Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EDL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

OSIRIS-REx Entry, Descent, and Landing Performance

The Origins, Spectral Interpretation, Resource Identification, Security, Regolith Explorer (OSIRIS-REx) was the third mission in NASA’s New Frontiers program. OSIRIS-REx launched out of Cape Canaveral, Florida on September 8, 2016, with a science goal to return a minimum of 60 g of a primitive asteroid’s surface, specifically the near-Earth asteroid Bennu. The sample return capsule (SRC) successfully touched down at UTTR on the morning of September 24, 2023. The entry, descent, and landing (EDL) sequence had an off-nominal deployment of the parachute, but the spacecraft safely landed within the pre-flight prediction of the landing ellipse and the payload was safely recovered. This paper discusses the pre-flight EDL modeling and simulation and focus on predictions for EDL operations. Flight observations such as timeline are compared to the predicted timeline produced by the EDL simulation.

EDL↗

Application of A Dual-Quaternion Six Degree-of-Freedom Guidance to Human-Scale Mars Entry, Descent, and Landing

Landing humans on Mars comes with many challenges, including the execution of a safe and precise entry, descent, and landing (EDL) sequence. Various NASA studies have shown that there are a variety of EDL guidance methods that potentially offer solutions to the human-scale EDL precision landing problem and work is ongoing to assess new and novel methods. As part of these ongoing studies, a dual-quaternion-based six degree-of-freedom guidance algorithm was implemented in the Program to Optimize Simulated Trajectories II (POST2), a NASA-and industry-standard spacecraft trajectory and vehicle design tool. This algorithm considers both translational and rotational dynamics and casts the trajectory optimization problem as a quadratically constrained quadratic program (QCQP) with various constraints at discrete nodes throughout the trajectory. The QCQP problem is solved via an alternating direction method of multipliers (ADMM) approach, and the output is a discretized optimal trajectory. The guidance is applied to a NASA reference human-scale Mars EDL system, and results are compared and discussed.

Optimization↗

Modeling salt adsorption in electrical double layer for capacitive deionization

Abstract This work presents an electrical double layer (EDL) model for capacitive deionization (CDI) by intercorrelating the salt adsorption, the electrode voltage, and the surface charge density. The counterion condensation is considered a crucial contribution to salt adsorption because of the high surface charge density in the charged micropores. The counterions condense when the surface charge density exceeds a critical value, which is predicted by the counterion condensation theory. The EDL model accurately correlates the NaCl salt adsorption and electrode voltage with various surface charge densities and well predicts the salt adsorption in a wide range of external salt concentrations. The EDL model reproduces the non‐monotonic relationship between the salt adsorption and the specific surface area observed in experiments and provides an explanation from the modeling perspective. Exhibiting superior accuracy and predictability for salt adsorption, the EDL model could serve as an enabling tool contributing to the development of CDI processes.

Lin, Yu‐Jeng↗

Cancer cachexia decreases specific force and accelerates fatigue in limb muscle

Highlights: •C-26 cancer cachexia causes a significant decrease in limb muscle absolute force. •C-26 cancer cachexia causes a significant decrease in limb muscle specific force. •C-26 cancer cachexia decreases fatigue resistance in the soleus muscle. •C-26 cancer cachexia prolongs time to peak twitch tension in limb muscle. •C-26 cancer cachexia prolongs one half twitch relaxation time in limb muscle. -- Abstract: Cancer cachexia is a complex metabolic syndrome that is characterized by the loss of skeletal muscle mass and weakness, which compromises physical function, reduces quality of life, and ultimately can lead to mortality. Experimental models of cancer cachexia have recapitulated this skeletal muscle atrophy and consequent decline in muscle force generating capacity. However, more recently, we provided evidence that during severe cancer cachexia muscle weakness in the diaphragm muscle cannot be entirely accounted for by the muscle atrophy. This indicates that muscle weakness is not just a consequence of muscle atrophy but that there is also significant contractile dysfunction. The current study aimed to determine whether contractile dysfunction is also present in limb muscles during severe Colon-26 (C26) carcinoma cachexia by studying the glycolytic extensor digitorum longus (EDL) muscle and the oxidative soleus muscle, which has an activity pattern that more closely resembles the diaphragm. Severe C-26 cancer cachexia caused significant muscle fiber atrophy and a reduction in maximum absolute force in both the EDL and soleus muscles. However, normalization to muscle cross sectional area further demonstrated a 13% decrease in maximum isometric specific force in the EDL and an even greater decrease (17%) in maximum isometric specific force in the soleus. Time to peak tension and half relaxation time were also significantly slowed in both the EDL and the solei from C-26 mice compared to controls. Since, in addition to postural control, the oxidative soleus is also important for normal locomotion, we further performed a fatigue trial in the soleus and found that the decrease in relative force was greater and more rapid in solei from C-26 mice compared to controls. These data demonstrate that severe cancer cachexia causes profound muscle weakness that is not entirely explained by the muscle atrophy. In addition, cancer cachexia decreases the fatigue resistance of the soleus muscle, a postural muscle typically resistant to fatigue. Thus, specifically targeting contractile dysfunction represents an additional means to counter muscle weakness in cancer cachexia, in addition to targeting the prevention of muscle atrophy.

60 APPLIED LIFE SCIENCES↗

Skeletal muscle secretion of IL-6 is muscle type specific: Ex vivo evidence

Highlights: • Ex vivo incubation of freshly isolated mouse skeletal in a physiological condition showed inducible secretion of myokines. • IL-6 secretion was only induced from slow oxidative muscle soleus but not from fast glycolytic muscle EDL. • EDL has secretory function with different secretome pattern from soleus. • This is the first evidence that skeletal muscle secretion of myokines is muscle type specific. Emerging evidence indicates that skeletal muscle possesses endocrine function to secret myokines. Interleukin 6 (IL-6) is a well-characterized myokine that is involved in regulation of metabolism and muscle function. Metabolism type and contractile dynamics vary in different muscle types. It is not clear, however, if IL-6 secretion differs in different muscle types. In this study, we first established an ex vivo approach to test the inducible muscle secretion. Freshly isolated muscles were incubated in Krebs solution at 37 °C with oxygen supply. Secreted IL-6 in the incubation media was measure using Western blot and ELISA assay. We first confirmed that the IL-6 release was inducible by treating the incubated muscle with a cytokine stimulant. We demonstrated that physiological temperature (37 °C) and O{sub 2} supply were essential for the induction of IL-6 release from the incubated muscle, suggesting it is a controlled secretion rather than a spontaneous leak. Using this approach, we found that IL-6 release was only inducible from soleus muscle but not EDL muscle. We further showed that IL-6 protein level was higher in slow oxidative muscle fibers. Moreover, we showed that EDL, although lacks of IL-6 release, surely has inducible secretory function that had different secretory pattern from soleus.

60 APPLIED LIFE SCIENCES↗

Current rectification for transport of room-temperature ionic liquids through conical nanopores

Here, we studied the transport of room-temperature ionic liquids (RTILs) through charged conical nanopores using a Landau-Ginzburg-type continuum model that takes steric effect and strong ion-ion correlations into account. When the surface charge is uniform on the pore wall, weak current rectification is observed. When the charge density near the pore base is removed, the ionic current is greatly suppressed under negative bias voltage while nearly unchanged under positive bias voltage, thereby leading to enhanced current rectification. These predictions agree qualitatively with prior experimental observations, and we elucidated them by analyzing the different components of the ionic current and the structural changes of electrical double layers (EDLs) at the pore tip under different bias voltages and surface charge patterns. These analyses reveal that the different modifications of the EDL structure near the pore tip by the positive and negative bias voltages cause the current rectification and the observed dependence on the distribution of surface charge on the pore wall. The fact that the current rectification phenomena are captured qualitatively by the simple model originally developed for describing EDLs at equilibrium conditions suggests that this model may be promising for understanding the ionic transport under nonequilibrium conditions when the EDL structure is strongly perturbed by external fields.

36 MATERIALS SCIENCE↗

Boosting the Performance of Ionic-Liquid-Based Supercapacitors with Polar Additives

Recent years have witnessed growing interests in both the fundamentals and applications of electric double layer capacitors (EDLCs), also known as supercapacitors. A number of strategies have been explored to optimize the device performance in terms of both the energy and power densities. Because the properties of electric double layers (EDL) are sensitive to ion distributions in the close vicinity of the electrode surfaces, the supercapacitor performance is sensitive to both the electrode pore structure and the electrolyte composition. In this work, we study the effects of polar additives on EDLC capacitance using the classical density functional theory within the framework of a coarse-grained model for the microscopic structure of the porous electrodes and room-temperature ionic liquids. The theoretical results indicate that a highly polar, low-molecular-weight additive is able to drastically increase the EDLC capacitance at low bulk concentration. Additionally, the additive is able to dampen the oscillatory dependence of the capacitance on the pore size, thereby boosting the performance of amorphous electrode materials. The theoretical predictions are directly testable with experiments and provide new insights into the additive effects on EDL properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gate-Induced Metal–Insulator Transition in MoS 2 by Solid Superionic Conductor LaF 3

Electric-double-layer (EDL) gating with liquid electrolyte has been a powerful tool widely used to explore emerging interfacial electronic phenomena. Due to the large EDL capacitance, a high carrier density up to 10 14 cm –2 can be induced, directly leading to the realization of field-induced insulator to metal (or superconductor) transition. However, the liquid nature of the electrolyte has created technical issues including possible side electrochemical reactions or intercalation, and the potential for huge strain at the interface during cooling. In addition, the liquid coverage of active devices also makes many surface characterizations and in situ measurements challenging. Here, we demonstrate an all solid-state EDL device based on a solid superionic conductor LaF 3 , which can be used as both a substrate and a fluorine ionic gate dielectric to achieve a wide tunability of carrier density without the issues of strain or electrochemical reactions and can expose the active device surface for external access. Based on LaF 3 EDL transistors (EDLTs), we observe the metal–insulator transition in MoS 2 . Interestingly, the well-defined crystal lattice provides a more uniform potential distribution in the substrate, resulting in less interface electron scattering and therefore a higher mobility in MoS 2 transistors. Finally, this result shows the powerful gating capability of LaF 3 solid electrolyte for new possibilities of novel interfacial electronic phenomena.

36 MATERIALS SCIENCE↗

Molecular-Scale Structure of Electrode–Electrolyte Interfaces: The Case of Platinum in Aqueous Sulfuric Acid

Knowledge of the molecular composition and electronic structure of electrified solid-liquid interfaces is key to understanding elemental processes in heterogeneous reactions. Using X-ray absorption spectroscopy in the interface-sensitive electron yield mode (EY-XAS), first-principles electronic structure calculations, and multiscale simulations, we determined the chemical composition of the interfacial region of a polycrystalline platinum electrode in contact with aqueous sulfuric acid solution at potentials between the hydrogen and oxygen evolution reactions. We found that between 0.7 and 1.3 V vs Ag/AgCl the electrical double layer (EDL) region comprises adsorbed sulfate ions with hydrated hydronium ions in the next layer. No evidence was found for bisulfate or Pt-O/Pt-OH species, which have very distinctive spectral signatures. In addition to resolving the long-standing issue of the EDL structure, our work establishes interface- and element-sensitive EY-XAS as a powerful spectroscopic tool for studying condensed phase, buried solid-liquid interfaces relevant to various electrochemical processes and devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strong stretching theory for pH-responsive polyelectrolyte brushes in large salt concentrations

Here, we develop a theory for describing the thermodynamics, configuration, and electrostatics of strongly-stretched, pH-responsive polyelectrolyte (PE) brushes in the presence of large salt concentrations. The aim of the paper, therefore, is to study the properties of a PE brush in a salt concentration regime (namely, large concentrations of several molars) that has been hitherto unexplored theoretically in the context of PE brushes but can be routinely encountered in molecular scale simulations of the problem. The brushes are modelled using our recently developed augmented Strong Stretching Theory (SST), while the effect of the presence of the large salt concentration is accounted for by including the contributions of three different types of non-Poisson–Boltzmann (non-PB) effects to the free energy description of the PE brush induced electric double layer (EDL). These non-PB effects are ionic non-mean-field ion–ion correlations, solvent polarization, and the finite size effect of the ions and water dipoles. We study the individual influences of these different effects and show that the ion–ion correlations and solvent polarization effect reduce the brush height which consequently enhances the monomer density and leads to an electrostatic potential distribution of the brush induced EDL that has a larger magnitude at near-wall locations and becomes zero at shorter distances from the wall. The finite size effect, on the other hand, increases the brush height and therefore, weakens the monomer density and leads to a smaller near-wall magnitude of the EDL potential that becomes zero at larger distances from the wall. In time, we consider the impact of all the three non-PB effects simultaneously and show that the ion–ion correlations and solvent polarization effect dominate the size effects and dictate the overall brush configuration and the EDL electrostatics. We also point out that the influence of all the three non-PB effects becomes the largest for a larger salt concentration and a smaller bulk pH. Finally, we compare our theoretical predictions with those obtained from our recently developed all-atom MD simulation model and obtain an excellent match.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Proton conducting sodium alginate electrolyte laterally coupled low-voltage oxide-based transistors

Solution-processed sodium alginate electrolyte film shows a high proton conductivity of ∼5.5 × 10{sup −3} S/cm and a high lateral electric-double-layer (EDL) capacitance of ∼2.0 μF/cm{sup 2} at room temperature with a relative humidity of 57%. Low-voltage in-plane-gate indium-zinc-oxide-based EDL transistors laterally gated by sodium alginate electrolytes are fabricated on glass substrates. The field-effect mobility, current ON/OFF ratio, and subthreshold swing of such EDL transistors are estimated to be 4.2 cm{sup 2} V{sup −1} s{sup −1}, 2.8 × 10{sup 6}, and 130 mV/decade, respectively. At last, a low-voltage driven resistor-load inverter is also demonstrated. Such in-plane-gate EDL transistors have potential applications in portable electronics and low-cost biosensors.

36 MATERIALS SCIENCE↗

Modeling Electric Double Layer Effects on Charge Transfer at Flow Battery Electrode/Electrolyte Interfaces

The proposal aims to model interfacial processes associated with redox flow batteries (RFB) for grid/stationary storage, with the ultimate goal of helping design new electrolytes, electrodes, redox species, and interfaces. It addresses the linked problems of electric double layer (EDL) structure and electron transfer at model electrode/electrolyte interfaces. Fast electron transfer partly determines which redox species are viable for flow batteries (along with solubility, viscosity, etc.). Commercial systems apply aqueous, vanadium-based complexes, but other choices and organic electrolytes with larger voltage windows are the subject of active research at Sandia and elsewhere. The high salt concentration present in flow battery electrolytes yields non-trivial EDL consisting of solvents, counter-ions, co-ions, and redox species (at different charge states at the charging voltage threshold). EDL strongly influences electron transfer, especially when redox “mediators” are used. Modeling this key missing information is the main challenge. Our proposal seeks to apply Sandia’s LAMMPS molecular dynamics code. As a proof of principle, we study minimal model systems (graphite electrode, with ferrocene and fluornone as redox-active species). These model "catholyte" and "anolyte" molecules exhibit low reorganization energies (in the sense of Marcus theory) and are most amenable to EDL simulations which involve switching of redox states to mimic electron transfer. This study will enable future modeling and design of redox species relevant to flow batteries and redox mediators used at Sandia for other purposes.

25 ENERGY STORAGE↗

Physiological comparison of rat muscle in body suspension and weightlessness

Hind limb unloading is achieved with whole body suspension (WBS) and with tail suspension (TS). Comparable levels of muscle mass loss and decreases in protein levels result during one to three weeks of exposure to microgravity (microG), WBS, and TS. Losses are most apparent in soleus (S), intermediate in gastrocnemius (G) and least in extensor digigorum longus (EDL). Comparison of S and EDL type I and II fiber changes (numbers and area) after seven days of microG flight and WBS showed, in S, an increase in Type I and Type II fiber density and a decrease in area. Except for a decrease in Type I fiber density in EDL, all other parameters remained comparable. The general conclusions were that the S under microG and WBS responds in a similar manner. The EDL, for the most part, shows little change under both conditions.

Musacchia, X. J.↗

MGS and Odyssey - Relay Satellites for the MER Mission

Both Mars Global Surveyor (MGS) and Mars Odyssey are currently in low altitude, nearly circular and highly inclined orbits about Mars. Thus, they are available and compatible to serve as relay satellites for the Mars Exploration Rover (MER) mission. Consequently, the MER project developed requirements for MGS to be overhead, at a specific time with a 30 second tolerance, during the atmospheric entry, descent and landing (EDL) phase of both MER vehicles. The result, after execution of a single orbit synchronization maneuver (OSM) on 10/03/03, 92.4 days or 1130 orbits before Spirit's EDL, was that MGS was over Spirit 8 seconds past the required time. This maneuver, with a delta-velocity of 0.534 m/s, caused the orbital period to change by 3.34 s and resulted in a time-phasing change of 62 min 19 s in order to achieve the EDL overflight. Based on the navigation and execution of an OSM on 01/04/04, MGS was overhead for the Opportunity EDL on 01/25/04,3.5 seconds after the required epoch. Requirements also existed for the Odyssey over-flight of the MER rovers after landing and various equipment deployments had been completed. Thus, these requirements were that Odyssey should rise no earlier than specified times with respect to each of the landing sites. The Odyssey over-flights of both Spirit and Opportunity on sol 1 were equally successful. This paper will present the navigation plan, trajectory propagation accuracy and maneuver execution for the successful MGS and Odyssey over-flights of both the MER rovers.

Mars Global Surveyor (MGS)↗

Entry, Descent, and Landing Operations Analysis for the Mars Phoenix Lander

The Mars Phoenix lander was launched August 4, 2007 and remained in cruise for ten months before landing in the northern plains of Mars in May 2008. The one-month Entry, Descent, and Landing (EDL) operations phase prior to entry consisted of daily analyses, meetings, and decisions necessary to determine if trajectory correction maneuvers and environmental parameter updates to the spacecraft were required. An overview of the Phoenix EDL trajectory simulation and analysis that was performed during the EDL approach and operations phase is described in detail. The evolution of the Monte Carlo statistics and footprint ellipse during the final approach phase is also provided. The EDL operations effort accurately delivered the Phoenix lander to the desired landing region on May 25, 2008.

Prince, Jill L.↗

MARS Science Laboratory Post-Landing Location Estimation Using Post2 Trajectory Simulation

The Mars Science Laboratory (MSL) Curiosity rover landed safely on Mars August 5th, 2012 at 10:32 PDT, Earth Received Time. Immediately following touchdown confirmation, best estimates of position were calculated to assist in determining official MSL locations during entry, descent and landing (EDL). Additionally, estimated balance mass impact locations were provided and used to assess how predicted locations compared to actual locations. For MSL, the Program to Optimize Simulated Trajectories II (POST2) was the primary trajectory simulation tool used to predict and assess EDL performance from cruise stage separation through rover touchdown and descent stage impact. This POST2 simulation was used during MSL operations for EDL trajectory analyses in support of maneuver decisions and imaging MSL during EDL. This paper presents the simulation methodology used and results of pre/post-landing MSL location estimates and associated imagery from Mars Reconnaissance Orbiter s (MRO) High Resolution Imaging Science Experiment (HiRISE) camera. To generate these estimates, the MSL POST2 simulation nominal and Monte Carlo data, flight telemetry from onboard navigation, relay orbiter positions from MRO and Mars Odyssey and HiRISE generated digital elevation models (DEM) were utilized. A comparison of predicted rover and balance mass location estimations against actual locations are also presented.

Davis, J. L.↗

Reconstruction of the Mars Science Laboratory Parachute Performance and Comparison to the Descent Simulation

The Mars Science Laboratory used a single mortar-deployed disk-gap-band parachute of 21.35 m nominal diameter to assist in the landing of the Curiosity rover on the surface of Mars. The parachute system s performance on Mars has been reconstructed using data from the on-board inertial measurement unit, atmospheric models, and terrestrial measurements of the parachute system. In addition, the parachute performance results were compared against the end-to-end entry, descent, and landing (EDL) simulation created to design, develop, and operate the EDL system. Mortar performance was nominal. The time from mortar fire to suspension lines stretch (deployment) was 1.135 s, and the time from suspension lines stretch to first peak force (inflation) was 0.635 s. These times were slightly shorter than those used in the simulation. The reconstructed aerodynamic portion of the first peak force was 153.8 kN; the median value for this parameter from an 8,000-trial Monte Carlo simulation yielded a value of 175.4 kN - 14% higher than the reconstructed value. Aeroshell dynamics during the parachute phase of EDL were evaluated by examining the aeroshell rotation rate and rotational acceleration. The peak values of these parameters were 69.4 deg/s and 625 deg/sq s, respectively, which were well within the acceptable range. The EDL simulation was successful in predicting the aeroshell dynamics within reasonable bounds. The average total parachute force coefficient for Mach numbers below 0.6 was 0.624, which is close to the pre-flight model nominal drag coefficient of 0.615.

Cruz, Juan R.↗

Atmosphere Assessment for MARS Science Laboratory Entry, Descent and Landing Operations

On August 6, 2012, the Mars Science Laboratory rover, Curiosity, successfully landed on the surface of Mars. The Entry, Descent and Landing (EDL) sequence was designed using atmospheric conditions estimated from mesoscale numerical models. The models, developed by two independent organizations (Oregon State University and the Southwest Research Institute), were validated against observations at Mars from three prior years. In the weeks and days before entry, the MSL "Council of Atmospheres" (CoA), a group of atmospheric scientists and modelers, instrument experts and EDL simulation engineers, evaluated the latest Mars data from orbiting assets including the Mars Reconnaissance Orbiter's Mars Color Imager (MARCI) and Mars Climate Sounder (MCS), as well as Mars Odyssey's Thermal Emission Imaging System (THEMIS). The observations were compared to the mesoscale models developed for EDL performance simulation to determine if a spacecraft parameter update was necessary prior to entry. This paper summarizes the daily atmosphere observations and comparison to the performance simulation atmosphere models. Options to modify the atmosphere model in the simulation to compensate for atmosphere effects are also presented. Finally, a summary of the CoA decisions and recommendations to the MSL project in the days leading up to EDL is provided.

Cianciolo, Alicia D.↗