Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Oculometric Analysis of Saccadic Compensation for Visual Motion Processing Impairment due to Alcohol and Sleep Disruption

The Visuomotor Control Laboratory at Ames Research Center has developed a 5-minute ocular tracking test that computes 21 largely independent metrics of visuomotor performance, reflecting neural signal processing along a number of distinct pathways through cortex, brainstem, and cerebellum. Human sensorimotor performance is resilient to the challenges and stressors of many operational environments, in part, because overall performance is achieved through multiple parallel systems. Our multidimensional oculometrics allow us to examine impacts on these sub-components separately. To illustrate this, we contrasted the effects of two mild neural stressors, acute sleep-deprivation and low-dose alcohol. We have previously shown that, in both cases, oculometric analysis is a highly sensitive indicator of impairment. Here we quantified not only the observed impact on the performance of one sub-system, smooth pursuit, which uses high-level cortical processing of visual motion to track a moving object, but also the observed (partial) compensation by an evolutionarily older mid-brain and brainstem subsystem, saccades, which generates jumps in eye position to catch up with the target when smooth pursuit is inadequate. Specifically, we examined the dose-response (effect size vs. dose size) of the ground lost (pursuit deficit) and the ground recouped (saccadic compensation) across three separate studies – acute low-dose alcohol administration (16 subjects), acute sleep loss (12 subjects), and acute sleep loss with caffeine intervention (9 subjects). We computed the dose-response slopes using linear regression. The figure below shows that, in the case of acute sleep deprivation, the resulting slopes for ground lost and ground recouped (mean ± SE across subjects) were significantly different (paired t-test, t(11) = 5.17, p < 0.001), indicating poor saccadic compensation. However, when sleep loss was coupled with caffeine ingestion, ground lost was decreased and ground recouped increased such that the slopes were no longer different (t(8) = -0.05, p = 0.965). With alcohol, the two slopes were large albeit not significantly different (t(15) = 0.96, p = 0.351), indicating significant pursuit impairment but effective saccadic compensation. Our findings show that sleep deprivation and alcohol affect oculomotor performance differently. Low-dose alcohol effects appear predominantly cortical, with effective brainstem compensation. Sleep loss and circadian disruption however appears to affect both cortical and brainstem pathways with caffeine providing an effective countermeasure to both effects. Beyond the mere detection of impairment, our oculometric assessment allows us to characterize the nature of the deficit, to provide insight into the neural substrate, and to assess the effectiveness of countermeasures.

pursuit↗

Impact of Gender on Pharmocokinetics of Intranasal Scopolamine

Introduction: An intranasal gel dosage formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness (SMS), which is commonly experienced by astronauts during space missions. The bioavailability and pharmacokinetics (PK) were evaluated under IND guidelines. Since information is lacking on the effect of gender on the PK of Scopolamine, we examined gender differences in PK parameters of INSCOP at three dose levels of 0.1, 0.2 and 0.4 mg. Methods: Plasma scopolamine concentrations as a function of time data were collected from twelve normal healthy human subjects (6 male/6 female) who participated in a fully randomized double blind crossover study. The PK parameters were derived using WinNonlin. Covariate analysis of PK profiles was performed using NONMEN and statistically compared using a likelihood ratio test on the difference of objective function value (OFV). Statistical significance for covariate analysis was set at P<0.05(ΔOFV=3.84). Results: No significant difference in PK parameters between male and female subjects was observed with 0.1 and 0.2 mg doses. However, CL and Vd were significantly different between male and female subjects at the 0.4 mg dose. Results from population covariate modeling analysis indicate that a onecompartment PK model with first-order elimination rate offers best fit for describing INSCOP concentration-time profiles. The inclusion of sex as a covariate enhanced the model fitting (ΔOFV=-4.1) owing to the genderdependent CL and Vd differences after the 0.4 mg dose. Conclusion: Statistical modeling of scopolamine concentration-time data suggests gender-dependent pharmacokinetics of scopolamine at the high dose level of 0.4 mg. Clearance of the parent compound was significantly faster and the volume of distribution was significantly higher in males than in females, As a result, including gender as a covariate to the pharmacokinetic model of scopolamine offers the best fit for PK modeling of the drug at dose of 0.4 mg or higher.

Putcha, L.↗

Total Ionizing Dose Test of Analog Devices’ AD654 Voltage to Frequency Converter

Analog Devices’ AD654 was tested for total ionizing dose (TID) response beginning on February 13, 2017. This device has the Radiation Effects and Analysis Group Identification (REAG ID) number 16-036. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

B. Freeman↗

Total-dose radiation effects data for semiconductor devices, volume 3

Volume 3 of this three-volume set provides a detailed analysis of the data in Volumes 1 and 2, most of which was generated for the Galileo Orbiter Program in support of NASA space programs. Volume 1 includes total ionizing dose radiation test data on diodes, bipolar transistors, field effect transistors, and miscellaneous discrete solid-state devices. Volume 2 includes similar data on integrated circuits and a few large-scale integrated circuits. The data of Volumes 1 and 2 are combined in graphic format in Volume 3 to provide a comparison of radiation sensitivities of devices of a given type and different manufacturer, a comparison of multiple tests for a single data code, a comparison of multiple tests for a single lot, and a comparison of radiation sensitivities vs time (date codes). All data were generated using a steady-state 2.5-MeV electron source (Dynamitron) or a Cobalt-60 gamma ray source. The data that compose Volume 3 represent 26 different device types, 224 tests, and a total of 1040 devices. A comparison of the effects of steady-state electrons and Cobat-60 gamma rays is also presented.

Price, W. E.↗

ACRRF High-Bay Dose Calculations using MCNP (Part A)

Analytical tools and models have been developed as a starting point for directly assessing dose in the Annular Core Research Reactor Facility (ACRRF) due to reactor operation. Key results include peak dose along the Central Cavity (CC) centerline (beamline) at the cavity level, dose throughout the High-Bay (HB), and dose on the facility roof for partially-shielded reactor operation where the 4” insert is removed from the CC Shield Plug (SP). Model results in the beamline are benchmarked against measured doses from passive dosimetry evaluations. Personnel total (neutron and gamma) dose in the ACRRF HB is calculated using Monte Carlo N-Particle (MCNP). Various CC and SP configurations are analyzed, including unshielded (no SP) and partially shielded (SP installed but 4” insert removed). Novel application of Variance Reduction (VR) techniques, namely the Surface Source Write (SSW) and Surface Source Read (SSR) capabilities in MCNP, enable impressive resolution (in a Monte Carlo modeling sense) of dose throughout much the facility. The VR techniques reduce stochastic error for challenging tallies, with more advanced techniques explored in the companion to this report (Part B) [1]. Supplementary studies (including a verification analysis) and pedagogic evaluations in Part B involve neutron spectra, angular distributions, and the dose impact of facility characteristics. With the SP 4” insert removed and the Lead-Boron (44”) Bucket (LB–44) in the reactor cavity, Total Effective Dose (TED) within the CC beamline is ≈140 rem per 300 MJ of reactor yield (or 3900 rem per hour at 100% Steady-State (SS) power). With no SP (unshielded) and a Free-Field (FF) cavity, TED within the beamline is ≈610 rem per 300 MJ (or 17000 rem per hour at 100% SS power). Due to the predicted collimation of radiation by the reactor pool (and partial SP, if present), beamline dose is much greater than the scattered radiation field surrounding the cavity and reactor tank. Comparisons are made to beamline dosimetry measurements to validate the model. Model predictions agree reasonably well (⪅10%) with measured quantities of neutron fluence, gamma fluence, and spectral metrics. Away from the beamline, comparisons made to previous dose measurements in the HB agreement within an order of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation dosimetry measurements with real time radiation monitoring device (RRMD)-II in Space Shuttle STS-79

The real-time measurement of radiation environment was made with an improved real-time radiation monitoring device (RRMD)-II onboard Space Shuttle STS-79 (S/MM#4: 4th Shuttle MIR Mission, at an inclination angle of 51.6 degrees and an altitude of 250-400km) for 199 h during 17-25 September, 1996. The observation of the detector covered the linear energy transfer (LET) range of 3.5-6000 keV/micrometer. The Shuttle orbital profile in this mission was equivalent to that of the currently planned Space Station, and provided an opportunity to investigate variations in count rate and dose equivalent rate depending on altitude, longitude, and latitude in detail. Particle count rate and dose equivalent rate were mapped geographically during the mission. Based on the map of count rate, an analysis was made by dividing whole region into three regions: South Atlantic Anomaly (SAA) region, high latitude region and other regions. The averaged absorbed dose rate during the mission was 39.3 microGy/day for a LET range of 3.5-6000 keV/micrometer. The corresponding average dose equivalent rates during the mission are estimated to be 293 microSv/day with quality factors from International Commission on Radiological Protection (ICRP)-Pub. 60 and 270 microSv/day with quality factors from ICRP-Pub. 26. The effective quality factors for ICRP-Pub. 60 and 26 are 7.45 and 6.88, respectively. From the present data for particles of LET > 3.5keV/micrometer, we conclude that the average dose equivalent rate is dominated by the contribution of galactic cosmic ray (GCR) particles. The dose-detector depth dependence was also investigated.

manned↗

Worst Case Sabotage Consequence Modeling for Advanced Reactors

Under proposed rulemaking by the United States Nuclear Regulatory Commission, advanced reactor licensees may qualify for a reduction in onsite responders if the consequences from a sabotage attack do not exceed 25 rem at the reactor site boundary 2 hours after a release occurs. This work presents a preliminary assessment of the feasibility of meeting the 25 rem at the site boundary criteria. Using advanced reactor radionuclide inventories radiological release estimates created by collaborators at Oak Ridge National Laboratory, the MACCS consequence analysis code was used to investigate the distance at the dose from hypothetical sabotage events reaches 25 rem for different advanced reactor technologies. It was found that the distance to 25 rem depended heavily on sampled weather conditions and sabotage release fractions, and further refinement of release fractions and MACCS modeling parameters is recommended.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Historical Study of Radiation Exposures and the Incidence of Cataracts in Astronauts

For over 35 years, astronauts in low Earth orbit or on missions to the moon have been exposed to space radiation comprised of high-energy protons, heavy ions, and secondary neutrons. We reviewed the radiation exposures received by astronauts in space and on Earth, and presented results from the first epidemiological study of cataract incidence in the astronauts. Our data suggested an increased risk for cataracts from space radiation exposures. Using parametric survival analysis and the maximum likelihood method, we estimated the dose-response and age distribution for cataract incidence in astronauts by space radiation. Considering the high-LET dose contributions on specific space missions as well as data from animal studies with neutrons and heavy ions, suggested a linear response with no dose-threshold for cataracts. However, there are unanswered questions related to the importance and the definition of clinically significant cataracts commonly used in radiation protection, especially in light of epidemiological data suggesting that the probability that sub-clinical cataracts will progress is highly dependent on the age at which cataracts appear. We briefly describe a new study that will address the measurement of cataract progression-rates in astronauts and a ground-based comparison group.

Cucinotta, F. A.↗

Historical Study of Radiation Exposures and the Incidence of Cataracts in Astronauts

For over 35 years, astronauts in low Earth orbit or on missions to the moon have been exposed to space radiation comprised of high-energy protons, heavy ions, and secondary neutrons. We reviewed the radiation exposures received by astronauts in space and on Earth, and presented results from the first epidemiological study of cataract incidence in the astronauts. Our data suggested an increased risk for cataracts from space radiation exposures*. Using parametric survival analysis and the maximum likelihood method, we estimated the dose-response and age distribution for cataract incidence in astronauts by space radiation. Considering the high-LET dose contributions on specific space missions as well as data from animal studies with neutrons and heavy ions, suggested a linear response with no dose-threshold for cataracts. However, there are unanswered questions related to the importance and the definition of "clinically significant" cataracts commonly used in radiation protection, especially in light of epidemiological data suggesting that the probability that "sub-clinical" cataracts will progress is highly dependent on the age at which cataracts appear. We briefly describe a new study that will address the measurement of cataract progression-rates in astronauts and a ground-based comparison group.

Cucinotta, F. A.↗

Effects of gamma-Radiation on Select Lipids and Antioxidants

Radiation encountered on an extended duration space mission (estimates of 3 Sieverts for a mission to Mars) poses a threat not only to human health, but also to the quality, nutritional value, and palatability of the food system. Free radicals generated by radiation interaction with foods may initiate many unwanted reactions including: 1) autoxidation in lipids that alters flavor, odor, and concentrations of essential fatty acids, and 2) depletion of antioxidants food products and dietary supplements. Studies have shown that antioxidants may provide long term health protection from oxidative stress caused by radiation exposure; therefore, consumption of antioxidants will be important. Stability of essential fatty acids is also important for astronauts long-term health status. The objectives of this study were to characterize the effects of low dose gamma-radiation on lipids and antioxidants by monitoring oxidation and reducing power, respectively, in model systems. Select oils and antioxidants were exposed to levels of gamma-radiation ranging from 0 to 1000 Gy (1 Gy = 1 Sv) using a Gammacell 220 and stored at ambient or elevated temperatures (65 C) for up to 3 months prior to analysis. A Fricke dosimeter was used to verify differences between the radiation doses administered. Primary and secondary products of lipid oxidation in soybean and peanut oils were monitored using conjugated diene and 2-thiobarbituric acid (TBARs) assays. Changes in fatty acid composition and formation and vitamin E levels were also measured. The reducing power of antioxidant compounds, including vitamins C and E and beta-carotene, was determined using the ferric reducing antioxidant power (FRAP) assay. Significant differences (alpha =0.05) were present between all radiation doses tested using the Fricke dosimeter. Increasing radiation doses above 3 Sv resulted in significantly (alpha =0.05) elevated levels of oxidation and free fatty acids in soybean and peanut oils. Decreases in concentrations of essential fatty acids upon increasing radiation doses were also observed. Increasing radiation doses caused significant (alpha =0.05) decreases in reducing power and hence the effectiveness of vitamins C and E as well as beta-carotene. This work establishes a need for quantifying the effects of space relevant radiation doses in the development of a food system for an extended duration mission and for identifying threshold radiation levels that will impact the useful shelf-life of the variety of foods that will be sent. Eventual rancidity of lipids and the loss of antioxidant bioprotective effects are major concerns for the acceptability and nutritional profile of a food system.

Gandolph, Jacob↗

Flight Data Update on Long-Term Compound Stability in Dual Sorbent Tubes

Dual Sorbent Tubes (DSTs) are currently the primary method for collecting volatile organic compounds in the cabin air of the International Space Station (ISS). Data from groundbased analysis of these archival air samplers provide a major component of the assessment of ISS air quality by the NASA toxicologist. At the 2005 ICES conference data from the positive control DSTs, returned on Soyuz 7S and 8S, were presented. Positive control tubes are dosed, preflight, with known concentrations of representative contaminant compounds and they are launched to ISS in the DST kit as trip controls. Upon return of the DST kit to the ground, results from analysis of the trip (positive) and laboratory control tubes are used to determine the recoveries: concentration of dosed compounds retained in the tube. Results from positive controls, returned on 7S and 8S showed substantial losses of some compounds dosed into the tubes 156 to 240 days prior to the analysis. Low recoveries are expected for spacecraft air contaminants with similar properties to the poorly recovered dosed compounds. It was shown that compound losses in the control tubes were consistent, which led to the generation of acceptable correction factors for spacecraft air contaminants. Correction factors decrease the accuracy of derived compound concentrations and substantial error could arise under some conditions. An investigation into the mechanism for compound loss is necessary before design modifications can be implemented to improve the DST performance. This paper will update results from the DSTs returned on Soyuz 9S and 10S missions during the latter part of 2005. The data acquired from these returned DSTs will be compared to the 7S and 8S data presented last year. Discussion will focus on the reliability of correction factors and identify any trends in the data. This paper will describe the experimental design and plans to identify the compound loss mechanism.

James, John T.↗

Space radiation shielding analysis and dosimetry for the Space Shuttle program

Active and passive radiation dosimeters have been flown on every Space Shuttle mission to measure the naturally-occurring, background Van Allen and galactic cosmic radiation doses that astronauts and radiation-sensitive experiments and payloads receive. A review of the various models utilized at the NASA/Johnson Space Center, Radiation Analysis and Dosimetry is presented. An analytical shielding model of the Shuttle was developed as an engineering tool to aid in making premission radiation dose calculations and is discussed in detail. The anatomical man models are also discussed. A comparison between the onboard dosimeter measurements for the 24 Shuttle missions to date and the dose calculations using the radiation environment and shielding models is presented.

Atwell, William↗

Time-dependent oral absorption models

The plasma concentration-time profiles following oral administration of drugs are often irregular and cannot be interpreted easily with conventional models based on first- or zero-order absorption kinetics and lag time. Six new models were developed using a time-dependent absorption rate coefficient, ka(t), wherein the time dependency was varied to account for the dynamic processes such as changes in fluid absorption or secretion, in absorption surface area, and in motility with time, in the gastrointestinal tract. In the present study, the plasma concentration profiles of propranolol obtained in human subjects following oral dosing were analyzed using the newly derived models based on mass balance and compared with the conventional models. Nonlinear regression analysis indicated that the conventional compartment model including lag time (CLAG model) could not predict the rapid initial increase in plasma concentration after dosing and the predicted Cmax values were much lower than that observed. On the other hand, all models with the time-dependent absorption rate coefficient, ka(t), were superior to the CLAG model in predicting plasma concentration profiles. Based on Akaike's Information Criterion (AIC), the fluid absorption model without lag time (FA model) exhibited the best overall fit to the data. The two-phase model including lag time, TPLAG model was also found to be a good model judging from the values of sum of squares. This model also described the irregular profiles of plasma concentration with time and frequently predicted Cmax values satisfactorily. A comparison of the absorption rate profiles also suggested that the TPLAG model is better at prediction of irregular absorption kinetics than the FA model. In conclusion, the incorporation of a time-dependent absorption rate coefficient ka(t) allows the prediction of nonlinear absorption characteristics in a more reliable manner.

Non-NASA Center↗

Studies Relative to the Radiosensitivity of Man: Based on Retrospective Evaluations of Therapeutic and Accidental Total-Body Irradiation

The radiobiologic studies carried out with joint (AEC) ERDA and NASA support during the years 1964 to 1974 at the Medical Division of Oak Ridge Associated Universities are presented. The physiologic data generated were similar in many ways to those previously observed in other medical radiobiologic experiences. They differed, however, in the methods of data acquisition and analysis. Instead of more conventional analytical methods, pulmonary impedance was recorded and quantitated as a measure of radiation-induced gastrointestinal distress and fatiguability. While refinements in dose response related to gastrointestinal distress were accomplished, it was also found that through the use of Fourier analysis of pulmonary impedance waveform GI distress could easily be recognized and quantified even when the initial stages of nausea were below the subjects subjective level of recognition. The results demonstrate that change in pulmonary impedance waveform closely parallel well-defined stages of GI distress, i.e., initial nausea, a progressive increase in nausea, and finally vomiting episodes.

Ricks, R. C.↗

Mutagenic effects of a single and an exact number of alpha particles in mammalian cells

One of the main uncertainties in risk estimation for environmental radon exposure using lung cancer data from underground miners is the extrapolation from high- to low-dose exposure where multiple traversal is extremely rare. The biological effects of a single alpha particle are currently unknown. Using the recently available microbeam source at the Radiological Research Accelerator Facility at Columbia University, we examined the frequencies and molecular spectrum of S1- mutants induced in human-hamster hybrid (A(L)) cells by either a single or an exact number of alpha particles. Exponentially growing cells were stained briefly with a nontoxic concentration of Hoechst dye for image analysis, and the location of individual cells was computer-monitored. The nucleus of each cell was irradiated with either 1,2,4, or 8 alpha particles at a linear energy transfer of 90 keV/microm consistent with the energy spectrum of domestic radon exposure. Although single-particle traversal was only slightly cytotoxic to A(L) cells (survival fraction approximately 0.82), it was highly mutagenic, and the induced mutant fraction averaged 110 mutants per 10(5) survivors. In addition, both toxicity and mutant induction were dose-dependent. Multiplex PCR analysis of mutant DNA showed that the proportion of mutants with multilocus deletions increased with the number of particle traversals. These data provide direct evidence that a single a particle traversing a nucleus will have a high probability of resulting in a mutation and highlight the need for radiation protection at low doses.

NASA Discipline Radiation Health↗

Prediction of radiation damage effects in transistors

Quantative relationships between radiation dosage to transistors and resultant damage are established. Calculation of these dose levels is based on high energy particle population data and analysis of the shielding effect provided by the enclosures surrounding a given transistor.

Source record↗

Modeling Respiratory Toxicity of Authentic Lunar Dust

The lunar expeditions of the Apollo operations from the 60 s and early 70 s have generated awareness about lunar dust exposures and their implication towards future lunar explorations. Critical analyses on the reports from the Apollo crew members suggest that lunar dust is a mild respiratory and ocular irritant. Currently, NASA s space toxicology group is functioning with the Lunar Airborne Dust Toxicity Assessment Group (LADTAG) and the National Institute for Occupational Safety and Health (NIOSH) to investigate and examine toxic effects to the respiratory system of rats in order to establish permissible exposure levels (PELs) for human exposure to lunar dust. In collaboration with the space toxicology group, LADTAG and NIOSH the goal of the present research is to analyze dose-response curves from rat exposures seven and twenty-eight days after intrapharyngeal instillations, and model the response using BenchMark Dose Software (BMDS) from the Environmental Protection Agency (EPA). Via this analysis, the relative toxicities of three types of Apollo 14 lunar dust samples and two control dust samples, titanium dioxide (TiO2) and quartz will be determined. This will be executed for several toxicity endpoints such as cell counts and biochemical markers in bronchoaveolar lavage fluid (BALF) harvested from the rats.

Santana, Patricia A.↗

Dynamic Scaling Analysis of Accelerated Irradiation Testing on Additive Manufacturing Materials by Positron Annihilation

The timely applications of Additive Manufacturing (AM) materials in nuclear environments require accelerated irradiation tests, mainly ion irradiation to enable rapid prototyping. Low dose ion irradiation would cause sub-nanostructure changes by generation of lattice defects, vacancies, vacancy clusters and voids and void swelling caused by cellular dislocations. Positron Annihilation Lifetime (PAL), a novel technology, sensitive towards sub-nanostructure morphology with high accuracy (about 10-7 vacancy per atom), supported by Transition Electron Microscope (TEM) would be applied to identify the type and total size of the defects. The subsequent PAL measurements and TEM surface studies would be followed by PAL analysis that includes sophisticated trapping model. The PAS results would become an input to dynamic scaling analysis (that predicts radiation effects from low dose studies for high dose effects), which incorporate mean-field theory model. The final effect is an in-depth understanding of the microstructure evolution of AM materials under ion irradiation which can be extrapolated to the studies of neutron irradiation, since ion-irradiation takes less time and do not cause the irradiation hazard. The working hypothesis is that PAL technology, that have excellent sensitivity to low-defect concentration would help to identify ion-induced material damage on the atomic and nano-scale level, which then could be extrapolated to understand the neutron damage better.

accelerated irradiation testing↗