Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ESI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Cryogenic and Temperature-Dependent Photoelectron Spectroscopy of Metal Complexes

Negative ion photoelectron spectroscopy (NIPES) coupled with electrospray ionization (ESI) has been proved to be a powerful gas-phase spectroscopic tool for characterizing electronic structures and chemical bonding of a variety of cluster anions and corresponding neutral radicals involved in the condensed phase reactions and transformations. Since the acquisition of cryogenic and temperature-controlling capabilities, broader range of research scope has been covered. This review summarizes our recent investigations on metal complexes employing cryogenic ESI-NIPES that provide us essential information towards understanding complicated condensed phase reactions including hydrocarbon activations and electron transfer reactions, and afford us spectroscopic probe of highly reactive transient species and intimate redox pairs. Special attention has been drawn to connect gas phase photodetachment processes with solution phase redox reactions. Photodetachment of transition metal-EDTA complexes has been systematically investigated to model the sequential oxidation reactions of these species in solutions. The obtained gas phase electron affinity (EA) is compared with the solution redox potential (E1/2) and the metal ionization potential (IP) for several series of homologous metal complexes to emphasize their intrinsic correlations with deviations being largely modulated by different degrees of ligand participations.

Yuan, Qinqin↗

The Radiation Chemistry of CMPO: Part 2. Alpha Radiolysis

Here, Octylphenyl-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) dissolved in dodecane was subjected to α-irradiation using a He-ion beam, 244 Cm isotopic α-rays, and He and Li ions created by the n,α reaction of 10 B in a nuclear reactor. Post-irradiation samples were analyzed for the radiolytically-induced decrease in CMPO concentration, the appearance of degradation products, and their Am solvent extraction distribution ratios. The –G CMPO -value for the radiolytic degradation of CMPO was found to be very low compared to values previously reported for γ-irradiation. Additionally, isotopic irradiation to absorbed α-doses as high as 600 kGy in aerated solution had no effect on Am solvent extraction or stripping. The main CMPO radiolysis products identified in He-ion beam irradiated samples by ESI-MS include amides, an acidic amide, and amines produced by bond rupture on either side of the CMPO carbonyl group. Deaerated samples irradiated using the reactor in the absence of an aqueous phase, or with a dilute nitric acid aqueous phase showed small but measurable decreases in CMPO concentration with increasing absorbed doses. Higher concentrations of nitric acid resulted in lower decomposition rates for the CMPO. The radio-protection by dissolved oxygen and nitric acid previously found for γ-irradiated CMPO also occurs for α-irradiation. This suggests that similar free-radical mechanisms operate in the high-LET system, but with lower degradation yields due to the lower overall radical concentrations produced.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Unambiguous Metabolite Identification in High-Throughput Metabolomics by Hybrid 1H-NMR/ESI-MS1 Approach

The invention improves accuracy of metabolite identification by combining direct infusion ESI-MS with one-dimensional 1H-NMR spectroscopy. First, we apply a standard 1H-NMR metabolite identification protocol by matching the chemical shift, J-coupling and intensity information of experimental NMR signals against the NMR signals of standard metabolites in a metabolomics reference libraries. This generates a list of candidate metabolites. The list contains both false positive and ambiguous identifications. The software tool (the invention) takes the list of candidate metabolites, generated from NMRbased metabolite identification, and then calculates, for each of the candidate metabolites, the monoisotopic mass-tocharge (m/z) ratios for each commonly observed ion, fragment and adduct feature. These are then used to assign m/z ratios in experimental ESI-MS spectra of the same sample. Detection of the signals of a given metabolite in both NMR and MS spectra resolves the ambiguities, and therefore, significantly improves the confidence of the identification.

Source record↗

East River Surface and Pore Water FTICR-MS Data Associated with “Implications of sample treatment on characterization of the riverine environmental metabolome”

Surface and pore water samples were collected from distributed locations around Meander A in East River (Crested Butte, CO, USA) during the summer of 2018. This dataset consists of the characterization of dissolved organic matter using 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS; in .xml format) analyzed through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory) using two different sample pre-treatment methods (solid phase extraction, no solid phase extraction) and two electrospray ionization methods (ESI-positive, ESI-negative) to identify the impacts of these choices on the final dataset. This study aimed to understand how the different sample processing methods influence the resulting FTICR-MS dataset. Any published work that utilizes data presented in this dataset should cite the dataset using the DOI number. If using the dataset, please acknowledge the U.S. Department of Energy (DOE) Office of Science (BER) Subsurface Biogeochemical Research (SBR) program, the Environmental Molecular Sciences Laboratory (EMSL), and Worldwide Hydrobiogeochemical Observation Network for Dynamic River Systems (WHONDRS). The publication DOI will be added to this abstract when available.

54 ENVIRONMENTAL SCIENCES↗

Automated Clean Chemistry for Bulk Analysis of Environmental Swipe Samples – Final Report

Sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment to shorten lengthy and costly manual chemical purification procedures. This development addresses a serious need in the International Atomic Energy Agency’s (IAEA) Network of Analytical Laboratories (NWAL) to increase efficiency in the Bulk Analysis of Environmental Samples for Safeguards program with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc. (ESI), the prepFAST-MC2 was designed based on COTS equipment. It was modified for uranium/plutonium separations using renewable columns packed with Eichrom TEVA® and UTEVA® resins, with a chemical separation method based on the Oak Ridge National Laboratory (ORNL) NWAL chemical procedure. Initial verification of individual columns yielded small elution volumes with consistent elution profiles and good recovery. Combined column calibration demonstrated ample separation without crosscontamination of the eluent. Automated packing and unpacking of the built-in columns initially showed >15% deviation in resin loading by weight, which can lead to inconsistent separations. Optimization of the packing and unpacking methods led to a reduction in the variability of the packed resin to less than 5% daily. Based on the initial experience at ORNL with the prepFAST-MC2, a second-generation model, the prepFAST-SR, was built by ESI. The newly designed prepFAST-SR has several upgrades compared with the original prepFAST-MC2. The upgrades largely addressed issues with the reliability of unpacking the Eichrom columns and with ventilation to ensure adequate removal of acid vapors. Both systems are currently installed in the Ultra-Trace Forensics Science Center at ORNL. Separations of mixed uranium and plutonium samples containing certified reference materials were analyzed by multi-collector inductively coupled plasma mass spectrometry and yielded good results. Current efforts have demonstrated a wider applicability of the prepFAST system. Near-quantitative removal of metal interferences was achieved with the system in both uranium and plutonium separated fractions. Successful system validation was completed with several archived samples. Isotopic results from archived samples and certified reference materials were well within data quality limits for the IAEA NWAL. Additional COTS equipment has been evaluated for its potential to aid the prepFAST-SR system in reducing the time allotments and cleanroom infrastructure requirements for accurate separations. Overall, these efforts help ensure continued efficient and effective operation of the NWAL. Comparison of the amount of personnel time necessary for successful manual vs. automated chemical separations showed a significant decrease in hands-on time from 9.8 hours to 35 minutes for seven samples, respectively. This documented time savings and reduced labor translates to a significant cost savings per sample. Overall, the system will enable faster sample reporting times at reduced cost by limiting personnel hours dedicated to the chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

Ambient mass spectrometry is being investigated as a new method for rapidly characterizing trace inorganic species, including nuclear materials. SRNL is currently developing electrospray ionization (ESI) and paper spray ionization (PSI) methods for mass spectrometry for the detection of trace inorganic compounds JEOL AccuTOF™-DART ® LP 4G mass spectrometer. Sample analysis generates a complex three-dimensional data set with 10 2 -10 3 individual mass spectra spread temporally. To improve the quality and ease of data extraction from this amount of information, a simple data analysis pipeline written in R/R Studio has been improved and expanded upon. Specifically, the software now has header inputs to set base input/output filenames, isotopes of interest, and a list of concentrations analyzed on the instrument. Using list-based structures to enable batch processing of many concentrations at once, it then loads each file, extracts the relevant intensities for masses of interest from each spectrum, and iterates through each concentration to generate graphs of internal standard & analyte correlations, measured isotope ratios, and total ion chromatograms. It then filters the data to remove points at background levels or at the detector saturation limit. Using this filtered data, the pipeline re-creates the graphs to reveal high-quality information from a low-quality raw dataset. All graphs of the R software then output to PowerPoint format. Additionally, faster 3D visualization functionality was added to the pipeline for viewing the entire data file produced by the instrument as an intensity map. With these data analysis tools ready, samples of strontium nitrate/yttrium nitrate as an analyte/internal standard combination were measured on the AccuTOF. From the filtered data, calibration curves were prepared and limits of detection (LOD) of 1 ppb for ESI-MS and 20 ppb for PSI-MS were obtained. The quality available from the calibration curves and the low limits of detection demonstrate the value of the instrument/analysis pipeline system in characterizing trace inorganics.

47 OTHER INSTRUMENTATION↗

Collaborative Research: Natural Organic Matter and Microbial Controls on Mobilization/Immobilization of I and Pu in Soils and Waters Affected by Radionuclide Releases in USA and Japan

In this project, the relationship between natural organic matter (NOM) and two radioactive elements that are relevant to nuclear waste disposal were studied: Plutonium (Pu) and Iodine. The human and environmental risks associated with Pu stem mainly from the very long half-lives of several of its isotopes ( 238 Pu, 88 yr; 239 Pu, 24,100 yr; 240 Pu, 6560 yr) and its radiotoxicity. Understanding Pu biogeochemical behavior in both near-field (>10-11M) and far-field scales (<10-11M) is imperative to the development of approaches for reprocessing Pu, remediation of Pu contamination and accurate assessment of risks posed by disposal practices for Pu-bearing wastes. The environmental mobility of Pu can be affected by redox potential, pH, adsorption, precipitation, complexation, colloid formation, and microbial activity, of which the first characteristic has the most profound influence. Numerous studies have shown high affinity of Pu towards NOM, as well as to mineral phases. NOM is ubiquitous in the environment, e.g., both fulvic and humic acids are able to reduce Pu(V,VI) to Pu(IV) and the redox potential of NOM is positively related to the abundance of phenolic/acidic OH groups. NOM can either facilitate or limit actinide migration, depending on specific biogeochemical conditions including pH, mineral and organic matter characteristics, etc. The other radionuclide of interest is radioiodine ( 129 I). 129I is a major by-product of nuclear fission and of serious concern to the Department of Energy (DOE) as it is among the top risk drivers at existing and potential radiowaste-contaminated sites. The risk of 129 I stems largely from its high bioconcentration factor (90% of the body’s iodine is accumulated in the thyroid), a high inventory at source terms, a very long-half life (16M years), and rapid mobility in the subsurface environment. As a consequence, 129 I has the lowest drinking water standard (1 pCi/L) among all radionuclides in the Federal Register. With a novel and sensitive gas chromatography-mass spectrometry (GC-MS) method developed in our lab, it is possible to quickly and simultaneously determine the distribution of 129 I and stable 127 I forms in environments, as low as 2 pCi/L for 129 I. This method was subsequently validated using accelerator mass spectroscopy, AMS. IO 3 - and organo-I were determined as major species in the groundwater of SRS and the Hanford Site, contrary to thermodynamic predictions that I- should be the dominant species at these sites. Mobility of 129 I was also demonstrated to depend greatly on the I species and its concentration, sediment pH, and redox state, with times to achieve equilibrium taking up to 12 weeks. Along the groundwater pathway in the F-Area of SRS, 129 I- supplied from the seepage basins was transformed to 129 IO 3 - and organo- 129 I with increasing iodine sediment sorption, causing the lower total 127 I and 129 I concentrations along the gradient transect of the waste plume. By contrast, groundwater 129 I concentrations in the wetlands (as high as 1617.3 pCi/L) were greatly elevated with respect to the source term (159.3 pCi/L). While the NOM promoted the uptake of 129 I to the wetland sediment, it also promoted the formation of soluble organic fraction. A small fraction of NOM that is bound to iodine can behave as a mobile organo-I source. Iodide was enzymatically incorporated into NOM, whereas both iodide and iodate were abiotically bound to NOM, under certain conditions. Iodate removal from the mobile aqueous phase can also occur through incorporation into carbonate (e.g., at the Hanford Site, USA). Thus immobilization and re-mobilization of iodine species were influenced by pH, Eh and the presence of NOM and metal oxides, which adds to the complexity of site remediation action. A ground-breaking result was to elucidate the products (i.e. organo-iodine moieties formed via enzymatic and non-enzymatic processes) at the molecular level by nuclear magnetic resonance (NMR) and electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS). We found that iodine-NOM interactions may be influenced by NOM hydrophobic aliphatic moieties. From the perspective of ESI-FTICRMS, organo-iodine formulas were ascribed to the groups of unsaturated hydrocarbons, lignins and proteins. Iodate is likely abiotically reduced to reactive iodine species by lignin- and tannin-like compounds or carboxylic-rich alicyclic molecules (CRAM). We also investigated microbial mechanisms in iodine incorporation into NOM. We established that soil bacteria isolated from F-Area of SRS did not accumulate significant amounts of I- (0.2-2%). Intracellular uptake of I- decreases with increasing pH when pH ranged from 4 to 6. In contrast, 44 out of 84 strains isolated from the F-Area of SRS can transform I- to IO 3 - and organo-iodine. In some cases, oxidation was facilitated in the presence of H 2 O 2 . Microbes can also excrete organic acids that enhance I- oxidation by lowering the ambient pH and reacting with H 2 O 2 to form peroxy carboxylic acids. At lower pH values (≤5), H 2 O 2 hydrolysis was the driving force for iodide-oxidation; whereas, at pH ≥ 6, spontaneous decomposition of peroxy carboxylic acids, originating from H 2 O 2 and organic acids were the primary cause of iodide oxidation. Lastly, it was determined that microbial processes involved in Mn (II) are capable of directly oxidizing I- via enzymatic catalysis (i.e., multicopper oxidases), or indirectly through the formation of reactive oxygen species (ROS) and/or biogenic manganese oxides. ROS-mediated oxidation of I- was found to predominate at pH >5, whereas the enzymatic and Mn oxide pathways were more active at pH < 5. Together, this project has resulted in 9 publications in high-impact journals, and the training of 1 Ph.D and 4 undergraduate students.

54 ENVIRONMENTAL SCIENCES↗

Development of Efficient Process for Manufacturing of Thermoplastic Composites with Tailored Properties (CRADA 511)

This is a collaborative effort between Battelle Memorial Institute as manager and operator of Pacific Northwest National Laboratory (PNNL) and ESI North America Inc. (“ESI” or “Participant”) to apply computation and data analytics to the challenge of light weighting with a focus on the battery enclosures of electric vehicles (EVs). EVs use heavy batteries to increase range and power. A complex-shaped battery enclosure is required to meet a host of challenging performance requirements. The ability to virtually develop composite parts such as battery enclosure with tailored properties to meet required performance will be highly valuable to the automotive industry. However, efficient simulation of composite-manufacturing processes remains a challenging issue since simulation involves multiscale models in space and time, highly non-linear and anisotropic behavior, strongly coupled multi-physics, and complex geometries. This work will advance the state of the art by reducing the computational burden of composite optimization by using simulation data from a limited number of configurations off-line and then developing a reduced order model (ROM) using data analytics and machine learning (ML). Develop a data driven approach to link features of the material and manufacturing processes to the mechanical properties of thermoplastic composite parts.

42 ENGINEERING↗

Efficient and Selective Chemical Transformations in Highly Charged and Confined Nanodroplets

The acceleration of chemical reaction rates and the increased product selectivity in microdroplets compared to that in bulk solutions has become a topic of increasing interest that has been extensively characterized by electrospray ionization mass spectrometry (ESI-MS). However, the sources of this acceleration and the detailed relationships between droplet properties and resulting reaction rate acceleration are still under debate. Moreover, droplet properties are governed by multiple interrelated experimental parameters, i.e., electrospray voltage, solution flow rate, etc., which makes it difficult and time-consuming to explore this diverse parameter space using traditional manual experimental or computational approaches. In this work, we developed an automated experimental platform integrating reactions in controlled charged microdroplet environments with ESI-MS characterization and sequential hybrid Bayesian modeling, as well as an optimal experimental design framework, to achieve multidimensional parameter optimization for higher reaction turnover rates, based on a model reaction of tetraethylenepentamine (TEPA) with carbon dioxide. With the current platform, we have achieved automated scans with a range of electrospray voltages and solution flow rates, and determined and optimized parameter settings to achieve increased reaction turnovers. We have also linked this platform to the underlying properties of droplets via a hybrid model incorporating physics, high-level theoretical calculations, and machine learning (ML) approaches. The autonomous platform is broadly applicable to a range of chemical reactions relevant to DOE’s mission in chemical separations, catalysis, and materials synthesis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modelling Hyperglycaemia in an Epithelial Membrane Model: Biophysical Characterisation

Biomimetic models are valuable platforms to improve our knowledge on the molecular mechanisms governing membrane-driven processes in (patho)physiological conditions, including membrane permeability, transport, and fusion. However, current membrane models are over simplistic and do not include the membrane’s lipid remodelling in response to extracellular stimuli. Our study describes the synthesis of glycated dimyristoyl-phosphatidylethanolamine (DMPE-glyc), which was structurally characterised by mass spectrometry (ESI-MS) and quantified by NMR spectroscopy to be further incorporated in a complex phospholipid (PL) membrane model enriched in cholesterol (Chol) and (glyco)sphingolipids (GSL) designed to mimic epithelial membranes (PL/Chol/GSL) under hyperglycaemia conditions. Characterisation of synthesised DMPE-glyc adducts by tandem mass spectrometry (ESI-MS/MS) show that synthetic DMPE-glyc adducts correspond to Amadori products and quantification by 1H NMR spectroscopy show that the yield of glycation reaction was 8%. The biophysical characterisation of the epithelial membrane model shows that excess glucose alters the thermotropic behaviour and fluidity of epithelial membrane models likely to impact permeability of solutes. The epithelial membrane models developed to mimic normo- and hyperglycaemic scenarios are the basis to investigate (poly)phenol-lipid and drug–membrane interactions crucial in nutrition, pharmaceutics, structural biochemistry, and medicinal chemistry.

Reis, Ana (ORCID:0000000245379902)↗

Predicting the glass transition temperature and viscosity of secondary organic material using molecular composition

Secondary organic aerosol (SOA) accounts for a large fraction of submicron particles in the atmosphere. SOA can occur in amorphous solid or semi-solid phase states depending on chemical composition, relative humidity (RH), and temperature. The phase transition between amorphous solid and semi-solid states occurs at the glass transition temperature ( T g ). We have recently developed a method to estimate T g of pure compounds containing carbon, hydrogen, and oxygen atoms (CHO compounds) with molar mass less than 450 g mol -1 based on their molar mass and atomic O : C ratio. In this study, we refine and extend this method for CH and CHO compounds with molar mass up to ~1100 g mol -1 using the number of carbon, hydrogen, and oxygen atoms. We predict viscosity from the T g -scaled Arrhenius plot of fragility (viscosity vs. T g / T ) as a function of the fragility parameter D . We compiled D values of organic compounds from the literature and found that D approaches a lower limit of ~10 (±1.7) as the molar mass increases. We estimated the viscosity of α -pinene and isoprene SOA as a function of RH by accounting for the hygroscopic growth of SOA and applying the Gordon–Taylor mixing rule, reproducing previously published experimental measurements very well. Sensitivity studies were conducted to evaluate impacts of T g , D , the hygroscopicity parameter ( κ ), and the Gordon–Taylor constant on viscosity predictions. The viscosity of toluene SOA was predicted using the elemental composition obtained by high-resolution mass spectrometry (HRMS), resulting in a good agreement with the measured viscosity. We also estimated the viscosity of biomass burning particles using the chemical composition measured by HRMS with two different ionization techniques: electrospray ionization (ESI) and atmospheric pressure photoionization (APPI). Due to differences in detected organic compounds and signal intensity, predicted viscosities at low RH based on ESI and APPI measurements differ by 2–5 orders of magnitude. Complementary measurements of viscosity and chemical composition are desired to further constrain RH-dependent viscosity in future studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numeric and fluid dynamic representation of tornadic double vortex thunderstorms

Current understanding of a double vortex thunderstorm involves a pair of contra-rotating vortices that exists in the dynamic updraft. The pair is believed to be a result of a blocking effect which occurs when a cylindrical thermal updraft of a thunderstorm protrudes into the upper level air and there is a large amount of vertical wind shear between the low level and upper level air layers. A numerical tornado prediction scheme based on the double vortex thunderstorm was developed. The Energy-Shear Index (ESI) is part of the scheme and is calculated from radiosonde measurements. The ESI incorporates parameters representative of thermal instability and blocking effect, and indicates appropriate environments for which the development of double vortex thunderstorms is likely.

Connell, J. R.↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7,500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4-inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm ppm MMH, and diluted vapor samples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sampling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2, and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4 into the ranges of existing TLV detectors.

Barile, R. G.↗

Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases

Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4 inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm MMH, and diluted vapor sarnples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sarnpling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2 and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4, into the ranges of existing TLV detectors.

Barile, R. G.↗

HPLC/ESI-quadrupole ion trap mass spectrometry for characterization and direct quantification of amphoteric and nonionic surfactants in aqueous samples

An amphoteric (cocamidopropylbetaine, CAPB) and a nonionic (alcohol polyethoxylate, AE) surfactant were characterized by electrospray ionization quadrupole ion trap mass spectrometry (ESI-MS) as to their homologue distribution and ionization/fragmentation chemistry. Quantitative methods involving reversed-phase gradient HPLC and (+)ESI-MSn were developed to directly determine these surfactants in hydroponic plant growth medium that received simulated graywater. The predominant homologues, 12 C alkyl CAPB and 9 EO AE, were monitored to represent the total amount of the respective surfactants. The methods demonstrated dynamic linear ranges of 0.5-250 ng (r2 > 0.996) for CAPB and 8-560 ng (r2 > 0.998) for AE homologue mixture, corresponding to minimum quantification limits of 25 ppb CAPB and 0.4 ppm AE with 20-microL injections. This translated into an even lower limit for individual components due to the polydispersive nature of the surfactants. The procedure was successfully employed for the assessment of CAPB and AE biodegradation in a hydroponic plant growth system used as a graywater bioreactor.

NASA Discipline Life Support Systems↗

Simultaneous quantification of poly-dispersed anionic, amphoteric and nonionic surfactants in simulated wastewater samples using C18 high-performance liquid chromatography-quadrupole ion-trap mass spectrometry

This paper describes the development of a guantitative method for direct and simultaneous determination of three frequently encountered surfactants, amphoteric (cocoamphoacetate, CAA), anionic (sodium laureth sulfate, SLES), and nonionic (alcohol ethoxylate, AE) using a reversed-phase C18 HPLC coupled with an ESI ion-trap mass spectrometer (MS). Chemical composition, ionization characteristics and fragmentation pathways of the surfactants are presented. Positive ESI was effective for all three surfactants in agueous methanol buffered with ammonium acetate. The method enables rapid determinations in small sample volumes containing inorganic salts (up to 3.5 g L(-1)) and multiple classes of surfactants with high specificity by applying surfactant specific tandem mass spectrometric strategies. It has dynamic linear ranges of 2-60, 1.5-40, 0.8-56 mg L(-1) with R2 egual or greater than 0.999, 0.98 and 0.999 (10 microL injection) for CAA, SLES, and AE, respectively.

Chromatography, High Pressure Liquid/methods↗

LC/MS Method for the Determination of Stable Isotope Labeled Promethazine in Human Plasma

Promethazine (PMZ) is taken by astronauts orally (PO), intramuscularly (IM) or rectally (PR) for space motion sickness. LC/MS method was developed with off-line solid phase extraction to measure plasma concentrations of PMZ given as stable isotope-labeled (SIL) formulations by the three different routes of administration simultaneously. Samples (0.5ml) were loaded on to Waters Oasis HLB co-polymer cartridges and eluted with 1.0 mL methanol. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 6 min. Acetonitrile/ ammonium acetate (30 mM) in water (3:2, v/v), pH 5.6 plus or minus 0.1, was used as the mobile phase for separation. Concentrations of PMZ, PMZ-d4 and PMZ-d7 and chlorpromazine (internal standard) were determined using a Micromass ZMD single quadrupole mass spectrometer with Electrospray Ionization (ESI). ESI mass spectra were acquired in positive ion mode with selected ion monitoring of [M+ H]dot plus. The method is rapid, reproducible and the assay specific parameters are listed in a table. A novel, sensitive and specific method for the measurement of PMZ and SIL PMZ in human plasma is reported.

Zuwei, Wang↗

Determination of Scopolamine in Human Saliva Using Solid Phase Extraction and LC/MS/MS

Purpose: Scopolamine is the preferred treatment for motion sickness during space flight because of its quick onset of action, short half-life and favorable side-effect profile. The dose administered depends on the mode of administration and usually ranges between 0.1 and 0.8 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids by using conventional HPLC methods. To measure scopolamine in saliva and thereby to evaluate the pharmacokinetics of scopolamine, we developed an LC/MS/MS method using off-line solid phase extraction. Method: Samples (0.5mL) were loaded onto Waters Oasis HLB co-polymer cartridges (10 mg, 1 mL) and eluted with 0.5 mL methanol without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 4 minutes. The mobile phase for separation was 90:10 (v/v) methanol: ammonium acetate (2 mM) in water, pH 5.0 +/- 0.1. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 yields 138.1 and internal standard (IS) hyoscyamine m/z = 290.2 yields 124.1. Results: The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at 1.7 and 3.2 min respectively. The linear range is 50-5000 pg/mL for scopolamine in saliva with correlation coefficients > 0.99 with a CV < 0.5 %. The intra-day and inter-day CVs are < 15 % for quality control samples with concentrations of 75, 300, 750 and 3000 pg/mL of scopolamine in human saliva. Conclusion: Solid phase extraction allows more rapid sample preparation and greater precision than liquid extraction. Furthermore, we increased the sensitivity and specificity by adjusting the LC mobile phase and using an MS/MS detector.

Wang, Zuwei↗