Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EVACUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

New shield for gamma-ray spectrometry

Gamma-ray shield that can be evacuated, refilled with a clean gas, and pressurized for exclusion of airborne radioactive contaminants effectively lowers background noise. Under working conditions, repeated evacuation and filling procedures have not adversely affected the sensitivity and resolution of the crystal detector.

Brar, S. S.↗

Nondestructive leak testing

Method provides opportunity to effect repairs without compromising integrity of enclosed circuitry or mechanism by loss of atmosphere or by ingestion of foreign matter or gas. It is possible to detect leaks in modules which are sealed while fully evacuated, partially evacuated, or containing some form of gas.

Lusby, T. K., Jr.↗

Thermal performance of multilayer insulations

Experimental and analytical studies were conducted in order to extend previous knowledge of the thermal performance and gas evacuation characteristics of three selected multilayer insulation (MLI) composites. Flat plate calorimeter heat flux measurements were obtained for 20- and 80- shield specimens using three representative layer densities over boundary temperatures ranging from 39 K (70 R) to 389 K (700 R). Laboratory gas evacuation tests were performed on representative specimens of each MLI composite after initially purging them with helium, nitrogen, or argon gases. In these tests, the specimens were maintained at temperatures between 128 K (230 R) and 300 K (540 R). Based on the results of the laboratory-scale tests, a composite MLI system consisting of 112 unperforated, double-aluminized Mylar reflective shields and 113 water preconditioned silk net spacer pairs was fabricated and installed on a 1.22-m-(4-ft-) diameter calorimeter tank.

Keller, C. W.↗

Ultra sound absorption measurements in rock samples at low temperatures

A new technique, comparable with the reverberation method in room acoustics, is described. It allows Q-measurements at rock samples of arbitrary shape in the frequency range of 50 to 600 kHz in vacuum (.1 mtorr) and at low temperatures (+20 to -180 C). The method was developed in particular to investigate rock samples under lunar conditions. Ultrasound absorption has been measured at volcanics, breccia, gabbros, feldspar and quartz of different grain size and texture yielding the following results: evacuation raises Q mainly through lowering the humidity in the rock. In a dry compact rock, the effect of evacuation is small. With decreasing temperature, Q generally increases. Between +20 and -30 C, Q does not change much. With further decrease of temperature in many cases distinct anomalies appear, where Q becomes frequency dependent.

Herminghaus, C.↗

Soft X-ray lasers using distributed-feedback reflection: A concept

Proposed arrangement consists of large evacuated chamber containing smaller Dewar chamber into which liquid neon is introduced. Zeolite crystal is mounted in wall of chamber, with one side in contact with neon and other exposed to evacuated chamber. Electron gun is used to bombard crystal.

Grunthaner, F. J.↗

A fixed tilt solar collector employing reversible vee-trough reflectors and vacuum tube receivers for solar heating and cooling systems

The usefulness of vee-trough concentrators in improving the efficiency and reducing the cost of collectors assembled from evacuated tube receivers was studied in the vee-trough/vacuum tube collector (VTVTC) project. The VTVTC was analyzed rigorously and various mathematical models were developed to calculate the optical performance of the vee-trough concentrator and the thermal performance of the evacuated tube receiver. A test bed was constructed to verify the mathematical analyses and compare reflectors made out of glass, Alzak and aluminized FEP Teflon. Tests were run at temperatures ranging from 95 to 180 C. Vee-trough collector efficiencies of 35 to 40% were observed at an operating temperature of about 175 C. Test results compared well with the calculated values. Predicted daily useful heat collection and efficiency values are presented for a year's duration of operation temperatures ranging from 65 to 230 C. Estimated collector costs and resulting thermal energy costs are presented. Analytical and experimental results are discussed along with a complete economic evaluation.

Selcuk, M. K.↗

Thermostructural analysis of three structural concepts for reusable space vehicles

Three structural concepts are studied: (1) a state-of-the-art insulated aluminum skin-stringer structure; (2) a near-art insulated evacuated aluminum-alloy honeycomb structure; and (3) an advanced evacuated Rene 41 honeycomb hot structure. Each is evaluated for its thermostructural performance for each of the flight profiles (ascent, entry, and a recall or abort). Results indicate that (1) the state-of-the-art structure encounters negligible thermal stress; (2) the near-art structure has acceptable thermal stresses; and (3) the advanced structure will have thermal stress levels above the material allowables.

Taylor, A. H.↗

Analysis, development and testing of a fixed tilt solar collector employing reversible Vee-Trough reflectors and vacuum tube receivers

The Vee-Trough/Vacuum Tube Collector (VTVTC) aimed to improve the efficiency and reduce the cost of collectors assembled from evacuated tube receivers. The VTVTC was analyzed rigorously and a mathematical model was developed to calculate the optical performance of the vee-trough concentrator and the thermal performance of the evacuated tube receiver. A test bed was constructed to verify the mathematical analyses and compare reflectors made out of glass, Alzak and aluminized GEB Teflon. Tests were run at temperatures ranging from 95 to 180 C during the months of April, May, June, July and August 1977. Vee-trough collector efficiencies of 35-40 per cent were observed at an operating temperature of about 175 C. Test results compared well with the calculated values. Test data covering a complete day are presented for selected dates throughout the test season. Predicted daily useful heat collection and efficiency values are presented for a year's duration at operation temperatures ranging from 65 to 230 C. Estimated collector costs and resulting thermal energy costs are presented. Analytical and experimental results are discussed along with an economic evaluation.

Selcuk, M. K.↗

Decrease of keV electron and ion fluxes in the dayside magnetosphere during the early phase of magnetospheric disturbances

It is shown that a decrease of the keV particle fluxes in the dayside magnetosphere near the geosynchronous orbit is characteristic of the first several hours of magnetospheric disturbances. After some hours newly injected plasma from the nightside reaches the 'evacuated' regions of the dayside magnetosphere and strong flux increases are observed. The 'evacuation' of the dayside magnetosphere is interpreted in terms of a change in the convection pattern associated with an increase of the large scale electric field at the onset of the disturbance. The model presented is capable of accommodating all characteristics of the observational data, such as the temporal and spatial distributions, energy and pitch angle characteristics, and differences between electrons and protons.

Hultqvist, B.↗

Precise Sealing of Fused-Quartz Ampoules

New technique rapidly evacuates and seals fused-quartz ampoule with precise clearance over contents without appreciably thinning ampoule walls. Quartz plug is lowered into working section of ampoule after ampoule has been evacuated. Plug is then fused to ampoule walls, forming vacuum seal. New technique maintains wall strength and pumping speed.

Debnan, W. J. J.↗

Study of multiple optical transitions in 87Rb using laser diodes

Recent work with laser diodes has indicated their potential usefulness in optically pumping atomic frequency standards. Various optical pumping schemes for (87)Rb incorporating such light sources at two D1 frequencies for experimental situations of either evacuated wall-coated cells or atomic beams are considered. Numerical integration of rate equations governing the level populations with arbitrary pumping light choices of intensity, D1 hyperfine transition(s), and polarization and subsequent calculation of scattered light provide a simplified 0-0 hyperfine signal analysis. By frequency modulating one laser diode, two optical transitions were excited in an evacuated wall-coated cell and a large delta m(F) = 1 hf signal was observed.

Newton, C. L. J.↗

A new concept for exhaust diffusers of altitude test cells

A new exhaust diffuser concept for jet engine altitude test cells which greatly reduces operating power and cost requirements for exhausters is discussed. The concept utilizes the capture duct as an efficient diffuser only, while evacuating the secondary air via a separate path using an auxiliary suction system. Implementation of the concept would reduce the peak exhauster power requirement during a TF-30 altitude test by 48 percent and the overall exhaust power cost of the test program by 41 percent. The design accommodates various engine sizes and can achieve optimum pressure recovery performance during both A/B and IRP modes of engine operation. The pressure recovery performance of the proposed exhaust diffusers does not deteriorate with increasing cooling air fraction. The disadvantages of the proposed scheme are: increased mechanical complexity of the extended variable geometry diffuser duct and the need for an auxiliary suction system for evacuating cell-cooling air.

Parikh, P. G.↗

Bench cooling the Thematic Mapper

The present investigation is concerned with the bench cooling system which was developed in conjunction with the Thematic Mapper (TM), a second-generation earth resources sensor. A small, permanently evacuated dewar, which is carried into space with the instrument, is employed to provide thermal isolation for bench cooling IR detectors of many space-borne instruments. This approach has, however, a number of disadvantages. The system designed for cooling the TM makes, therefore, use of a new approach, involving a temporarily evacuated, take-apart dewar in combination with a temperature-controlled Joule-Thomson cryostat.

Kuyper, D. J.↗

Improvement in the quality of flow visualization in the Langley 0.3-meter transonic cryogenic tunnel

Optical diagnostic techniques have not been as successful in the 0.3-Meter Transonic Cryogenic Tunnel as in conventional wind tunnels. This paper describes a simple shadowgraph experiment which allowed evacuation of the optical paths outside the test section. The results show that refractive index variations induced by temperature gradients outside the test section account for most of the image degradation. Earlier reports had erroneously attributed this degradation to inhomogeneities in the test section. Evacuation of the paths leading to and from the test section significantly improves the quality of flow visualization.

Snow, W. L.↗

Convection zone origins of solar atmospheric heating

Spicules are examined as a means for supplying the corona with mass, energy, and magnetic field. It is suggested that spicules form from the supersonic upward expansion of material on nearly evacuated network flux tubes embedded within the sun's convection zone. This allows supersonic but subescape velocities to be attained by the material as it flows outward through the photosphere. Although supersonic, the kinetic energy (subescape) of the spicule material, as observed, is insufficient for coronal heating. It is suggested that, through buoyancy changes on evacuated flux tubes, the magnetic field first 'wicks' material flow into the solar atmosphere. Subsequently, the magnetic field energizes the gaseous material to form the conventional hot, dynamically expanding, solar corona. This occurs through momentum and energy transport by Alfven waves and associated Maxwell stresses concurrently flowing upward on these 'geysers' (spicules). The vertical momentum equation governing fluid flow is examined, and a particular equipartition solution is presented for the flow velocity along a simple field geometry.

Schatten, Kenneth H.↗

Biomedical program at Space Biospheres Ventures

There are many similarities and some important differences between potential health problems of Biosphere 2 and those of which might be anticipated for a space station or a major outpost on Mars. The demands of time, expense, and equipment would not readily allow medical evacuation from deep space for a serious illness or major trauma, whereas personnel can easily be evacuated from Biosphere 2 if necessary. Treatment facilities can be somewhat less inclusive, since distance would not compel the undertaking of heroic measures or highly complicated surgical procedures on site, and with personnel not fully trained for these procedures. The similarities are given between medical requirements of Biosphere 2 and the complex closed ecological systems of biospheres in space or on Mars. The major problems common to all these would seem to be trauma, infection, and toxicity. It is planned that minor and moderate degrees of trauma, including debridement and suturing of wounds, x ray study of fractures, will be done within Biosphere 2. Bacteriologic and fungal infections, and possibly allergies to pollen or spores are expected to be the commonest medical problem within Biosphere 2.

Walford, Roy↗

Optical testing cryogenic thermal vacuum facility

The construction of a turnkey cryogenic vacuum test facility was recently completed. The facility will be used to measure and record the surface profile of large diameter and 540 kg optics under simulated space conditions. The vacuum test chamber is a vertical stainless steel cylinder with a 3.5 diameter and a 7 m tangent length. The chamber was designed to maximize optical testing quality by minimizing the vibrations between the laser interferometer and the test specimen. This was accomplished by designing the chamber for a high natural frequency and vibration isolating the chamber. An optical test specimen is mounted on a movable presentation stage. During thermal vacuum testing, the specimen may be positioned to + or - 0.00025 cm accuracy with a fine adjustment mechanism. The chamber is evacuated by a close coupled Roots-type blower and rotary vane pump package and two cryopumps. The chamber is equipped with an optically dense gaseous nitrogen cooled thermal shroud. The thermal shroud is used to cool or warm the optical test specimen at a controlled rate. A control system is provided to automatically evacuate the chamber and cooldown the test specimen to the selected control temperature.

Dohogne, Patrick W.↗

Nuclear winds in active elliptical galaxies. I - Interaction

The interaction of a supersonic wind generated by an active nucleus, a nuclear wind, with the hot interstellar medium of an elliptical host galaxy is investigated. We survey the basic time and spatial scales of this interaction through a study covering the range of probable wind and galaxy parameters. The evolving wind/ISM interaction is detailed, with the conclusion that a true equilibrium state is never possible due to long cooling times. Alteration of the wind by mass loading is considered, and a relationship between nuclear winds and central stellar clusters in this context is outlined. The nuclear wind will fundamentally alter the interstellar medium of the host galaxy. Powerful radio galaxies and quasars can evacuate the entire ISM of their host galaxy. In an isolated elliptical galaxy, winds from moderately powerful radio galaxies will either be confined to within about a kpc or evacuate the entire hot ISM. Even in the relatively high pressure ISM of elliptical galaxies winds containing only 1 percent-10 percent of the radiant luminosity of the active nucleus will extend to the narrow-line region. Therefore, nuclear winds are likely to control the properties of the narrow-line emission.

Smith, Steven J.↗