Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data Center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

NEXUS-DC: Nuclear Energy eXpedition for US Data Centers [Slides]

This presentation covers the growing interest in utilizing nuclear power to satisfy the increasing energy demands of data centers in the United States, emphasizing the factors that accelerate reactor deployment. It addresses clean and reliable energy needs, highlights the importance of power supply redundancy for reliability, and discusses challenges and solutions related to cooling, waste heat reuse, and techno-economics. Additionally, it includes a strength, weakness, opportunities and threat analysis and emphasizes community engagement and collaboration for accelerating regulatory approvals and reactor deployment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Implications of AI and Data Center Service Demand on Energy, Water, and Economic Systems

This talk focuses on the challenges posed by the rapid growth of data centers (DCs), which rely heavily on electricity, water, land, and mineral resources, and have significant interactions with economic growth. The U.S. leads in DC deployment, but understanding how resource demands and constraints impact DC expansion requires strategic multisector analysis. To address this, the talk introduces a new conceptual framework and modeling capability within GCAM-USA, allowing integrated analysis of DC service demand, electricity, and direct and indirect water needs under varied scenarios. Insights include state-level water and electricity trends for DCs, uncertainty bounds, and the broader implications for resources and economics.

Data Centers↗

Nuclear Power Plant Colocation with Data Centers

This presentation is an overview of the nuclear siting and licensing process, including specific considerations and challenges for nuclear power plant colocation with data centers.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Data Placement Optimization for ATLAS in a Multi-Tiered Storage System within a Data Center

Scientific experiments and computations, especially in High Energy Physics, are generating and accumulating data at an unprecedented rate. Effectively managing this vast volume of data while ensuring efficient data analysis poses a significant challenge for data centers, which must integrate various storage technologies. This paper proposes addressing this challenge by designing and developing a precise data popularity prediction model utilizing state-of-theart AI/ML techniques. This model is crafted from the analysis of ATLAS data and access patterns. It enables us to migrate infrequently accessed data to more economical storage media, such as tape drives, while storing frequently accessed data on faster yet costlier storage media like HDD or SSD. This strategic approach ensures data is placed optimally into the appropriate storage classes, thereby maximizing storage capacity while minimizing data access latency for end-users. Furthermore, the paper includes a performance evaluation of the prediction model using various key metrics such as F1 score, accuracy, precision and recall. Finally, we present a prototype use case, leveraging real-world file access data to assess the model’s impact on performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reliable Integration of AI Data Centers at Scale – Analysis, Modeling and Synthetic Data Generation

This report analyzes the power consumption of large dynamic digital loads using the open-source MIT supercloud and SURF datasets. With an emphasis on the MIT data, we calculate important power consumption characteristics to help system operators improve generation planning and resource allocation. We also introduce a rudimentary model for generating synthetic load profiles.

97 MATHEMATICS AND COMPUTING↗

Data Center Energy Efficiency

Fact sheet describes how the Federal Energy Management Program helps federal agencies implement data center energy efficiency projects.

Kam, Kendall [US Department of Energy (USDOE) Fede↗

Extreme Efficiency 240 Vac to Load Data Center Power Delivery Topologies and Control

The research explored innovative new circuit topologies and power converter architectures for data center power delivery, from the 240 V ac voltage at the input of a server rack, down to the less than 1 V dc power supply of the latest microprocessors. The research pursued three parallel tracks to increase the power conversion efficiency and to reduce the overall size of the servers: 1) An innovative new ac-dc power converter topology which enables improved efficiency through use of a novel direct step-down topology, well suited for the popular 48V dc power distribution. 2) A new series-stacked power delivery approach for servers comprising a large number of similar loads, such as hard drives in storage servers. The approach greatly reduces the power conversion losses, and achieves efficiency well over 99%. 3) A new family of hybrid switched-capacitor power converters that enable improved efficiency and reduced size through the use of dense ceramic capacitors and new circuit topologies that leverage GaN and low-voltage Si transistor technology. Together, the accomplished research achieved the goal of reducing the power conversion losses in datacenters, thereby reducing greenhouse gas emissions, operating costs, and overall electricity consumption.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

Enhancing Discoverability and Management of Atmospheric Data at Scale: Solutions from the ARM Data Center

The Atmospheric Radiation Measurement (ARM) is a multi-laboratory and multi-institutional U.S. Department of Energy (DOE) Office of Science National User Facility. The ARM Data Center (ADC), located at Oak Ridge National Laboratory, collects, archives, and shares vast atmospheric data crucial for climate research. The ADC manages over 7 PB of data from 460 instruments worldwide, processing it into more than 11,000 diverse data products using the Network Common Data Form (NetCDF) for machine-independent accessibility. The primary challenge addressed in this paper is the efficient management and distribution of vast and diverse datasets essential for the climate research community, enhancing accessibility through advanced tools like Data Discovery. The ADC has developed advanced infrastructure and software architecture to handle the continuous influx of heterogeneous data to enhance data discoverability, resulting in increased scientific collaboration. In 2023, users from over 34 countries downloaded and utilized ARM data, resulting in 1,455 publications. The ADC’s efforts have significantly improved the discoverability and usability of atmospheric data, fostering extensive scientific research and collaboration. This paper details the solutions implemented by the ADC team for efficient data discovery and distribution, and it demonstrates ARM’s capability of staging processed data for scientific analysis.

Shah, Chirag [ORNL] (ORCID:0000000203145737)↗

Preliminary Analysis of Nuclear-Powered Data Center Scenarios

This report provides a comprehensive analysis of the potential for nuclear energy to meet the growing energy demands of data centers (DCs). It evaluates the technical, economic, and socio-environmental implications of coupling Nuclear Power Plants (NPPs) with DCs, providing initial responses to several key research questions: What is the potential increased energy demand from DCs in the U.S., in the short, medium and long term? The U.S. is experiencing a rapid increase in energy demand from DCs, with projections indicating a total increase of 24-74 GWy(e) by 2028. Meeting this demand with nuclear energy would require 27–85 GWe of installed capacity. While this surge is expected to slow in the long term, the DC industry needs reliable, scalable, and clean energy sources. How much nuclear capacity can be deployed to meet DC demand and in which timeframe? Several pathways for increasing nuclear capacity were identified, including uprates, restarts of recently retired reactors, power purchase agreements with existing fleet, and new construction. Approximately 20‒28 GWe of nuclear capacity could be dedicated to DCs by the early 2030s. How much High Assay Low Enriched Uranium (HALEU) would be needed to support some nuclear deployment scenarios for DCs? Meeting the deployment targets announced by Google and Amazon for the Kairos Power Fluoride-Salt-Cooled High-Temperature Reactor or KP-FHR (~500 MWe by 2035) and the Xe-100 (~1 GWe by 2040), respectively, requires ramping up 19.75% enriched HALEU production to ~6 t/yr by 2040. What types of nuclear energy/DC coupling options exist, and what are the different benefits/challenges? Five coupling options were analyzed, ranging from grid-connected configurations to colocated, behind-the-meter setups. Key design considerations include the proximity to high- and/or medium-voltage transmission lines, the desired internal fault tolerance, and the sources of alternative/backup power during outages. Each coupling option offers unique benefits and challenges in terms of reliability, system costs, regulation, timeline, etc. A list of NPP/DC deployment scenarios was developed, considering existing or newly built NPP or DC projects. Colocated DCs with new small modular reactors or large reactors on greenfield and brownfield sites are the focus of this report. What types of reactors, especially what size, may be incentivized by DCs? Reactor sizing optimization revealed that the ideal reactor size and number of units depend on DC demand, coupling configurations defined in this report, and other economic factors. Larger reactors are preferred for high-demand DCs and grid-connected systems, while larger number of smaller reactors are better suited for DC configurations without grid backup. Which sites may be compatible with co-located nuclear-powered DCs? Siting those projects is a complicated evaluation factoring local water resources, grid connection availability and reliability, IT infrastructure, local work force, proximity to population zones, etc. For this effort greenfield and brownfield sites such as retired coal-fired plants were used to evaluate this question. This evaluation is not meant to recommend any particular site but it highlights key siting criteria and demonstrates large-scale site availability. What are the socio-economic impacts of co-located nuclear-powered DCs? Those projects generate substantial economic benefits to the local economy, particularly in urban settings. Hyperscale DCs colocated with nuclear power plants (sized around 1 GW of power) can create nearly 1,700 jobs for annual operations and more than 7,300 jobs among the supply chain and local businesses as a result of increased household spending. Rural projects also provide significant benefits, but at lower magnitudes compared to urban deployments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Exploring the Limits of Cooling for Extreme Heat Flux Applications: Data Centers and Power Electronic

We developed an Extreme Heat Flux Micro-cooler (EHFµ-C) capable of removing heat flux of ~1 kW/cm 2 with a small temperature rise ~10°C. This represents greater than 10× reduction in thermal resistance compared to the state-of-the-art single-phase cooling technologies (~0.5 cm 2 -°C/W) that greatly increases the efficiency, resulting in improved performance and reliability for microprocessors and power electronics. The EHFµ-Cooler utilizes liquid wicking (no pump) and thin-film evaporation in a 30 µm thick wick porous microstructure such as copper inverse opal (CIO), silicon and AlN pin fins along with a 3D manifold (copper wiremesh and silicon) with liquid routing and vapor extraction channels achieving an unprecedented vapor quality ~ >0.9. The proposed EHFµ-Cooler significantly reduces device temperature, resulting in 25-50% improvement in reliability and device performance. Based on very conservative estimates, the total energy saving for data centers due to improved performance can be 6 billion kWh/year (>$300M). Better cooling, leading to more efficient, higher performance and more reliable power electronics, would save the nation 3 Quad of primary energy in 2030. Just for automotive application, a 10% increase in fuel efficiency for SiC-based power electronics equates to >20 million gallons of fuel savings annually. The proposed EHFµ-Cooler technology ensures the United States maintains its technological lead in high-performance computing and high-power electronics, while at the same time improving the energy efficiency, and as a result reducing energy-related emissions such as greenhouse gases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Toward lower-diameter large-scale HPC and data center networks with co-packaged optics

We investigate the advantages of using co-packaged optics for building low-diameter, large-scale high-performance computing (HPC) and data center networks. The increased escape bandwidth offered by co-packaged optics can enable high-radix switch implementations of more than 150 switch ports, which can be combined with data rates of up to 400 Gb/s per port. From the network architecture perspective, the key benefits of using co-packaged optics in future fat-tree networks include (a) the ability to implement large-scale topologies of > <#comment/> 11 , 000 end points by eliminating the need for a third switching layer and (b) the ability to provide up to 4 × <#comment/> higher bisection bandwidth compared to existing solutions, reducing at the same time the number of required switch application-specific integrated circuits by > <#comment/> 80 % <#comment/> . From the network operation perspective, both reduced energy consumption and lower packet delays can be achieved since fewer hops are required; i.e., packets need to traverse fewer serializer/deserializer lanes and fewer switch buffers, which reduces the probability of contending with other packets and improves the tolerance of network congestion. The performance of the proposed architecture is evaluated via discrete-event simulations for a wide range of representative HPC synthetic-traffic cases that include both hotspot and non-hotspot scenarios. The simulation results suggest that co-packaged optics form a promising solution to keep up with bandwidth scaling in future networks, while the reduced number of switching layers can lead to significant mean packet delay improvements that start from 30% and reach up to 74% for high-load conditions.

Maniotis, Pavlos (ORCID:0000000244905253)↗

ORNL Campus Sustainability and Decarbonization using Waste Heat Recovery from the Oak Ridge Leadership Computing Facility’s High-Performance Computing Data Center

Heat pumps are a clean and efficient technology that can be powered by renewable electricity to transfer heat using a refrigerant from one place to another by different heat sources, making buildings clean and environmentally friendly. With the support of the ORNL Laboratory Modernization Division, this project explored and evaluated an innovative solution that uses water-water cost-effective midtemperature heat pump (MTHP) technology to leverage the low-grade waste heat from ORNL Frontier and the data center to deliver 85°C hot water, which replaces hot steam generated using natural gas combustion boilers for water heating or space heating in the buildings of ORNL campus. Two scenarios were studied. In the first scenario, which considered the 5600-5700-5800 complex only, Carrier’s commercial 1,000 kW MTHP technology achieves more than 6,640 MWh/year energy savings, an emission reduction of 858 TCO2e/year CO2, and a payback time of 4.85 years. In the second scenario, which considered the 5600-5700-5800 complex and Buildings 5100, 5200, and 5300, the CO2 emission reduction is 1,483 TCO2e/year, the operating cost savings are $0.21 million annually, and the payback time is 3.74 years. Additionally, a comprehensive HP ShowCase Tool was developed for evaluating the optimal solution to improve sustainability and decarbonization of the buildings on the ORNL campus. The tool is an Excel-based tool integrated with VBA (Visual Basic for Applications) coding. The tool includes collected ORNL campus building information and an MTHP library, which comprises collected commercial and ORNL-defined MTHPs. The tool was used to evaluate the sustainability and decarbonization of the ORNL campus. The tool can be widely used or referenced for heat pump solutions and building decarbonization renovation strategies to modernize ORNL facilities and energy use–intensive equipment to enable efficient, sustainable, and resilient operations in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗