Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Nucleon-gold collisions at 200A GeV using tagged d + Au interactions in the PHOBOS detector

Forward calorimetry in the PHOBOS detector has been used to study charged hadron production in d+Au, p+Au, and n+Au collisions at √s NN =200GeV. The forward proton calorimeter detectors are described and a procedure for determining collision centrality with these detectors is detailed. The deposition of energy by deuteron spectator nucleons in the forward calorimeters is used to identify p+Au and n+Au collisions in the data. A weighted combination of the yield of p+Au and n+Au is constructed to build a reference for Au+Au collisions that better matches the isospin composition of the gold nucleus. The p T and centrality dependence of the yield of this improved reference system is found to match that of d+Au. The shape of the charged-particle transverse momentum distribution is observed to extrapolate smoothly from p+p¯ to central d+Au as a function of the charged-particle pseudorapidity density. The asymmetry of positively and negatively charged hadron production in p+Au is compared to that of n+Au. No significant asymmetry is observed at midrapidity. In conclusion, these studies augment recent results from experiments at the CERN Large Hadron Collider and BNL Relativistic Heavy Ion Collider facilities to give a more complete description of particle production in p+A and d+A collisions, essential for the understanding the medium produced in high-energy nucleus-nucleus collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Toward Trustworthy Detectors Detector Characterization for SuperCDMS SNOLAB Commissioning

SuperCDMS SNOLAB is a next generation direct detection experiment searching for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As commissioning begins, establishing stable, predictable detector response to energy deposits is a prerequisite for future physics analysis. This work studies detector stability and calibration for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium) and det 11 and det 14 (silicon), using Barium-133 calibration data (356 keV gamma ray reference) and low background data (ambient radiation, no external source). The Ba-133 data show no distinct line at the expected energy, and the low background data show a baseline that drifts and oscillates rather than remaining flat, consistently across multiple channels, suggesting a shared, detector wide cause. These observations point to the cryogenic support system as the likely source, since small temperature fluctuations could couple into the temperature sensitive detectors, informing the ongoing commissioning effort.

O'Hanlon, Vika [Skidmore Coll.]↗

DETECTING THE SUPERNOVA BREAKOUT BURST IN TERRESTRIAL NEUTRINO DETECTORS

We calculate the distance-dependent performance of a few representative terrestrial neutrino detectors in detecting and measuring the properties of the ν{sub e} breakout burst light curve in a Galactic core-collapse supernova. The breakout burst is a signature phenomenon of core collapse and offers a probe into the stellar core through collapse and bounce. We examine cases of no neutrino oscillations and oscillations due to normal and inverted neutrino-mass hierarchies. For the normal hierarchy, other neutrino flavors emitted by the supernova overwhelm the ν{sub e} signal, making a detection of the breakout burst difficult. For the inverted hierarchy (IH), some detectors at some distances should be able to see the ν{sub e} breakout burst peak and measure its properties. For the IH, the maximum luminosity of the breakout burst can be measured at 10 kpc to accuracies of ∼30% for Hyper-Kamiokande (Hyper-K) and ∼60% for the Deep Underground Neutrino Experiment (DUNE). Super-Kamiokande (Super-K) and Jiangmen Underground Neutrino Observatory (JUNO) lack the mass needed to make an accurate measurement. For the IH, the time of the maximum luminosity of the breakout burst can be measured in Hyper-K to an accuracy of ∼3 ms at 7 kpc, in DUNE to ∼2 ms at 4 kpc, and JUNO and Super-K can measure the time of maximum luminosity to an accuracy of ∼2 ms at 1 kpc. Detector backgrounds in IceCube render a measurement of the ν{sub e} breakout burst unlikely. For the IH, a measurement of the maximum luminosity of the breakout burst could be used to differentiate between nuclear equations of state.

79 ASTRONOMY AND ASTROPHYSICS↗

Spiral biasing adaptor for use in Si drift detectors and Si drift detector arrays

A drift detector array, preferably a silicon drift detector (SDD) array, that uses a low current biasing adaptor is disclosed. The biasing adaptor is customizable for any desired geometry of the drift detector single cell with minimum drift time of carriers. The biasing adaptor has spiral shaped ion-implants that generate the desired voltage profile. The biasing adaptor can be processed on the same wafer as the drift detector array and only one biasing adaptor chip/side is needed for one drift detector array to generate the voltage profiles on the front side and back side of the detector array.

36 MATERIALS SCIENCE↗

High dynamic range CdTe mixed-mode pixel array detector (MM-PAD) for kilohertz imaging of hard x-rays

A hard x-ray, high-speed, high dynamic range scientific x-ray imager is described. The imager is based on the mixed-mode pixel array detector (MM-PAD) readout chip coupled to a 750 µm thick cadmium telluride (CdTe) sensor. The full imager is a 2 × 3 tiled array of MM-PAD sensor/readout chip hybrids. CdTe improves detection for high energy x-rays as compared to silicon sensors, enabling efficient x-ray imaging to extend to >100 keV. The detector is capable of 1 kHz imaging and in-pixel circuitry has been designed to allow for well depths of greater than 4 × 10 6 80 keV x-rays. Here, a charge integrating front-end allows for quantitative measurement of high flux x-ray images beyond the capabilities of photon counting detectors. Detector performance is summarized and experimental measurements are presented.

99 GENERAL AND MISCELLANEOUS↗

Detector Characterization for Quantitative Spectral Radiography of Uranium Powder Samples

Pacific Northwest National Laboratory (PNNL) is developing a prototype spectral x-ray radiography (SpecX) non-destructive assay system for noninvasive material mass quantification of uranium-bearing powders. The SpecX system uses a custom material estimation algorithm, which requires a high-fidelity pixel-by-pixel detector response model for accurate quantification. We performed a detailed characterization and built a model of a High-Energy X-ray Imaging Technology (HEXITEC) CdTe pixelated spectral detector. Here we present the detector characterization which led to that model, including a determination of the pixel-wise energy calibration, the detection efficiency, the detector uniformity, the detector stability, and a comparison of methods to remove charge-shared events.

spectral X-ray radiography, pixelated detector, ca↗

Comparative study of ionization chamber detectors vis-a-vis a CCD detector for dispersive XAS measurement in transmission geometry

We have designed and fabricated parallel plate ionization chamber detectors and voltage vs. current characteristics (V-I curve) of the detectors were recorded with synchrotron radiation to qualify for use in X-ray Absorption Spectroscopy (XAS) measurements. After qualifying the ionization chambers, the detectors were used in the dispersive EXAFS beamline (BL-08) at INDUS-2 SRS in Turbo-XAS geometry. Using the same setup and under the same setting, XAS spectra were also recorded with a CCD detector and the observation on relative performance of the ionization chamber vis-a-vis the CCD detector is presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Present status of sensitive detector of reactor’s antineutrinos using scintillating detectors

In 2011, the reanalysis of the reactor antineutrinos spectra led to the formulation of the Reactor Antineutrino Anomaly (RAA) [1], which indicates the discrepancy between measured and expected antineutrino fluxes on short baselines. This discrepancy appears to favor the existence of the fourth “sterile” neutrino with |Δm{sup 2}|>1 eV{sup 2}. To confirm or reject this hypothesis a high sensitive antineutrino detector located close to the reactor is required. In addition to that such a detector could be used to online monitor the isotopic composition of the reactor core and to prevent illegal production and removal of{sup 239}Pu, which is the essential part of nuclear weapons. Detector DANSSino [2] already proved that even a compact antineutrino detector (∼ 1 m{sup 3}) based on polystyrene is capable of antineutrino detection in the close vicinity of a reactor core (∼ 10 m) with signal to background ratio about one. As a common activity between JINR Dubna and IEAP CTU a new prototype of detector (called S{sup 3}) has been proposed and is under construction. The construction design, selected results of Monte Carlo simulations and results of benchmark tests are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recovery of coincident frequency domain multiplexed detector pulses using sequential deconvolution

Multiplexing of radiation detector signals into a single channel significantly reduces the need for a large number of digitizer channels, which reduces the cost and the power consumption of a data acquisition system. We previously demonstrated frequency domain multiplexing by convolution using a prototype system that multiplexed two EJ-309 organic scintillators signals into a single channel. Each detector pulse was converted to a damped sinusoid which was then combined into a single channel. The combined signal was digitized and the original detector signal was recovered from the damped sinusoid by deconvolution. In this paper, we demonstrate the recovery of multiple detector signals that arrive during the same digitized record via a new sequential deconvolution method. Here, when two detectors produce signals in the same digitized record and their pulses do not overlap in time, we found that the charge, arrival time, and particle type can be estimated fairly precisely for the first pulse, but the second pulse exhibits substantial degradation in the precision of the estimated charge and arrival time. When the pulses overlap in time, we demonstrate both theoretically and experimentally that the part of the first pulse that does not overlap with the second can be recovered accurately, so the arrival time and amplitude of the first pulse can be estimated fairly precisely, but not the charge or particle type. None of these quantities can be estimated precisely for the second pulse when the two pulses overlap.

47 OTHER INSTRUMENTATION↗

Setting the threshold for high throughput detectors: A mathematical approach for ensembles of dynamic, heterogeneous, probabilistic anomaly detectors

Cyber operations now manage a high volume of heterogeneous log data. Anomaly Detection (AD) in such operations involves multiple (e.g., per IP, per data type) ensembles of detectors modeling heterogeneous characteristics (e.g., rate, size, type) often with adaptive online models producing alerts in near real time. Because of the high data volume, setting the threshold for each detector in such a system is an essential yet underdeveloped configuration issue that, if slightly mistuned, can leave the system useless, either producing a myriad of alerts (and flooding downstream systems) or giving none. In this work, we build on the foundations of Ferragut et al. to provide a set of rigorous results for understanding the relationship between threshold values and alert quantities for probabilistic detectors. This informs an algorithm for setting the threshold of multiple, heterogeneous, possibly dynamic detectors completely a priori, in principle. Indeed, if the underlying distribution of the incoming data is known, the algorithm provides provably manageable thresholds. If the distribution is unknown (poorly estimated), our analysis gives insight into how the model distribution differs from the actual distribution, indicating refitting is necessary. We provide empirical experiments, regulating the alert rate of a system with ≈2,500 adaptive detectors scoring over 1.5M events in 5 hours of timestamps. Further, we demonstrate on real network data and detection framework of Harshaw et al. the alternative case, demonstrating that the inability to regulate alerts indicates how the detection model is not a good fit to the data.

Bridges, Robert↗

Novel Light Detectors for Directional MeV scale DM Detectors

The search for sub-GeV dark matter requires novel detector development due to the small expected ionization signal and large backgrounds, many of which still need to be well-modeled. For this reason, to unambiguously detect dark matter, a detector must be able to determine the directionality of the incoming particles so that the daily modulation of the rate can be used to confirm a dark matter signal. This can be accomplished by combining anisotropic scintillating crystals, such as trans-Stilbene, as a detector target, with an optically-sensitive Skipper CCD as a readout. I will present on my work over the past six months developing the first prototype of this detector, including optical testing of the trans-Stilbene and design of the detector. This work will lead to characterization of the CCDs and deployment of the first prototype later this year.

Hoch, Nora [MIT]↗

Non-streaming high-efficiency perforated semiconductor neutron detectors, methods of making same and measuring wand and detector modules utilizing same

Non-streaming high-efficiency perforated semiconductor neutron detectors, method of making same and measuring wands and detector modules utilizing same are disclosed. The detectors have improved mechanical structure, flattened angular detector responses, and reduced leakage current. A plurality of such detectors can be assembled into imaging arrays, and can be used for neutron radiography, remote neutron sensing, cold neutron imaging, SNM monitoring, and various other applications.

McGregor, Douglas S↗

Fabrication of Detector Arrays for the SPT-3G Receiver

The South Pole Telescope third-generation (SPT-3G) receiver was installed during the austral summer of 2016–2017. It is designed to measure the cosmic microwave background across three frequency bands centered at 95, 150, and 220 GHz. The SPT-3G receiver has ten focal plane modules, each with 269 pixels. Each pixel features a broadband sinuous antenna coupled to a niobium microstrip transmission line. In-line filters define the desired band-passes before the signal is coupled to six bolometers with Ti/Au/Ti/Au transition edge sensors (three bands × two polarizations). In total, the SPT-3G receiver is composed of 16,000 detectors, which are read out using a 68 × frequency-domain multiplexing scheme. In this paper, we present the process employed in fabricating the detector arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Gamma-ray Burst Detector Based on the Silicon Drift Detector Array and Scintillators

We propose a gamma-ray burst (GRB) detector combining the silicon drift detector (SDD) array and scintillators with broadband X-ray and gamma-ray coverage (0.5-1000 keV or more), high energy resolution (2-10%) and high time resolution ({approx}{mu}s) in space. To realize such compact high-performance detector without photomultiplier tubes, we constructed proto-type model using KETEK SDD with a detection area of 1 cm{sup 2} and BGO crystal. The detector shows a very good performance. Obtained FWHM energy resolution was 191 eV at 5.9 keV in the SDD, while 6.5 % at 662 keV in the BGO at -30 deg. C. Evaluation of the 7 channel SDD array and development of analog ASIC for its readout are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗