Clean Water Production in Cooling Towers

This project developed and demonstrated a novel technology that produces clean water from cooling tower recirculating water by using the natural evaporation and condensation cycle inside cooling towers. The system captures the escaping plume and converts blowdown quality water into high purity water suitable for on-site reuse such as boiler feed. The technology uses electric fields to ionize exhaust plumes, charge the entrained droplets, and direct them toward collection electrodes where they coalesce and flow downward. This allows water recovery at a low energy cost while reducing visible plume emissions. In addition, we developed a complementary software platform that improves overall cooling tower performance. The system uses wireless sensors and physics-based machine learning algorithms to optimize key parameters of the cooling process. For power generation facilities, this increases the thermal efficiency of the cooling loop and condenser, resulting in measurable cycle efficiency gains. Improvements of one percent or more can deliver significant increases in electricity production for the same fuel input.

01 COAL, LIGNITE, AND PEAT↗

Thermosyphon Cooler Hybrid System for Water Savings in an Energy-Efficient HPC Data Center: Modeling and Installation: Preprint

The Thermosyphon Cooler Hybrid System (TCHS) integrates the control of a dry heat rejection device, the thermosyphon cooler (TSC), with an open cooling tower. A combination of equipment and controls, this new heat rejection system embraces the 'smart use of water,' using evaporative cooling when it is most advantageous and then saving water and modulating toward increased dry sensible cooling as system operations and ambient weather conditions permit. Innovative fan control strategies ensure the most economical balance between water savings and parasitic fan energy. The unique low-pressure-drop design of the TSC allows water to be cooled directly by the TSC evaporator without risk of bursting tubes in subfreezing ambient conditions. Johnson Controls partnered with the National Renewable Energy Laboratory (NREL) and Sandia National Laboratories to deploy the TSC as a test bed at NREL's high-performance computing (HPC) data center in the first half of 2016. Located in NREL's Energy Systems Integration Facility (ESIF), this HPC data center has achieved an annualized average power usage effectiveness rating of 1.06 or better since 2012. Warm-water liquid cooling is used to capture heat generated by computer systems direct to water; that waste heat is either reused as the primary heat source in the ESIF building or rejected using evaporative cooling. This data center is the single largest source of water and power demand on the NREL campus, using about 7,600 m3 (2.0 million gal) of water during the past year with an hourly average IT load of nearly 1 MW (3.4 million Btu/h) -- so dramatically reducing water use while continuing efficient data center operations is of significant interest. Because Sandia's climate is similar to NREL's, this new heat rejection system being deployed at NREL has gained interest at Sandia. Sandia's data centers utilize an hourly average of 8.5 MW (29 million Btu/h) and are also one of the largest consumers of water on Sandia's site. In addition to describing the installation of the TSC and its integration into the ESIF, this paper focuses on the full heat rejection system simulation program used for hourly analysis of the energy and water consumption of the complete system under varying operating scenarios. A follow-up paper will detail the test results. The evaluation of the TSC's performance at NREL will also determine a path forward at Sandia for possible deployment in a large-scale system not only for data center use but also possibly site wide.

97 MATHEMATICS AND COMPUTING↗

Energy Performance Evaluation of Aquila's Aquarius Fixed Cold Plate Cooling System at NREL's High Performance Computing Center

In the first half of 2018, as part of a partnership with Sandia National Laboratories, Aquila installed its fixed cold plate, liquid-cooled Aquarius rack solution for high-performance computing (HPC) clustering at the National Renewable Energy Laboratory's (NREL's) Energy Systems Integration Facility (ESIF). This new fixed cold plate, warm-water cooling technology together with a manifold design provides easy access to service nodes and eliminates the need for server auxiliary fans altogether. Aquila and Sandia National Laboratories chose NREL's HPC Data Center for the initial installation and evaluation because the data center is configured for liquid cooling and has the required instrumentation to measure flow and temperature differences to facilitate testing. This paper gives an overview of the Aquarius fixed cold plate cooling technology and provides results from early energy performance evaluation testing.

97 MATHEMATICS AND COMPUTING↗

Data Center Cybersecurity, Supply Chain Risk Management, and Emerging Regulation Cohort Summary: Takeaways and Action Plans

This report summarizes the outcomes of the Data Center Cohort under the Department of Energy’s Technical Assistance for Digital Assurance (TADA) initiative, aimed at enhancing grid resilience through cybersecurity, supply chain risk management (SCRM), and Cyber-Informed Engineering (CIE). The cohort engaged 17 organizations across utilities, data center operators, vendors, and technology providers in three sessions combining presentations, discussions, and exercises. Key topics included AI-driven load behavior, cybersecurity vulnerabilities in UPS/BESS and cooling systems, governance gaps at utility–data center boundaries, and supply chain integrity. Five cross-cutting themes emerged: interconnection architecture vulnerabilities, fragmented governance, AI-driven stability risks, lack of regulatory frameworks, and long-term supply chain concerns. Actionable recommendations were developed, including implementing DMZ segmentation, formalizing vendor access agreements, designing AI workload limits, and advancing standards through NERC and state-level programs. These strategies aim to strengthen resilience, clarify responsibilities, and ensure secure integration of data centers into the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Thermosyphon Cooler Hybrid System for Water Savings in an Energy-Efficient HPC Data Center: Results from 24 Months and the Impact on Water Usage Effectiveness

In August 2016, the National Renewable Energy Laboratory (NREL) installed a thermosyphon hybrid cooling system to reduce water usage in its already extremely energy-efficient High-Performance Computing (HPC) Data Center. In its first year of use, the system saved 4,400 m3 (1.16 million gal) of water, and 7,950 m3 (2.10 million gal) during a 2-year period, cutting the use of water in the data center by about one-half. NREL's 930-m2 (10,000-ft2) HPC Data Center is often called the most energy-efficient data center in the world: it has achieved a trailing 12-month average power usage effectiveness of 1.034, and it features a chiller-less design, component-level warm-water liquid cooling, and waste heat capture and reuse. NREL considered the amount of water used by the cooling towers to be counter to the laboratory's sustainability mission, so a team of researchers from NREL, Sandia National Laboratories (Sandia), and Johnson Controls integrated the BlueStream thermosyphon cooler (TSC) - an advanced dry cooler that uses refrigerant in a passive cycle to dissipate heat - on the roof of NREL's Energy Systems Integration Facility, the building that houses the HPC Data Center. In combination with the existing cooling towers, the TSC forms an extremely water- and cost-efficient cooling system. In its first year of operation, on-site water usage effectiveness (WUE) was 0.70 L/kWh. In comparison, the WUE would be 1.27 L/kWh if NREL had continued using only heat-recovery and cooling towers. This on-site water savings was accomplished without negatively impacting the energy-efficient operation of the HPC Data Center. The TSC system technology has the potential for application in data centers around the world, and it is currently being implemented by Sandia. center by about one-half. NREL's 930-m2 (10,000-ft2) HPC Data Center is often called the most energy-efficient data center in the world: it has achieved a trailing 12-month average power usage effectiveness of 1.034, and it features a chiller-less design, component-level warm-water liquid cooling, and waste heat capture and reuse. NREL considered the amount of water used by the cooling towers to be counter to the laboratory's sustainability mission, so a team of researchers from NREL, Sandia National Laboratories (Sandia), and Johnson Controls integrated the BlueStream thermosyphon cooler (TSC) - an advanced dry cooler that uses refrigerant in a passive cycle to dissipate heat - on the roof of NREL's Energy Systems Integration Facility, the building that houses the HPC Data Center. In combination with the existing cooling towers, the TSC forms an extremely water- and cost-efficient cooling system. In its first year of operation, on-site water usage effectiveness (WUE) was 0.70 L/kWh. In comparison, the WUE would be 1.27 L/kWh if NREL had continued using only heat-recovery and cooling towers. This on-site water savings was accomplished without negatively impacting the energy-efficient operation of the HPC Data Center. The TSC system technology has the potential for application in data centers around the world, and it is currently being implemented by Sandia.

97 MATHEMATICS AND COMPUTING↗

Accelerating Nuclear-Integrated Data Centers in the USA: SWOT Analysis, Power-Thermal Management Strategies, and Industrial-Scale Demonstration and Potential Deployment

Driven by the growth in digital services, cloud computing, AI, and manufacturing, data centers face rising energy demands that challenge traditional power sources and cooling efficiency. This study explores using nuclear power to meet these demands, focusing on accelerated reactor technology deployment and highlighting needs such as N+1/N+2 power supplies and integrated power-thermal management. A SWOT analysis addresses grid connectivity, reactors, and site selection, particularly DOE sites. Reactor technology demonstration and deployment could be accelerated by leveraging test facilities such as MARVEL, MAGNET, TED, FAS, DOME, LOTUS, ATR, Energy System Proving Grounds, and upcoming Energy Launch Pads, along with modeling and simulation tools such as RELAP5, MOOSE, VERA, RAVEN, and FORCE. The potential power and thermal management options, including various cooling technologies, waste-heat utilization, and an industrial-scale demonstration plan, aim to accelerate the integration of nuclear power and data centers in the USA, while emphasizing community and stakeholder engagement and synergistic efforts.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

NREL Data Center Cuts Water Use in Half With Hybrid Thermosyphon System

In 2016, NREL installed a thermosyphon hybrid cooling system to reduce water use in the already extremely energy efficient data center at the Energy Systems Integration Facility. In this video, NREL Computational Science Center Director Steve Hammond describes how the system has successfully cut onsite water use in half without negative impacts to the data center’s energy efficient operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reducing Data Center Loads for a Large-Scale, Net Zero Office Building

In constructing a new research facility for its campus, the National Renewable Energy Laboratory (NREL) project team identified the opportunity to design a world-class, energy-efficient data center to support its operations. NREL’s efforts resulted in a highly efficient data center that demonstrated considerable energy savings in its first 11 months of operations. Using legacy data center performance as a baseline, the new facility cut energy use by nearly 1,450,000 kWh, delivering cost savings of approximately $82,000. The data center’s average total load was 165 kW less than the legacy center’s average total load, resulting in a 60% reduction in overall power. Finally, the limited use of cooling and fan energy enabled the new data center to achieve a 1.16 average power utilization effectiveness (PUE) rating, compared to the legacy data center’s PUE of 2.28.

Reducing, Data, Large-Scale, Net-Zero, Office, Bui↗

Demand Response and Open Automated Demand Response Opportunities for Data Centers

This study examines data center characteristics, loads, control systems, and technologies to identify demand response (DR) and automated DR (Open Auto-DR) opportunities and challenges. The study was performed in collaboration with technology experts, industrial partners, and data center facility managers and existing research on commercial and industrial DR was collected and analyzed. The results suggest that data centers, with significant and rapidly growing energy use, have significant DR potential. Because data centers are highly automated, they are excellent candidates for Open Auto-DR. 'Non-mission-critical' data centers are the most likely candidates for early adoption of DR. Data center site infrastructure DR strategies have been well studied for other commercial buildings; however, DR strategies for information technology (IT) infrastructure have not been studied extensively. The largest opportunity for DR or load reduction in data centers is in the use of virtualization to reduce IT equipment energy use, which correspondingly reduces facility cooling loads. DR strategies could also be deployed for data center lighting, and heating, ventilation, and air conditioning. Additional studies and demonstrations are needed to quantify benefits to data centers of participating in DR and to address concerns about DR's possible impact on data center performance or quality of service and equipment life span.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Metal additively manufactured wavy fin cold-plate architecture for improved thermal-hydraulic performance

Rapid growth in artificial intelligence and data center workloads demands high-performance liquid cooling to manage increasing chip power. This study presents two metal-additive-manufactured cold plates with sinusoidal fins, constant-amplitude wavy fins and linearly variable-amplitude wavy fins and compares them against metal-additive-manufactured straight fins using experiments conducted at 1 kW heat dissipation as well as high-fidelity 3D conjugate computational fluid dynamic simulations. The cold plates were printed in AlSi10Mg material and underwent design using a Python-automated workflow prior to manufacture and testing. The experiments show that wavy fins reduce the normalized thermal resistance by 35 to 45 % at water flow rates from 1 to 4 LPM. At a fixed 20 kPa pressure drop, the variable-waviness design lowered peak surface temperature by 9 °C and thermal resistance by 51 %, while edge-channel maldistribution in the constant wavy fin design limited gains. A thermal resistance breakdown revealed that 55–63 % of the total thermal resistance in wavy designs comes from base heat conduction, 27–33 % from fin heat conduction, and 9–13 % from fin heat convection, indicating the need to address conduction bottlenecks. Parametric sweeps identify a 3 mm fin pitch as optimal, and that horizontal inlet/outlet manifolds further reduce pressure drop by 30–60 % and thermal resistance by 9–16 % relative to vertical inlet-outlet manifolds. The results yield comprehensive guidelines for fin geometry, manifold alignment, material selection and additive-manufacturing constraints to realize high-performance liquid-cooled cold plates for power-dense electronics.

3d printing↗

MSD CoP Webinar: Energy and AI

Context: This webinar was hosted by the MultiSector Dynamics Community of Practice (MSD CoP; https://multisectordynamics.org). Abstract: Projections of the need for new data centers to support Artificial Intelligence (AI) are large but highly uncertain. Recent projections indicate up to a 15% annual growth rate in data center electricity demand within the next 5-10 years. Given that most electric utilities are required to have a reserve margin of roughly the same magnitude as the projected growth in demand, these new data center loads could soon threaten resource adequacy and reliability unless data centers build their own generation, interruptible loads are negotiated, commensurate new capacity and/or transmission is built, or some combination of these options. Similarly, depending on the cooling technology and geographic location of new data centers, they could threaten water adequacy in water scarce regions. This webinar will provide an overview of the interactions between energy and AI and highlight two MSD projects exploring the grid and water implications of new data centers to support AI. Presenters : Dr. Casey Burleyson (Pacific Northwest National Laboratory); Dr. Stephanie Morris (Pacific Northwest National Laboratory); Kendall Mongird (Pacific Northwest National Laboratory) Moderator: Patrick M. Reed (MSD CoP Facilitation Team) This webinar was held on: June 16th, 2025 from 1-2 PM EST.

Artificial Intelligence↗

Energy and AI: Evaluating Future Grid and Water Stress Due to Data Centers

Projections of the need for new data centers to support Artificial Intelligence (AI) are large but highly uncertain. Recent projections indicate up to a 15% annual growth rate in data center electricity demand within the next 5-10 years. Given that most electric utilities are required to have a reserve margin of roughly the same magnitude as the projected growth in demand, these new data center loads could soon threaten resource adequacy and reliability unless data centers build their own generation, interruptible loads are negotiated, commensurate new capacity and/or transmission is built, or some combination of these options. Similarly, depending on the cooling technology and geographic location of new data centers, they could threaten water adequacy in water scarce regions. This presentation highlights the grid and water implications of new data centers to support AI.

Mongird, Kendall (ORCID:0000000328077088)↗

Over-Luminous Elliptical Galaxies

We have completed a first draft of a paper on the galaxy group ESO3060170, the hottest known fossil group. We have submitted a first draft of the paper but the final completion is delayed due to several issues mentioned by the referee that we wish to revisit and discuss in more detail. The XMM data was combined with Chandra data which allowed a rich set of projects. The paper discusses the north-south elongation which is similar to that of the central dominant galaxy as well as the galaxy distribution. We detect an X-ray 'finger' or small tail emanating from the central galaxy to the north, suggesting motion of the galaxy within the elongated gravitational potential. The overall agreement between XMM and Chandra data are excellent (although the XMM data extend to larger radii). Both data sets show a cool core centered on the dominant galaxy. Surprisingly, - the temperature maps and detailed spectra indicate that the finger of gas is NOT cool, but has the same temperature as the ambient gas. We extracted surface brightness profiles, deprojected gas density profiles, cooling time profiles, and entropy profiles. There is a sharp discontinuity in gas temperature where the surface brightness profile starts to rise rapidly at 10 kpc. This produces a decrease in the cooling time and the gas entropy within 10 kpc. The central cooling time (within 10 kpc) is less than 109 years and falls to almost half that value in the inner 5 kpc. Despite the very short cooling time, we find no evidence (even with the excellent statistics from XMM-Newton) for multi-phased gas, i.e., a cooling flow. We find two 'edges' associated with the gas distribution (common in peaked X-ray groups and galaxies). On large scales, the temperature profile is flat and disagrees with the profile predicted by Loken et al. (2003) from detailed numerical simulations. We studied the galaxy distribution within one virial radius. The galaxy concentration associated with the group is detectable only within 0.3 of the virial radius (450 kpc) given the available depth of the optical galaxy catalogs at present. We have derived total mass and gas mass distributions (from the X-ray data) and find the gas fraction approaches a constant 8% (for H0 = 70).

Mushotsky, Richard↗

Over-Luminous Elliptical Galaxies

We have completed a first draft of a paper on the galaxy group ES03060170, the hottest known fossil group. We have submitted a first draft of the paper but the final completion is delayed due to several issues mentioned by the referee that we wish to revisit and discuss in more detail. The XMM data was combined with Chandra data which allowed a rich set of projects. The paper discusses the north-south elongation which is similar to that of the central dominant galaxy as well as the galaxy distribution. We detect an X-ray "finger" or small tail emanating from the central galaxy to the north, suggesting motion of the galaxy within the elongated gravitational potential. The overall agreement between XMM and Chandra data are excellent (although the XMM data extend to larger radii). Both data sets show a cool core centered on the dominant galaxy. Surprisingly, the temperature maps and detailed spectra indicate that the finger of gas is NOT cool, but has the same temperature as the ambient gas. We extracted surface brightness profiles, deprojected gas density profiles, cooling time profiles, and entropy profiles. There is a sharp discontinuity in gas temperature where the surface brightness profile starts to rise rapidly at 10 kpc. This produces a decrease in the cooling time and the gas entropy within 10 kpc. The central cooling time (within 10 kpc) is less than l0(exp 9) years and falls to almost half that value in the inner 5 kpc. Despite the very short cooling time, we find no evidence (even with the excellent statistics from XMM-Newton) for multi-phased gas, i.e., a cooling flow. We find two "edges" associated with the gas distribution (common in peaked X-ray groups and galaxies). On large scales, the temperature profile is flat and disagrees with the profile predicted by Loken et al. (2003) from detailed numerical simulations. We studied the galaxy distribution within one virial radius. The galaxy concentration associated with the group is detectable only within 0.3 of the virial radius (450 kpc) given the available depth of the optical galaxy catalogs at present. We have derived total mass and gas mass distributions (from the X- ray data) and find the gas fraction approaches a constant 8% (for Ho = 70).

Mushotzky, Richard↗

Servers Made to Order

Virtualization is a hot buzzword right now, and it’s no wonder federal agencies are coming around to the idea of consolidating their servers and storage. Traditional servers do nothing for about 80% of their lifecycle, yet use nearly half their peak energy consumption which wastes capacity and power. Server virtualization creates logical "machines" on a single physical server. At the Pacific Northwest National Laboratory in Richland, Washington, using virtualization technology is proving to be a cost-effective way to make better use of current server hardware resources while reducing hardware lifecycle costs and cooling demands, and saving precious data center space. And as an added bonus, virtualization also ties in with the Laboratory’s mission to be responsible stewards of the environment as well as the Department of Energy’s assets. This article explains why even the smallest IT shops can benefit from the Laboratory’s best practices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗