Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DOUBLE BETA DECAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Topological background discrimination in the PandaX-III neutrinoless double beta decay experiment

The PandaX-III experiment plans to search for neutrinoless double beta decay (0ν ββ ) of 136 Xe in the China JinPing underground Laboratory (CJPL). The experiment will use a high pressure gaseous time projection chamber (TPC) to register both the energy and the electron track topology of an event. This article is devoted to demonstrate our particular detector setup capabilities for the identification of 0ν ββ and the consequent background reduction. As software tool we use REST, a framework developed for the reconstruction and simulation of TPC-based detector systems. We study the potential for background reduction by introducing appropriate parameters based on the properties of 0ν ββ events. We exploit for the first time not only the energy density of the electron track-ends, but also the electron scattering angles produced by an electron near the end of its trajectory. To implement this, we have added new algorithms for detector signal and track processing inside REST. Their assessment shows that background can be reduced by about 7 orders of magnitude while keeping 0ν ββ efficiency above 20% for the PandaX-III baseline readout scheme, a two-dimensional 3 mm pitch stripped readout. More generally, we use the potential of REST to handle 2D/3D data to assess the impact on signal-to-background significance at different detector granularities, and to validate the PandaX-III baseline choice. Finally, we demonstrate the additional potential to discriminate surface background events generated at the readout plane in the absence of to, by making use of event parameters related with the diffusion of electrons.

Majorana↗

Double-beta decay investigation with highly pure enriched $^{82}$Se for the LUCIFER experiment

The LUCIFER project aims at deploying the first array of enriched scintillating bolometers for the investigation of neutrinoless double-beta decay of 82 Se. The matrix which embeds the source is an array of ZnSe crystals, where enriched 82 Se is used as decay isotope. The radiopurity of the initial components employed for manufacturing crystals, that can be operated as bolometers, is crucial for achieving a null background level in the region of interest for double-beta decay investigations. In this work, we evaluated the radioactive content in 2.5 kg of 96.3 % enriched 82 Se metal, measured with a high-purity germanium detector at the Gran Sasso deep underground laboratory. The limits on internal contaminations of primordial decay chain elements of 232 Th, 238 U and 235 U are respectively: <61, <110 and <74 μBq/kg at 90 % C.L. The extremely low-background conditions in which the measurement was carried out and the high radiopurity of the 82 Se allowed us to establish the most stringent lower limits on the half-lives of the double-beta decay of 82 Se to 0+1, 2+2 and 2+1 excited states of 82 Kr of 3.4•10 22 , 1.3•10 22 and 1.0•10 22 y, respectively, with a 90 % C.L.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of experiments devoted to searches for 2K capture on {sup 78}Kr and for the double-beta decay of {sup 136}Xe with the aid of proportional counters

A brief description of two low-background setups deployed at the Baksan Neutrino Observatory (Institute for Nuclear Research, Russian Academy of Sciences) and intended for searches for two types of double-beta decay of inert-gas isotopes-2K capture on {sup 78}Kr and the double-beta decay of {sup 136}Xe-is given. The two setups in question have similar structures and employ identical large high-pressure copper proportional counters as detectors. Upon a treatment of data from measurements with krypton samples differing in the content of the isotope {sup 78}Kr, the spectrum for an enriched sample revealed an excess of events at a statistical-significance level of about two standard deviations (2{sigma}). If one attributes this excess to 2K(2{nu}) capture on {sup 78}Kr, the respective half-life is T{sub 1/2} = 1.4{sub -0.7}{sup +2.3} Multiplication-Sign 10{sup 22} yr at a 90% C.L. A treatment of data from measurements with xenon samples differing in content of the isotope {sup 136}Xe led to the appearance of an excess of events in the spectrum for an enriched sample at a statistical-significance level of about 2.2{sigma}. If one assumes that this excess is due to the two-neutrino double-beta decay of {sup 136}Xe, then the respective half-life is T{sub 1/2} = 5.8{sub -1.8}{sup +4.7} Multiplication-Sign 10{sup 21} yr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of scintillation and ionization yield with high-pressure gaseous mixtures of Xe and TMA for improved neutrinoless double beta decay and dark matter searches

The gaseous Xenon(Xe) time projection chamber (TPC) is an attractive detector technique for neutrinoless double beta decay and WIMP dark matter searches. While it is less dense compared to Liquid Xe detectors, it has intrinsic advantages in tracking capability and better energy resolution. The performance of gaseous Xe can be further improved by molecular additives such as trimethylamine(TMA), which is expected to (1) cool down the ionization electrons, (2) convert Xe excitation energy to TMA ionizations through Penning transfer, and (3) produce scintillation and electroluminescence light in a more easily detectable wavelength (300 nm). In order to test the feasibility of the performance improvements with TMA, in this paper we made the first direct measurement of Penning and fluorescence transfer efficiency with gaseous mixtures of Xe and TMA. While we observed a Penning transfer efficiency up to ~35%, we found strong suppression of primary scintillation light with TMA. We also found that the primary scintillation light with Xe and TMA mixture can be well characterized by ~3% fluorescence transfer from Xe to TMA, with further suppression due to TMA self-quenching. No evidence of the scintillation light produced by recombination of TMA ions was found. This strong suppression of scintillation light makes dark matter searches quite challenging, while the possibility of improved neutrinoless double beta decay searches remains open. Finally, this work has been carried out within the context of the NEXT collaboration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Left-Right Symmetry: From the LHC to Neutrinoless Double Beta Decay

The Large Hadron Collider has the potential to probe the scale of left-right symmetry restoration and the associated lepton number violation. Moreover, it offers the hope of measuring the right-handed leptonic mixing matrix. We show how this, together with constraints from lepton flavor violating processes, can be used to make predictions for neutrinoless double beta decay. We illustrate this connection in the case of the type-II seesaw.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors

Neutrinoless double beta decay (0νββ) is one of the most sensitive probes for physics beyond the Standard Model, providing unique information on the nature of neutrinos. In this paper we review the status and outlook for bolometric 0νββ decay searches. We summarize recent advances in background suppression demonstrated using bolometers with simultaneous readout of heat and light signals. We simulate several configurations of a future CUORE-like bolometer array which would utilize these improvements and present the sensitivity reach of a hypothetical next-generation bolometric0νββ experiment. We demonstrate that a bolometric experiment with the isotope mass of about 1 ton is capable of reaching the sensitivity to the effective Majorana neutrino mass (|m ee |) of order 10-20 meV, thus completely exploring the so-called inverted neutrino mass hierarchy region. In conclusion, we highlight the main challenges and identify priorities for an R&D program addressing them.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First demonstration of a TES based cryogenic Li 2 MoO 4 detector for neutrinoless double beta decay search

Cryogenic calorimetric experiments to search for neutrinoless double-beta decay (0vββ) are highly competitive, scalable and versatile in isotope. The largest planned detector array, CUPID, is comprised of about 1500 individual Li 2 100 MoO 4 detector modules with a further scale up envisioned for a follow up experiment (CUPID-1T). In this article, we present a novel detector concept targeting this second stage with a low impedance TES based readout for the Li 2 MoO 4 absorber that is easily mass-produced and lends itself to a multiplexed readout. We present the detector design and results from a first prototype detector operated at the NEXUS shallow underground facility at Fermilab. The detector is a 2-cm-side cube with 21 g mass that is strongly thermally coupled to its readout chip to allow rise-times of ~0.5 ms. This design is more than one order of magnitude faster than present NTD based detectors and is hence expected to effectively mitigate backgrounds generated through the pile-up of two independent two neutrino decay events coinciding close in time. Together with a baseline resolution of 1.95 keV (FWHM) these performance parameters extrapolate to a background index from pile-up as low as 5 • 10 –6 counts/keV/kg/yr in CUPID size crystals. The detector was calibrated up to the MeV region showing sufficient dynamic range for 0vββ searches. In combination with a SuperCDMS HVeV detector this setup also allowed us to perform a precision measurement of the scintillation time constants of Li 2 MoO 4 , which showed a primary component with a fast O(20 μs) time scale. Similar content being viewe

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Radioactivity Crystals for Neutrinoless Double Beta Decay Detectors

The production of crystals needed for rare events physics represent a relatively new, exciting challenge in the field of materials science and engineering. Extremely low concentration of radioactive impurities and very high crystal perfection is required for the crystals to be used in experiments in which the main concerns are the reduction of the background and the use of high sensitivity detectors. A further complication is the fact that for an experiment with a significant discovery potential, relatively large quantities of crystals are needed. The present work makes a review of the general problems related to the production of crystals for rare events physics and gives details related to the production of the TeO{sub 2} crystals needed for the major experiment in this field using bolometric technique, namely the CUORE experiment. The potential use of crystals for future double beta decay experiments is also discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Double beta decay: yesterday, today, tomorrow

After a brief introduction on the main features of Double Beta Decay (DBD) and on its origin, its importance is stressed in view of the recent results of experiments on neutrino oscillations. The present experimental situation is reported with special reference to direct experiments and to the comparison of their results with theory. The expectations of the future experiments aiming to reach the sensitivity indicated by neutrino oscillations in the inverse hierarchy hypothesis are discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Expected sensitivity to 128 Te neutrinoless double beta decay with the CUORE TeO 2 cryogenic bolometers

The CUORE experiment is a ton-scale array of TeO 2 cryogenic bolometers located at the underground Laboratori Nazionali del Gran Sasso of Istituto Nazionale di Fisica Nucleare (INFN), in Italy. The CUORE detector consists of 988 crystals operated as source and detector at a base temperature of ~ 10 mK. Such cryogenic temperature is reached and maintained by means of a custom built cryogen-free dilution cryostat, designed with the aim of minimizing the vibrational noise and the environmental radioactivity. The primary goal of CUORE is the search for neutrinoless double beta decay of 130 Te , but thanks to its large target mass and ultra-low background it is suitable for the study of other rare processes as well, such as the neutrinoless double beta decay of 128 Te. This tellurium isotope is an attractive candidate for the search of this process, due to its high natural isotopic abundance of 31.75%. The transition energy at (866.7 ± 0.7) keV lies in a highly populated region of the energy spectrum, dominated by the contribution of the two-neutrino double beta decay of 130 Te. As the first ton-scale infrastructure operating cryogenic TeO 2 bolometers in stable conditions, CUORE is able to achieve a factor > 10 higher sensitivity to the neutrinoless double beta decay of this isotope with respect to past direct experiments.

128-Te↗

Demonstration of Single-Barium-Ion Sensitivity for Neutrinoless Double-Beta Decay Using Single-Molecule Fluorescence Imaging

Here, a new method to tag the barium daughter in the double beta decay of $^{136}$Xe is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba$^{++}$) resolution at a transparent scanning surface has been demonstrated. A single-step photo-bleach confirms the single ion interpretation. Individual ions are localized with super-resolution ($\sim$2~nm), and detected with a statistical significance of 12.9~$\sigma$ over backgrounds. This lays the foundation for a new and potentially background-free neutrinoless double beta decay technology, based on SMFI coupled to high pressure xenon gas time projection chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of the BiPo-1 prototype for radiopurity measurements for the SuperNEMO double beta decay source foils

The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in 208Tl and 214Bi for the SuperNEMO double beta decay source foils. A modular prototype, called BiPo-1, with 0.8m2 of sensitive surface area, has been running in the Modane Underground Laboratory since February, 2008. The goal of BiPo-1 is to measure the different components of the background and in particular the surface radiopurity of the plastic scintillators that make up the detector. The first phase of data collection has been dedicated to the measurement of the radiopurity in 208Tl. After more than one year of background measurement, a surface activity of the scintillators of Að208TlÞ ¼ 1:5mBq=m2 is reported here. Given this level of background, a larger BiPo detector having 12m2 of active surface area, is able to qualify the radiopurity of the SuperNEMO selenium double beta decay foils with the required sensitivity of Að208TlÞo2mBq=kg (90% C.L.) with a six month measurement.

99 GENERAL AND MISCELLANEOUS↗

Double Beta Decay in Xenon-136. Measuring the Neutrino-Emitting Mode and Searching for Majoron-Emitting Modes

Observations of neutrino flavor oscillations have demonstrated that neutrinos have mass. Since the discovery of these oscillations, much progress has been made at mea- suring the neutrino mass-squared differences and lepton mixing angles that character- ize them. However, the origin and absolute scale of neutrino masses remain unknown. Unique among fermions, neutrinos can be Majorana particles, which could provide an explanation for neutrino masses. Discovery of a hypothetical process known as neutrinoless double beta decay would show that neutrinos are Majorana particles and determine the mass scale for neutrinos. The Enriched Xenon Observatory (EXO) is a series of experiments searching for the neutrinoless double beta decay of 136Xe. The first experiment, EXO-200, began operation in 2011 and makes use of 200 kg of xenon enriched to 80.6% in 136Xe. The analysis presented here makes use of data from EXO-200 to obtain a more precise measurement of the half-life for the two-neutrino-emitting mode of double beta decay than previously reported. The analysis also sets limits on the half-lives for exotic, Majoron-emitting modes of neutrinoless double beta decay. Data from EXO-200 is also used to produce a measurement of the cosmic muon flux at the WIPP under- ground site where EXO-200 is located.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electron-capture branch of 100 Tc and tests of nuclear wave functions for double-β decays.

We present a measurement of the electron-capture branch of 100 Tc. Our value, B(EC) = (2.6 ± 0.4) x 10 -5 , implies that the 100 Mo neutrino absorption cross section to the ground state of 100 Tc is roughly 50% larger than previously thought. Disagreement between the experimental value and QRPA calculations relevant to double-β decay matrix elements persists. We find agreement with previous measurements of the 539.5- and 590.8-keV γ-ray intensities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New generation of double beta decay experiments: are there any limitations?

New generation of experiments to search for neutrinoless double beta decay with sensitivity to effective Majorana neutrino mass on the level of {approx}3-5 meV is discussed. Possible restrictions in achievement of this sensitivity such as: possibility to produce large amount of enriched isotopes, possibility to reach of a very low level of background, energy resolution and possible cost of experiments are considered. It is shown that for realization of so ambitious project 10 tons (or more) of enriched isotope is required. Background index should be on the level {<=}10{sup -5}-10{sup -6} c/kg{center_dot}keV{center_dot}y. In addition, the energy resolution of the detector should be no worse than 1-2%. It is shown that {sup 130}TeO{sub 2} low temperature bolometer could be the most realistic candidate for such an experiment. Under certain conditions experiments with {sup 76}Ge, {sup 100}Mo and {sup 136}Xe can be realized too.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First data from the CUPID-Mo neutrinoless double beta decay experiment

The CUPID-Mo experiment is searching for neutrinoless double beta decay in $^{100}$Mo, evaluating the technology of cryogenic scintillating Li$_{2}^{100}$MoO$_4$ detectors for CUPID (CUORE Upgrade with Particle ID). CUPID-Mo detectors feature background suppression using a dual-readout scheme with Li$_{2}$MoO$_4$ crystals complemented by Ge bolometers for light detection. The detection of both heat and scintillation light signals allows the efficient discrimination of $\alpha$ from $\gamma$&$\beta$ events. In this proceedings, we discuss results from the first 2 months of data taking in spring 2019. In addition to an excellent bolometric performance of 6.7$\,$keV (FWHM) at 2615$\,$keV and an $\alpha$ separation of better than 99.9% for all detectors, we report on bulk radiopurity for Th and U. Finally, we interpret the accumulated physics data in terms of a limit of $T_{1/2}^{0\nu}\,> 3\times10^{23}\,$yr for $^{100}$Mo and discuss the sensitivity of CUPID-Mo until the expected end of physics data taking in early 2020.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Shell Model Studies of Competing Mechanisms to the Neutrinoless Double-Beta Decay in 124 Sn, 130 Te, and 136 Xe

Neutrinoless double-beta decay is a predicted beyond Standard Model process that could clarify some of the not yet known neutrino properties, such as the mass scale, the mass hierarchy, and its nature as a Dirac or Majorana fermion. Should this transition be observed, there are still challenges in understanding the underlying contributing mechanisms. We perform a detailed shell model investigation of several beyond Standard Model mechanisms that consider the existence of right-handed currents. Our analysis presents different venues that can be used to identify the dominant mechanisms for nuclei of experimental interest in the mass A ~ 130 region ( 124 Sn, 130 Te, and 136 Xe). In conclusion, it requires accurate knowledge of nine nuclear matrix elements that we calculate in addition to the associated energy-dependent phase space factors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗