Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ERROR CORRECTING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Chromatic-aberration-corrected diffractive lenses for ultra-broadband focusing

We exploit the inherent dispersion in diffractive optics to demonstrate planar chromatic-aberration-corrected lenses. Specifically, we designed, fabricated and characterized cylindrical diffractive lenses that efficiently focus the entire visible band (450 nm to 700 nm) onto a single line. These devices are essentially pixelated, multi-level microstructures. Experiments confirm an average optical efficiency of 25% for a three-wavelength apochromatic lens whose chromatic focus shift is only 1.3 μm and 25 μm in the lateral and axial directions, respectively. Super-achromatic performance over the continuous visible band is also demonstrated with averaged lateral and axial focus shifts of only 1.65 μm and 73.6 μm, respectively. These lenses are easy to fabricate using single-step grayscale lithography and can be inexpensively replicated. Furthermore, these devices are thin (<3 μm), error tolerant, has low aspect ratio (<1:1) and offer polarization-insensitive focusing, all significant advantages compared to alternatives that rely on metasurfaces. Lastly, our design methodology offers high design flexibility in numerical aperture and focal length, and is readily extended to 2D.

36 MATERIALS SCIENCE↗

Field validation of an actuated convergent-beam acoustic Doppler profiler for high resolution flow mapping

Abstract Energetic river and tidal flow environments feature complex hydrodynamic conditions. Conventional acoustic Doppler profiling instrumentation typically requires assumptions of flow homogeneity over the spatial scales of the divergent beam separation. This removes the ability to measure spatio-temporal variability within the flow. However, velocity variability within these spatial scales is often important in the design of structures and devices exposed to such flow, informing dynamic and peak hydrodynamic load predictions. The research presented outlines the development and testing of a flow measurement instrument consisting of multiple spatially-separated single beam acoustic Doppler profilers converging on a remote focal point, the location of which can be programmatically adjusted through actuation. This increases the spatial resolution at which remote field measurements can be made in energetic flow environments. Field testing of the instrument was conducted in a tidal channel at Sequim Bay Inlet, WA, USA. Results are compared with independent reference measurements made by a co-located, motion-corrected acoustic Doppler velocimeter. This comparison, across tidal velocities of 0.4–0.7 m s −1 , showed a mean velocity error of 0.5%–13.2% across nine sample locations within a 3.00 m × 2.25 m plane. To the authors’ knowledge, this is the first publication of flow velocity results from non-intrusive acoustic measurements at an off-axis, focal point location that features 3D positional control.

13 HYDRO ENERGY↗

Extending quantum probabilistic error cancellation by noise scaling

Here, we propose a general framework for quantum error mitigation that combines and generalizes two techniques: probabilistic error cancellation (PEC) and zero-noise extrapolation (ZNE). Similar to PEC, the proposed method represents ideal operations as linear combinations of noisy operations that are implementable on hardware. However, instead of assuming a fixed level of hardware noise, we extend the set of implementable operations by noise scaling. By construction, this method encompasses both PEC and ZNE as particular cases and allows us to investigate a larger set of hybrid techniques. For example, gate extrapolation can be used to implement PEC without requiring knowledge of the device’s noise model, e.g., avoiding gate-set tomography. Alternatively, probabilistic error reduction can be used to estimate expectation values at intermediate virtual noise strengths (below the hardware level), leading to partially mitigated results at a lower sampling cost. Moreover, multiple results obtained with different noise-reduction factors can be further postprocessed with ZNE to better approximate the zero-noise limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SPARC 3D Field Physics and Support of the Non-Axisymmetric Coil Assessment

Commonwealth Fusion Systems (CFS) is deploying SPARC, a net-energy tokamak, by 2025. A notable challenge facing all tokamak approaches to fusion energy production is maintaining a stable plasma and thereby steady energy production. “Disruptions” to plasma operation are often encountered in devices when they operate at high normalized pressure, high normalized density, or high normalized current. SPARC is unique in that it is expected to demonstrate Q>=2 in a plasma with low normalized pressure and density, but with a more modest current limit buffer sufficient to avoid disruptions. Due to both the high normalized current and high magnetic field of the SPARC design, it is expected to decrease its relative resilience to instabilities driven by non-axisymmetry in the externally applied magnetic field, termed ‘error fields’. To prevent error field driven instabilities, a primary line of defense is strict engineering tolerances in magnet fabrication and installation. A secondary line of defense is a purpose-built set of magnetic coils to correct these errors, termed error field correction coils (EFCCs). The overarching goals of this INFUSE project were to evaluate the effectiveness of the EFCCs in the SPARC design and provide guidance as to how to improve this effectiveness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring the electron temperature and identifying plasma detachment using machine learning and spectroscopy

A machine learning approach has been implemented to measure the electron temperature directly from the emission spectra of a tokamak plasma. This approach utilized a neural network (NN) trained on a dataset of 1865 time slices from operation of the DIII-D tokamak using extreme ultraviolet/vacuum ultraviolet emission spectroscopy matched with high-accuracy divertor Thomson scattering measurements of the electron temperature, T e . This NN is shown to be particularly good at predicting T e at low temperatures (T e < 10 eV) where the NN demonstrated a mean average error of less than 1 eV. Trained to detect plasma detachment in the tokamak divertor, a NN classifier was able to correctly identify detached states (T e < 5 eV) with a 99% accuracy (an F 1 score of 0.96) at an acquisition rate 10× faster than the Thomson scattering measurement. The performance of the model is understood by examining a set of 4800 theoretical spectra generated using collisional radiative modeling that was also used to predict the performance of a low-cost spectrometer viewing nitrogen emission in the visible wavelengths. Furthermore, these results provide a proof-of-principle that low-cost spectrometers leveraged with machine learning can be used to boost the performance of more expensive diagnostics on fusion devices and be used independently as a fast and accurate T e measurement and detachment classifier.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measured Energy-Dependent Neutron Attenuation Through the Stacked Printed Circuit Boards

Engineers often stack printed circuit boards (PCBs), populated with semiconductor devices, one behind the other in neutron beams to improve the error statistics in radiation-effects tests. As the neutron beam traverses through the boards, the neutron flux is both attenuated and the energy spectrum changes, which may have a significant impact on the results of such tests. In this work, we have developed a technique to measure the energy-dependent neutron attenuation due to the PCBs and to determine the energy-dependent effective cross section of neutron interactions with a single PCB. With this effective cross section, engineers can calculate the change in the neutron energy spectrum and the total neutron attenuation after any number of identical PCBs in the stack. This information will allow test engineers to partially correct inaccuracies in soft error tests.

42 ENGINEERING↗

Mitigation of the Brighter-fatter Effect in the LSST Camera

Abstract Thick, fully depleted charge-coupled devices are known to exhibit nonlinear behavior at high signal levels due to the dynamic behavior of charges collecting in the potential wells of pixels, called the brighter-fatter effect (BFE). The effect results in distorted images of bright calibration stars, creating a flux-dependent point-spread function that if left unmitigated, could make up a large fraction of the error budget in Stage IV weak-lensing (WL) surveys such as the Legacy Survey of Space and Time (LSST). In this paper, we analyze image measurements of flat fields and artificial stars taken at different illumination levels with the LSST Camera (LSSTCam) at SLAC National Accelerator Laboratory in order to quantify this effect in the LSSTCam before and after a previously introduced correction technique. We observe that the BFE evolves anisotropically as a function of flux due to higher-order BFEs, which violates the fundamental assumption of this correction method. We then introduce a new method based on a physically motivated model to account for these higher-order terms in the correction, and then we test the modified correction on both data sets. We find that the new method corrects the effect in flat fields better than it corrects the effect in artificial stars, which we suggest is the result of sub-pixel physics not included in this correction model. We use these results to define a new metric for the full-well capacity of our sensors and advise image processing strategies to further limit the impact of the effect on LSST WL science pathways.

47 OTHER INSTRUMENTATION↗

Q-BEEP: Quantum Bayesian Error Mitigation Employing Poisson Modeling over the Hamming Spectrum

Quantum computing technology has grown rapidly in recent years, with new technologies being explored, error rates being reduced, and quantum processor’s qubit capacity growing. However, near-term quantum algorithms are still unable to be induced without compounding consequential levels of noise, leading to non-trivial erroneous results. Quantum Error Correction (in-situ error mitigation) and Quantum Error Mitigation (post-induction error mitigation) are promising fields of research within the quantum algorithm scene, aiming to alleviate quantum errors, increasing the overall fidelity and hence the overall quality of circuit induction. Earlier this year, a pioneering work, namely HAMMER, published in ASPLOS-22 demonstrated the existence of a latent structure regarding post-circuit induction errors when mapping to the Hamming spectrum. However, they intuitively assumed that errors occur in local clusters, and that at higher average Hamming distances this structure falls away. In this work, we show that such a correlation structure is not only local but extends certain non-local clustering patterns which can be precisely described by a Poisson distribution model taking the input circuit, the device run time status (i.e., calibration statistics) and qubit topology into consideration. Using this quantum error characterizing model, we developed an iterative algorithm over the generated Bayesian network state-graph for post-induction error mitigation. Thanks to more precise modeling of the error distribution latent structure and the new iterative method, our Q-Beep approach provides state of the art performance and can boost circuit execution fidelity by up to 234.6% on Bernstein-Vazirani circuits and on average 71.0% on QAOA solution quality, using 16 practical IBMQ quantum processors. For other benchmarks such as those in QASMBench, the fidelity improvement is up to 17.8%. Q-Beep is a light-weight post-processing technique that can be performed offline and remotely, making it a useful tool for quantum vendors to integrate and provide more reliable circuit induction results.

Stein, Samuel A.↗

Magellan adaptive optics first-light observations of the exoplanet β PIC b. II. 3–5 μm direct imaging with MagAO+Clio, and the empirical bolometric luminosity of a self-luminous giant planet

Young giant exoplanets are a unique laboratory for understanding cool, low-gravity atmospheres. A quintessential example is the massive extrasolar planet β Pic b, which is 9 AU from and embedded in the debris disk of the young nearby A6V star β Pictoris. We observed the system with first light of the Magellan Adaptive Optics (MagAO) system. In Paper I we presented the first CCD detection of this planet with MagAO+VisAO. Here we present four MagAO+Clio images of β Pic b at 3.1 μm, 3.3 μm, L′, and M{sup ′}, including the first observation in the fundamental CH{sub 4} band. To remove systematic errors from the spectral energy distribution (SED), we re-calibrate the literature photometry and combine it with our own data, for a total of 22 independent measurements at 16 passbands from 0.99 to 4.8 μm. Atmosphere models demonstrate the planet is cloudy but are degenerate in effective temperature and radius. The measured SED now covers >80% of the planet’s energy, so we approach the bolometric luminosity empirically. We calculate the luminosity by extending the measured SED with a blackbody and integrating to find log(L{sub bol}/L{sub ⊙}) = −3.78±0.03. From our bolometric luminosity and an age of 23 ± 3 Myr, hot-start evolutionary tracks give a mass of 12.7 ± 0.3 M{sub Jup}, radius of 1.45 ± 0.02 R{sub Jup}, and T{sub eff} of 1708 ± 23 K (model-dependent errors not included). Our empirically determined luminosity is in agreement with values from atmospheric models (typically −3.8 dex), but brighter than values from the field-dwarf bolometric correction (typically −3.9 dex), illustrating the limitations in comparing young exoplanets to old brown dwarfs.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative Electroluminescence Imaging Analysis for Performance Estimation of PID-Influenced PV Modules

An empirical method for estimating relative power losses caused by potential-induced degradation (PID) for p-type solar cells and modules using quantitative electroluminescence (EL) analysis (QELA) is presented. First, EL images are corrected for camera- and perspective distortion. The relative power loss map is then calculated from the logarithmic ratio of two EL images, taken either before and after PID degradation or at different applied currents. Only the cell average of the resulting power loss map is evaluated. The highest power loss across each string is averaged to obtain the overall power loss. Consequently, for modules with three strings, three cells are averaged. The resulting power loss depends on the current applied. The conversion to equivalent irradiance allows for comparison of measured and estimated device performance. The analysis of roughly 2000 EL images and related current-voltage (I-V) curves indicates a good agreement between flash-test-measured and performance estimated using QELA. A relative root mean square error of 1-3% can be achieved.

14 SOLAR ENERGY↗

Quantum state preparation by adiabatic evolution with custom gates

Quantum state preparation by adiabatic evolution is currently rendered ineffective by the long implementation times of the underlying quantum circuits, comparable to the decoherence time of present and near-term quantum devices. These implementation times can be significantly reduced by realizing these circuits with custom gates. Using classical computing, we model the output of a realistic two-qubit processor implementing the adiabatic evolution of a two-spin system by means of custom gates. This modeled output is then compared with the results of quantum simulations solving the same problem on IBM Quantum (IBMQ) systems. Additionally, when used to emulate the behavior of the IBMQ quantum circuit, our realistic model yields state fidelities ranging from 65% to 85%, similar to the actual performance of a diverse set of IBMQ devices. When we reduced the implementation time by using custom gates, however, the loss of fidelity was reduced by at least a factor of 4, allowing us to accurately extract the energy of the target state. This improvement is enough to render adiabatic evolution useful for quantum state preparation for small systems or as a preconditioner for other state preparation methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spatial noise correlations in a Si/SiGe two-qubit device from Bell state coherences

Here, we study spatial noise correlations in a Si/SiGe two-qubit device with integrated micromagnets. Our method relies on the concept of decoherence-free subspaces, whereby we measure the coherence time for two different Bell states, designed to be sensitive only to either correlated or anticorrelated noise, respectively. From these measurements we find weak correlations in low-frequency noise acting on the two qubits, while no correlations could be detected in high-frequency noise. We expect nuclear spin noise to have an uncorrelated nature. A theoretical model and numerical simulations give further insight into the additive effect of multiple independent (anti)correlated noise sources with an asymmetric effect on the two qubits as can result from charge noise. Such a scenario in combination with nuclear spins is plausible given the data and the known decoherence mechanisms. This work is highly relevant for the design of optimized quantum error correction codes for spin qubits in quantum dot arrays, as well as for optimizing the design of future quantum dot arrays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Equilibrium reconstruction based on core magnetic measurement and its applications on equilibrium transition in Joint-TEXT tokamak

Evaluation and reconstruction of plasma equilibrium, especially to resolve the safety factor profile, is imperative for advanced tokamak operation and physics study. Based on core magnetic measurement by the high resolution laser polarimeter-interferometer system (POLARIS), the equilibrium of Joint-TEXT (J-TEXT) plasma is reconstructed and profiles of safety factor, current density, and electron density are, therefore, obtained with high accuracy and temporal resolution. The equilibrium reconstruction procedure determines the equilibrium flux surfaces essentially from the data of POLARIS. Refraction of laser probe beam, a major error source of the reconstruction, has been considered and corrected, which leads to improvement of accuracy more than 10%. The error of reconstruction has been systematically assessed with consideration of realistic diagnostic performance and scrape-off layer region of plasma, and its accuracy has been verified. Fast equilibrium transitions both within a single sawtooth cycle and during the penetration of resonant magnetic perturbation have been investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An in-depth field validation of “DUSST”: A novel low-maintenance soiling measurement device

This study presents indoor and field validation results for two versions of the “DUSST” optical soiling sensor, intended to be a low-cost and low-maintenance device for measuring photovoltaic soiling losses. Indoor testing covers irradiance calibration and temperature dependencies, which are necessary to achieve high accuracy, low uncertainty field measurements. Field testing includes an array of different environments including Saudi Arabia, California, Utah, and Colorado. DUSST versions include a configuration with a 530-nm light emitting diode (LED) (discussed in previous work) and a unit with seven white LEDs and a polycarbonate collimating optic. The new design increases light intensity fivefold and demonstrates a single linear calibration coefficient is effective to measure soiling losses as high as 75%. Field data from Utah and California demonstrate that daily soiling loss measurements and soiling rate calculations closely match both reference cell and full-size module measurements of soiling losses and soiling rates. Corrective methods employed on the Utah DUSST sensor suggest that it is possible to achieve measurement errors as low as ±0.1% at two standard deviations. Field data from both Colorado and Saudi Arabia demonstrate that LED lens soiling can occur and that further design optimizations are needed. The lesson learned from all the field deployment locations suggests directions for future design improvements.

14 SOLAR ENERGY↗

Design and performance of a variable gap system for thermal conductivity measurements of high temperature, corrosive, and reactive fluids

We report high-temperature fluids such as molten salts, liquid metals, and gasses are being proposed for many advanced energy systems including thermal energy storage devices, concentrating solar plants, and advanced nuclear reactor designs. However, the chemical behavior and thermophysical properties of many of these fluids have not been well characterized, which hinders the design, modeling, safety analysis, and deployment of these systems. Thermal conductivity is a property that is especially limited by existing measurement capabilities, which are subject to errors caused by convection, material interaction, radiative heat transfer, and instrument degradation. Therefore, there is a lack of standard, systematic measurement techniques for high-temperature, reactive, and corrosive fluids. In this work, the development of a variable gap thermal conductivity measurement system is detailed. The system is designed to measure the thermal conductivity of highly corrosive and reactive fluids, and survive operation between 100 °C and 800 °C. The effects of convection are minimized by limiting the thickness of the specimen to thin sizes (<0.3 mm). Corrections for radiative heat transfer were included in the working equations to consider specimens with varying optical properties. The design, construction, instrumentation, operating principles, and data analysis techniques are discussed in detail. The system was tested up to 500 °C using helium gas and molten KNO 3 -NaNO 3 to verify the measurement technique and determine the sources of error. At 300 and 400 °C KNO 3 -NaNO 3 , results showed maximum relative error of 6% when compared to results in the literature. The helium results were within 13% of those in the literature at 300 and 400 °C. Higher errors were observed at 500 °C for both fluids, and the sources of these errors are discussed.

42 ENGINEERING↗

Registration of human skull computed tomography data to an ultrasound treatment space using a sparse high frequency ultrasound hemispherical array

Purpose: Transcranial focused ultrasound (FUS) shows great promise for a range of therapeutic applications in the brain. Current clinical investigations rely on the use of magnetic resonance imaging (MRI) to monitor treatments and for the registration of preoperative computed tomography (CT)-data to the MR images at the time of treatment to correct the sound aberrations caused by the skull. For some applications, MRI is not an appropriate choice for therapy monitoring and its cost may limit the accessibility of these treatments. An alternative approach, using high frequency ultrasound measurements to localize the skull surface and register CT data to the ultrasound treatment space, for the purposes of skull-related phase aberration correction and treatment targeting, has been developed. Methods: A prototype high frequency, hemispherical sparse array was fabricated. Pulse-echo measurements of the surface of five ex vivo human skulls were made, and the CT datasets of each skull were obtained. The acoustic data were used to rigidly register the CT-derived skull surface to the treatment space. The ultrasound-based registrations of the CT datasets were compared to the gold-standard landmark-based registrations. Results: The results show on an average sub-millimeter (0.9 ± 0.2 mm) displacement and subdegree (0.8° ± 0.4°) rotation registration errors. Numerical simulations predict that registration errors on this scale will result in a mean targeting error of 1.0 ± 0.2 mm and reduction in focal pressure of 1.0% ± 0.6% when targeting a midbrain structure (e.g., hippocampus) using a commercially available low-frequency brain prototype device (InSightec, 230 kHz brain system). Conclusions: If combined with ultrasound-based treatment monitoring techniques, this registration method could allow for the development of a low-cost transcranial FUS treatment platform to make this technology more widely available.

60 APPLIED LIFE SCIENCES↗

A Chip-Scale Oscillation-Mode Optomechanical Inertial Sensor Near the Thermodynamical Limits

Modern navigation systems integrate the global positioning system (GPS) with an inertial navigation system (INS), which complement each other for correct attitude and velocity determination. Here, the core of the INS integrates accelerometers and gyroscopes used to measure forces and angular rate in the vehicular inertial reference frame. With the help of gyroscopes and by integrating the acceleration to compute velocity and distance, precision and compact accelerometers with sufficient accuracy can provide small–error location determination. Solid–state implementations, through coherent readout, can provide a platform for high performance acceleration detection. In contrast to prior accelerometers using piezoelectric or capacitive readout techniques, optical readout provides narrow–linewidth high–sensitivity laser detection along with low–noise resonant optomechanical transduction near the thermodynamical limits. Here an optomechanical inertial sensor with an 8.2 µg Hz –1/2 velocity random walk (VRW) at an acquisition rate of 100 Hz and 50.9 µg bias instability is demonstrated, suitable for applications, such as, inertial navigation, inclination sensing, platform stabilization, and/or wearable device motion detection. Driven into optomechanical sustained–oscillation, the slot photonic crystal cavity provides radio–frequency readout of the optically–driven transduction with an enhanced 625 µg Hz –1 sensitivity. Measuring the optomechanically–stiffened oscillation shift, instead of the optical transmission shift, provides a 220× VRW enhancement over pre–oscillation mode detection.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

TH-A-BRC-00: New Task Groups for External Beam QA: An Overview

AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline of possible dosimetry protocols. The report will be reviewed by the AAPM Working Group on Recommendations for Radiotherapy External Beam Quality Assurance and then by the AAPM Science Council before publication in Medical Physics Survey of possible calibration protocols for calibration of Gamma Stereotactic Radiosurgery (GSR) devices Overview of modern Quality Assurance techniques for GSR AAPM TG-218 Tolerance Levels and Methodologies for IMRT Verification QA - Moyed Miften Patient-specific IMRT QA measurement is a process designed to identify discrepancies between calculated and delivered doses. Error tolerance limits are not well-defined or consistently applied across centers. The AAPM TG-218 report has been prepared to improve the understanding and consistency of this process by providing recommendations for methodologies and tolerance limits in patient-specific IMRT QA. Learning Objectives: Review measurement methods and methodologies for absolute dose verification Provide recommendations on delivery methods, data interpretation, the use of analysis routines and choice of tolerance limits for IMRT QA Sonja Dieterich has a research agreement with Sun Nuclear Inc. Steven Goetsch is a part-time consultant for Elekta.

60 APPLIED LIFE SCIENCES↗