Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Double Beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Measurements of $\pi^-$ production in $^7$Be+$^9$Be collisions at beam momenta from 19$A$ to 150$A$GeV/$c$ in the NA61/SHINE experiment at the CERN SPS

The NA61/SHINE collaboration studies at the CERN Super Proton Synchrotron (SPS) the onset of deconfinement in hadronic matter by the measurement of particle production in collisions of nuclei with various sizes at a set of energies covering the SPS energy range. This paper presents results on inclusive double-differential spectra and mean multiplicities of $\pi^{-}$ mesons produced in the 5% most central $^7$Be + $^9$Be collisions at beam momenta of 19$A$, 30$A$, 40$A$, 75$A$ and 150$A$ GeV/$c$ obtained by the so-called $h^-$ method which does not require any particle identification. The shape of the transverse mass spectra differs from the shapes measured in central Pb + Pb collisions and inelastic p + p interactions. The normalized width of the rapidity distribution decreases with increasing collision energy and is in between the results for inelastic nucleon-nucleon and central Pb + Pb collisions. The mean multiplicity of pions per wounded nucleon in central $^7$Be + $^9$Be collisions is close to that in central Pb + Pb collisions up to 75$A$GeV/$c$. However, at the top SPS energy the result is close to the one for inelastic nucleon-nucleon interactions. The results are discussed in the context of predictions for the onset of deconfinement at the CERN SPS collision energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reducing heat load density with asymmetric and inclined double-crystal monochromators: principles and requirements revisited

Asymmetric double-crystal monochromators (aDCMs) and inclined DCMs (iDCMs) can significantly expand the X-ray beam footprint and consequently reduce the heat load density and gradient. Based on rigorous dynamical theory calculations, the major principles and properties of aDCMs and iDCMs are presented to guide their design and development, particularly for fourth-generation synchrotrons. In addition to the large beam footprint, aDCMs have very large bandwidths (up to ∼10 eV) and angular acceptance, but the narrow angular acceptance of the second crystal requires precise control of the relative orientations and strains. Based on Fourier coupled-wave diffraction theory calculations, it is rigorously proved that the iDCM has almost the same properties as the conventional symmetric DCM, including the efficiency, angular acceptance, bandwidth, tuning energy range and sensitivity to misalignment. The exception is that, for the extremely inclined geometry that can achieve very large footprint expansion, the iDCM has (beneficially) a larger bandwidth and wider angular acceptance. Inclined diffraction has the `rho-kick effect' that can be cancelled by the second reflection of the iDCM (even with misalignment), except that inhomogeneous strains may cause non-uniform rho-kick angles. At present, fabrication/mounting-induced strains pose low risk since they can be controlled to <0.5 µrad over large areas. The only uncertain challenge is the thermally induced strains, yet it is estimated that these strains are naturally lowered by the large footprint and may be further mitigated by optimized cryogenic cooling to the 1–2 µrad level. Overall, aDCMs and iDCMs have more stringent requirements than normal DCMs, but they are feasible schemes in practice.

asymmetric monochromator↗

Directed gas phase preparation of ethynylallene (H 2 CCCHCCH; X 1 A') via the crossed molecular beam reaction of the methylidyne radical (CH; X 2 Π) with vinylacetylene (H 2 CCHCCH; X 1 A')

The gas-phase bimolecular reaction of the methylidyne (CH; X 2 Π) radical with vinylacetylene (H 2 CCHCCH; X 1 A') was conducted at a collision energy of 20.3 kJ mol –1 under single collision conditions exploiting the crossed molecular beam experimental results merged with ab initio electronic structure calculations and ab initio molecular dynamics (AIMD) simulations. The laboratory data reveal that the bimolecular reaction proceeds barrierlessly via indirect scattering dynamics through long-lived C 5 H 5 reaction intermediate(s) ultimately dissociating to C 5 H 4 isomers along with atomic hydrogen with the latter predominantly originating from the vinylacetylene reactant as confirmed by the isotopic substitution experiments in the D1-methylidyne–vinylacetylene reaction. Combined with ab initio calculations of the potential energy surface (PES) and statistical Rice–Ramsperger–Kassel–Marcus (RRKM) calculations, the experimental determined reaction energy of –146 ± 26 kJ mol –1 along with the distribution minimum of T(θ) at 90° and isotopic substitution experiments suggest ethynylallene (p1; ΔrG = –230 ± 4 kJ mol –1 ) as the dominant product. The ethynylallene (p1) may be formed with extensive rovibrational excitation, which would result in a lower maximum translational energy. Further, AIMD simulations reveal that the reaction dynamics leads to p1 (ethynylallene, 75%) plus atomic hydrogen with the dominant initial complex being i1 formed by methylidyne radical addition to the double C[double bond, length as m-dash]C bond in vinylacetylene. Altogether, combining the crossed molecular beam experimental results with ab initio electronic structure calculations and ab initio molecular dynamics (AIMD) simulations, ethynylallene (p1) is expected to represent the dominant product in the reaction of the methylidyne (CH; X 2 Π) radical with vinylacetylene (H 2 CCHCCH; X 1 A').

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Diamagnetic-Loop-Based Beam Radius Monitor (BRM)

We describe a non-interceptive beam radius monitor that employs a diamagnetic loop. In order to increase the signal strength, the diamagnetic loop radius is considerably smaller than the outer wall radius, the device is placed inside a specially built solenoid magnet to allow independent adjustment of the guide magnetic field strength, and there are two counter-wound diamagnetic loops to double the signal strength and to eliminate common mode signals. This device is calibrated and the magnitude of the electron beam offset/tilt contribution to the measured radius estimated. This device is ready to be validated on an electron induction LINAC such a DARHT-I or DARHT-II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of ${\Xi \left( 1530\right) ^{0}} $ and ${\overline{\Xi }\left( 1530\right) ^{0}} $ production in proton–proton interactions at $\sqrt{s_{NN}}$ = 17.3 $\text{ GeV }$ in the NA61/SHINE experiment

Double-differential yields of ${\Xi \left( 1530\right) ^{0}} $ and ${\overline{\Xi }\left( 1530\right) ^{0}} $ resonances produced in p+p interactions were measured at a laboratory beam momentum of 158 $\text{ GeV }\!/\!c$. This measurement is the first of its kind in p+p interactions below LHC energies. It was performed at the CERN SPS by the NA61/SHINE collaboration. Double-differential distributions in rapidity and transverse momentum were obtained from a sample of $26\times 10^6$ inelastic events. The spectra are extrapolated to full phase space resulting in mean multiplicity of ${\Xi \left( 1530\right) ^{0}} $ ($6.73 \pm 0.25\pm 0.67)\times 10^{-4}$ and ${\overline{\Xi }\left( 1530\right) ^{0}} $ ($2.71 \pm 0.18\pm 0.18)\times 10^{-4}$. The rapidity and transverse momentum spectra and mean multiplicities were compared to predictions of string-hadronic and statistical model calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhancing Molecular Isotope Detection with a Chirp Tuned Optical Centrifuge

This paper gives a brief experimental overview on creating a chirp-tunable optical centrifuge with the goal of amplifying the isotope shift of a given molecule. Results for this experiment were recorded with a CO 2 plume as the probed material. Beyond amplification of the isotope shift, this technology could be modified to alter magnetic field characteristics of common molecules as well as simulating high temperature gases found in combustion environments. Our specific design uses double mirror and grating stretcher and will include a unique tuning feature for customization of the beam’s red and blue components' temporal chirp, allowing for quick reactivity to varying task requirements. The design and parameters will be discussed, as well as the methods used to model the optical centrifuge. Although this experiment is ongoing, results have been gathered previously that display the efficacy of the optical centrifuge. For the probed CO 2 sample, Raman Shifts centered around a wavenumber of 60 and 275 were recorded with durations of 1000 and 800 picoseconds, respectively.

47 OTHER INSTRUMENTATION↗

Coalescence, the thermal model and multi-fragmentation: the energy and volume dependence of light nuclei production in heavy ion collisions

Here, we present results of a phase space coalescence approach within the UrQMD transport and -hybrid model for a very wide range of beam energies from SIS to LHC. The coalescence model is able to qualitatively describe the whole range of experimental data with a fixed set of parameters. Some systematic deviations are observed for very low beam energies where the role of feed down from heavier nuclei and multi-fragmentation becomes relevant. The coalescence results are mostly very close to the thermal model fits. However, both the coalescence approach as well as thermal fits are struggling to simultaneously describe the triton multiplicities measured with the STAR and ALICE experiment. The double ratio of tp/d 2 , in the coalescence approach, is found to be essentially energy and centrality independent for collisions of heavy nuclei at beam energies of E lab > 10A GeV. On the other hand the clear scaling of the d/p 2 and t/p 3 ratios with the systems volume is broken for peripheral collisions, where a canonical treatment and finite size effects become more important.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation driven Hohlraum using 2 ω for ICF implosions at the NIF

Radiation flux symmetry in laser-irradiated Hohlraum environments is difficult to model and control and relies on the details of plasma evolution and laser energy deposition in the harsh plasma-filled Hohlraum over the duration of the laser pulse. This study presents a conceptual design and assesses the feasibility of using lasers to create a radiation drive where the implosion symmetry relies mainly on radiation transport. In this design, the ends of a capsule containing Hohlraum are irradiated by drive laser beams that are shielded from the view of the capsule. This configuration enables the use of frequency doubled light that has a higher power and energy threshold for the current capability of NIF, up to 670 TW and ∼3.5 MJ. We estimate, using VISRAD benchmarked against HYDRA calculations, that the same drive conditions that are currently being achieved in hybridE experiments at the NIF 270–290 at the equator can be reached in this new geometry and large 6.4 mm diameter Hohlraums. The radiation drive asymmetries in this design can be mitigated by shimming the capsule ablator thickness or through tailoring the shape of the shielding to the laser spots.

Kritcher, A. L. (ORCID:0000000296941088)↗

Monocrystalline 1.7-eV MgCdTe solar cells

Monocrystalline 1.7-eV Mg 0.13 Cd 0.87 Te/Mg x Cd 1-x Te (x > 0.13) double-heterostructure (DH) solar cells with varying Mg composition in the barrier layers are grown by molecular beam epitaxy. Furthermore, a Mg 0.13 Cd 0.87 Te/Mg 0.37 Cd 0.63 Te DH solar cell featuring abrupt interfaces between barriers and absorber and the addition of a SiO 2 anti-reflective coating demonstrates open-circuit voltage (V OC ), short-circuit current density (J SC ), fill factor (FF), and device active-area efficiencies up to 1.129 V, 17.3 mA/cm 2 , 77.7% and 15.2%, respectively. The V OC and FF vary oppositely with the Mg x Cd 1-x Te barrier height indicating an optimal design of the MgCdTe DHs as a tradeoff between carrier confinement and carrier transport. Temperature-dependent V OC measurements reveal the majority of carrier recombination in the devices occurs outside the DHs, in the a-Si:H hole-contact layer and at the interface between the a-Si:H layer and the Mg x Cd 1-x Te top barrier at room temperature. Simulation results for the device with the highest efficiency show that the p-type a-Si:H layer and Mg 0.37 Cd 0.63 Te top barrier contribute 1.3 mA/cm 2 and 2.4 mA/cm 2 J SC loss, respectively.

14 SOLAR ENERGY↗

Quantum gates on asynchronous atomic excitations

A method for realising a universal system of quantum gates based on asynchronous excitations of two-level atoms in optical cavities is proposed. The entangling operator of the CSign type is implemented without beam splitters, approximately, using the incommensurability of the Rabi oscillation periods in a cavity with single and double excitations. (quantum technology)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear rotation at the fission limit in Rf 254

A ground-state rotational band in the fissile nucleus Rf254 was observed for the first time. Levels up to spin 14 and excitation energy of 1.56 MeV were observed. The Rf254 nuclei were produced using the Pb206(Ti50,2n) fusion-evaporation reaction. It is the weakest reaction channel ever studied using in-beam γ-ray spectroscopic methods. The reaction products were separated from the beam in the Argonne gas-filled analyzer (AGFA). The Rf254 nuclei were implanted into a double-sided Si strip detector at the AGFA focal plane and tagged with subsequent ground-state spontaneous fission decays using temporal and spatial correlations. Prompt γ rays in coincidence with the Rf254 recoils were detected in the Gammasphere array of Ge detectors. In order to identify the ground-state rotational band in Rf254, a method for identifying rotational bands in low statistics γ-ray spectra was developed. The deduced Rf254 kinematic moment of inertia is smaller compared to neighboring even-even nuclei. This is most likely associated with a slightly lower quadrupole deformation and stronger pairing correlations in Rf254. The behavior of the moment of inertia as a function of rotational frequency is similar to that of the lighter N=150 isotones Fm250 and No252.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Inclusive photon production at forward rapidities in pp and p–Pb collisions at $\sqrt{{{s}}_{\textrm{NN}}}={5.02}$ TeV

A study of multiplicity and pseudorapidity distributions of inclusive photons measured in pp and p–Pb collisions at a center-of-mass energy per nucleon–nucleon collision of $\sqrt{s_{NN}}$ = 5.02 TeV using the ALICE detector in the forward pseudorapidity region 2.3 < η lab < 3.9 is presented. Measurements in p–Pb collisions are reported for two beam configurations in which the directions of the proton and lead ion beam were reversed. The pseudorapidity distributions in p–Pb collisions are obtained for seven centrality classes which are defined based on different event activity estimators, i.e., the charged-particle multiplicity measured at midrapidity as well as the energy deposited in a calorimeter at beam rapidity. The inclusive photon multiplicity distributions for both pp and p–Pb collisions are described by double negative binomial distributions. The pseudorapidity distributions of inclusive photons are compared to those of charged particles at midrapidity in pp collisions and for different centrality classes in p–Pb collisions. The results are compared to predictions from various Monte Carlo event generators. None of the generators considered in this paper reproduces the inclusive photon multiplicity distributions in the reported multiplicity range. The pseudorapidity distributions are, however, better described by the same generators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Neutron Electromagnetic Form Factor Ratio at High Momentum Transfer

The inner structure of the nucleon (proton and neutron) remains a topic of great interest in nuclear and particle physics, after many decades of study. For example, understanding the quark-gluon dynamics inside the nucleon would shed light on how 99% of the nucleon mass is created. The neutron electromagnetic form factors, Gn E and Gn M , give important insights into the neutron structure. The Super BigBite Spectrometer (SBS) program at Jefferson Lab (JLab) seeks to extend the form factor measurements for both the proton and the neutron. The neutron electric form actor, Gn E , has been historically difficult to measure due to the short lifetime of the free neutron and the small value of Gn E . The GEn-II experiment is part of the SBS program and seeks to measure Gn E , significantly increasing the high momentum transfer coverage. A newly designed polarized 3He target increased the figure of merit by three times compared to previous measurements. The analysis of this data is especially challenging due to the unprecedented high-rate environment caused by the open nature of the spectrometer with a direct line of sight to the target. This required developing new Gas Electron Multiplier (GEM) particle trackers which can cover large areas demanded by this setup and handle particle rates up to 500 kHz/cm2. Rates this high over a large area is unprecedented in particle tracking systems and came with a number of challenges. Data taken in the SBS program was critical to understanding hardware and software solutions that improved the track reconstruction efficiency to be >97% with a position resolution of 70 ?m. In previous experiments the proton electromagnetic form factors, Gp E and Gp M were measured up to Q2 = 8.5 GeV2 and Q2 = 30 GeV2, respectively, while Gn E has only been measured up to Q2 = 3.4 GeV2. The GEn-II experiment has measured the neutron form factor ratio, Gn E/Gn M, at Q2 values of 2.90, 6.50, and 9.47 GeV2 by scattering a polarized electron beam with a polarized 3He target, used here as an effective polarized neutron target, and measuring the double spin asymmetry of the cross section. Previous Gn E measurements do not extend above Q2 = 3.4 GeV2, and therefore this analysis has extended the world data by almost three times. The background correction is especially difficult at the higher Q2 settings leading to large systematic errors. As very exploratory results from this early analysis of the data, we find for Q2 = 2.90 GeV2, Gn E = 0.0157 ±stat 0.0016 ±sys 0.0011, for Q2 = 6.50 GeV2, Gn E = 0.0067 ±stat 0.0019 ±sys 0.0005, and for Q2 = 9.46 GeV2, Gn E = 0.0046 ±stat 0.0023 ±sys 0.0005. These results are compared to predictions from the Dyson-Schwinger Equations (DSE) model and a Relativistic Constituent Quark Model (RCQM).

Jeffas, Sean↗

Reducing beta functions in the NSLS-II long straight section for NEXT-III beamlines

The NSLS-II Experimental Tools III (NEXT-III) Project with the goal of building 8-12 new beamlines is ongoing. We were requested to explore the possibility of modifying the long straight section in Cell 26 to accommodate two new undulators for Advanced Nanoscale Imaging (ANI) Beamline and Tender X-ray Nanoprobe (TXN) Beamline. The scope of work includes: linear lattice matching; confirmation of the minimum ID gaps consistent with beam stay-clear limitations; calculation of the X-ray brightness; optimization of the dynamic aperture and momentum acceptance; multi-particle tracking to confirm the injection efficiency does not deteriorate significantly. The beam simulations have to be done using the most recent NSLS-II lattice model with all present insertion devices and realistic magnet errors, misalignments, and apertures. Originally two lattice options were considered for the assessment:1) with single -minimum beta functions and 2) NSLS-II with double-minimum beta functions. However, since the beamlines are not interested in the reduction of the horizontal beta function, just the vertical one, we decided to stop considering the single-minimum option because the current vertical beta is already low (3.3m) and further reducing it at the straight section center can increase it too much at the edge of a long ID, and limit the beam stay-clear. So, this report is focused on the double mini-beta scheme only.

43 PARTICLE ACCELERATORS↗

Design and Analysis of a Double Wall, Water Cooled Window for Accelerator Based Mo-99 Production

The electron accelerator based Mo-99 production technique requires the use of Rhodotrons to generate 38 MeV, 6.32 mA pulsed electron beams. The introduction of the pulsed beam structure has introduced fatigue concerns in the vacuum-helium windows that did not exist previously for electron beam production via linear accelerators. Previous analysis has shown that temperature fluctuations of approximately 100°C above and below the steady state operating temperature of ~500°C will occur within the windows. A water cooled window will eliminate this concern by reducing the primary mechanical stress due to the 300-psig helium pressure load as well as the secondary thermally induced stress. Although a water cooled window was considered years ago, the complexities of adding an additional water line was unattractive until now. A double wall, water cooled window has been designed and analyzed for this reason. The water cooled window design is shown to decrease the helium-side window temperature to as low as 125°C, while the vacuum-side window is maintained at 161°C at a water flow rate of 3.2 GPM. These low steady state temperatures reduce the thermal stress of the helium-side window significantly. Also, the primary mechanical stress has been reduced by roughly 50% due to the reduced pressure gradient across the helium-side window (150-psig water and 300-psig helium). Considering a Mo-99 production loss of roughly 1%, the water cooled window is a drastic improvement over the previous helium cooled designs and should be greatly considered for future upgrades and redesign.

43 PARTICLE ACCELERATORS↗

Measurement of T-Dependence of the Beam Asymmetry (S) for the Reaction yp --> n'p AT GLUEX

We report on a measurement of the four-momentum transfer (-t) dependence of the Beam Asymmetry (Sigma) for the reaction yp --> n'p with the linearly polarized photon beam at GlueX. The observable is sensitive to the n' production mechanism. The Beam Asymmetry (Sigma) was extracted from azimuthal angular distributions (phi) combined to obtain yield asymmetries. This technique removes most contributions from instrumental asymmetries. These data are based on a data set that is five times more extensive than previous measurements. This allowed us to double the kinematic reach in the four-momentum transfer squared (-t) and reduce the statistical uncertainties. Up to a four-momentum transfer squared (-t) of 1.7 GeV2, the beam asymmetry is positive, close to unity, and shows little dependence on the four-momentum transfer -t. This indicates that the production process continues to be dominated by exchanges of the rho (p) and the omega (w) mesons. Further systematic cross-check was done by analyzing the decay mode nr^0r^0. This analysis also revealed positive asymmetries closer to unity providing an important systematic cross-check for the results obtained using n'-->nr+r-.

Paudel, Churamani↗

Vacuum system design, construction, and operation for the Cornell High Energy Synchrotron Source upgrade

During the summer and fall 2018, the Cornell High Energy Synchrotron Source (CHESS), underwent an upgrade that recast the facility as primarily a low emittance X-ray source. The upgrade replaced one sixth of the Cornell Electron Storage Ring (CESR) with six double-bend achromats, featuring four novel CHESS Compact Undulator (CCU) insertion devices, and switched CESR to single particle beam operation. At the time of this writing, the upgraded storage ring has achieved the CHESS-U design goal of operating with 200 mA of positron current at 6.0 GeV beam energy. Additionally, seven out of eleven CHESS-U beamlines are currently in X-ray user operation. The construction and the commissioning of the new section of the CESR accelerator required novel solutions to design, fabrication, and vacuum system operations. Significant design considerations and efforts were made to minimize X-ray ‘dark-time’, returning to operation less than 1 year. This paper describes the important milestones of the process, the solutions implemented, and the present status of CHESS-U.

43 PARTICLE ACCELERATORS↗

Interlaboratory Reproducibility of Contour Method Data in a High Strength Aluminum Alloy

The contour method for residual stress measurement has seen significant development, but an experimental reproducibility study utilizing physical samples has not been published. A double-blind reproducibly study is reported, having scope beginning with EDM cutting and ending with residual stress calculation. A reinforced I-beam sample geometry is identified for its unique residual stress profile when extracted from residual stress bearing quenched aluminum bar (7050-T74). Contour measurements are prescribed on a midplane of symmetry with dimensions 24.0 mm by 50.0 mm. Fourteen identically prepared samples are fabricated from a single long bar with well characterized and uniform residual stress. Five samples throughout the bar are identified for planning measurements to validate sample uniformity and overall suitability of the residual stress field. The planning measurements employ a range of techniques: contour method, neutron diffraction, and hole-drilling. Eight samples are distributed to an international group of participants to execute their standard measurement practice. A double-blind process is followed to provide anonymity. Results are provided by eight participants: six being self-similar and two being quite different, the latter set aside as outliers. An average residual stress field is established from non-outlying results and the spatial distribution of reproducibility standard deviation is determined. The average stress field ranges from -60 to 70 MPa and the reproducibility standard deviation averages 8.1 MPa on the measurement plane. The average reproducibility standard deviation is about 3 × larger for points within 1.0 mm of plane boundaries (17.6 MPa) than for the remaining points (6.1 MPa). Reproducibility standard deviation (among different labs) for contour method residual stress measurement is found to be very similar to repeatability standard deviation (in a single lab) reported in prior work. The reproducibility observed here, for the entire measurement process, is also similar to that found in a prior reproducibility study limited to contour method data analysis.

36 MATERIALS SCIENCE↗