Comparison of RESRAD-Derived External Dose to TLD Dose - 18522

At the Nevada National Security Site, external dose at corrective action sites is generally estimated using environmental thermoluminescent dosimeters (TLDs). These devices integrate the penetrating radiation dose at the location being evaluated. Because these devices will also integrate the external dose from natural sources of penetrating radiation (e.g., cosmic rays and naturally occurring radionuclides in soil), the natural background external dose level as measured by TLDs placed in similar but unaffected areas is subtracted from the gross TLD reading. The use of TLDs to estimate the external dose component of the total effective dose was determined to be the most effective method because the TLDs are exposed for an extended time period and TLDs are compliant with Title 10 Code of Federal Regulations Part 835.402, 'Individual Monitoring,' to monitor individual exposures. At sample locations where no TLD results are available (such as subsurface locations), estimated external dose is calculated from a RESRAD-derived external dose using radionuclide activities measured from soil samples. A comparison of estimated external doses from locations where both TLD data and soil sample data are available is presented herein. This comparison demonstrates that estimated external dose using RESRAD and soil sample radionuclide activities generally results in a significantly lower external dose than by using TLD results. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rectal Dose and Source Strength of the High-Dose-Rate Iridium-192 Both Affect Late Rectal Bleeding After Intracavitary Radiation Therapy for Uterine Cervical Carcinoma

Purpose: The purpose of this study was to reconfirm our previous findings that the rectal dose and source strength both affect late rectal bleeding after high-dose-rate intracavitary brachytherapy (HDR-ICBT), by using a rectal dose calculated in accordance with the definitions of the International Commission on Radiation Units and Measurements Report 38 (ICRU{sub RP}) or of dose-volume histogram (DVH) parameters by the Groupe Europeen de Curietherapie of the European Society for Therapeutic Radiology and Oncology. Methods and Materials: Sixty-two patients who underwent HDR-ICBT and were followed up for 1 year or more were studied. The rectal dose for ICBT was calculated by using the ICRP{sub RP} based on orthogonal radiographs or the DVH parameters based on computed tomography (CT). The total dose was calculated as the biologically equivalent dose expressed in 2-Gy fractions (EQD{sub 2}). The relationship between averaged source strength or the EQD{sub 2} and late rectal bleeding was then analyzed. Results: When patients were divided into four groups according to rectal EQD{sub 2} ({>=} or <median dose) and source strength ({>=} or <2.4 cGy.m{sup 2}.h{sup -1}), the group with both a high EQD{sub 2} and a high source strength showed a significantly greater probability of rectal bleeding for ICRU{sub RP}, D{sub 2cc}, and D{sub 1cc}. The patients with a median rectal dose above the threshold level did not show a greater frequency of rectal bleeding unless the source strength exceeded 2.4 cGy.m{sup 2}.h{sup -1}. Conclusions: Our results obtained with data based on ICRU{sub RP} and CT-based DVH parameters indicate that rectal dose and source strength both affect rectal bleeding after HDR-ICBT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Coefficients for Internal Dose Assessments for Exposure to Radioactive Fallout

This paper presents values as well as the bases for calculating internal dose coefficients suitable for estimating organ doses from the exposure to radioactive fallout that could result from the detonation of a nuclear fission device. The 34 radionuclides discussed are the same as those given in a priority list of radionuclides for fallout dose assessments presented in a companion overview paper. The radionuclides discussed are those that are believed to account for a preponderance of the organ doses that might be received by intake by persons of all ages (including in utero and via breast feeding for infants) following exposure to radioactive fallout. The presented dose coefficients for ingestion account for age and include modifications for variations in solubility with distance as discussed previously in the literature, and those for inhalation similarly account for age, solubility, and particle sizes that would be relevant at various distances of exposure as discussed in a companion paper on ingestion dose methods. The proposed modifications peculiar to radioactive fallout account for systematic changes in solubility and particle sizes with distance from the site of detonation, termed here as the region of “local fallout” and the region “beyond local fallout.” Brief definitions of these regions are provided here with more detailed discussion in a companion paper on estimating deposition of fallout radionuclides. This paper provides the dose coefficients for ingestion and inhalation (for particle sizes of 1 μm, 5 μm, 10 μm, and 20 μm) for the region “local fallout.” These dose coefficients for “local fallout” are specific for particles formed in a nuclear explosion that can be large and have radionuclides, particularly the more refractory ones, distributed throughout the volume where the radionuclide has reduced solubility. The dose coefficients for the region “beyond local fallout” are assumed to be the ones published by the International Commission on Radiological Protection (ICRP) in 1995. Comparisons of the presented dose coefficients are made with values published by the ICRP.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

TH-A-19A-03: Impact of Proton Dose Calculation Method On Delivered Dose to Lung Tumors: Experiments in Thorax Phantom and Planning Study in Patient Cohort

Purpose: Evaluate Monte Carlo (MC) dose calculation and the prediction of the treatment planning system (TPS) in a lung phantom and compare them in a cohort of 20 lung patients treated with protons. Methods: A 2-dimensional array of ionization chambers was used to evaluate the dose across the target in a lung phantom. 20 lung cancer patients on clinical trials were re-simulated using a validated Monte Carlo toolkit (TOPAS) and compared to the TPS. Results: MC increases dose calculation accuracy in lung compared to the clinical TPS significantly and predicts the dose to the target in the phantom within ±2%: the average difference between measured and predicted dose in a plane through the center of the target is 5.6% for the TPS and 1.6% for MC. MC recalculations in patients show a mean dose to the clinical target volume on average 3.4% lower than the TPS, exceeding 5% for small fields. The lower dose correlates significantly with aperture size and the distance of the tumor to the chest wall (Spearman's p=0.0002/0.004). For large tumors MC also predicts consistently higher V{sub 5} and V{sub 10} to the normal lung, due to a wider lateral penumbra, which was also observed experimentally. Critical structures located distal to the target can show large deviations, though this effect is very patient-specific. Conclusion: Advanced dose calculation techniques, such as MC, would improve treatment quality in proton therapy for lung cancer by avoiding systematic overestimation of target dose and underestimation of dose to normal lung. This would increase the accuracy of the relationships between dose and effect, concerning tumor control as well as normal tissue toxicity. As the role of proton therapy in the treatment of lung cancer continues to be evaluated in clinical trials, this is of ever-increasing importance. This work was supported by National Cancer Institute Grant R01CA111590.

60 APPLIED LIFE SCIENCES↗

Individual doses for super cohort members exposed to atmospheric radioiodine from the Mayak releases with an emphasis on prenatal doses

Time-dependent thyroid doses were reconstructed for 45,837 members of the Southern Urals Population Exposed to Radiation Cohort (SUPER-C) living in the region around the Mayak Production Association facilities in Russia from 131I released to the atmosphere from all relevant exposure pathways. The dose calculations are implemented in a Monte Carlo framework that produces best estimates and stochastic realizations of dose time-histories. The mean thyroid dose from 131I for SUPER-C members was 195 mGy; the median was 65 mGy. Overall, 131I-thyroid doses for about 3.6% of SUPER-C members were larger than 1 Gy. For children born in 1940-1950, the dose was about 10% higher than in previous studies because doses during the prenatal period for 9,117 individuals are included in the current work. Half of the individuals born in the region in 1950–1960 who remained in the study domain through 1972 received 9.4% or more of their total dose during the prenatal period. SUPER-C members residing in areas contaminated by discharges of liquid radioactive releases into the Techa River and the Kyshtym Accident in 1957 received 80% of their thyroid dose from airborne 131I emissions. The uncertainty in the 131I dose estimates is low enough for this approach to be used in regional epidemiological studies.

Dose assessment, 131I, airborne radioactivity, thy↗

The effects of dose, dose rate, and irradiation type and their equivalence on radiation-induced segregation in binary alloy systems via phase-field simulations

Radiation-induced segregation is a phenomenon commonly observed in many alloys which consists of the redistribution of elements (solute or interstitial impurities) under irradiation. The onset and development of radiation-induced segregation can only occur when a sufficient flux of defects is sustained and defect sinks are present. Irradiation dose, dose rate, and particle types all affect defect flux. In this work, we employ a phase-field model to examine the effects of dose, dose rate, and type of incident particles on radiation-induced segregation behavior in a model binary alloy. The phase-field model takes into account the formation and evolution of point defects as well as defect clusters, the diffusion and clustering of alloy species, the presence of additional extrinsic defect sinks in the form of dislocations, and two different methods of radiation-damage insertion, which are intended to simulate either light-ion/electron irradiation via Frenkel pairs or heavy-ion irradiation in the form of cascades. Our results show a dose-rate and particle-type dependence on the amount of solute segregation. We show that the material systems exposed to higher dose rates are less subjected to solute segregation at equivalent doses. We also show that such dose-rate-dependence behavior is due to a delay of the incubation dose at which radiation-induced segregation effectively starts. Particle type and the presence of dislocations can accentuate this behavior. Our model predictions correlate with many experimental observations made over the years on radiation-induced segregation providing credence to the simulation results. The methodology presented in this study allows for a first-order prediction of the dose rate at which proxy irradiation experiments could be performed to approximate radiation-induced segregation behaviors seen in targeted irradiation conditions.

36 MATERIALS SCIENCE↗

Dose and dose averaged LET comparison of {sup 1}H, {sup 4}He, {sup 6}Li, {sup 8}Be, {sup 10}B, {sup 12}C, {sup 14}N, and {sup 16}O ion beams forming a spread-out Bragg peak

Purpose: Modern clinical accelerators are capable of producing ion beams from protons up to neon. This work compares the depth dose distribution and corresponding dose averaged linear energy transfer (LET) distribution, which is related to the biological effectiveness, for different ion beams ({sup 1}H, {sup 4}He, {sup 6}Li, {sup 8}Be, {sup 10}B, {sup 12}C, {sup 14}N, and {sup 16}O) using multi-energetic spectra in order to configure spread-out Bragg peaks (SOBP). Methods: Monte Carlo simulations were performed in order to configure a 5 cm SOBP at 8 cm depth in water for all the different ion beams. Physical dose and dose averaged LET distributions as a function of depth were then calculated and compared. The superposition of dose distribution of all ions is also presented for a two opposing fields configuration. Additional simulations were performed for {sup 12}C beams to investigate the dependence of dose and dose averaged LET distributions on target depth and size, as well as beam configuration. These included simulations for a 3 cm SOBP at 7, 10, and 13 cm depth in water, a 6 cm SOBP at 7 depth in water, and two opposing fields of 6 cm SOBP. Results: Alpha particles and protons present superior physical depth dose distributions relative to the rest of the beams studied. Dose averaged LET distributions results suggest higher biological effectiveness in the target volume for carbon, nitrogen and oxygen ions. This is coupled, however, with relatively high LET values--especially for the last two ion species--outside the SOBP where healthy tissue would be located. Dose averaged LET distributions for {sup 8}Be and {sup 10}B beams show that they could be attractive alternatives to {sup 12}C for the treatment of small, not deeply seated lesions. The potential therapeutic effect of different ion beams studied in this work depends on target volume and position, as well as the number of beams used. Conclusions: The optimization of beam modality for specific tumor cites remains an open question that warrants further investigation and clinically relevant results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Incorporating single-side sparing in models for predicting parotid dose sparing in head and neck IMRT

Purpose: Sparing of single-side parotid gland is a common practice in head-and-neck (HN) intensity modulated radiation therapy (IMRT) planning. It is a special case of dose sparing tradeoff between different organs-at-risk. The authors describe an improved mathematical model for predicting achievable dose sparing in parotid glands in HN IMRT planning that incorporates single-side sparing considerations based on patient anatomy and learning from prior plan data. Methods: Among 68 HN cases analyzed retrospectively, 35 cases had physician prescribed single-side parotid sparing preferences. The single-side sparing model was trained with cases which had single-side sparing preferences, while the standard model was trained with the remainder of cases. A receiver operating characteristics (ROC) analysis was performed to determine the best criterion that separates the two case groups using the physician's single-side sparing prescription as ground truth. The final predictive model (combined model) takes into account the single-side sparing by switching between the standard and single-side sparing models according to the single-side sparing criterion. The models were tested with 20 additional cases. The significance of the improvement of prediction accuracy by the combined model over the standard model was evaluated using the Wilcoxon rank-sum test. Results: Using the ROC analysis, the best single-side sparing criterion is (1) the predicted median dose of one parotid is higher than 24 Gy; and (2) that of the other is higher than 7 Gy. This criterion gives a true positive rate of 0.82 and a false positive rate of 0.19, respectively. For the bilateral sparing cases, the combined and the standard models performed equally well, with the median of the prediction errors for parotid median dose being 0.34 Gy by both models (p = 0.81). For the single-side sparing cases, the standard model overestimates the median dose by 7.8 Gy on average, while the predictions by the combined model differ from actual values by only 2.2 Gy (p = 0.005). Similarly, the sum of residues between the modeled and the actual plan DVHs is the same for the bilateral sparing cases by both models (p = 0.67), while the standard model predicts significantly higher DVHs than the combined model for the single-side sparing cases (p = 0.01). Conclusions: The combined model for predicting parotid sparing that takes into account single-side sparing improves the prediction accuracy over the previous model.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-A-17A-04: Development of An Ultra-Fast Monte Carlo Dose Engine for High Dose Rate Brachytherapy

Purpose: Current clinical brachytherapy dose calculations are based on AAPM TG43 guidelines, which approximate the patient geometry as a large water phantom. This ignores heterogeneities and tends to overestimate skin dose. Although Monte Carlo (MC) dose calculations have been recognized as the most accurate method, its associated long computational time is a major bottleneck for routine clinical applications. This work aims to develop a GPU-based ultra-fast MC dose engine (gBMC) for HDR brachytherapy to provide clinical users with accurate sub-minute dose calculations. Methods: Standard photon transport with discrete events including: Compton scattering, Rayleigh scattering and Photoelectric effect, was implemented. Secondary electrons were transported under the continuous slowing down approximation. To reduce the GPU thread divergence, photons and electrons were separately transported. Transport of photons was grouped according to energy. The source model in gBMC can be either a phase-space file generated using Geant4 or a parameterized source model. This dose engine was validated against TG43 in a water phantom and against Geant4 calculations in heterogeneous patient geometries. Results: A phase space file was generated for the Varian VS2000 Ir-192 source. In a water phantom, the calculated radial dose function was within 0.6% of the TG43 calculations for radial distances from 1 cm to 20 cm. The anisotropy functions were within 1% for radial distances from 1 cm to 20 cm except for polar angles larger than 173°. Local point-dose differences were within 2%. In a Mammosite breast cancer case with 22 dwell locations, gBMC and Geant4 isodose lines compared well. The computation time was about 28 seconds using the phase-space file source and 20 seconds using the parameterized source to simulate 1 billion particles, yielding less than 1% statistical uncertainty. Conclusion: The gBMC dose engine makes it possible to use fast and accurate MC dose calculations for clinical work.

60 APPLIED LIFE SCIENCES↗

Accuracy of a dose-area product compared to an absorbed dose to water at a point in a 2 cm diameter field

Purpose: Graphite calorimeters with a core diameter larger than the beam can be used to establish dosimetric references in small fields. The dose-area product (DAP) measured can theoretically be linked to an absorbed dose at a point by the determination of a profile correction. This study aims at comparing the DAP-based protocol to the usual absorbed dose at a point protocol in a 2 cm diameter field for which both references exist. Methods: Two calorimeters were used, respectively, with a sensitive volume of 0.6 cm (for the absorbed dose at a point measurement) and 3 cm diameter (for the DAP measurement). Profile correction was calculated from a 2D dose mapping using three detectors: a PinPoint chamber, a synthetic diamond, and EBT3 films. A specific protocol to read EBT3 films was implemented and the dose-rate and energy dependences were studied to assure a precise measurement, especially in the penumbra and out-of-field regions. Results: EBT3 films were found independent on dose rates over the range studied but showed a strong under-response (18%) at low energies. Depending on the dosimeter used for calculating the profile correction, a deviation of 0.8% (PinPoint chamber), 0.9% (diamond), or 1.9% (EBT3 films) was observed between the calibration coefficient derived from DAP measurements and the one directly established in terms of absorbed dose to water at a point. Conclusions: The DAP method can currently be linked to the classical dosimetric reference system based in an absorbed dose at a point only with a confidence interval of 95% (k = 2). None of the detectors studied can be used to determine an absorbed dose to water at a point from a DAP measurement with an uncertainty smaller than 1.2%.

60 APPLIED LIFE SCIENCES↗

SU-F-T-474: Evaluation of Dose Perturbation, Temperature and Sensitivity Variation With Accumulated Dose of MOSFET Detector

Purpose: The use of mega voltage gamma and x-ray sources with their skin sparring qualities in radiation therapy has been a boon in relieving patient discomfort and allowing high tumor doses to be given with fewer restrictions due to radiation effects in the skin. However, high doses given to deep tumors may require careful consideration of dose distribution in the buildup region in order to avoid irreparable damage to the skin. Methods: To measure the perturbation of MOSFET detector in Co60,6MV and 15MV the detector was placed on the surface of the phantom covered with the brass build up cap. To measure the effect of temperature the MOSFET detector was kept on the surface of hot water polythene container and the radiation was delivere. In order to measure the sensitivity variation with accumulated dose Measurements were taken by delivering the dose of 200 cGy to MOSFET until the MOSFET absorbed dose comes to 20,000 cGy Results: the Measurement was performed by positioning the bare MOSFET and MOSFET with brass build up cap on the top surface of the solid water phantom for various field sizes in order to find whether there is any attenuation caused in the dose distribution. The response of MOSFET was monitored for temperature ranging from 42 degree C to 22 degree C. The integrated dose dependence of MOSFET dosimeter sensitivity over different energy is not well characterized. This work investigates the dual-bias MOSFET dosimeter sensitivity response to 6 MV and 15 MV beams. Conclusion: From this study it is observed that unlike diode, bare MOSFET does not perturb the radiation field.. It is observed that the build-up influences the temperature dependency of MOSFET and causes some uncertainty in the readings. In the case of sensitivity variation with accumulated dose MOSFET showed higher sensitivity with dose accumulation for both the energies.

60 APPLIED LIFE SCIENCES↗

SU-F-T-340: Direct Editing of Dose Volume Histograms: Algorithms and a Unified Convex Formulation for Treatment Planning with Dose Constraints

Purpose: To develop a procedure for including dose constraints in convex programming-based approaches to treatment planning, and to support dynamic modification of such constraints during planning. Methods: We present a mathematical approach that allows mean dose, maximum dose, minimum dose and dose volume (i.e., percentile) constraints to be appended to any convex formulation of an inverse planning problem. The first three constraint types are convex and readily incorporated. Dose volume constraints are not convex, however, so we introduce a convex restriction that is related to CVaR-based approaches previously proposed in the literature. To compensate for the conservatism of this restriction, we propose a new two-pass algorithm that solves the restricted problem on a first pass and uses this solution to form exact constraints on a second pass. In another variant, we introduce slack variables for each dose constraint to prevent the problem from becoming infeasible when the user specifies an incompatible set of constraints. We implement the proposed methods in Python using the convex programming package cvxpy in conjunction with the open source convex solvers SCS and ECOS. Results: We show, for several cases taken from the clinic, that our proposed method meets specified constraints (often with margin) when they are feasible. Constraints are met exactly when we use the two-pass method, and infeasible constraints are replaced with the nearest feasible constraint when slacks are used. Finally, we introduce ConRad, a Python-embedded free software package for convex radiation therapy planning. ConRad implements the methods described above and offers a simple interface for specifying prescriptions and dose constraints. Conclusion: This work demonstrates the feasibility of using modifiable dose constraints in a convex formulation, making it practical to guide the treatment planning process with interactively specified dose constraints. This work was supported by the Stanford BioX Graduate Fellowship and NIH Grant 5R01CA176553.

60 APPLIED LIFE SCIENCES↗

Dose Rate Effects on Degradation of Nuclear Power Plant Electrical Cable Insulation at a Common Dose

The intent of this report is to address an identified knowledge gap in relating accelerated aging of nuclear electrical cables to service aging: dose rate effects (DRE). Here, DRE refer to gamma radiation-induced polymer degradation being a function of dose rate in addition to total absorbed dose. The concern raised is that historical qualification conducted at higher dose rates to simulate service lifetime may underestimate insulation degradation that occurs at lower dose rates in service. In the work described herein, common nuclear cable insulation materials—cross-linked polyethylene (XLPE) and ethylene propylene diene elastomer (EPDM)—were subjected to accelerated aging at ambient temperature (26°C) at different gamma dose rates of 100, 200 and 1800 Gy/h for select exposure durations to achieve constant total doses of 170, 210 and 300 kGy to evaluate DRE. First, the cable insulation material types investigated are described. Then, the accelerated aging experimental process involving gamma irradiation applied to the insulation specimens at room temperature and different dose rates is discussed. Then, the experimental characterization techniques used to perform this work are elucidated. These include elongation at break (EAB), mass change, yellowness index (YI), carbonyl index (CI), density, indenter modulus (IM), and relaxation constant (t). Theory of polymer degradation is discussed, and characterization results and discussion are provided. Finally, concluding remarks are made. The findings from this work and cited prior work reveal that DRE are material dependent, even between similar material categories (e.g., XLPE). In the case of the EPDM studied, degradation of ductility was observed to be greater at higher dose rate for the same total dose, indicating accelerated gamma aging to be more conservative than extended aging. Thus, conclusions regarding the conservatism of historical qualification likely require additional consideration for specific materials and conditions in question. The results of this study support the contention that, due to inherent limitations and uncertainties associated with prediction of cable remaining useful life from accelerated aging experiments, trending of installed cable insulation health status will be more practical and useful for safe and efficient cable aging management repair and replace decisions than lifetime prediction from historical qualification. The combination of material robustness demonstrated by the qualification process and ongoing monitoring of cable health status combine to provide confidence in continued safe use of existing nuclear cables. Additional research into effective and efficient condition monitoring methods for non-destructive evaluation of installed cables is needed to support aging cable management, including material studies to inform interpretation of measured results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

HDRMC, an accelerated Monte Carlo dose calculator for high dose rate brachytherapy with CT-compatible applicators

Purpose: To present a new accelerated Monte Carlo code for CT-based dose calculations in high dose rate (HDR) brachytherapy. The new code (HDRMC) accounts for both tissue and nontissue heterogeneities (applicator and contrast medium). Methods: HDRMC uses a fast ray-tracing technique and detailed physics algorithms to transport photons through a 3D mesh of voxels representing the patient anatomy with applicator and contrast medium included. A precalculated phase space file for the{sup 192}Ir source is used as source term. HDRM is calibrated to calculated absolute dose for real plans. A postprocessing technique is used to include the exact density and composition of nontissue heterogeneities in the 3D phantom. Dwell positions and angular orientations of the source are reconstructed using data from the treatment planning system (TPS). Structure contours are also imported from the TPS to recalculate dose-volume histograms. Results: HDRMC was first benchmarked against the MCNP5 code for a single source in homogenous water and for a loaded gynecologic applicator in water. The accuracy of the voxel-based applicator model used in HDRMC was also verified by comparing 3D dose distributions and dose-volume parameters obtained using 1-mm{sup 3} versus 2-mm{sup 3} phantom resolutions. HDRMC can calculate the 3D dose distribution for a typical HDR cervix case with 2-mm resolution in 5 min on a single CPU. Examples of heterogeneity effects for two clinical cases (cervix and esophagus) were demonstrated using HDRMC. The neglect of tissue heterogeneity for the esophageal case leads to the overestimate of CTV D90, CTV D100, and spinal cord maximum dose by 3.2%, 3.9%, and 3.6%, respectively. Conclusions: A fast Monte Carlo code for CT-based dose calculations which does not require a prebuilt applicator model is developed for those HDR brachytherapy treatments that use CT-compatible applicators. Tissue and nontissue heterogeneities should be taken into account in modern HDR brachytherapy planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-165: Characterization of Dose Distributions in High-Dose-Rate Surface Brachytherapy

Purpose: To characterize dose distributions in high-dose-rate(HDR) surface brachytherapy using an Ir-125 source for different geometries, field sizes and topology of the clinical targets(CT). To investigate the depth doses at the central axis(CAX), edges of the treatment fields(E), and lateral dose distributions(L) present when using flap applicators in skin cancer treatments. Methods: When malignancies diagnosed on the skin are treated, various geometries of the CT require proper adaptation of the flap or custom-made applicators to the treatment site. Consequently, the dose at the depth on CAX and field edges changes with variation of the curvatures and size of the applicators. To assess the dose distributions, we created a total of 10 treatment plans(TP) for 10×10 and 20×20 field sizes(FS) with a step size of 1cm. The geometry of the applicators was: planar(PA), curved to 30(CA30) and 60(CA60) degrees with respect to the CAX, half-cylinder(HC), and cylindrical shape(CS). One additional TP was created in which the applicators were positioned to form a dome shape(DS) with a diameter of 16cm. This TP was used to emulate treatment of the average sized scalp. All TPs were optimized to deliver a prescription dose at 8mm equidistantly from the planes containing the dwell positions. This optimization is equivalent to the clinical arrangement since the SSD for the flap applicators is 5mm and the prescription depth is 3mm in the majority of clinical cases. Results: The depths (in mm) of the isodose lines were: FS(10×10):PA[90%(9.1CAX,8.0E,7.6L),50%(28.3CAX,20E,17.3L), 25%(51.1CAX,40E,27L)],CA30[90%(10.3CAX,8.2E,7.9L),50%(32.1CAX, 16.2E,15.8L),25%(61.3CAX,36.7E,31.8L)],CA60[90%(12.2CAX,6.1E,6.3L ),50%(47CAX,14E,16.6L),25%(70.8CAX,31.9E,35.4L)],HC[90%(11.1CA X,6.3E,7.3L),50%(38.3CAX,14.6E,16.1L),25%(66.2CAX,33.8E,34.2L)];FS (20×20):PA[90%(11.1CAX,9.0E,7.0L),50%(34.4CAX,21.9E,15.3L),25%(7 0.4CAX,50.9E,34.8L)],CA30[90%(10.9CAX,7.5E,7.1L),50%(38.8CAX,16. 7E,15.4L),25%(80.7CAX,39.9E,35.7L)],HC[90%(11.1CAX,10.9E,10.6L),5 0%(34.4CAX,38.8E,47.2L),25%(70.4CAX,80.7E,96.6L);DS[90%(12.1CA X,8.5E,6.8L),50%(60.6CAX,17.7E,15.8L),25%(109.6CAX,40.3E,34.3L)]. Conclusion: These results can be used for the approximate calculation and quick assessment of the radiation dose to the organs-at-risk at depth (heart,brain,thyroid, optical nerve) or at the surface distance from the CT (breast,eyes, gonads), and only the geometry of the CT needs to be measured. Understanding of the dose distributions in HDR surface brachytherapy may improve clinical decision making process.

60 APPLIED LIFE SCIENCES↗

SU-E-T-347: Effect of MLC Leaf Position Inaccuracy On Dose Distribution for Spinal SBRT with Different Energies and Dose Rates

Purpose: To evaluate dosimetric impact of spinal SBRT when MLC leaf positions deviate from planning positions for different energies and doserates. Methods and Materials: 18 localized spinal metastases patients were selected for SBRT using IMRT planning with 9 posterior beams delivered at gantry angles ranging between 100°–260°. A modern linear accelerator(Varian Turebeam STX with HDMLC 2.5 mm thick leaf at isocenter) IMRT plans were generated using both 6X and 6X-FFF(Flattening filter free) beams with a nominal prescription dose of 6 Gy/fraction to PTV. Doserates ranging from 200–600 MU/min for 6X and 400–1400 MU/min for 6X-FFF, with 200 increments were examined. A fixed amount(0.3, 0.5, 1, and 2 mm) of MLC-leaf position deviation was simulated to each plan under following conditions: 1)only along X1 collimator; 2)with increments at both X1 and X2 collimator directions;3)with reductions at both X1 and X2 collimator directions. Dose was recalculated for each modified plans. Both original and modified plans were delivered using Turebeam STX machine and measured using both portal dosimetry and a 3D dosimeter(Delta4 of ScandiDos). Each field’s Result were compared using following three parameters: the 95% iso-dose level Conformal Index(95%CI), the spinal cord maximum dose(SCDmax), and the planned target volume(PTV) mean dose. Results: Dosimetric impacts on the 95%CI, SCDmax and the PTV mean dose are: 1)negligible if MLC-leaf position deviation only along a single collimator direction ≥1.0 mm,2)substantial if MLC-leaf position increment along both collimator directions ≥0.3 mm(95% CI decreases while SCDmax and PTV mean-dose increase), 3)substantial if MLC-leaf position reduction along both collimator directions ≥0.3 mm(95% CI first increases and then decreases while SCDmax and PTV mean-dose decrease). Different energies and doserates demonstrated comparable dosimetric impacts. Conclusion: Substantial dose deviations could happen for spinal SBRT using IMRT plan with HD-MLC if leaf position deviation ≥0.3 mm. The effects of different energy and doserate are negligible.

60 APPLIED LIFE SCIENCES↗

A Comparison of As-loaded Dose Calculations to Measured Dose Rates

Demonstrating that the radiation dose fields surrounding spent nuclear fuel (SNF) storage and transportation systems meet the applicable limits set forth in 10 CFR 72 for storage and 10 CFR 71 for transportation is essential for the safe handling of radioactive material. The Used Nuclear Fuel-Storage, Transportation, and Disposal Analysis Resource and Data System (UNF-ST&DARDS) [2] is used to provide realistic estimates of SNF-related safety margins. The UNF-ST&DARDS dose rate analysis approach differs from that used in typical licensing approaches, which use design-basis assemblies with bounding source term characteristics to demonstrate the packaging design complies with the regulations. These bounding licensing approaches can increase the time needed to qualify fuel for loading into dry storage and the time a loaded system must wait prior to transportation. UNF-ST&DARDS dose rate assessments allow quantification of realistic, uncredited safety margins associated with actual fuel loading compared with the regulatory limits. While realistic estimation of the dose field surrounding SNF systems may allow for additional flexibility in operations, it is essential to understand how these predictions compare to measured doses. The U.S. Department of Energy Office of Integrated Waste Management and the Prairie Island Indian Community conducted a transportation dose assessment to estimate the site-specific incident-free radiation doses from shipping SNF by rail from the Prairie Island Nuclear Generating Plant (PINGP) through the Prairie Island Indian Community Reservation and Trust Land [5,6]. For that effort, the dose rates were obtained for 50 TN-40 and TN-40HT systems in storage configurations. This work compares the predicted dose rates from UNF-ST&DARDS as-loaded calculations with dose rates measured from 50 SNF storage systems at PINGP. The remainder of this paper discusses the data obtained for the evaluation, the modeling methods, and the results of the calculations.

spent nuclear fuel (SNF), UNF-ST&DARDS, Validation↗

Does Incidental Irradiation With Doses Below 50 Gy Effectively Reduce Isolated Nodal Failures in Non-Small-Cell Lung Cancer: Dose-Response Relationship

Purpose: To evaluate the dose-response relationship for a wide range of doses lower than 50 Gy delivered to the hilar and mediastinal lymph node stations from incidental irradiation in 220 patients with non-small-cell lung cancer (NSCLC) treated with three-dimensional conformal radiotherapy. The endpoint was isolated nodal recurrence (INR) in stations that were initially negative. Methods and Materials: The individual responses of 2596 nodal stations were analyzed. Different fractionation schedules were used in different patients. Total prescribed tumor doses ranged from 52 Gy to 74 Gy given over 16-56 days. There were 1198 nodal stations (46%) within and 1398 stations beyond the elective nodal irradiation (ENI) volumes. The INR incidence was estimated for six dose levels ranging from 5 {+-} 5 Gy to {>=}56 Gy. Results: There were a total of 25 INRs in 17 patients (8%). The incidence of INR within the electively treated volumes was 0.58%, compared with 1.28% in nodal stations beyond the ENI. Almost 80% of the INRs occurred during 10 months of follow-up. A strong dose-response relationship was seen for the lower 'incidental' doses, most of which were less than 50 Gy. As the dose increased from 5 {+-} 5 Gy to 40 {+-} 5 Gy, the rate of freedom from INR increased from 12% to 76% (p = 0.005). Conclusions: There is evidence of a dose-response relationship between a reduction in the rate of INR and doses lower than 50 Gy. This suggests that incidental irradiation can eradicate at least some subclinical metastases in regional lymph nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗