Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Simulation of image detectors in radiology for determination of scatter-to-primary ratios using Monte Carlo radiation transport code MCNP/MCNPX

Purpose: The purpose of this study was to compare and validate three methods to simulate radiographic image detectors with the Monte Carlo software MCNP/MCNPX in a time efficient way. Methods: The first detector model was the standard semideterministic radiography tally, which has been used in previous image simulation studies. Next to the radiography tally two alternative stochastic detector models were developed: A perfect energy integrating detector and a detector based on the energy absorbed in the detector material. Validation of three image detector models was performed by comparing calculated scatter-to-primary ratios (SPRs) with the published and experimentally acquired SPR values. Results: For mammographic applications, SPRs computed with the radiography tally were up to 44% larger than the published results, while the SPRs computed with the perfect energy integrating detectors and the blur-free absorbed energy detector model were, on the average, 0.3% (ranging from -3% to 3%) and 0.4% (ranging from -5% to 5%) lower, respectively. For general radiography applications, the radiography tally overestimated the measured SPR by as much as 46%. The SPRs calculated with the perfect energy integrating detectors were, on the average, 4.7% (ranging from -5.3% to -4%) lower than the measured SPRs, whereas for the blur-free absorbed energy detector model, the calculated SPRs were, on the average, 1.3% (ranging from -0.1% to 2.4%) larger than the measured SPRs. Conclusions: For mammographic applications, both the perfect energy integrating detector model and the blur-free energy absorbing detector model can be used to simulate image detectors, whereas for conventional x-ray imaging using higher energies, the blur-free energy absorbing detector model is the most appropriate image detector model. The radiography tally overestimates the scattered part and should therefore not be used to simulate radiographic image detectors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

End-to-End Physics Event Classification with CMS Open Data: Applying Image-Based Deep Learning to Detector Data for the Direct Classification of Collision Events at the LHC

This paper describes the construction of novel end-to-end image-based classifiers that directly leverage low-level simulated detector data to discriminate signal and background processes in pp collision events at the Large Hadron Collider at CERN. To better understand what end-to-end classifiers are capable of learning from the data and to address a number of associated challenges, we distinguish the decay of the standard model Higgs boson into two photons from its leading background sources using high-fidelity simulated CMS Open Data. We demonstrate the ability of end-to-end classifiers to learn from the angular distribution of the photons recorded as electromagnetic showers, their intrinsic shapes, and the energy of their constituent hits, even when the underlying particles are not fully resolved, delivering a clear advantage in such cases over purely kinematics-based classifiers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploration of ion temperature profile measurements at JET using the upgraded neutron profile monitor

The neutron profile monitor (NPM), routinely used at the Joint European Torus for neutron emissivity profile measurements, consists of two fan-shaped arrays of collimators and each line of sight (LOS) is equipped with a NE213 liquid organic scintillator for simultaneous measurements of the 2.5 MeV and 14 MeV neutrons. A digital system developed in ENEA has replaced the analog acquisition electronics and now enables the NPM to perform spatially resolved neutron spectrometry by providing neutron pulse height spectra (PHS) for each LOS. However, the NPM was not originally designed as a spectrometer and, therefore, lacks several key features, such as detailed measurements of the detector response functions and the presence of detector stability monitors. We present a proof of principle of ion temperature profile measurements derived from the NPM PHS in high plasma current discharges using simulated detector response functions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The NEUT neutrino interaction simulation program library

Abstract is a neutrino–nucleus interaction simulation program library. It can be used to simulate interactions for neutrinos with between 100 MeV and a few TeV of energy. is also capable of simulating hadron interactions within a nucleus and is used to model nucleon decay and hadron–nucleus interactions for particle propagation in detector simulations. This article describes the range of interactions modelled and how each is implemented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-329: Tissue-Equivalent Phantom Materials for Neutron Dosimetry in Proton Therapy

Purpose: To characterize tissue equivalence of phantom materials in terms of secondary neutron production and dose deposition from neutrons produced in radiation therapy phantom materials in the context of proton therapy using Monte Carlo simulations and measurements. Methods: In order to study the influence of material choice on neutron production in therapeutic proton beams, Monte Carlo simulations using the Geant4 and MCNPX-PoliMi transport codes were performed to generate the neutron fields produced by protons of 155 and 200 MeV. A simple irradiation geometry was used to investigate the effect of different materials. The proton beams were stopped in slab phantoms to study the production of secondary neutrons. The investigated materials were water, Lucite, and tissue-equivalent phantom materials (CIRS Inc., Norfolk, VA). Neutron energy spectra and absorbed dose by neutrons and their secondary particles were scored. In addition, simulations were performed for reference tissues (ICRP/ICRU) to assess tissue equivalence with respect to neutron generation and transport. In order to benchmark the simulation results, measurements were performed with a system developed at the University of Michigan; organic liquid scintillators were used to detect the neutron emissions from the irradiation of tissue-equivalent materials. Additionally, the MPPost code was used to calculate the scintillator response from the MCNPX-PoliMi output. Results: The simulated energy spectra and depth dose curves of the neutrons produced in different phantom materials showed similar shape. The differences of spectra and fluences between all studied materials and reference tissues were well within the achievable precision of neutron dosimetry. The shape of the simulated detector response of the liquid scintillators agreed well with measurements on the proton beamline. Conclusion: Based on Geant4 and MCNPX-PoliMi simulations, the investigated materials appear to be suitable to study the production of neutrons in proton therapy. MC simulations were verified with neutron measurements in therapeutic proton beams. This work was funded in part by the ANDANTE grant of the European Commission in the 7th Framework Program.

07 ISOTOPE AND RADIATION SOURCES↗

Real-Time Xenon Sensor Analysis Report

Radiotracer release experiments were performed at the Nevada National Security Site in October 2022. The overall experiment was called the RElease ACTivity (REACT) experiment. Twenty-two real-time xenon sensors were deployed for each of four releases. Initial, quick-look analysis results were reported in December 2022. This report reviews the more comprehensive offline analysis effort that was conducted during the remainder of fiscal year 2023 by the Dynamic Networks venture. Improved energy stabilization routines were implemented along with an improved background subtraction routine compared to the original quicklook calculations. The relative detection efficiencies of all real-time sensors were examined. Finally, simulated detector response functions were coupled to two different meteorological models using the measured conditions for the final release (REACT-04) to compare simulated detections with measurements. While there is some agreement between the models and measured data on the detection locations and timing, there is less agreement on the magnitude of those detections. Future sensor and meteorological modeling work will be needed to improve the agreement and to examine the additional releases (REACT-01 through REACT-03).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity of NEXT-100 to neutrinoless double beta decay

NEXT-100 is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta (0νββ) decay of $^{136}$Xe. The detector possesses two features of great value for 0νββ searches: energy resolution better than 1% FWHM at the Q value of $^{136}$Xe and track reconstruction for the discrimination of signal and background events. This combination results in excellent sensitivity, as discussed in this paper. Material-screening measurements and a detailed Monte Carlo detector simulation predict a background rate for NEXT-100 of at most 4 × 10$^{–4}$ counts keV$^{–1}$ kg$^{–1}$ yr$^{–1}$. Furthermore, the detector will reach a sensitivity to the 0νββ-decay half-life of 2.8 × 10$^{25}$ years (90% CL) for an exposure of 100 kg·year, or 6.0 × 10$^{25}$ years after a run of 3 effective years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the neutrino-oxygen neutral current quasielastic cross section using the accelerator neutrino neutron interaction experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-doped water Cherenkov detector located on-axis to Fermilab’s Booster Neutrino Beam (BNB). ANNIE is uniquely positioned to perform high-statistics measurements of neutrino-nucleus interactions in water, benefiting from a large neutrino flux due to a short (100-meter) baseline. A central focus of ANNIE’s physics program is the measurement of both charged current (CC) and neutral current (NC) cross sections on water, including neutral current quasielastic (NCQE) and CC-inclusive channels. The NCQE measurement is particularly critical for constraining uncertainties in rare-event searches such as the Diffuse Supernova Neutrino Background (DSNB), where atmospheric $\nu$NCQE interactions constitute a significant and poorly constrained background. This dissertation presents a measurement of the flux-averaged neutrino-oxygen neutral current quasielastic ($\nu$NCQE) cross section using $2.573 \times 10^{20}$~POT of BNB exposure from the 2022 and 2023 beam years. The $\nu$NCQE interaction is identified through the primary $\gamma$-rays produced by nuclear de-excitation of the residual $^{15}$N$^*$ or $^{15}$O$^*$ nucleus following nucleon knockout from $^{16}$O. A dedicated Monte Carlo (MC) re-tuning campaign was conducted using an americium-beryllium (AmBe) calibration source, Michel electrons from stopped muons, and throughgoing dirt muons originating upstream of the detector. This multi-sample approach provided a wide-ranging $\mathcal{O}(\text{MeV})$--$\mathcal{O}(\text{GeV})$ dataset for tuning the simulated detector response, which was subsequently validated against AmBe neutron and Michel electron data for use in the $\nu$NCQE analysis. A dedicated laser calibration campaign was carried out to reduce timing uncertainties across the PMT system, enabling reconstruction of the BNB bunch substructure with sufficient resolution to serve as a background rejection tool. By selecting events in-time with individual neutrino bunches, beam-correlated $\nu$NCQE events are separated from diffuse and accelerator-induced backgrounds, notably skyshine neutrons and externally-originating events, that would otherwise dominate traditional charge-based selections within a small-scale, surface-level, short-baseline detector. A data-driven estimation of the skyshine neutron and external background rates was performed and incorporated into the systematic uncertainty budget. The flux-averaged $\nu$NCQE cross section on oxygen is measured to be $1.57 \pm 0.06\,(\text{stat.})$ $^{+0.91}_{-0.67}\,(\text{syst.})$ $\times 10^{-38}\ \text{cm}^{2}$. A full systematic budget is constructed by propagating uncertainties in the secondary hadronic interaction modeling, background cross section normalizations, detector response, neutrino flux, and the primary $\gamma$-ray emission probabilities from oxygen nuclear de-excitation. An idealized de-excitation model, constructed from existing measurements in the literature is developed to benchmark the predictions of the \textsc{GENIE} event generator. A comparison reveals that \textsc{GENIE} systematically overpredicts the primary $\gamma$-ray emission probability from oxygen de-excitation by a factor of $1.49\times$ for $E_\gamma > 6$~MeV and $3.07\times$ in the $3$--$6$~MeV band. This comparison motivates the dominant systematic uncertainty in this analysis, where a conservative uncertainty of $^{+39.9\%}_{-0\%}$ on the primary $\gamma$-ray signal prediction is assigned. The ANNIE result is consistent with and complementary to existing flux-averaged $\nu$NCQE cross section measurements from T2K and Super-Kamiokande, providing an independent measurement with a different detector, neutrino beam, and analysis methodology. Looking ahead, an upgrade to the ANNIE DAQ infrastructure enabling continuous extended readout will allow a complementary $\nu$NCQE neutron multiplicity measurement, directly relevant to constraining the NCQE background in DSNB searches, competitive with the recent T2K measurement at SK-Gd. The planned Super-SANDI upgrade, deploying a large Water-based Liquid Scintillator (WbLS) volume, will further extend ANNIE's reach to hadronic final states and exclusive NC channels, and enable joint measurements with liquid argon detectors sharing the BNB beamline ahead of DUNE and Hyper-Kamiokande.

Doran, Steven [Iowa State U.]↗

Effectiveness of denoising diffusion probabilistic models for fast and high-fidelity whole-event simulation in high-energy heavy-ion experiments

Artificial intelligence (AI) generative models, such as generative adversarial networks (GANs), variational autoencoders, and normalizing flows, have been widely used and studied as efficient alternatives for traditional scientific simulations. However, they have several drawbacks, including training instability and inability to cover the entire data distribution, especially for regions where data are rare. This is particularly challenging for whole-event, full-detector simulations in high-energy heavy-ion experiments, such as sPHENIX at the Relativistic Heavy Ion Collider and Large Hadron Collider experiments, where thousands of particles are produced per event and interact with the detector. This work investigates the effectiveness of denoising diffusion probabilistic models (DDPMs) as an AI-based generative surrogate model for the sPHENIX experiment that includes the heavy-ion event generation and response of the entire calorimeter stack. DDPM performance in sPHENIX simulation data is compared with a popular rival, GANs. Results show that both DDPMs and GANs can reproduce the data distribution where the examples are abundant (low-to-medium calorimeter energies). Nonetheless, DDPMs significantly outperform GANs, especially in high-energy regions where data are rare. Additionally, DDPMs exhibit superior stability compared to GANs. The results are consistent between both central and peripheral centrality heavy-ion collision events. Moreover, DDPMs offer a substantial speedup of approximately a factor of 100 compared to the traditional Geant4 simulation method.

42 ENGINEERING↗

The effect of breast compression on mass conspicuity in digital mammography

This study analyzed how the inherent quality of diagnostic information in digital mammography could be affected by breast compression. A digital mammography system was modeled using a Monte Carlo algorithm based on the Penelope program, which has been successfully used to model several medical imaging systems. First, the Monte Carlo program was validated against previous measurements and simulations. Once validated, the Monte Carlo software modeled a digital mammography system by tracking photons through a voxelized software breast phantom, containing anatomical structures and breast masses, and following photons until they were absorbed by a selenium-based flat-panel detector. Simulations were performed for two compression conditions (standard compression and 12.5% reduced compression) and three photon flux conditions (constant flux, constant detector signal, and constant glandular dose). The results showed that reduced compression led to higher scatter fractions, as expected. For the constant photon flux condition, decreased compression also reduced glandular dose. For constant glandular dose, the SdNR for a 4 cm breast was 0.60{+-}0.11 and 0.62{+-}0.11 under standard and reduced compressions, respectively. For the 6 cm case with constant glandular dose, the SdNR was 0.50{+-}0.11 and 0.49{+-}0.10 under standard and reduced compressions, respectively. The results suggest that if a particular imaging system can handle an approximately 10% increase in total tube output and 10% decrease in detector signal, breast compression can be reduced by about 12% in terms of breast thickness with little impact on image quality or dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reconstruction of stop quark mass at the LHC

The cascade mass reconstruction approach was applied to simulated production of the lightest stop quark at the LHC in the cascade decay g-tilde{yields}t-tilde{sub 1}t{yields}{chi}-tilde{sub 2}{sup 0}tt{yields}l-tilde{sub R}ltt{yields}{chi}-tilde{sub 1}{sup 0}lltt with top quarks decaying into hadrons. The stop quark mass was reconstructed assuming that the masses of gluino, slepton, and the two lightest neutralinos were reconstructed in advance. A data sample set for the SU3 model point containing 400 k supersymmetry events was generated which corresponded to an integrated luminosity of about 20 fb{sup -1} at 14 TeV. These events were passed through the AcerDET detector simulator, which parametrized the response of a generic LHC detector. The mass of the t-tilde{sub 1} was reconstructed with a precision of about 10%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving Detector Systematic Uncertainties Through Data-Driven Machine Learning

Detector simulation in liquid argon time projection chambers (LArTPCs) is a constant challenge. In particular the modeling of electrons response on wires is highly nontrivial. However, new machine learning techniques exist which can be leveraged to ameliorate these concerns. We present a novel methodology to attempt to learn from cosmic muon data in the ICARUS detector how reconstructed wire signals are influenced by features of the hits such as location, particle direction, angle relative to the wire plane, etc. A model can then be generated which can apply the learned mapping to Monte Carlo events to create a more data-like simulation sample. By creating such a sample we expect to reduce the systematic uncertainties at ICARUS due to our detector modeling.

Hausner, Harry [Fermilab] (ORCID:0000000188932280)↗

Improving Detector Systematic Uncertainties Through Data-Driven Machine Learning

Detector simulation in liquid argon time projection chambers (LArTPCs) is a constant challenge. In particular the modeling of electrons response on wires is highly nontrivial. However, new machine learning techniques exist which can be leveraged to ameliorate these concerns. We present a novel methodology to attempt to learn from cosmic muon data in the ICARUS detector how reconstructed wire signals are influenced by features of the hits such as location, particle direction, angle relative to the wire plane, etc. A model can then be generated which can apply the learned mapping to Monte Carlo events to create a more data-like simulation sample. By creating such a sample we expect to reduce the systematic uncertainties at ICARUS due to our detector modeling.

Hausner, Harry [Fermilab] (ORCID:0000000188932280)↗

Event structure and double helicity asymmetry in jet production from polarized p+p collisions at (sq rt) s = 200 GeV

We report on the event structure and double helicity asymmetry (A{sub LL}) of jet production in longitudinally polarized p+p collisions at {radical}s = 200 GeV. Photons and charged particles were measured by the PHENIX experiment at midrapidity |{eta}| < 0.35 with the requirement of a high-momentum (> 2 GeV/c) photon in the event. Event structure, such as multiplicity, p{sub T} density and thrust in the PHENIX acceptance, were measured and compared with the results from the pythia event generator and the geant detector simulation. The shape of jets and the underlying event were well reproduced at this collision energy. For the measurement of jet ALL, photons and charged particles were clustered with a seed-cone algorithm to obtain the cluster p{sub T} sum (p{sub T}{sup reco}). The effect of detector response and the underlying events on p{sub T}{sup reco} was evaluated with the simulation. The production rate of reconstructed jets is satisfactorily reproduced with the next-to-leading-order and perturbative quantum chromodynamics jet production cross section. For 4 < p{sub T}{sup reco} < 12 GeV/c with an average beam polarization of <P> = 49% we measured A{sub LL} = -0.0014 {+-} 0.0037{sup stat} at the lowest p{sub T}{sup reco} bin (4-5 GeV/c) and -0.0181 {+-} 0.0282{sup stat} at the highest p{sub T}{sup reco} bin (10-12 GeV/c) with a beam polarization scale error of 9.4% and a p{sub T} scale error of 10%. Jets in the measured p{sub T}{sup reco} range arise primarily from hard-scattered gluons with momentum fraction 0.02 < x < 0.3 according to pythia. The measured A{sub LL} is compared with predictions that assume various {Delta}G(x) distributions based on the Gluck-Reya-Stratmann-Vogelsang parameterization. The present result imposes the limit -1.1 < {integral}{sub 0.02}{sup 0.3}dx{Delta}G(x,{mu}{sup 2} = 1 GeV{sup 2}) < 0.4 at 95% confidence level or {integral}{sub 0.02}{sup 0.3}dx{Delta}G(x,{mu}2 = 1 GeV{sup 2}) < 0.5 at 99% confidence level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Developments in SRW Code and Sirepo Framework Supporting Simulation of Time-Dependent Coherent X-ray Scattering Experiments

Physical optics simulations for beamlines and experiments are essential for the effective use of synchrotron light source facilities such as NSLS-II at BNL. The SRW software package supports such source-to-detector simulations for coherent X-ray scattering and imaging experiments through its Python interface and Sirepo browser-based graphical user interface. This allows one to define custom sample models, assess the feasibility of an experiment, and estimate most appropriate beamline settings before using valuable beamtime. We discuss the recent use of general-purpose GPU resources and coherent mode decomposition algorithms in SRW to accelerate physical optics simulations with partially coherent X-rays. To illustrate these new capabilities, we describe simulations of typical time series of partially coherent scattering images used in X-ray Photon Correlation Spectroscopy (XPCS) experiments; aiming to characterize the nanoscale dynamics of a disordered sample, representing a solution of nanoparticles undergoing Brownian diffusion.

36 MATERIALS SCIENCE↗

A long path-length optical property measurement device for highly transparent detector media

Measurements of the optical properties of highly transparent liquids are necessary for large-scale detectors that seek to detect optical signatures in kiloton-scale or larger volumes. Detailed understanding of the attenuation and scattering properties of fill media is critical to the ability to accurately simulate detector performance, and yet is often unavailable until in-situ measurements can be performed. Moreover, in-situ measurements may rely on effective attenuation lengths or other approximations to characterize performance, rather than absolute measurements of attenuation and scattering. To better understand the optical properties of potential fill media and purification schemes, a system has been developed which provides simultaneous attenuation and differential scattering cross-section measurements for highly transparent liquids. This horizontal, adjustable path-length “long-arm” system provides excellent isolation from the atmosphere, a high degree of vibration insensitivity, and a simple and reliable method of calibration. Further, scattering measurements can be carried out simultaneously at ports along the beamline equipped with optics allowing the selection of scatter angle and polarization. This enables both reliable quantitative scatter measurements and phase-function separation. This system has been extensively tested using deionized (DI) water as a benchmark, and has demonstrated repeatable measurements of attenuation lengths exceeding 100 m and scattering lengths approaching 1 km.

47 OTHER INSTRUMENTATION↗

Long gravitational-wave transients and associated detection strategies for a network of terrestrial interferometers

Searches for gravitational waves (GWs) traditionally focus on persistent sources (e.g., pulsars or the stochastic background) or on transients sources (e.g., compact binary inspirals or core-collapse supernovae), which last for time scales of milliseconds to seconds. We explore the possibility of long GW transients with unknown waveforms lasting from many seconds to weeks. We propose a novel analysis technique to bridge the gap between short O(s)''burst'' analyses and persistent stochastic analyses. Our technique utilizes frequency-time maps of GW strain cross power between two spatially separated terrestrial GW detectors. The application of our cross power statistic to searches for GW transients is framed as a pattern recognition problem, and we discuss several pattern-recognition techniques. We demonstrate these techniques by recovering simulated GW signals in simulated detector noise. We also recover environmental noise artifacts, thereby demonstrating a novel technique for the identification of such artifacts in GW interferometers. We compare the efficiency of this framework to other techniques such as matched filtering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generalizing to new geometries with Geometry-Aware Autoregressive Models (GAAMs) for fast calorimeter simulation

Generation of simulated detector response to collision products is crucial to data analysis in particle physics, but computationally very expensive. One subdetector, the calorimeter, dominates the computational time due to the high granularity of its cells and complexity of the interactions. Generative models can provide more rapid sample production, but currently require significant effort to optimize performance for specific detector geometries, often requiring many models to describe the varying cell sizes and arrangements, without the ability to generalize to other geometries. Here, we develop a geometry-aware autoregressive model, which learns how the calorimeter response varies with geometry, and is capable of generating simulated responses to unseen geometries without additional training. The geometry-aware model outperforms a baseline unaware model by over 50% in several metrics such as the Wasserstein distance between the generated and the true distributions of key quantities which summarize the simulated response. A single geometry-aware model could replace the hundreds of generative models currently designed for calorimeter simulation by physicists analyzing data collected at the Large Hadron Collider. This proof-of-concept study motivates the design of a foundational model that will be a crucial tool for the study of future detectors, dramatically reducing the large upfront investment usually needed to develop generative calorimeter models.

47 OTHER INSTRUMENTATION↗