0 and 7.6 ACH50, respectively), their median AER was indistinguishable from naturally vented homes (0.36 versus 0.37 hr -1 ). Numerous problems were found with ventilation systems; however, pollutant levels did not reach levels of concern in most homes. Ambient NO 2 standards were exceeded in some gas cooking homes that used legacy ranges with standing pilots, and in Passive House-style homes without range hoods exhausted to outside. Cooking exhaust systems were installed and used inconsistently. The majority of homes reported using low-emitting materials, and formaldehyde levels were approximately half those in conventional new CA homes (19.7 versus 36 μg/m 3 ), with emissions rates nearly 40percent less (12.3 versus 20.6 μg/m 2 /hr.). Presence of air filtration systems led to lower indoor particle number concentrations (PN >0.5 : 8.80E+06 PN/m 3 versus 2.99E+06; PN >2.5 : 5.46E+0.5 PN/m 3 versus 2.59E+05). The results indicate that DERs can provide adequate ventilation and IAQ, and that DERs should prioritize source control, particle filtration and well-designed local exhaust systems, while still providing adequate continuous ventilation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Static Performance of Six Innovative Thrust Reverser Concepts for Subsonic Transport Applications: Summary of the NASA Langley Innovative Thrust Reverser Test Program

The NASA Langley Configuration Aerodynamics Branch has conducted an experimental investigation to study the static performance of innovative thrust reverser concepts applicable to high-bypass-ratio turbofan engines. Testing was conducted on a conventional separate-flow exhaust system configuration, a conventional cascade thrust reverser configuration, and six innovative thrust reverser configurations. The innovative thrust reverser configurations consisted of a cascade thrust reverser with porous fan-duct blocker, a blockerless thrust reverser, two core-mounted target thrust reversers, a multi-door crocodile thrust reverser, and a wing-mounted thrust reverser. Each of the innovative thrust reverser concepts offer potential weight savings and/or design simplifications over a conventional cascade thrust reverser design. Testing was conducted in the Jet-Exit Test Facility at NASA Langley Research Center using a 7.9%-scale exhaust system model with a fan-to-core bypass ratio of approximately 9.0. All tests were conducted with no external flow and cold, high-pressure air was used to simulate core and fan exhaust flows. Results show that the innovative thrust reverser concepts achieved thrust reverser performance levels which, when taking into account the potential for system simplification and reduced weight, may make them competitive with, or potentially more cost effective than current state-of-the-art thrust reverser systems.

Asbury, Scott C.↗

Static Performance of Six Innovative Thrust Reverser Concepts for Subsonic Transport Applications: Summary of the NASA Langley Innovative Thrust Reverser Test Program

The NASA Langley Configuration Aerodynamics Branch has conducted an experimental investigation to study the static performance of innovative thrust reverser concepts applicable to high-bypass-ratio turbofan engines. Testing was conducted on a conventional separate-flow exhaust system configuration, a conventional cascade thrust reverser configuration, and six innovative thrust reverser configurations. The innovative thrust reverser configurations consisted of a cascade thrust reverser with porous fan-duct blocker, a blockerless thrust reverser, two core-mounted target thrust reversers, a multi-door crocodile thrust reverser, and a wing-mounted thrust reverser. Each of the innovative thrust reverser concepts offer potential weight savings and/or design simplifications over a conventional cascade thrust reverser design. Testing was conducted in the Jet-Exit Test Facility at NASA Langley Research Center using a 7.9%-scale exhaust system model with a fan-to-core bypass ratio of approximately 9.0. All tests were conducted with no external flow and cold, high-pressure air was used to simulate core and fan exhaust flows. Results show that the innovative thrust reverser concepts achieved thrust reverser performance levels which, when taking into account the potential for system simplification and reduced weight, may make them competitive with, or potentially more cost effective than current state-of-the-art thrust reverser systems. All data gathered in this investigation are contained in the CD-ROM.

Asbury, Scott C.↗

Design predictions for noise control in the cryogenic National Transonic Facility

Noise control in the National Transonic Facility - a cryogenic wind tunnel - has been examined in terms of acoustical design criteria, drive-fan noise and exhaust system noise. A duct lining with two layers of perforated sheeting and a gas-filled honeycomb core was selected for attenuating drive-fan noise. With the exception of attenuation peaks, attenuation of the lining was found to experimentally agree with predicted values at 20 C air temperatures. Exhaust system noise will be attenuated with a large muffler used in conjunction with a 6.1-m high acoustical enclosure. Fan noise from the fan-ejector system will be attenuated by fan silencers and the acoustic enclosure.

Lassiter, W. S.↗

Experimental evaluation of exhaust mixers for an Energy Efficient Engine

Static scale model tests were conducted to evaluate exhaust system mixers for a high bypass ratio engine as part of the NASA sponsored Energy Efficient program. Gross thrust coefficients were measured for a series of mixer configurations which included variations in the number of mixer lobes, tailpipe length, mixer penetration, and length. All of these parameters have a significant impact on exhaust system performance. In addition, flow visualization pictures and pressure/temperature traverses were obtained for selected configurations. Parametric performance trends are discussed and the results considered relative to the Energy Efficient Engine program goals.

Kozlowski, H.↗

Broadband Shock Noise in Internally-Mixed Dual-Stream Jets

Broadband shock noise (BBSN) has been studied in some detail in single-flow jets and recently in dual-stream jets with separate flow exhaust systems. Shock noise is of great concern in these latter cases because of the noise created for the aircraft cabin by the underexpanded nozzle flow at cruise. Another case where shock noise is of concern is in the case of future supersonic aircraft that are expected to have bypass ratios small enough to justify internally mixed exhaust systems, and whose mission will push cycles to the point of imperfectly expanded flows. Dual-stream jets with internally mixed plume have some simplifying aspects relative to the separate flow jets, having a single shock structure given by the common nozzle pressure. This is used to separate the contribution of the turbulent shear layer to the broadband shock noise. Shock structure is held constant while the geometry and strength of the inner and merged shear layers are varying by changing splitter area ratio and core stream temperature. Flow and noise measurements are presented which document the efforts at separating the contribution of the inner shear layer to the broadband shock noise.

Bridges, James E.↗

Ambient Air Sampling During Quantum-dot Spray Deposition

Ambient air sampling for nano-size particle emissions was performed during spot spray coating operations with a Sono-Tek Exactacoat Benchtop system (ECB). The ECB consisted of the application equipment contained within an exhaust enclosure. The enclosure contained numerous small access openings, including an exhaust hook-up. Door access comprised most of the width and height of the front. The door itself was of the swing-out type. Two types of nanomaterials, Cadmium selenide (Cd-Se) quantum-dots (QDs) and Gold (Au) QDs, nominally 3.3 and 5 nm in diameter respectively, were applied during the evaluation. Median spray drop size was in the 20 to 60 micrometer size range.1 Surface coating tests were of short duration, on the order of one-half second per spray and ten spray applications between door openings. The enclosure was ventilated by connection to a high efficiency particulate aerosol (HEPA) filtered house exhaust system. The exhaust rate was nominally 80 ft3 per minute producing about 5 air changes per minute. Real time air monitoring with a scanning mobility particle size analyzer (SMPS ) with a size detection limit of 7 nm indicated a significant increase in the ambient air concentration upon early door opening. A handheld condensation particle counter (CPC) with a lower size limit of 10 nm did not record changes in the ambient background. This increase in the ambient was not observed when door opening was delayed for 2 minutes (~10 air changes). The ventilated enclosure controlled emissions except for cases of rapid door opening before the overspray could be removed by the exhaust. A time delay sufficient to provide 10 enclosure air changes (a concentration reduction of more than 99.99 %) before door opening prevented the release of aerosol particles in any size.2 Scanning-transmission electron microscopy (STEM) and atomic force microscopy (AFM) demonstrated the presence of agglomerates in the surfaces of the spray applied deposition. A filtered air sample of the enclosure overspray examined by AFM also demonstrated the presence of agglomerates for the Au QDs. The AFM system was not able to resolve individual QDs as was the STEM. Chemical fingerprinting of the QDs with STEM/EDS (energy dispersive spectroscopy) was performed for the Cd-Se surface deposition, but not the aerosol. Both STEM and AFM background characterization by morphology and chemical fingerprinting were performed throughout the laboratory for a period of about one year. Outdoor sources were primarily biological, combustion fume, salt and other crustal particles. Indoor sources were primarily paper/clothing fibers, spray-on insulation fragments, fiber glass, and human skin cells.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High temperature UF6 RF plasma experiments applicable to uranium plasma core reactors

An investigation was conducted using a 1.2 MW RF induction heater facility to aid in developing the technology necessary for designing a self critical fissioning uranium plasma core reactor. Pure, high temperature uranium hexafluoride (UF6) was injected into an argon fluid mechanically confined, steady state, RF heated plasma while employing different exhaust systems and diagnostic techniques to simulate and investigate some potential characteristics of uranium plasma core nuclear reactors. The development of techniques and equipment for fluid mechanical confinement of RF heated uranium plasmas with a high density of uranium vapor within the plasma, while simultaneously minimizing deposition of uranium and uranium compounds on the test chamber peripheral wall, endwall surfaces, and primary exhaust ducts, is discussed. The material tests and handling techniques suitable for use with high temperature, high pressure, gaseous UF6 are described and the development of complementary diagnostic instrumentation and measurement techniques to characterize the uranium plasma, effluent exhaust gases, and residue deposited on the test chamber and exhaust system components is reported.