Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Scheme for stabilising the phase and arrival time of ultrashort laser pulses in a coherent beam combining fibre system

An algorithm has been demonstrated for simultaneously measuring the phase and arrival time of optical pulses relative to pulses in a reference channel using one detector array. Based on this algorithm, a simple optoelectronic pulse phase and arrival time stabilisation scheme has been designed for operation in a coherent beam combining fibre system for ultrashort pulses (including chirped ones). We have studied the performance of the stabilisation scheme. In particular, we have reached a phase measurement rate of 25 000 cps, demonstrated an ∼ 2 kHz limiting phase stabilisation frequency in a feedback loop, and obtained an arrival time measurement accuracy of ∼ 5 % of the transform-limited pulse duration at a measurement rate of 5 cps. In experiments concerned with coherent beam combining for two channels of a pulsed fibre system at a wavelength of 1030 nm, we have demonstrated phase stabilisation with an accuracy better than λ/100 and delay setting accuracy of 10 fs at a transform-limited pulse duration of ∼ 200 fs and obtained 94 % beam combining efficiency. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Decade of GRETINA Science

High-resolution γ-ray detector arrays have driven many scientific advances and discoveries in nuclear physics. Today, they provide a powerful and essential tool for a broad class of measurements in the study of nuclear structure and reactions, nuclear astrophysics, and applied nuclear science. In this article, we present an overview of the scientific program that has been enabled by the γ-ray tracking array GRETINA [Pas13]. This program is being carried out at both stable and radioactive ion beam facilities, employs a wide range of beam energies and reactions (from the Coulomb barrier to more than 30% the speed of light), and reflects the varied application of a γ-ray tracking array.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of β -delayed proton emitters in the region of 100 Sn

An experiment on neutron-deficient nuclei in the region of doubly magic 100 Sn was carried out at the Radioactive Ion Beam Factory (RIBF) at the RIKEN Nishina Center in Japan. 𝑁 ≈ 𝑍 ≈ 50 nuclei were produced following fragmentation of an intense primary 124 Xe beam and implanted in the Advanced Implantation Detector Array silicon setup for the first study of proton-rich nuclei with this system at RIKEN. Measurements of the 𝛽-delayed proton emitter decay half-lives, branching ratios and proton energy spectra of nuclei in the region of 100 Sn were performed, with improved precision in many cases. New results for the energy spectrum of 101 Sn are presented, where a 2.03(5)-MeV peak was observed. In conclusion, these results are compared to shell-model calculations, using the recent precise measurement of the 101 In proton separation energy are presented.

Appleton, C. J. [Univ. of Edinburgh, Scotland (Uni↗

3 He +𝛼 resonances in 7 Be

Resonances in 7 Be which decay into the 3 He+α exit channel have been measured with improved precision using preexisting data sets. The energy and width of the J π =7/2 - state have been extracted from an invariant-mass study of projectile-breakup products originating from interactions of an E/A=10.7-MeV 10 C beam on Be and C targets. The excitation energy of this state (from the pole of the S-matrix) is determined to be E*=4.545(6)~MeV, a factor of 8 improvement in precision as compared to the ENSDF value. This improvement is enabled by fine tuning the detector calibrations using calibration resonances in 6 Li, 7 Li, 6 Be, 9 B, and 12 C whose decay energies are known to high precision. The J π =7/2- resonance in 7 Be can now itself be used as a calibration resonance in invariant-mass experiments. This utility is particularly helpful for 3 He energy calibrations of CsI(Tl) detectors which are often used in detector arrays employed for measurements with fast beams. This utility is demonstrated with a data set associated with E/A=70 MeV 7 Be beams which are inelastically excited to the 7/2 - and 5/2 - 1 resonances. Again using the pole of the S-matrix as the definition of the resonance parameters, the fitted excitation energy of the 5/2 - 1 resonance is 6.376(17) MeV, approximately 300 keV lower than the ENSDF value. Finally, its width of 565(4) keV is roughly half of the ENSDF value.

energy levels↗

Evolution of collective and noncollective structures in 123 Xe

An experiment involving a heavy-ion-induced fusion-evaporation reaction was carried out where high-spin states of 123 Xe were populated in the 80 Se( 48 Ca,5n) 123 Xe reaction at 207 MeV beam energy. Gamma-ray coincidence events were recorded with the Gammasphere Ge detector array. The previously known level scheme was confirmed and enhanced with the addition of five new band structures and several interband transitions. Furthermore, cranked Nilsson-Strutinsky (CNS) calculations were performed and compared with the experimental results in order to assign configurations to the bands.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Onset of high-spin rotational bands in the $N = Z$ nucleus 62 Ga

The fusion-evaporation reaction 28 Si + 40 Ca at 122 MeV beam energy was used to populate high-spin states in the odd-odd $N = Z$ nucleus 62 Ga. With the combination of the Gammasphere spectrometer and the Microball CsI(Tl) charged-particle detector array the decay scheme of 62 Ga was extended beyond 10 MeV excitation energy. The onset of band structures was observed. These high-spin rotational states are interpreted and classified by means of cranked Nilsson-Strutinsky calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structure of Nd 155 and Gd 163 from Cf 252 spontaneous fission

Background: A puzzle has arisen recently caused by the apparent shift in maximum deformation from the expected 66 Dy isotopic chain to the Nd 60 isotopic chain in the 82 155 Nd and 163 Gd, useful for constraining parameters in models that seek to answer the six proton shift in maximum deformation. Method: Data from the spontaneous fission of 252 Cf were taken by the Gammasphere detector array at Lawrence Berkeley National Laboratory to observe the excited states of 155 Nd and 163 Gd. Results: The structure of 163 Gd has been expanded with the addition of two new levels and three new γ rays, which are found to be consistent with previously published calculations and the structure of 165 Dy. In 155 Nd, nine new levels and 12 new γ rays are observed. The spins and parities of the previously known levels in 155 Nd have been reassigned from a ν3/2 - [521] ground state configuration to a ν5/2 + [642] isomeric configuration by comparison of these newly observed levels with levels in 153 Nd and 155 Sm. Conclusion: Further experimentation is required to determine the energy of the newly reassigned ν5/2+[642] level in 155 Nd with respect to the suspected ν3/2-[521] ground state. Additionally, more experiments should be conducted to further determine the structure of neutron rich nuclei, rarely produced in the spontaneous fission of 252 Cf, such as 163 Gd.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intrinsic electric quadrupole moment of the K π = 8 - isomeric state in Hf 178

The lifetime of the 9 - state in the rotational band based on the 4.0 s, K π = 8 - , isomeric state ( 178 Hf m 1 ) from the decay of the 31-yr isomer ( 178 Hf m 2 ) was determined to be 99(2) ps by means of the fast-timing technique using two LaBr 3 (Ce) scintillators. The δ (E2/M1) mixing ratios of the ΔI = 1 γ rays depopulating levels in this band were deduced from γ-γ angular correlations by using a 178 Hf m 2 radioactive source located at the center of the Gammasphere HPGe detector array. The new results, together with previous spectroscopic information, provide a different way to extract the intrinsic quadrupole moment of Q 0 = 6.45 (14) eb for the 178 Hf m 1 band. A possible explanation for the reduction of the 178 Hf m 1 nuclear charge radius is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First measurement of proton decay from a transfer reaction to 21 Na

Decay protons from excited states in Na 21 populated through a previously reported Mg 24 ( p , α ) Na 21 transfer reaction [Cha et al. , Phys. Rev. C 96 , 025810 (2017) ] were analyzed to extract the proton branching ratios of the energy levels. Additionally, by utilizing 31-MeV proton beams from the Holifield Radioactive Ion Beam Facility of Oak Ridge National Laboratory and isotopically enriched Mg 24 solid targets, the decay protons were detected in coincidence with α particles from the ( p , α ) reaction using a silicon strip detector array. Proton decay branching ratios of several Na 21 levels were deduced for the p 0 and p 1 decay channels to the ground and first excited states in Ne 20 , respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Correlated $\ n-γ$ angular distributions from the $\ Q$ = 4.4398 MeV 12 C ($\ n, n' γ$) reaction for incident neutron energies from 6.5 MeV to 16.5 MeV

Neutron scattering cross sections and angular distributions represent one of the most glaring sources of uncertainty in calculations of nuclear systems. Even simple nuclei like 12 C show indications of errors in nuclear databases for scattering reactions. Measurements of inelastic neutron scattering have historically measured either the scattered neutrons or the nuclear deexcitation $\ γ$ emission. Only a very small number of experiments attempted correlated measurements of both the neutron and $\ γ$ data simultaneously, even though these $\ n-γ$ correlations could be essential for understanding particle transport in nuclear systems. In this work we describe a measurement of the $\ n, γ$, and correlated $\ n-γ$ angular distributions from the $\ Q$ = 4.4398 MeV 12 C ($\ n, n'γ$) reaction in a single experiment using an EJ-309 liquid scintillator detector array with wide angular coverage, and with a continuous incident neutron energy range from 6.5 to 16.5 MeV. We also provide a thorough covariance description of these results, including normalization of the probability distribution. While the measured n distributions agree well with the relatively large number of available literature measurements, there are comparatively very few measurements of the γ distributions from this reaction. However, our data support the presence of a nonzero α 4 Legendre polynomial component of the γ angular distribution suggested in past measurements, which is currently not incorporated in the ENDF/B-VIII.0 library despite the use of these same literature data for evaluation of the 12 C ($\ n, n'γ$) cross section. The correlated $\ n-γ$ distribution measurements are limited to three measurements at incident neutron energies near 14 MeV. Our results do not generally agree with any of these literature measurements. We observe clear indications of significant changes in the $\ n$ distribution for specific $\ γ$-detection angles and vice versa especially near thresholds for other reaction channels, which shows the potential for significant bias in experiments that, for example, tag on inelastic scattering using a single or small number of $\ γ$ -detection angles and could impact particle transport calculations.

6 ≤ A ≤ 19↗

Determination of β -decay feeding patterns of 88 Rb and 88 Kr using the Modular Total Absorption Spectrometer at ORNL HRIBF

We report precise determination of ground-state feeding in the β decay of fission products is an important but challenging component in modeling reactor antineutrino flux and reactor decay heat. The Modular Total Absorption Spectrometer (MTAS) is a versatile NaI(Tl) detector array that determines the true β-decay pattern free from the pandemonium effect, including precise ground-state feeding intensities. In this paper, we report MTAS results of the β feeding intensities of 88 Rb and 88 Kr, fission products with large cumulative yields in nuclear reactors. By comparing MTAS results with previous measurements, 88 Rb provides a validation of MTAS's ability to determine ground-state feedings in β decays, while the precision of 88 Kr ground-state feeding is improved when compared with the Evaluated Nuclear Structure Data File (ENSDF). The investigation of sources that contribute to β feeding branching uncertainties in MTAS experiments is discussed in detail. Lastly, the deconvolution of 88 Rb decay spectra suggests that MTAS can distinguish an allowed β spectral shape from a first forbidden unique β spectral shape.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigating the time dependence of neutron-proton equilibration using molecular dynamics simulations

Neutron-proton equilibration has previously been studied experimentally in dynamically deformed nuclei in heavy ion collisions [Phys. Rev. Lett. 118, 062501 (2017); Phys. Rev. C 95, 044604 (2017)] using the NIMROD detector array at the Cyclotron Institute at Texas A&M University. Results indicated the composition of the two heaviest fragments originating from the excited projectile-like fragment evolved exponential with respect to their orientation angle to be more similar. Constrained Molecular Dynamics and Antisymmetrized Molecular Dynamics simulations were performed for different formulations of the density dependence of the asymmetry energy term of the nuclear equation of state. The simulations are compared to experimental results, which indicate a better agreement with a softer interaction in the nuclear equation of state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the cross section of the Q=4.4398 MeV 12 C (n, n'γ) reaction from threshold to 16.5 MeV using γ and correlated n–γ detection

The Q=4.4398 MeV 12 C (n, n'γ) cross section was measured using a white incident neutron source through the detection of γ rays only and n–γ coincidences using a segmented liquid scintillator detector array. While the n–γ technique utilized here is more generally applicable to a wide variety of neutron scattering measurements, the γ-only technique was successfully applied to this reaction to exploit the precise time resolution and high efficiency of this detection system to yield results with unprecedented statistical precision and total uncertainties < 2 % from reaction threshold up to 16 MeV incident neutron energy, clearly resolving many features in this reaction that were previously not well known. The γ-only and n–γ results are consistent with each other for the majority of the incident energy range covered in this paper, thereby lending validation to the n–γ technique for future measurements, though significant disagreements are observed between both results and with the ENDF/B-VIII.0 nuclear data evaluation. These differences are particularly noticeable in the recently evaluated energy range below 6.5 MeV, and also near 14 MeV where a “sawtooth”-like feature is observed similar to that in other 12 C+n reaction channels. Finally, both γ-only and n–γ results are presented here with thorough covariance derivations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using DAPPER to extract the photon strength function of 58 Fe using the inverse Oslo and shape methods

The photon strength function of 58 Fe has been extracted using both the Oslo and Shape methods from particle–γ coincidence data measured using the Detector Array for Photons, Protons, and Exotic Residues, which probes nuclei utilizing (d,p) reactions in inverse kinematics. Four particle–γ coincidence matrices, each constructed with different treatments of the γ–ray energies, are explored in order to observe the impact on the resulting nuclear level density and photon strength. The final photon strength function reported is found to agree well with previous Oslo measurements of other iron isotopes. Systematic uncertainties are included, using different model parameters and their reported errors to perform the Oslo method normalization. The model-independent Shape method is explored and the functional form of the photon strength function obtained is in agreement with the Oslo method results. A low-energy enhancement is not reported for 58 Fe in this work given possible subtraction issues originating from strongly populated states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Focusing a round coherent beam by spatial filtering the horizontal source

This paper illustrates the use of spatial filtering with a horizontal slit near the source to enlarge the horizontal coherence in an experimental station and produce a diffraction-limited round focus at an insertion device beamline for X-ray photon correlation spectroscopy experiments. Simple expressions are provided to guide the optical layout, and wave propagation simulations confirm their applicability. The two-dimensional focusing performance of Be compound refractive lenses to produce a round diffraction-limited focus at 11 keV capable of generating a high-contrast speckle pattern of an aerogel sample is demonstrated. The coherent scattering patterns have comparable speckle sizes in both horizontal and vertical directions. The focal spot sizes are consistent with hybrid ray-tracing calculations. Producing a two-dimensional focus on the sample can be helpful to resolve speckle patterns with modern pixel array detectors with high visibility. This scheme has now been in use since 2019 for the 8-ID beamline at the Advanced Photon Source, sharing the undulator beam with two separate beamlines, 8-ID-E and 8-ID-I at 7.35 keV, with increased partially coherent flux, reduced horizontal spot sizes on samples, and good speckle contrast.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast digital lossy compression for X-ray ptychographic data

Increases in X-ray brightness from synchrotron light sources lead to a requirement for higher frame rates from hybrid pixel array detectors (HPADs), while also favoring charge integration over photon counting. However, transfer of the full uncompressed data will begin to constrain detector design, as well as limit the achievable continuous frame rate. Here a data compression scheme that is easy to implement in a HPAD's application-specific integrated circuit (ASIC) is described, and how different degrees of compression affect image quality in ptychography, a commonly employed coherent imaging method, is examined. Using adaptive encoding quantization, it is shown in simulations that one can digitize signals up to 16383 photons per pixel (corresponding to 14 bits of information) using only 8 or 9 bits for data transfer, with negligible effect on the reconstructed image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of fast and efficient lossless compression algorithms for macromolecular crystallography experiments

Structural biology experiments benefit significantly from state-of-the-art synchrotron data collection. One can acquire macromolecular crystallography (MX) diffraction data on large-area photon-counting pixel-array detectors at framing rates exceeding 1000 frames per second, using 200 Gbps network connectivity, or higher when available. In extreme cases this represents a raw data throughput of about 25 GB s −1 , which is nearly impossible to deliver at reasonable cost without compression. Our field has used lossless compression for decades to make such data collection manageable. Many MX beamlines are now fitted with DECTRIS Eiger detectors, all of which are delivered with optimized compression algorithms by default, and they perform well with current framing rates and typical diffraction data. However, better lossless compression algorithms have been developed and are now available to the research community. Here one of the latest and most promising lossless compression algorithms is investigated on a variety of diffraction data like those routinely acquired at state-of-the-art MX beamlines.

36 MATERIALS SCIENCE↗

Dispersive X-ray absorption spectroscopy using independent grazing-incidence focusing and convexly bent Bragg-crystal dispersing optics

We present a modular instrument for dispersive X-ray absorption spectroscopy (DXAS) developed for the Advanced Spectroscopy Beamline at Sector 25 of the Advanced Photon Source. The setup employs a double-multilayer monochromator to provide X-rays with a broad energy bandwidth, Kirkpatrick–Baez mirrors for focusing, a convexly bent Bragg-crystal polychromator for energy dispersion, and a pixel-array detector to resolve all X-ray energies and collect their intensity simultaneously, thereby enabling acquisition of a full X-ray absorption spectrum in a single shot. The use of separate optics for X-ray focusing and energy dispersion provides high spatial resolution and avoids chromatic aberrations inherent in focusing bent-crystal optics, and a modular design makes implementation of the technique at other beamlines possible without requiring modifications to the upstream beamline configurations. Theoretical calculations are performed to determine optimal instrument operating parameters and demonstrate that an energy resolution better than the K-edge core-hole lifetime broadening can be maintained while providing a sufficient bandwidth for X-ray absorption near-edge structure spectroscopy through the full operating range of 5–11 keV. Additionally, instrument design, data analysis methods, and initial DXAS results on lithium–manganese–nickel oxide laminates are presented.

47 OTHER INSTRUMENTATION↗