Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Measurement of total and differential W + W - production cross sections in proton-proton collisions at √s=8 TeV with the ATLAS detector and limits on anomalous triple-gauge-boson couplings

The production of W boson pairs in proton-proton collisions at √s=8 TeV is studied using data corresponding to 20.3 fb -1 of integrated luminosity collected by the ATLAS detector during 2012 at the CERN Large Hadron Collider. The W bosons are reconstructed using their leptonic decays into electrons or muons and neutrinos. Events with reconstructed jets are not included in the candidate event sample. A total of 6636 WW candidate events are observed. Measurements are performed in fiducial regions closely approximating the detector acceptance. The integrated measurement is corrected for all acceptance effects and for the W branching fractions to leptons in order to obtain the total WW production cross section, which is found to be 71.1 ± 1.1(stat) -5.0+5.7(syst)±1.4(lumi) pb. This agrees with the next-to-next-to-leading-order Standard Model prediction of 63.2-1.4+1.6(scale)±1.2(PDF) pb. Fiducial differential cross sections are measured as a function of each of six kinematic variables. The distribution of the transverse momentum of the leading lepton is used to set limits on anomalous triple-gauge-boson couplings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GEANT4 models of HPGe detectors for radioassay

Radiation transport models of two high purity germanium detectors, GeII and GeIII, located at the University of Alabama have been created in GEANT4 (Agostinelli et al., 2003) [1].These detectors have been used extensively for radioassay measurements of materials used in various low background experiments. The two models have been validated against actual data under several scenarios typically seen in radioassay measurements. Furthermore, the systematic uncertainties of the models for GeII and GeIII are estimated to be ~12% and ~9% respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector requirements and simulation results for the EIC exclusive, diffractive and tagging physics program using the ECCE detector concept

This article presents a collection of simulation studies using the ECCE detector concept in the context of the EIC’s exclusive, diffractive, and tagging physics program, which aims to further explore the rich quark–gluon structure of nucleons and nuclei. To successfully execute the program, ECCE proposed to utilize the detector system close to the beamline to ensure exclusivity and tag ion beam/fragments for a particular reaction of interest. Preliminary studies confirm the proposed technology and design satisfy the requirements. Further, the projected physics impact results are based on the projected detector performance from the simulation at 10 or 100 fb -1 of integrated luminosity. Additionally, insights related to a potential second EIC detector are documented, which could serve as a guidepost for future development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced silicon tracking detector developments for the future Electron-Ion Collider

The proposed Electron-Ion Collider (EIC) will operate high-luminosity high-energy electron+proton and electron+nucleus collisions at the collision energies from 20 GeV to 141 GeV to solve several fundamental questions in the high energy and nuclear physics fields. Its instantaneous luminosity can reach 10 33-34 cm -2 s -1 and the bunching crossing rate is around 10 ns. The EIC project has received CD1 approval from the US DOE in 2021 and moves toward the machine design and preparation for construction. To realize various particle measurements with high precision at the future EIC, a low material-budget and high-granularity silicon vertex and tracking detector with fine spatial and momentum resolutions and nearly 4π solid angle coverage is desired. The Monolithic Active Pixel Sensor (MAPS) and AC Coupled Low Gain Avalanche Diode (AC-LGAD) technologies stand out of several advanced technology options for the EIC silicon vertex and tracking detector subsystems. The MAPS technology has advanced features of low material budget, low power consumption, good radiation resistance and fine spatial resolution. The AC-LGAD technology can achieve fast timing resolution. Latest studies and progress of the EIC silicon vertex and tracking detector conceptual design, performance validations in simulation and ongoing MAPS and AC-LGAD R&D will be shown. Furthermore, schedule and plan of the EIC project detector development will be discussed as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Godiva IV central cavity neutron environment characterization with threshold neutron detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high-purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

Whitman, Nicholas H.↗

Performance of ePix10K, a high dynamic range, gain auto-ranging pixel detector for FELs

ePix10K is a hybrid pixel detector developed at SLAC for demanding free-electron laser (FEL) applications, providing an ultrahigh dynamic range (245 eV to 88 MeV) through gain auto-ranging. It has three gain modes (high, medium and low) and two auto-ranging modes (high-to-low and medium-to-low). The first ePix10K cameras are built around modules consisting of a sensor flip-chip bonded to 4 ASICs, resulting in 352 × 384 pixels of 100 µm x 100 µm each. We present results from extensive testing of three ePix10K cameras with FEL beams at LCLS, resulting in a measured noise floor of 245 eV rms, or 67 e - equivalent noise charge (ENC), and a range of 11 000 photons at 8 keV. We demonstrate the linearity of the response in various gain combinations: fixed high, fixed medium, fixed low, auto-ranging high to low, and auto-ranging medium-to-low, while maintaining a low noise (well within the counting statistics), a very low cross-talk, perfect saturation response at fluxes up to 900 times the maximum range, and acquisition rates of up to 480 Hz. Finally, we present examples of high dynamic range x-ray imaging spanning more than 4 orders of magnitude dynamic range (from a single photon to 11 000 photons/pixel/pulse at 8 keV). Achieving this high performance with only one auto-ranging switch leads to relatively simple calibration and reconstruction procedures. The low noise levels allow usage with long integration times at non-FEL sources. ePix10K cameras leverage the advantages of hybrid pixel detectors with high production yield and good availability, minimize development complexity through sharing the hardware, software and DAQ development with all other versions of ePix cameras, while providing an upgrade path to 5 kHz, 25 kHz and 100 kHz in three steps over the next few years, matching the LCLS-II requirements.

47 OTHER INSTRUMENTATION↗

Germanium Detectors in Homeland Security at PNNL

Neutron and gamma-ray detection is used for non-proliferation and national security applications. While lower energy resolution detectors such as NaI(Tl) have their place, high purity germanium (HPGe) also has a role to play. A detection with HPGe is often a characterization due to the very high energy resolution. However, HPGe crystals remain small and expensive leaving arrays of smaller crystals as an excellent solution. PNNL has developed two similar HPGe arrays for two very different applications. One array, the Multisensor Aerial Radiation Survey (MARS) detector is a fieldable array that has been tested on trucks, boats, and helicopters. The CASCADES HPGe array is an array designed to assay samples in a low background environment. The history of HPGe arrays at PNNL and the development of MARS and CASCADES will be detailed in this paper along with some of the other applications of HPGe at PNNL.

arrays↗

Modelling radiation damage to pixel sensors in the ATLAS detector

Silicon pixel detectors are at the core of the current and planned upgrade of the ATLAS experiment at the LHC. Given their close proximity to the interaction point, these detectors will be exposed to an unprecedented amount of radiation over their lifetime. The current pixel detector will receive damage from non-ionizing radiation in excess of 10 15 1 MeV n eq /cm 2 , while the pixel detector designed for the high-luminosity LHC must cope with an order of magnitude larger fluence. We present a digitization model incorporating effects of radiation damage to the pixel sensors. The model is described in detail and predictions for the charge collection efficiency and Lorentz angle are compared with collision data collected between 2015 and 2017 (≤ 10 15 1 MeV n eq /cm 2 ).

43 PARTICLE ACCELERATORS↗

Analysis techniques for the evaluation of the neutrinoless double- β decay lifetime in Te 130 with the CUORE-0 detector

We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta ( 0 ν β β ) decay in 130 Te and the associated limit on the effective Majorana mass of the neutrino using the CUORE-0 detector. CUORE-0 is a bolometric detector array located at the Laboratori Nazionali del Gran Sasso that was designed to validate the background reduction techniques developed for CUORE, a next-generation experiment scheduled to come online in 2016. CUORE-0 is also a competitive 0 ν β β decay search in its own right and functions as a platform to further develop the analysis tools and procedures to be used in CUORE. These include data collection, event selection and processing, as well as an evaluation of signal efficiency. In particular, we describe the amplitude evaluation, thermal gain stabilization, energy calibration methods, and the analysis event selection used to create our final 0 ν β β search spectrum. We define our high level analysis procedures, with emphasis on the new insights gained and challenges encountered. We outline in detail our fitting methods near the hypothesized 0 ν β β decay peak and catalog the main sources of systematic uncertainty. Finally, we derive the 0 ν β β decay half-life limits previously reported for CUORE-0, T 0 ν 1 / 2 > 2.7 × 10 24 yr , and in combination with the Cuoricino limit, T 0 ν 1 / 2 > 4.0 × 10 24 yr .

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurements of normalized differential cross sections for t t ¯ production in p p collisions at ( s ) = 7 TeV using the ATLAS detector

We present measurements of normalized differential cross sections for top-quark pair production as a function of the top-quark transverse momentum, and of the mass, transverse momentum, and rapidity of the $t\bar{t}$ system, in proton–proton collisions at a center-of-mass energy of √ s=7 TeV. The data set corresponds to an integrated luminosity of 4.6 fb ₋1 , recorded in 2011 with the ATLAS detector at the CERN Large Hadron Collider. Events are selected in the lepton + jets channel, requiring exactly one lepton and at least four jets with at least one of the jets tagged as originating from a b-quark. The measured spectra are corrected for detector efficiency and resolution effects and are compared to several Monte Carlo simulations and theory calculations. The results are in fair agreement with the predictions in a wide kinematic range. Nevertheless, data distributions are softer than predicted for higher values of the mass of the $t\bar{t}$ system and of the top-quark transverse momentum. Lastly, the measurements can also discriminate among different sets of parton distribution functions.

43 PARTICLE ACCELERATORS↗

Electron and photon energy calibration with the ATLAS detector using LHC Run 1 data

This paper presents the electron and photon energy calibration achieved with the ATLAS detector using about 25 fb -1 of LHC proton–proton collision data taken at centre-of-mass energies of √s=7 and 8 TeV. The reconstruction of electron and photon energies is optimised using multivariate algorithms. The response of the calorimeter layers is equalised in data and simulation, and the longitudinal profile of the electromagnetic showers is exploited to estimate the passive material in front of the calorimeter and reoptimise the detector simulation. After all corrections, the Z resonance is used to set the absolute energy scale. For electrons from Z decays, the achieved calibration is typically accurate to 0.05 % in most of the detector acceptance, rising to 0.2 % in regions with large amounts of passive material. The remaining inaccuracy is less than 0.2–1 % for electrons with a transverse energy of 10 GeV, and is on average 0.3 % for photons. The detector resolution is determined with a relative inaccuracy of less than 10 % for electrons and photons up to 60 GeV transverse energy, rising to 40 % for transverse energies above 500 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the transverse momentum and Φ$*\atop{η}$ distributions of Drell–Yan lepton pairs in proton–proton collisions at √s=8 TeV with the ATLAS detector

Distributions of transverse momentum p$ℓℓ\atop{T}$ and the related angular variable Φ$*\atop{η}$ of DrellΓÇôYan lepton pairs are measured in 20.3$\perp$áfb -1 of protonΓÇôproton collisions at √s=8$\perp$áTeV with the ATLAS detector at the LHC. Measurements in electron-pair and muon-pair final states are corrected for detector effects and combined. Compared to previous measurements in protonΓÇôproton collisions at √s=7$\perp$áTeV, these new measurements benefit from a larger data sample and improved control of systematic uncertainties. Measurements are performed in bins of lepton-pair mass above, around and below the Z-boson mass peak. The data are compared to predictions from perturbative and resummed QCD calculations. For values of Φ$*\atop{η}$<1 the predictions from the Monte Carlo generator ResBos are generally consistent with the data within the theoretical uncertainties. However, at larger values of Φ$*\atop{η}$ this is not the case. Monte Carlo generators based on the parton-shower approach are unable to describe the data over the full range of pℓℓTpTℓℓ while the fixed-order prediction of Dynnlo falls below the data at high values of p$ℓℓ\atop{T}$ . ResBos and the parton-shower Monte Carlo generators provide a much better description of the evolution of the Φ$*\atop{η}$ and p$ℓℓ\atop{T}$ distributions as a function of lepton-pair mass and rapidity than the basic shape of the data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Intelligent Experiments Through Real-time AI: Fast Data Processing and Autonomous Detector Control for sPHENIX and Future EIC Detectors (Final Report)

The overall vision of this project was to integrate real-time artificial intelligence (AI) directly into the data acquisition and detector-control systems of nuclear physics experiments, including both fast online event selection and an autonomous detector-control feedback loop. The work carried out under the award focused on the fast online event-selection half of that vision: the efficient recording of low-momentum heavy-flavor (HF) hadron decays in proton-proton collisions at the sPHENIX experiment at the Relativistic Heavy Ion Collider (RHIC)—an observable that requires fast tracking and topological trigger selection not previously demonstrated at RHIC, and that is essential for QCD studies at future facilities such as the Electron-Ion Collider (EIC). The autonomous detector-control (GPU-based feedback) component named in the project title remained a design concept and was not implemented under this award. The Massachusetts Institute of Technology (MIT) group led the offline simulation and data processing needed to train the machine-learning (ML) models, the translation of trained models to Field-Programmable Gate Array (FPGA) firmware using the hls4ml framework, and the physics validation of heavy-flavor reconstruction. Over the award period, the team developed and hardware-tested the principal components of an AI-based heavy-flavor trigger on simulated and recorded sPHENIX tracker data: a software Bipartite Graph Attention Network (BiGAT) trigger model reaching > 95% signal efficiency at 99% background rejection; an FPGA-native hit clusterizer matching the offline clustering; smaller networks synthesized to FPGA within the required sub-10 µs latency; and an assembled decoder–clusterizer–inference firmware chain exercised on the FELIX readout board. A complete, fully integrated hardware demonstrator was not finished within the award period. This report documents the project goals, the MIT group’s contributions, the technical accomplishments, and the outlook toward applications at the future EIC ePIC detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a Massive, Highly Multiplexible, Phonon-Mediated Particle Detector Using Kinetic Inductance Detectors

Here, we present a status update on the development of a phonon-mediated particle detector using kinetic inductance detector (KID). The design is intended for \(\mathscr {O}(1)\) kg substrate, using \(\mathscr {O}(10^{2})\) KIDs on a single readout line, to image the athermal phonon distribution at < 1 mm position resolution and \(\mathscr {O}(10)\) eV energy resolution. The design specification is set by the need to improve position reconstruction fidelity while maintaining low energy threshold for future rare-event searches such as for low-mass dark matter. Furthermore, we report on the design, which shows negligible crosstalk and > 95% inductor current uniformity, using the coplanar waveguide feedline, ground shield, and a new class of KIDs with symmetric coplanar stripline (sCPS) inductor. The multiplexing is designed upon the frequency-geometry relation we develop for the sCPS KIDs. We introduce the fabrications of the Nb RF assessment prototypes and the high phonon collection efficiency Al–Nb devices. We achieve \(\lesssim \) 0.07% frequency displacement on a 80-KID RF assessment prototype, and the result indicates that we may place more than 180 resonances in our 0.4 GHz readout band with minimal frequency misordering. The coupling quality factors are \(\sim \) 10 \(^{5}\) as designed. Finally, we update our work in progress in fabricating the \(\mathscr {O}(10^{2})\) KID, bi-material, \(\mathscr {O}(1)\) kg detectors, and the expected position and energy resolutions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance in beam tests of irradiated Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector

The High Granularity Timing Detector (HGTD) will be installed in the ATLAS detector to mitigate pile-up effects during the High Luminosity (HL) upgrade of the Large Hadron Collider (LHC) at CERN. The design of the HGTD is based on the use of Low Gain Avalanche Detectors (LGADs), with an active thickness of 50 μm, that allow to measure with high-precision the time of arrival of particles. The HGTD will improve the particle-vertex assignment by measuring the track time with a resolution ranging from approximately 30 ps at the beginning of the HL-LHC operations to 50 ps at the end. Performances of several unirradiated, as well as neutron- and proton-irradiated, LGAD sensors from different vendors have been measured in beam test campaigns during the years 2018 and 2019 at CERN SPS and DESY. This paper presents the results obtained with data recorded by an oscilloscope synchronized with a beam telescope which provides particle position information within a resolution of a few μm. Collected charge, time resolution and hit efficiency are presented. In addition to these properties, the charge uniformity is also studied as a function of the position of the incident particle inside the sensor pad.

47 OTHER INSTRUMENTATION↗