Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Differential operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Photoelectrode Durability in Two- versus Three-Electrode Configurations: Understanding the Impact of Circuit Configuration on Water-Splitting Stability

Device durability remains a significant challenge in photoelectrochemical (PEC) water splitting under ambient conditions. Yet, a lack of understanding of the test configuration and applied bias effects continue to hinder progress. In this study, we differentiate two-electrode (2E) and three-electrode (3E) configurations for evaluating PEC material durability, focusing particularly on their impacts on photoabsorber solid-state operating conditions. Our results underscore the fallacy of inferring 2E device stability from durability measurements performed solely in 3E configurations. Unmeasured and often misunderstood total circuit bias in 3E tests moderates material degradation, leading to the overestimation of photoelectrode stability compared to short-circuit operation. We demonstrate how the photoabsorber's operating voltage critically governs charge separation, surface stability, and degradation mechanisms during PEC operation. With these findings, we propose a standardized framework for conducting more reliable 3E durability experiments that simulate unassisted performance to help accelerate the development of robust, stable materials for solar-driven water splitting.

08 HYDROGEN↗

Quantum mechanical closure of partial differential equations with symmetries

We develop a statistical framework for the dynamical closure of spatiotemporal dynamics governed by partial differential equations. Employing the mathematical framework of quantum mechanics to embed the original classical dynamics into a quantum mechanical representation, we use the space of quantum density operators to model the unresolved degrees of freedom of the original dynamics in a statistical sense, and the framework of quantum measurement to predict their contributions to the resolved dynamics. The embedded dynamics is discretized by a positivity preserving process, leading to a compressed representation that is invariant under the dynamical symmetries of the resolved dynamics. We present a data based formulation of the closure scheme and apply it to a closure problem for the shallow water equations. The numerical results demonstrate that our closure model can accurately predict the main features of the true dynamics, including for out of sample initial conditions.

Delay embedding↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Massive right-handed neutrinos in $\bar{B} \to D^* τ\bar X$ decay

We explore signatures of a massive right-handed neutrino (RHN) in angular distributions of $\bar{B} \to D^* (\to D π) τ(\to πν_τ) \bar X$ decays, where $X$ is an invisible state. We assume the new physics is described by the standard model effective field theory extended with an RHN in the MeV-GeV mass range. We calculate for the first time the full differential distributions in terms of the visible final states, including the decay of the $τ$ lepton. We evaluate the sensitivity of various distributions to the new physics operators.

FOS: Physical sciences↗

Accelerating phase field simulations through a hybrid adaptive Fourier neural operator with U-net backbone

Prolonged contact between a corrosive liquid and metal alloys can cause progressive dealloying. For one such process as liquid-metal dealloying (LMD), phase field models have been developed to understand the mechanisms leading to complex morphologies. However, the LMD governing equations in these models often involve coupled non-linear partial differential equations (PDE), which are challenging to solve numerically. In particular, numerical stiffness in the PDEs requires an extremely refined time step size (on the order of 10 -12 s or smaller). This computational bottleneck is especially problematic when running LMD simulation until a late time horizon is required. This motivates the development of surrogate models capable of leaping forward in time, by skipping several consecutive time steps at-once. In this paper, we propose a U-shaped adaptive Fourier neural operator (U-AFNO), a machine learning (ML) based model inspired by recent advances in neural operator learning. U-AFNO employs U-Nets for extracting and reconstructing local features within the physical fields, and passes the latent space through a vision transformer (ViT) implemented in the Fourier space (AFNO). We use U-AFNOs to learn the dynamics of mapping the field at a current time step into a later time step. We also identify global quantities of interest (QoI) describing the corrosion process (e.g., the deformation of the liquid-metal interface, lost metal, etc.) and show that our proposed U-AFNO model is able to accurately predict the field dynamics, in spite of the chaotic nature of LMD. Most notably, our model reproduces the key microstructure statistics and QoIs with a level of accuracy on par with the high-fidelity numerical solver, while achieving a significant 11, 200 × speed-up on a high-resolution grid when comparing the computational expense per time step. Finally, we also investigate the opportunity of using hybrid simulations, in which we alternate forward leaps in time using the U-AFNO with high-fidelity time stepping. We demonstrate that while advantageous for some surrogate model design choices, our proposed U-AFNO model in fully auto-regressive settings consistently outperforms hybrid schemes.

36 MATERIALS SCIENCE↗

Performance Test of Mini LVDT - ELVIS

The Institute for Energy (IFE) Technology has been a pioneer in the development of Linear Variable Differential Transformers (LVDTs) for in-pile testing, deploying over 2,200 units in various reactor environments with less than a 10% failure rate after five years of operation. This report focuses on the performance testing of IFE’s Mini LVDT, a compact sensor ideal for material test reactor experiments. The Mini LVDT, with a limited range of +/- 1.5 mm, offers excellent performance comparable to larger LVDTs, making it valuable in space-constrained applications. The development of an Enhanced Linear Variable Intrinsic Sensor (ELVIS) with internal temperature monitoring capabilities represents a significant advancement, addressing the critical need for real-time, accurate measurements in high-radiation and high-temperature environments. Two ELVIS prototypes were evaluated in terms of both temperature and displacement, showcasing promising results, though challenges with noise during temperature measurements were identified. This report summarizes the rigorous testing performed at Idaho National Laboratory (INL) and highlights the potential applications of Mini LVDTs and ELVIS in nuclear and other high-precision industries.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of differential t-channel single top (anti)quark production cross-sections at 13 TeV with the ATLAS detector

The production of single top quarks and top antiquarks via the t-channel exchange of a virtual W boson is measured in proton-proton collisions at a centre-of-mass energy of 13 TeV at the Large Hadron Collider. The full Run 2 data sample recorded with the ATLAS detector in the years 2015–2018 is used, corresponding to an integrated luminosity of 140 fb−1. The absolute and normalised production cross-sections are measured differentially as a function of the transverse momentum and absolute rapidity of the top quark and top antiquark. In addition, the ratio of top quark to top antiquark production cross-sections is measured. The measured distributions are compared with next-to-leading-order quantum chromodynamics predictions obtained with different combinations of matrix-element generators, parton-shower programs and proton parton distribution functions, as well as to next-to-next-to-leading-order calculations. Overall, good agreement is observed between the measurements and the theoretical predictions. For most measured distributions, the sensitivity to differences between the predictions is limited by the systematic uncertainties in the measurement. The measured differential distributions are also interpreted in an effective field theory approach to constrain the Wilson-Coefficient CQq3,1$$ {C}_{Qq}^{3,1} $$ associated with a four-quark operator. The interpretation accounts for the effect of the selection efficiency, which is altered significantly by non-zero contributions from CQq3,1$$ {C}_{Qq}^{3,1} $$.

Aad, G↗

Commissioning of Extended Electron Beam Ion Source at Brookhaven National Laboratory

Here, the Extended Electron Beam Ion Source (EEBIS) has been installed and commissioned at Brookhaven National Laboratory (BNL) hadron accelerator complex in the spring of 2023. EEBIS has replaced its predecessor, RhicEBIS, which provided ions for BNL hadron facilities for over a decade since 2009. The motivations for the source upgrade are to provide higher intensities of the Au 32+ ion beam for the Relativistic Heavy Ion Collider (RHIC) and to provide of an intense source of polarized 3 He 2+ ions for the future Electron Ion Collider (EIC) at BNL. EEBIS is and will continue to be the primary source for a variety of different ion species for the NASA Space Radiation Laboratory (NSRL) at BNL. EEBIS utilizes two identical, two-meter-long unshielded 5T warm bore superconducting solenoids, and it is operated with electron beam current up to 10 A, providing a high-capacity ion traps to fulfill the requirement for high intensity ion beams. The upstream solenoid contains a “short ion trap” with a length of 95 cm, while the “long ion trap” with a length of 178 cm is located inside the downstream solenoid bore. The main features of EEBIS are: * A Gas injection and ionization cell equipped with a Lorenz pulse valve * High-capacity ZAO non-evaporable getter (NEG) custom linear pumping units * In situ apparatus for pumping speed measurements to monitor NEG activation and saturation * “External drift tube” construction with differential pumping stages to provide space for Lorentz pulse valve and 3 He high-field polarization cell * A Ba oxide electron gun cathode. The design of EEBIS as well as the results of its commissioning and first-year operation are presented and discussed.

43 PARTICLE ACCELERATORS↗

AgnosticStorageDynamics.jl

SAND2026-22949O AgnosticStorageDynamics.jl is a Julia software package for technology-agnostic energy storage dynamics. It provides a differentiable storage model with charge and discharge limits, efficiencies, standing losses, spill, unmet demand, and time-resolved energy state tracking. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Michelen Strofer, Carlos [Sandia National Lab. (SN↗

Online and Offline Analytical Techniques to Quantify Chloride Salts

This report serves as the deliverable for Milestone- M3FT-26AN080502017: Summary of Accomplishments for Online and Offline Analytical Qualification of Chloride Fuel Salts. The qualification of chloride fuel salts is a critical challenge for the development and deployment of molten salt reactors (MSRs), requiring precise control and verification of chemical and isotopic composition to ensure predictable neutronics, manageable radiological behavior, and safe plant operation. Currently, there is no universally accepted standard for fuel salt qualification, particularly for chloride-based systems, which underscores the need for robust, science-based analytical methodologies. This report presents a comprehensive evaluation of both online and offline techniques for quantifying chloride fuel salts, including multielectrode array voltammetry, differential thermal analysis (DTA) probes, inert gas fusion (IGF) analyzers, and gamma spectrometry using the Mirion NAIS-2x2 NaI(Tl) detector. The integration of these methods enables real-time monitoring of actinide concentrations, redox state, and thermophysical properties, as well as high-precision measurement of impurities and isotopic composition. The acquisition of advanced instruments such as the Bruker Leonardo G6 for IGF and the Mirion NaI detector enhances analytical capabilities, supporting the establishment of operational envelopes and impurity thresholds. These approaches provide essential data for neutronic impact evaluation, feedstock documentation, and compliance with nuclear safety standards. The methodologies developed and validated in this report lay the groundwork for future standardized protocols, bridging the gap between laboratory research and commercial reactor operation, and advancing the safe and efficient deployment of chloride-fueled MSRs.

Polke, Amber↗

Monitoring the long-term performance of organic redox flow battery by a distribution of relaxation time analysis

Organic redox flow batteries hold great promise as an energy storage technology, but their intricate chemistry makes them vulnerable to various degradation mechanisms. Monitoring this degradation is essential for identifying the limiting processes within the cells. Electrochemical impedance spectroscopy (EIS) offers a straightforward, in-situ method for measuring the total resistance of an operating cell. However, to pinpoint the limiting processes during long-term cycling, EIS data must be complemented by other techniques. Distribution of relaxation time (DRT) analysis is particularly effective for differentiating resistance components. Here, in this study, we perform a comprehensive analysis of resistance evolution and the separation of anode and cathode contributions during long-term cycling of a full cell employing 7,8-dihydroxyphenazine-2-sulfonic acid (DHPS) as the anolyte. Separate analyses of the DHPS anolyte and ferri-/ferrocyanide catholyte were conducted using a symmetric cell setup. The relaxation times derived from symmetric cells facilitate the identification of peaks in the DRT profiles from the full cell. Importantly, the DRT profiles indicate a correlation between the evolution of charge transfer resistance and the chemical degradation of DHPS. The methodologies and results outlined in this study offer significant insights for developing diagnostic tools applicable to other types of redox flow batteries.

Distribution of relaxation time↗

Asymptotic-preserving dynamical low-rank method for the stiff nonlinear Boltzmann equation

In kinetic theory, numerically solving the full Boltzmann equation is extremely expensive. This is because the Boltzmann collision operator involves a high-dimensional, nonlinear integral that must be evaluated at each spatial grid point and every time step. The challenge becomes even more pronounced in the fluid (strong collisionality) regime, where the collision operator exhibits strong stiffness, causing explicit time integrators to impose severe stability restrictions. In this paper, we propose addressing this problem through a dynamical low-rank (DLR) approximation. The resulting algorithm requires evaluating the Boltzmann collision operator only r 2 times, where r, the rank of the approximation, is much smaller than the number of spatial grid points. We propose a novel DLR integrator, called the XL integrator, which reduces the number of steps compared to the available alternatives (such as the projector splitting or basis update & Galerkin (BUG) integrator). For a class of problems including the Boltzmann collision operator which enjoys a separation property between physical and velocity space, we further propose a specialized version of the XL integrator, called the sXL integrator. This version requires solving only one differential equation to update the low-rank factors. Furthermore, the proposed low-rank schemes are asymptotic-preserving, meaning they can capture the asymptotic fluid limit in the case of strong collisionality. Our numerical experiments demonstrate the efficiency and accuracy of the proposed methods across a wide range of regimes, from non-stiff (kinetic) to stiff (fluid).

97 MATHEMATICS AND COMPUTING↗

Conductivity space isotherm behavior in quantum anomalous Hall devices

The quantum Hall effect (QHE) has enhanced accessibility to measure and disseminate electrical units, owed in part to the recently redefined International System of Units in 2019. Graphene remains one of the preferred options to realize the ohm despite the limitations of high magnetic fields to produce a robust QHE. Topological insulators, on the other hand, show promise in providing quantized resistance via the quantum anomalous Hall effect, a phenomenon that removes the need for magnetic fields during operation. To optimize future devices for metrological applications, it is important to gain a better understanding of magnetically doped topological insulators like Cr-doped bismuth antimony telluride. The application of differential conductivity space analyses offers a more sensitive way to analyze the data and distinguish between 2D and 3D transport behaviors. This is particularly important in thin films, where the transition between 2D and 3D behavior can be subtle. The ability to confidently determine the dimensionality of the transport is crucial for selecting appropriate theoretical models for future device optimization. Furthermore, this work identifies variable range hopping as the dominant transport mechanism in the 2D regime using a rigorous statistical analysis (via the Bayes factor). These elements assist in the understanding of microscopic processes that govern charge transport in these materials.

Tran, N. T. M. [National Inst. of Standards and Te↗

New Measurement of Electron Neutrino Interactions on Argon in MicroBooNE

MicroBooNE, located at the Fermi National Accelerator Laboratory, is an 85-tonne liquid argon time-projection chamber designed to study neutrinos from the Booster Neutrino Beam and Neutrinos at the Main Injector (NuMI) beam. Understanding neutrino-nucleon interactions is essential for improving the accuracy of neutrino event generators, which are critical for modelling neutrino behaviour and interpreting data from oscillation experiments. The NuMI beam's high electron neutrino flux relative to its muon neutrino flux makes it particularly suited to probe these interactions. This poster presents new single-differential cross-section measurements of charged-current electron-neutrino interactions on argon with protons and no pions in the final state. These results use data from NuMI beam operations in both neutrino and antineutrino modes. Cross sections are reported as functions of key kinematic observables, including electron energy, total visible energy, and the opening angle between the electron and leading proton. Interaction rates as a function of proton multiplicity are also shown. These results are compared to theoretical predictions generated by widely used neutrino event generators.

Barnard, Abbey G. [Oxford U.] (ORCID:0000000161171↗

Impact of Higher Fidelity Design Iterations on Critical System Criteria

Nuclear criticality experiments are effective at informing the performance of nuclear data libraries across many applications. This work explores the implications of refining critical experiment MCNP models from their low fidelity optimization phase to penultimate neutronic models. Specifically, this work is focused on two series of plutonium fueled experiments funded through internal programs at Los Alamos National Laboratory building off previous efforts under the EUCLID (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) collaboration. Thales, the first of the two collaborations, is a fast spectrum Ta-reflected plutonium experiment to support operations at PF-4. The second experiment are twin configurations designed to target the intermediate energy cross sections in 239 Pu. Motivation for this experiment stems from the PARallel Approach of Differential and InteGral Measurements (PARADIGM) collaboration which hopes to achieve a significant reduction in 239 Pu cross section uncertainties in the intermediate region.

97 MATHEMATICS AND COMPUTING↗

Deciphering Reaction Mechanisms of Molecular Proton Reduction Catalysts with Cyclic Voltammetry: Kinetic vs Thermodynamic Control

The kinetics and thermodynamics of elementary reaction steps involved in the catalytic reduction of protons to hydrogen define the reaction landscape for catalysis. The mechanisms can differ in the order of the elementary proton transfer, electron transfer, and bond-forming steps and can be further differentiated by the sites at which protons and electrons localize. Access to fully elucidated mechanistic, kinetic, and thermochemical details of molecular catalysts is crucial to facilitate the development of new catalysts that operate with optimal efficiency, selectivity, and durability. The mechanism by which a catalyst operates, as well as the kinetics and thermodynamics associated with the individual steps, can often be accessed through electroanalytical studies. Here, this Account details the application of cyclic voltammetry to interrogate reaction mechanisms and quantify the kinetics and thermodynamics of elementary reaction steps for a series of molecular catalysts that mediate electrochemical proton reduction. I distinguish the limiting scenarios wherein a catalyst operates under kinetic control vs thermodynamic control, with a focus on detecting how cyclic voltammetry features shift with proton source strength and concentration, as well as scan rate. For systems that operate under kinetic control, catalytic currents are observed at, or slightly positive toward, the formal potential for the redox process that triggers catalysis. Under thermodynamic control, catalytic responses shift as a function of the proton source pKa and effective pH of the solution. After drawing this distinction, we introduce the appropriate voltammetry experiments and accompanying analytical expressions for extracting key metrics from the data. To illustrate analytical strategies to quantify elementary reaction steps of catalysts operating under kinetic control, I describe our studies of proton reduction catalysts Co(dmgBF 2 ) 2 (CH 3 CN) 2 (dmgBF 2 = difluoroboryl-dimethylglyoxime) and [Ni(P 2 Ph N 2 Ph ) 2 ] 2+ (P 2 Ph N 2 Ph = 1,5-phenyl-3,7-phenyl-1,5-diaza-3,7-diphosphacyclooctane). Here, peak shift analysis, foot-of-the-wave analysis, and plateau current analysis are applied to data sets wherein voltammetric response are recorded as a function of catalyst concentration, proton source concentration, proton source strength, and scan rate to quantify rate constants for elementary proton transfer and bond-forming steps in a catalytic cycle. Further, the case study of [Ni(P 2 Ph N 2 Ph ) 2 ] 2+ illustrates how complementary spectroscopic methods can bolster the mechanistic assignment. Collectively, these two studies showcase how detailed mechanistic studies inform on rate-limiting elementary steps in catalysis and other key processes underpinning catalysis. Second, I present analytical strategies to interrogate catalysts operating under thermodynamic control, centered on the case study of [Ni II (P 2 Ph N 2 Bn ) 2 ] 2+ (P 2 Ph N 2 Bn = 1,5-dibenzyl-3,7-diphenyl-1,5-diaza-3,7-diphosphacyclooctane). Here, the application of nonaqueous Pourbaix theory to extract thermodynamic information is introduced, and the construction of a coupled Pourbaix diagram is detailed. This study identifies ligand-based protonation as the key process that places catalysis under thermodynamic control and influences the reaction mechanism. Together, the work detailed in this Account showcases the utility of electroanalytical methods to disentangle complex reaction mechanisms and extract key thermochemical and kinetic parameters for elementary steps of catalysis. Through detailed presentation of the key analytical expressions that underpin these analyses, this Account seeks to facilitate the adoption of cyclic voltammetry by the community to fully extract kinetic, thermochemical, and mechanistic information on electrochemical small-molecule activation.

catalysts↗

High-Voltage Sodium–Metal Batteries with Asymmetric Fluoroalkoxylated Organoborate Anion Chemistry

The high reactivity of sodium (Na) metal restricts its compatibility to ether-based electrolytes, while the poor oxidative stability of ethers precludes their coupling to high-voltage cathodes, fundamentally limiting the operating voltage and energy density of sodium–metal batteries (SMBs). We present here a coordination-asymmetry strategy to reconcile this thermodynamic mismatch by generating in situ an asymmetric fluoroalkoxylated organoborate anion, [FB(OCH(CF 3 ) 2 ) 3 ] − (BOF – ), via a Lewis acid–base adduct reaction in ether electrolyte. The asymmetric ligand architecture differentiates oxidative and fluorination pathways: oxidizable B–O moieties mediate controlled interfacial reconstruction, whereas the terminal B–F units supply fluorine for chemical passivation. This self-adaptive chemistry yields nanoscale, conformal, compositionally graded interphases: a boron-oxide/boron-oxycarbide-rich cathode-electrolyte interphase (CEI) that mitigates ether oxidation and a bilayered inorganic–organic solid–electrolyte interphase (SEI) that regulates Na deposition. The nanostructured interphases enable highly reversible Na plating/stripping with an average Coulombic efficiency (CE) of 99.98% and sustain stable 4.3 V operation of anode-free SMBs in oxidation-prone ether electrolytes. Furthermore, this work establishes asymmetric boron coordination as a molecular-level design principle for creating chemically adaptive interphases that overcome the redox asymmetry in energy-dense electrochemical systems.

Anions↗