Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Detector efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Simulation of Fluid Flow and Collection Efficiency for a SEA Inc. Multi-Element Probe and Ice Crystal Detector Using GlennICE

Numerical simulation results of fluid flow and collection efficiency of the Science Engineering Associates Inc. Multi-Element Probe (Multiwire) and Ice Crystal Detector (ICD) are presented. Fluid flow simulations were conducted using NASA's FUN3D while collection efficiency simulations were conducted using NASA's LEWICE3D software and GlennICE software. For both probes, 3D unsteady flow results were time-averaged. Simulations were computed for free steam velocities ranging from 85 to 185 m/s and freestream total pressures of 44.8 and 93.1 kPa. Collection efficiency results were computed for four spherical particle diameter sizes of 5, 20, 50, and 100 µm. GlennICE collection efficiency results for the multiwire were compared with previously published collection efficiency values calculated using LEWICE3D. Numerical collection efficiency results for the Ice Crystal Detector are presented for the first time.

aircraft, icing, Computational Fluid Dynamics

Simulation of Fluid Flow and Collection Efficiency for a SEA Inc. Multi-Element Probe and Ice Crystal Detector Using GlennICE

Numerical simulation results of fluid flow and collection efficiency of the Science Engineering Associates Inc. Multi-Element Probe (Multiwire) and Ice Crystal Detector (ICD) are presented. Fluid flow simulations were conducted using NASA's FUN3D while collection efficiency simulations were conducted using NASA's LEWICE3D software and GlennICE software. For both probes, 3D unsteady flow results were time averaged. Simulations were computed for freestream velocities ranging from 85 to 185 m/s and freestream total pressures of 44.8 and 93.1 kPa. Collection efficiency results were computed for four spherical particle diameter sizes of 5, 20, 50, and 100 µm. GlennICE collection efficiency results for the multiwire were compared with previously published collection efficiency values calculated using LEWICE3D. Numerical collection efficiency results for the Ice Crystal Detector are presented for the first time.

aircraft, icing, Computational Fluid Dynamics

A Coincident CdTe Detector Array for Enhanced Nuclear Process Monitoring

Nuclear fuel cycle aqueous separation processes desire improved real-time material characterization and process monitoring techniques; gamma coincidence spectroscopy has the potential to meet this need in these high throughput and high radiation environments based on its ability to reduce background noise, thereby enhancing detection limits and improving isotopic identification accuracy. A detector array composed of three CdTe detectors was designed to surround a chemical processing pipe in a reprocessing facility and evaluate the feasibility of passively assaying the nuclear materials flowing though this measurement point. This array uses commercial off the shelf components that are radiation hard and highly efficiency at low energies relevant to actinide photon signatures. Detector efficiency characterizations, coincidence detection, and potential configuration improvements are presented here.

Good, Erin C.

Low Frequency 1/f Noise on QWIPs, nBn, and Superlattice Focal Plane Array

Noise Equivalent Difference Temperature (NE△T) is a standard performance metric for most infrared focal plane array (FPA) systems. The frequency bandwidth and range associated with NE△T is at high frequency and it does not describe the long time noise behavior or the very low frequency noise of the FPA. Very low frequency noise measurement requires data capture that takes longer time duration and sampling interval. This study investigates low frequency noise in QWIP, nBn and LWIR n-type Complementary Barrier Infrared Detector (CBIRD) FPAs. The corner frequencies are extracted from the power spectral density (PSD) as function of frequency. The peak wavelength, quantum efficiency of QWIP detector are 6.2 µm and 2 %, respectively. QWIP FPA has a mean NE△T ~ 25 mK at an operating temperature of 65 K and an integration time of 16 msec. The mean QWIP PSD plot shows a corner frequency of < 0.5 mHz. The nBn FPA with 4 µm cut off and quantum efficiency of 67 % has NE△T ~ 15.6 mK at an integration time ~ 7.52 msec and an operating temperature of 120 K. The nBn has corner frequency of > 50 mHz. Lastly the n-type CBIRD FPA with a 50% cutoff at 8.8 µm and quantum efficiency of ~ 50 % has an NE△T ~ 18.6 mK at an integration time of 1.86 msec and operating temperature 120 K. The superlattice FPA has a corner frequency ~ 10 mHz. The investigation of the tail on the NE△T histogram reveals that its origin is not accounted for entirely by the high noise current, but also it needs the inclusion of lower responsivity for some pixels.

Pepper, B.

Improved heavy-ion PID using scintillation light detector with neural network analysis: a Monte Carlo simulation study

The photon collection efficiency of gaseous scintillator detectors varies according to the position of the impinging charged particles in the medium that generates scintillation light. Thus, when impinging particles are distributed over a large area, the intrinsic photon-number resolution of the system is affected by a large variation. This work presents and discusses a method for adjusting the total number of detected photons to account for variation in the photon collection efficiency as a function of the position of the light source within the scintillating medium. The method was developed and validated by processing data from systematic simulation studies based on GEANT4 that model the response of the Energy Loss Optical Scintillation System (ELOSS) detector. The position of the charged particle is calculated using a deep neural network algorithm. This is accomplished by analyzing the distribution of scintillation light recorded by the array of photosensors. The estimated particle position is then used to calculate the correction factor and adjust the amount of captured light to account for variations in the photon collection efficiency. The neural network algorithm provides excellent tracking capabilities, achieving sub-millimeter position resolution and an angular resolution of 12 mrad, approaching the performance of traditional tracking detectors (e.g., drift chambers). The present method can be generalized to any optical scintillation system where the photon collection efficiency depends on the position of the impinging particle.

Heavy-ion detectors

A faint-object grism spectrograph with multiple slits and CCD detector

A high-efficiency spectrograph for research on faint astronomical objects has been successfully built and is in regular use on the Multiple-Mirror Telescope (MMT). It is equipped with a motorized multi-slit mechanism to allow simultaneous observations of several objects. The combination of high throughput, multiple object capability, and low-noise CCD detector has allowed routine work to be extended to objects of V magnitude 23 and fainter.

Geary, John C.

Radiation portal monitor data file format for comprehensive background radiation monitoring

Radiation portal monitors (RPMs) are widely used at border security checkpoints to detect the presence of radioactive materials in people, vehicles, and cargo. Typically, RPM detection systems consist of two pillars equipped with gamma and neutron detectors. To improve detection efficiency, RPMs employ techniques such as a limited energy window, dynamic alarm thresholds, and lead shielding. However, without continuous monitoring of background radiation, signal interpretation can be compromised, because environmental factors and mechanical failures can cause fluctuations. Here, we introduce a daily file format that logs gamma background and neutron background radiation levels continuously over a 24 h period; this format is different from traditional formats that record data only when the RPM is active or occupied. The approach enables RPM operators and analysts to (1) identify and diagnose malfunctioning components, (2) adjust system settings to account for dynamic environmental factors, and (3) use the recorded data to characterize outer space phenomena. Continuous background reporting is essential for identifying issues such as faulty connections, voltage divider failures, and errors in background updates. Continuous background reporting also enables the detection of external influences, including nearby X-ray scanners, temperature fluctuations, rainfall, cosmic radiation, and lunar phase changes. These data files are designed to be easily evaluated and parsed using common tools, and a quick review by an expert is often sufficient for problem diagnosis. We anticipate that continuous background radiation monitoring and these new strategies will significantly improve the accuracy and reliability of RPM systems, reducing the rate of false alarms and enhancing overall system performance.

Background radiation monitoring

Testing CP properties of the Higgs boson coupling to τ leptons with heterogeneous graphs

In this paper we explore the possibility of utilizing Deep Learning in measuring the CP properties of the coupling of Higgs boson to τ leptons at the High Luminosity Large Hadron Collider. We employ three Deep Learning (DL) networks, Multi-Layer Perceptron (MLP), Graph Convolution Network (GCN), and Graph Transformer Network (GTN) to enhance signal-to-background separation. The angle between τ lepton decay planes at the detector level is CP-sensitive observables, and we develop Heterogeneous Graphs that integrate diverse node and edge structures to incorporate the CP-sensitive observable efficiently. Using simplified detector simulations we estimate the reconstruction accuracy of the angle between τ lepton planes at the detector level, considering hadronic τ decay modes and standard model backgrounds. With $\sqrt{s}$ = 14 TeV and $\mathcal{L}$ = 100 fb -1 , MLP excludes CP mixing angles above 20° at 68% confidence level (CL), while GCN and GTN achieve exclusions at 90% CL and 95% CL, respectively. The networks also achieve a 3σ significance in excluding a pure CP-odd state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Optimization of Noise Performance of Low-Back Ground Detector Arrays

The performance of the 2k x 2k Teledyne H2RG detectors is key to the success of the JWST mission. For broadband imaging, where background limited sensitivity is quickly reached, the key parameter is the quantum efficiency of the detectors, which is, in general, very good. For near infrared spectroscopy and narrow band imaging, we cannot generally reach the back-round limit, so instrument sensitivity is directly dependent on the read noise of the detector. We have initiated a program to analyze the noise characteristics of the H2RG detectors, studying the correlations among the detector outputs and with the reference output, as well as the temporal correlations in a given detector section. Lasing the measured characteristics of the noise correlations, we can determine the optimal coefficients for the removal of correlated noise as a function of frequency. By using available reference sources and adding more frequent references, we have been able to reduce the noise by a factor of two. We find that the detectors have significantly lower noise that observed in prior tests, and can offer significant improvements in the performance of the JWST instruments. We will present the analysis and mitigation techniques, discuss prospects for further improvements with existing detectors, and describe considerations for improvements in next-generation detectors.

Rauscher, Bernard J.

Enhanced quantum efficiency of high-purity silicon imaging detectors by ultralow temperature surface modification using Sb doping

A low temperature process for Sb doping of silicon has been developed as a backsurface treatment for high-purity n-type imaging detectors. Molecular beam epitaxy (MBE) is used to achieve very high dopant incorporation in a thin, surface-confined layer. The growth temperature is kept below 450 °C for compatibility with Al-metallized devices. Imaging with MBE-modified 1kx1k charge coupled devices ((CCDs) operated in full depletion has been demonstrated. Dark current is comparable to the state-of-the-art process, which requires a high temperature step. Quantum efficiency is improved, especially in the UV, for thin doped layers placed closer to the backsurface. Near 100% internal quantum efficiency has been demonstrated in the ultraviolet for a CCD with a 1.5 nm silicon cap layer.

Nikzad, Shouleh

Enhanced quantum efficiency of high-purity silicon imaging detectors by ultralow temperature surface modification using Sb doping

A low temperature process for Sb doping of silicon has been developed as a backsurface treatment for high-purity n-type imaging detectors. Molecular beam epitaxy (MBE) is used to achieve very high dopant incorporation in a thin, surface-confined layer. The growth temperature is kept below 450 (deg)C for compatibility with Al-metallized devices. Imaging with MBE-modified 1kx1k charge coupled devices (CCDs) operated in full depletion has been demonstrated. Dark current is comparable to the state-of-the-art process, which requires a high temperature step. Quantum efficiency is improved, especially in the UV, for thin doped layers placed closer to the backsurface. Near 100% internal quantum efficiency has been demonstrated in the ultraviolet for a CCD with a 1.5 nm silicon cap layer.

charged coupled devices (CCDs)

Development Status of the KIPM Detector Consortium

A kinetic inductance phonon-mediated detector is a calorimeter that uses kinetic inductance detectors (KIDs) to read out phonon signals from the device substrate. We have established a consortium comprising university and national lab groups dedicated to advancing the state of the art in these detectors, with the ultimate goal of designing a detector with sub-eV threshold on energy deposited in the substrate, enabling searches for both light dark matter and low-energy neutrino interactions. This consortium brings together experts in KID design, phonon and quasi-particle dynamics, and noise modeling, along with specialized fabrication facilities, test platforms, and unique calibration capabilities. Recently, our consortium has demonstrated a resolution on energy absorbed by the sensor of 2.1 eV, the current record for phonon-sensitive KIDs. However, due to ∼ 1% phonon collection efficiency, the overall detector resolution was limited to 320 eV. Finally, the current focus of the consortium is modeling and improving the phonon collection efficiency and implementing low-T c superconductors, both of which serve to improve the overall energy resolution and threshold of the detectors.

Temples, Dylan J. [Fermi National Accelerator Labo

The SNAP 27 gamma radiation spectrum obtained with a Ge/Li/ detector

The pulse height distribution, obtained experimentally using a Ge(Li) detector, was employed to determine the photon emission rate characteristic of a PuO2 fuel source known as the SNAP 27 heat source. The selfshielding parameters of the photon emitter, the efficiency of the detector and the geometry of the experiment were utilized to determine the unscattered photon emission rate of the source and the unscattered flux spectrum at a certain specified distance from the source. For the scattered part of the flux spectrum a Monte Carlo technique was employed so that the total flux spectrum could be determined at any point in the radiation field. As a result of this work, a technique was developed to obtain the unfolded radiation spectrum of the SNAP 27 heat source.

Taherzadeh, M.

Detector Channel Combining Results from a High Photon Efficiency Optical Communications Link Test Bed

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) is developing a low cost, scalable, photon counting receiver prototype for space-to-ground optical communications links. The receiver is being tested in a test bed that emulates photon-starved space-to-ground optical communication links. The receiver uses an array of single-pixel fiber-coupled superconducting nanowire single-photon detectors. The receiver is designed to receive the high photon efficiency serially concatenated pulse position modulation (SCPPM) waveform specified in the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization Blue Book Standard. The optical receiver consists of an array of single-pixel superconducting nanowire detectors, analog phase shifters for channel alignment, digitizers for each detector channel, and digital processing of the received signal. An overview of the test bed and arrayed receiver system is given. Simulation and system characterization results are presented. The data rate increase of using a four-channel arrayed detector system over using one single pixel nanowire detector is characterized. Results indicate that a single-pixel detector is capable of receiving data at a rate of 40 Mbps and a four-channel arrayed detector system is capable of receiving data at a rate of 130 Mbps.

Downey, Jennifer N.

Detector Channel Combining Results from a High Photon Efficiency Optical Communications Link Test Bed

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) is developing a low cost, scalable, photon-counting receiver prototype for space-to-ground optical communications links. The receiver is being tested in a test bed that emulates photon-starved space-to-ground optical communication links. The receiver uses an array of single-pixel fiber-coupled superconducting nanowire single-photon detectors. The receiver is designed to receive the high photon efficiency serially concatenated pulse position modulation (SCPPM) waveform specified in the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization Blue Book Standard. The optical receiver consists of an array of single-pixel superconducting nanowire detectors, analog phase shifters for channel alignment, digitizers for each detector channel, and digital processing of the received signal. An overview of the test bed and arrayed receiver system is given. Simulation and system characterization results are presented. The data rate increase of using a four-channel arrayed detector system over using one single pixel nanowire detector is characterized. Results indicate that a single-pixel detector is capable of receiving data at a rate of 40 Mbps and a four-channel arrayed detector system is capable of receiving data at a rate of 130 Mbps.

Downey, Jennifer N.