Abstract: Air, Thermal and Water Management for PEM Fuel Cell Systems

PEM fuel cells are excellent candidates for transportation applications due to their high efficiencies. PEM fuel cell Balance of Plant (BOP) components, such as air, thermal, and water management sub-systems, can have a significant effect on the overall system performance, but have traditionally not been addressed in research and development efforts. Recognizing this, the U.S. Department of Energy and Honeywell International Inc. are funding an effort that emphasizes the integration and optimization of air, thermal and water management sub-systems. This effort is one of the major elements to assist the fuel cell system developers and original equipment manufacturers to achieve the goal of an affordable and efficient power system for transportation applications. Past work consisted of: (1) Analysis, design, and fabrication of a motor driven turbocompressor. (2) A systematic trade study to select the most promising water and thermal management systems from five different concepts (absorbent wheel humidifier, gas to gas membrane humidifier, porous metal foam humidifier, cathode recycle compressor, and water injection pump.) This presentation will discuss progress made in the research and development of air, water and thermal management sub-systems for PEM fuel cell systems in transportation applications. More specifically, the presentation will discuss: (1) Progress of the motor driven turbocompressor design and testing; (2) Progress of the humidification component selection and testing; and (3) Progress of the thermal management component preliminary design. The programs consist of: (1) The analysis, design, fabrication and testing of a compact motor driven turbocompressor operating on foil air bearings to provide contamination free compressed air to the fuel cell stack while recovering energy from the exhaust streams to improve system efficiency. (2) The analysis, design, fabrication and testing of selected water and thermal management systems and components to improve system efficiency and reduce packaging size.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and Analysis of a 25 MWe Supercritical CO2 Turbo Machine

This paper presents the design and analysis of a turbo machine operating with supercritical carbon dioxide (sCO2) in a 25 MWe Recompression Brayton Cycle (RCBC). The work was performed under US Department of Energy (DoE) program DE-EE-0010318. The design process involves the aerodynamic design of the compressor and turbine, including the initial layout of flowpaths and stage configurations to achieve high efficiency and performance. Additionally, a comprehensive rotodynamic analysis is performed to ensure the stability and reliability of the system. Conceptual designs for a high-speed motor and synchronous generator that match turbomachinery requirements are also developed from first principles.

42 ENGINEERING↗

Overview of design and analysis activities for the W7-X scraper element

The Wendelstein 7-X stellarator is in final stages of commissioning, and will begin operation in late 2015. In the first phase, the machine will operate with a limiter, and will be restricted to low power and short pulse. But in 2019, plans are for an actively cooled divertor to be installed, and the machine will operate in steady state at full power. Recently, plasma simulations have indicated that, in this final operational phase, a bootstrap current will evolve in certain scenarios. This will cause the sensitive ends of the divertor target to be overloaded beyond their qualified limit. A high heat flux scraper element (HHF-SE) has been proposed in order to take up some of the convective flux and reduce the load on the divertor. In order to examine whether the HHF-SE will be able to effectively reduce the plasma flux in the divertor region of concern, and to determine how the pumping effectiveness will be affected by such a component, it is planned to include a test divertor unit scraper element (TDU-SE) in 2017 during an earlier operational phase. Several U.S. fusion energy science laboratories have been involved in the design, analysis (structural and thermal finite element, as well as computational fluid dynamics), plasma simulation, planning, prototyping, and diagnostic development around the scraper element program (both TDU-SE and HHF-SE). As a result, this paper presents an overview of all of these activities and their current status.

42 ENGINEERING↗

Analysis of design control values for TEP

The Tokamak Exhaust Processing (TEP) Performance Requirements Report (USITER-13201-TD0005-R00), date May 29, 2007 defined feed sources for TEP quantities and approximate flow rate of gases from these individual sources. In addition, the report identified the approximate periods of time (during Burn and Dwell, 'Silent Shift', etc.) that these gases would be transferred to TEP. This report did not take into account the detailed, time dependent, sequencing options for receiving gases from these feed sources. Sequencing is critical in defining the actual design basis values (flow rates, etc.) for TEP. This report analyzes the time dependent sequencing of feed flows to TEP and defines the ,design basis values. This analysis is based on the values presented in the TEP Performance Requirements Report (TEP PRR), and indicates that the ITER Burn and Dwell, Silent Shift Following 16 hours of Burn and Dwell, Glow Discharge Cleaning (GDC), and Silent Shift following 100 hours of GDC scenarios are the limiting scenarios from which the design basis values will be defined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Uncertainty Analysis of CTF for the Uncertainty Analysis in Modeling Benchmark

This work describes the results of a quantitative sensitivity and uncertainty analysis of the thermal hydraulic subchannel code, Coolant Boiling in Rod Arrays - Three Field (COBRA-TF). Four steady state cases from Phase II, Exercise 3 of the Organisation for Economic Co-operation and Development/Nuclear Energy Agency Uncertainty Analysis in Modeling (OECD/NEA UAM) Benchmark are analyzed using the statistical analysis tool, Design Analysis Kit for Optimization and Tera-scale Applications (Dakota). This study supports the larger goal of the UAM Benchmark, which is to assess the uncertainty inherent in nuclear codes in a straightforward framework. The benchmark first focuses on assessing the uncertainty in stand-alone codes and then uses these results to propagate those uncertainties to coupled calculations. The work presented here adds to the existing results for this benchmark. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Niowave Design and Analysis of a 200 kW Converter

LANL is providing support to Niowave Inc. on the design and analysis of a 200 kW converter. The current design of the 200 kW (40 MeV, 5 mA electron beam) converter consists of LBE flowing from the top to the bottom. When compared to the Mk.5 20 kW converter, which flowed LBE from the bottom, flowing over a divider plate to create a waterfall, the 200 kW converter eliminates the divider plate, which would otherwise have melted with the higher beam power. Because the LBE flows from the top to the bottom, alternate methods to the divider plate need to be utilized to ensure a stable flow that minimizes splashing at the bottom of the LBE waterfall, while maintaining a uniform LBE thickness at the beam, and steady LBE flow at the desired flow rate.

43 PARTICLE ACCELERATORS↗

Uncertainty Quantification Study of CTF for the OECD/NEA LWR Uncertainty Analysis in Modeling Benchmark

This work describes the results of a quantitative uncertainty analysis of the thermal-hydraulic subchannel code for nuclear engineering applications, Coolant Boiling in Rod Arrays-Three Field (COBRA-TF). CTF is used, which is a version of COBRA-TF developed in cooperation between the Consortium for Advanced Simulation of Light Water Reactors and North Carolina State University. Four steady-state cases from Phase II Exercise 3 of the Organisation for Economic Co-operation and Development/Nuclear Energy Agency Light Water Reactor Uncertainty Analysis in Modeling (UAM) Benchmark are analyzed using the statistical analysis tool, Design Analysis Kit for Optimization and Terascale Applications (Dakota). The input parameters include boundary condition, geometry, and modeling uncertainties, which are selected using a sensitivity study and then defined based on expert judgment. Here, a forward uncertainty quantification method with Latin hypercube sampling (LHS) is used, where the sample size is based on available computational resources.

42 ENGINEERING↗

Design and Analysis for a Floating Oscillating Surge Wave Energy Converter: Preprint

This paper presents a recent study on the design and analysis of an oscillating surge wave energy converter. A successful wave energy conversion design requires the balance between the design performance and cost. The cost of energy is often used as the metric to judge the design of the wave energy conversion system. It is often determined based on the device power performance, the cost for manufacturing, deployment, operation and maintenance, as well as the effort to ensure the environmental compliance. The objective of this study is to demonstrate the importance of a cost driven design strategy and how it can affect a WEC design. Three oscillating surge wave energy converter (OSWEC) designs were used as the example. The power generation performance of the design was modeled using a time-domain numerical simulation tool, and the mass properties of the design were determined based on a simple structure analysis. The results of those power performance simulations, the structure analysis and a simple economic assessment were then used to determine the cost-efficiency of selected OSWEC designs. Finally, a discussion on the environmental barrier, integrated design strategy and the key areas that need further investigation is also presented.

17 WIND ENERGY↗

A new code for the design and analysis of the heliostat field layout for power tower system

A new code for the design and analysis of the heliostat field layout for power tower system is developed. In the new code, a new method for the heliostat field layout is proposed based on the edge ray principle of nonimaging optics. The heliostat field boundary is constrained by the tower height, the receiver tilt angle and size and the heliostat efficiency factor which is the product of the annual cosine efficiency and the annual atmospheric transmission efficiency. With the new method, the heliostat can be placed with a higher efficiency and a faster response speed of the design and optimization can be obtained. A new module for the analysis of the aspherical heliostat is created in the new code. A new toroidal heliostat field is designed and analyzed by using the new code. Compared with the spherical heliostat, the solar image radius of the field is reduced by about 30% by using the toroidal heliostat if the mirror shape and the tracking are ideal. In addition, to maximize the utilization of land, suitable crops can be considered to be planted under heliostats. To evaluate the feasibility of the crop growth, a method for calculating the annual distribution of sunshine duration on the land surface is developed as well. (author)

14 SOLAR ENERGY↗

Desiccant-Enhanced Evaporative Air Conditioning. Parametric Analysis and Design

This paper presents a parametric analysis using a numerical model of a new concept in desiccant and evaporative air conditioning. The concept consists of two stages: a liquid desiccant dehumidifier and a dew-point evaporative cooler. Each stage consists of stacked air channel pairs separated by a plastic sheet. In the first stage, a liquid desiccant film removes moisture from the process (supply-side) air through a membrane. An evaporatively-cooled exhaust airstream on the other side of the plastic sheet cools the desiccant. The second-stage indirect evaporative cooler sensibly cools the dried process air. We analyze the tradeoff between device size and energy efficiency. This tradeoff depends strongly on process air channel thicknesses, the ratio of first-stage to second-stage area, and the second-stage exhaust air flow rate. A sensitivity analysis reiterates the importance of the process air boundary layers and suggests a need for increasing airside heat and mass transfer enhancements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ECAR-6564 Rev 1 MARVEL Project Primary Coolant System ASME BPVC Section III Division 5 Design by Analysis

This report demonstrates that the MARVEL Reactor Primary Coolant Boundary (herein referred to as the Primary Coolant System, or PCS) is designed to meet ASME BPVC Section III Division 5 elevated temperature service design-by-analysis criteria. The analysis approach that delineates division of responsibilities to meet project objectives is discussed herein. In short, Design and Service Level A, B, and C code calculations are detailed in ECAR-6580 [9] for the majority of the PCS with complex geometry, while the Lower Downcomers, Bottom Head, and Reactor Core Barrel are analyzed in ANL-24/36. Service Level D code calculations are detailed in this document.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Niowave Design and Analysis of a High Power Converter - FY 21

LANL provided support to Niowave Inc. on the design and analysis of the Mk. 4 and Mk. 5, 20 kW converter. The Mk. 4 converter design consisted of lead bismuth eutectic (LBE) flowing over a divider plate to create a waterfall. Niowave, with feedback from LANL, improved on the Mk.4 divider plate and “horn” region of the converter to create the Mk. 5 version of the converter.

42 ENGINEERING↗

Physics-informed graph neural networks for predicting cetane number with systematic data quality analysis

Designing alternative fuels for advanced compression ignition engines necessitates a predictive model for cetane number (CN). In this study, the physics-informed graph neural networks are introduced for a reliable CN prediction by considering molecular features pertinent to the physical properties of molecules that affect CN. The reliability of measured data is another key factor to consider for improving the predictive model. Various experimental instruments for measuring CN exist, including standard and non-standard methods. In this regard, a systematic data quality analysis was carried out for the total 630 CNs collected from literature and new measurements in this study using Advanced Fuel Ignition Delay Analyzer (AFIDA). The results from this data curation process were reflected in the model by imposing lower sample weights on the data coming from less reliable measurement techniques. This approach effectively maximized the prediction accuracy while incorporating data from all available sources. Using the sample weights decreased the mean absolute error (MAE) up to 0.8 CN units. The accuracy was also improved by introducing the CN-related physical properties (the number of hydrogen bond donors and acceptors); the test set MAE is 5.74 and 7.01 for the model with and without such properties, respectively. Investigating molecular structural effects on CN was also carried out to gain chemical insights into factors used to design new fuel candidates. The dimensionality reduction analysis of feature vectors showed a clear clustering in terms of functional groups and CN and the structural effect derived from the model was consistent with the physicochemical insights. Finally, this physics-informed model and data curation would be helpful for accurate CN prediction and inform rational fuel design.

97 MATHEMATICS AND COMPUTING↗

Full long-term design response analysis of a wave energy converter

Efficient design of wave energy converters requires an accurate understanding of expected loads and responses during the deployment lifetime of a device. A study has been conducted to better understand best-practices for prediction of design responses in a wave energy converter. A case-study was performed in which a simplified wave energy converter was analyzed to predict several important device design responses. The application and performance of a full long-term analysis, in which numerical simulations were used to predict the device response for a large number of distinct sea states, was studied. Environmental characterization and selection of sea states for this analysis at the intended deployment site were performed using principle-components analysis. The full long-term analysis applied here was shown to be stable when implemented with a relatively low number of sea states and convergent with an increasing number of sea states. As the number of sea states utilized in the analysis was increased, predicted response levels did not change appreciably. Furthermore, uncertainty in the response levels was reduced as more sea states were utilized.

42 ENGINEERING↗

Adjoint design sensitivity analysis of reduced atomic systems using generalized Langevin equation for lattice structures

An efficient adjoint design sensitivity analysis method is developed for reduced atomic systems. A reduced atomic system and the adjoint system are constructed in a locally confined region, utilizing generalized Langevin equation (GLE) for periodic lattice structures. Due to the translational symmetry of lattice structures, the size of time history kernel function that accounts for the boundary effects of the reduced atomic systems could be reduced to a single atom’s degrees of freedom. For the problems of highly nonlinear design variables, the finite difference method is impractical for its inefficiency and inaccuracy. However, the adjoint method is very efficient regardless of the number of design variables since one additional time integration is required for the adjoint GLE. Through numerical examples, the derived adjoint sensitivity turns out to be accurate and efficient through the comparison with finite difference sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fourier Analysis and Design of a Shielded 120kW Inductive Wireless System

High-power inductive wireless power transfer (WPT) systems for EVs are designed to meet specifications such as stray field, power level, efficiency, misalignment tolerance, and ground clearance. These metrics are all heavily influenced by the coil geometry. Herein this paper proposes a coil design method based on the Fourier Analysis Method (FAM) which is an analytical method for directly designing coil geometries to meet stray field and power level requirements through an optimization of Fourier basis function coefficients. In this work, two 120 kW WPT proof-of-concept demonstrators with low stray field and high efficiency are built from FAM optimization results to validate the models and show the impact of the FAM design process. Experimental validation of the Gen. 2 demonstrator at 120 kW output power resulted in a measured DC/DC efficiency of 97.2% at alignment with a 125 mm airgap. At the 120 kW test point, the stray fields 80 cm away from the center of the airgap between the coil assemblies were 3.4 µT(rms) on the X-axis and 3.5 µT(rms) on the Y-axis, much lower than the 27 µT(rms) ICNIRP limit.

42 ENGINEERING↗

Design and Analysis of a Mutual Inductance Level Sensor for Liquid Metals

Here, this article describes the design and analysis of an electromagnetic level sensor for use in high-temperature liquid metal systems. The mutual inductance level sensor (MILS) described in this work was fabricated using two single-conductor mineral insulated cables wrapped in a bifilar fashion around a stainless steel tube core and was housed in an isolating thimble that preserved the pressure boundary of the test vessel. Two sensor variations were fabricated that differ only in active length, 1016 and 1778 mm. Experimental data were collected using the 1016-mm sensor (MILS-MKII-040) that demonstrated a sensitivity of 9.2 μ V/mm in a room temperature testing stand that used solid aluminum as a surrogate for liquid metal. Experimental data were collected using the 1778-mm sensor (MILS-MKII-070) that demonstrated a sensitivity of 6.9 μ V/mm in the high-temperature (300 ° C) liquid sodium environment at the mechanisms engineering test loop (METL) of Argonne National Laboratory. The sensor performance was found to be repeatable over the course of several months, with roughly ±1% deviation from nominal output. Finite element models were developed in COMSOL Multiphysics that fully describe each test setup, and the models were validated using experimental data. The validated COMSOL models were used to perform an array of analyses that examined the performance of the sensor in differing environments. Maximizing the coil diameter inside the isolating thimble was found to maximize the signal and sensitivity of the sensor. An optimal operating frequency was found near 1000 Hz using both experimental data and COMSOL. The influence of a metallic thimble surrounding the sensor and a metallic sensor core was quantified and found to be negligible at the optimal operating frequency. The sensitivity of the sensor was quantified when monitoring the level of additional liquid metals. These include lead, lead-bismuth eutectic (LBE), sodium-potassium alloy (NaK), and lithium (in addition to sodium). The sensitivities were quantified using liquid metal properties at 350 ° C and 650 ° C. The geometry of the test stand model, all material properties used in the model, and the results are presented in a manner that allows the reader can replicate the model and perform additional analyses.

COMSOL↗