Application of NCRP 156 Wound Models for the Analysis of Bioassay Data from Plutonium Contaminated Wound Cases

The NCRP 156 wound model was heavily based on data from animal experiments. The authors of the report acknowledged this limitation and encouraged validation of the models using data from human wound exposures. The objective of this paper was to apply the NCRP 156 wound models to the bioassay data from four plutonium-contaminated wound cases reported in the literature. Because a wide variety of forms of plutonium can be expected at a nuclear facility, a combination of the wound models—rather than a single model—was used to successfully explain both the urinary excretion data and wound retention data in three cases. The data for the fourth case could not be explained by any combination of the default wound models. While this may possibly be attributed to the existence of a category of plutonium whose solubility and chemistry are different than those described by the NCRP 156 default categories, the differences may also be the result of differences in systemic biokinetics. Lastly, the concept of using a combination of biokinetic models may be extended to inhalation exposures as well, where more than one form of radionuclide—particles of different solubility or different sizes—may exist in a workplace.

60 APPLIED LIFE SCIENCES↗

Cross-section measurement and analysis for the {sup 149}Sm(n,alpha){sup 146}Nd reaction at 6.0 MeV

We have measured the {sup 149}Sm(n,alpha){sup 146}Nd cross section at 6.0 MeV to be 0.12+-0.018 mb. This is the first reported result for this cross section in the MeV region and so should be helpful for constraining nuclear data evaluations (which differ by a factor of 40 for this reaction at this energy) and for testing and improving nuclear models. The experiment was performed at the at the 4.5-MV Van de Graaff accelerator of Peking University. Neutrons were produced via the {sup 2}H(d,n){sup 3}He reaction using a deuterium gas target, and absolute neutron flux was determined with a small {sup 238}U fission chamber. Alpha particles were detected using a two-section gridded ionization chamber in which two large-area {sup 149}Sm{sub 2}O{sub 3} samples were placed back-to-back so that the cross section and forward/backward ratio were measured for nearly the entire 4pi solid angle. The data were compared to statistical-model predictions using the code talys. Good agreement between the measured and theoretical cross sections could be obtained with a small modification of the alpha-optical potential parameters from their default values in talys. However, we were not able to reproduce the measured forward/backward ratio. In addition, using the previously reported {sup 147}Sm(n,alpha){sup 144}Nd cross section at 6.0 MeV together with our new result, good agreement was found between the measured and predicted cross-section ratio for these two isotopes. Finally, none of the existing evaluated data libraries are in agreement with our new data to within the experimental uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimizing Process-to-Core Mappings for Application Level Multi-dimensional MPI Communications

Multi-dimensional MPI communications, where MPI communications have to be performed in each dimension of a Cartesian communicator, have been frequently used in many of today's high performance computing applications. While individual MPI collective communications for regular communicators with a one-dimensional linear-ranking of processes have been extensively studied and optimized, little optimizations have been performed for multi-dimensional MPI collective communications on multi-dimensional Cartesian topology. In this paper, we optimize multi-dimensional MPI collective communications for SMP and multi-core systems at the application level. We show that the default Cartesian topology built by the state-of-the-art MPI implementations produce sub-optimal performance for multi-dimensional MPI collective communications. We design optimal process-to-core mapping schemes for Cartesian communicators to minimize the total inter-node communications. The proposed technique improves the performance by up to 80% over the default Cartesian topology built by Cray's MPI implementation MPT 3.1.02 on the world's current second fastest supercomputer Jaguar at Oak Ridge National Laboratory.

Computer Science↗

Performance Evaluation of Adaptive Routing on Dragonfly-based Production Systems

Performance of applications in production environments can he sensitive to network congestion. Cray Aries supports adaptively routing each network packet independently based on the load or congestion encountered as a packet traverses the network. Software can dictate different routing policies, adjusting between minimal and non-minimal bias, for each posted message. We have extensively evaluated the sensitivity of the routing bias selection on application performance as well as whole system performance in both production and controlled conditions. We show that the default routing bias used in Aries-based systems is often sub-optimal and that using a higher bias towards minimal routes will not only reduce the congestion effects on the application but also will decrease the overall congestion on the network. This routing scheme results in not only improved mean performance (by up to 12%) of most production applications hut also reduced run-to-run variability. Our study prompted the two supercomputing facilities (ALCF and NERSC) to change the default routing mode on their Aries-based systems. We present the substantial improvement measured in the overall congestion management and interconnect performance in production after making this change.

Chunduri, Sudheer↗

Derivation of WECC Distributed PV System Model Parameters from Quasi-Static Time-Series Distribution System Simulations

The response of low voltage networks with high penetration of PV systems to transmission network faults will, in the future, determine the overall power system performance during certain hours of the year. The WECC distributed PV system model (PVD1) is designed to represent small-scale distribution-connected systems. Although default values are provided by WECC for the model parameters, tuning of those parameters seems to become important in order to accurately estimate the partial loss of distributed PV systems for bulk system studies. The objective of this paper is to describe a new methodology to determine the WECC distributed PV system (PVD1) model parameters and to derive parameter sets obtained for six distribution circuits of a Californian investor-owned utility with large amounts of distributed PV systems. The results indicate that the parameters for the partial loss of distributed PV systems may differ significantly from the default values provided by WECC.

14 SOLAR ENERGY↗

Multi-modelling predictions show high uncertainty of required carbon input changes to reach a 4‰ target

Soils store vast amounts of carbon (C) on land, and increasing soil organic carbon (SOC) stocks in already managed soils such as croplands may be one way to remove C from the atmosphere, thereby limiting subsequent warming. The main objective of this study was to estimate the amount of additional C input needed to annually increase SOC stocks by 4‰ at 16 long-term agricultural experiments in Europe, including exogenous organic matter (EOM) additions. We used an ensemble of six SOC models and ran them under two configurations: (1) with default parametrization and (2) with parameters calibrated site-by-site to fit the evolution of SOC stocks in the control treatments (without EOM). We compared model simulations and analysed the factors generating variability across models. The calibrated ensemble was able to reproduce the SOC stock evolution in the unfertilised control treatments. We found that, on average, the experimental sites needed an additional 1.5 ± 1.2 Mg C ha -1 year -1 to increase SOC stocks by 4‰ per year over 30 years, compared to the C input in the control treatments (multi-model median ± median standard deviation across sites). That is, a 119% increase compared to the control. While mean annual temperature, initial SOC stocks and initial C input had a significant effect on the variability of the predicted C input in the default configuration (i.e., the relative standard deviation of the predicted C input from the mean), only water-related variables (i.e., mean annual precipitation and potential evapotranspiration) explained the divergence between models when calibrated. Here, our work highlights the challenge of increasing SOC stocks in agriculture and accentuates the need to increasingly lean on multi-model ensembles when predicting SOC stock trends and related processes. To increase the reliability of SOC models under future climate change, we suggest model developers to better constrain the effect of water-related variables on SOC decomposition.

4 per 1000 initiative↗

Measurement of relative output factors for the 8 and 4 mm collimators of Leksell Gamma Knife Perfexion by film dosimetry

Three types of films, Kodak EDR2, Gafchromic EBT, and Gafchromic MD-V2-55, were used to measure relative output factors of 4 and 8 mm collimators of the Leksell Gamma Knife Perfexion. The optical density to dose calibration curve for each of the film types was obtained by exposing the films to a range of known doses. Ten data points were acquired for each of the calibration curves in the dose ranges from 0 to 4 Gy, 0 to 8 Gy, and 0 to 80 Gy for Kodak EDR2, Gafchromic EBT, and Gafchromic MD-V2-55 films, respectively. For the measurement of relative output factors, five films of each film type were exposed to a known dose. All films were scanned using EPSON EXPRESSION 10000 XL scanner with 200 dpi resolution in 16 bit gray scale for EDR2 film and 48 bit color scale for Gafchromic films. The scanned images were imported in the red channel for both Gafchromic films. The background corrections from an unexposed film were applied to all films. The output factors obtained from film measurements were in a close agreement both with the Monte Carlo calculated values of 0.924 and 0.805 for 8 and 4 mm collimators, respectively. These values are provided by the vendor and used as default values in the vendor's treatment planning system. The largest differences were noted for the Kodak EDR 2 films (-2.1% and -4.5% for 8 and 4 mm collimators, respectively). The best agreement observed was for EBT Gafchromic film (-0.8% and +0.6% differences for 8 and 4 mm collimators, respectively). Based on the present values, no changes in the default relative output factor values were made in the treatment planning system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom

Purpose : To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with{sup 125}I, {sup 103}Pd, or {sup 131}Cs seeds, and to investigate doses to ocular structures. Methods : An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom and our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Results : Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20–30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%–10% and 13%–14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%–17% and 29%–34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model simulation by up to 16%. In the full eye model simulations, the average dose to the lens is larger by 7%–9% than the dose to the center of the lens, and the maximum dose to the optic nerve is 17%–22% higher than the dose to the optic disk for all radionuclides. In general, when normalized to the same prescription dose at the tumor apex, doses delivered to all structures of interest in the full eye model are lowest for{sup 103}Pd and highest for {sup 131}Cs, except for the tumor where the average dose is highest for {sup 103}Pd and lowest for {sup 131}Cs. Conclusions : The eye is not radiologically water-equivalent, as doses from simulations of the plaque in the full eye model differ considerably from doses for the plaque in a water phantom and from simulated TG-43 calculated doses. This demonstrates the importance of model-based dose calculations for eye plaque brachytherapy, for which accurate elemental compositions of ocular media are necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-199: How Number of Control Points Influences the Dynamic IMRT Plan Quality and Deliverability

Purpose: To study the influence of number of control points on plan quality and deliverability. Methods: Five previously treated patients of carcinoma of rectum were selected. Planning target volume (PTV) and organs at risk (OARs) i.e. bladder and bowel were contoured. Dynamic IMRT plans (6MV, 7-fields, 45Gy/25 fractions and prescribed at 95% isodose) were created in Eclipse (Varian medical system, Palo Alto, CA) treatment planning system (TPS) for Varian CL2300C/D linear-accelerator. Base plan was calculated with 166 control points, variable mode (Eclipse Default). For generating other plans, all parameters were kept constant, only number of control points (Fixed mode) was varied as follows: 100, 166 and 200. Then, plan quality was analyzed in terms of maximum and mean dose received by the PTV and OARs. For plan deliverability, TPS calculated fluence was verified with I’matriXX (IBA Dosimetry, Germany) array and compared with TPS dose-plane using gamma index criteria of 3% dose difference and 3mm distance to agreement (DTA). Total number of monitor units (MU) required to deliver a plan was also noted. Results: The maximum variation for the PTV maximum with respect to eclipse default control point (166) was 0.28% (0.14Gy). Similarly, PTV mean varied only up to 0.22 %( 0.11Gy). Bladder maximum and bladder mean varied up to 0.51% (0.24Gy) and 0.16% (0.06Gy). The variation for the bowel maximum and bowel mean was also only 0.39% (0.19Gy) and 0.33% (0.04Gy). Total MU was within 0.32 % (4MU). Average gamma pass rate using different control points for five patients are 98.75±0.33%, 99.37±0.09%, 99.29±0.12%, 98.14±0.13% and 99.25±0.14% respectively. Conclusion: Slight variation (<1%) in PTV and OARs maximum and mean doses was observed with varying number of control points. Monitor unit was also not varied much. Reducing number of control points did not showed any comprise in plan deliverability in terms of gamma index pass rate.

60 APPLIED LIFE SCIENCES↗

SU-E-T-631: Commissioning and Comprehensive Evaluation of the ArcCHECK Cylindrical Diode Array for VMAT QA

Purpose: Commissioning and comprehensive evaluation of ArcCHECK phantom for dosimetry of VMAT QA, using 6MV photon beam with and without the flattening filter. Methods: ArcCHECK was evaluated for response dependency on linac dose rate, instantaneous dose rate, radiation field size, beam angle and couch insertion. Scatter dose characterization, consistency and symmetry of response, dosimetric accuracy of fixed aperture arcs and clinical VMAT plans were investigated. Measurements were done using TrueBeam™ STx accelerator (Console version 1.6) with a 6 MV beam with and without flattening filter. Reference dose-grids were calculated using Eclipse TPS Analytical Anisotropic Algorithm (AAA version 10.0.39). Planned doses were calculated using symmetric 2mm 3D dose grids with 4 degree angular resolution defaulted to each control point. Gamma evaluations were performed in absolute dose mode, with default normalization to maximum dose in the curved plane and a low dose threshold of 10% to restrict the analysis to clinically relevant areas. Global and local gamma indices at 3mm/3% and 2mm/2% level were computed using SNC software (version 6.0). Results: Results of gamma analysis demonstrated an overall agreement between ArcCHECK measured and TPS calculated reference doses. Field size dependency was within 0.5% of the reference. Dose-rate based dependency was well within 1% of the TPS reference and the angular dependency was ±3% of the reference, as tested for BEV angles. At the level of 3%/3mm, narrow and wide open arcs as well as clinical VMAT cases demonstrated high level of dosimetry accuracy in global gamma passing rates for both 6X and 6F beams. At the level of 2%/2mm two VMAT cases involving the narrow heavily modulated arcs demonstrated lower passing rates. Conclusion: ArcCHECK phantom with latest software and hardware upgrades is suitable for VMAT QA. For higher sensitivity of 2%/2mm gamma analysis, we intend to use it as one of the VMAT QA evaluation metrics.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-47: Comparison of Online Image Registrations of Varian TrueBeam Cone-Beam CT and BrainLab ExacTrac Imaging Systems

Purpose To compare online image registrations of TrueBeam cone-beam CT (CBCT) and BrainLab ExacTrac imaging systems. Methods Tests were performed on a Varian TrueBeam STx linear accelerator (Version 2.0), which is integrated with a BrainLab ExacTrac imaging system (Version 6.0.5). The study was focused on comparing the online image registrations for translational shifts. A Rando head phantom was placed on treatment couch and immobilized with a BrainLab mask. The phantom was shifted by moving the couch translationally for 8 mm with a step size of 1 mm, in vertical, longitudinal, and lateral directions, respectively. At each location, the phantom was imaged with CBCT and ExacTrac x-ray. CBCT images were registered with TrueBeam and ExacTrac online registration algorithms, respectively. And ExacTrac x-ray image registrations were performed. Shifts calculated from different registrations were compared with nominal couch shifts. Results The averages and ranges of absolute differences between couch shifts and calculated phantom shifts obtained from ExacTrac x-ray registration, ExacTrac CBCT registration with default window, ExaxTrac CBCT registration with adjusted window (bone), Truebeam CBCT registration with bone window, and Truebeam CBCT registration with soft tissue window, were: 0.07 (0.02–0.14), 0.14 (0.01–0.35), 0.12 (0.02–0.28), 0.09 (0–0.20), and 0.06 (0–0.10) mm, in vertical direction; 0.06 (0.01–0.12), 0.27 (0.07–0.57), 0.23 (0.02–0.48), 0.04 (0–0.10), and 0.08 (0– 0.20) mm, in longitudinal direction; 0.05 (0.01–0.21), 0.35 (0.14–0.80), 0.25 (0.01–0.56), 0.19 (0–0.40), and 0.20 (0–0.40) mm, in lateral direction. Conclusion The shifts calculated from ExacTrac x-ray and TrueBeam CBCT registrations were close to each other (the differences between were less than 0.40 mm in any direction), and had better agreements with couch shifts than those from ExacTrac CBCT registrations. There were no significant differences between TrueBeam CBCT registrations using different windows. In ExacTrac CBCT registrations, using bone window led to better agreements than using default window.

60 APPLIED LIFE SCIENCES↗

SU-F-207-02: Use of Postmortem Subjects for Subjective Image Quality Assessment in Abdominal CT Protocols with Iterative Reconstruction

Purpose: New radiation dose reduction technologies are emerging constantly in the medical imaging field. The latest of these technologies, iterative reconstruction (IR) in CT, presents the ability to reduce dose significantly and hence provides great opportunity for CT protocol optimization. However, without effective analysis of image quality, the reduction in radiation exposure becomes irrelevant. This work explores the use of postmortem subjects as an image quality assessment medium for protocol optimizations in abdominal CT. Methods: Three female postmortem subjects were scanned using the Abdomen-Pelvis (AP) protocol at reduced minimum tube current and target noise index (SD) settings of 12.5, 17.5, 20.0, and 25.0. Images were reconstructed using two strengths of iterative reconstruction. Radiologists and radiology residents from several subspecialties were asked to evaluate 8 AP image sets including the current facility default scan protocol and 7 scans with the parameters varied as listed above. Images were viewed in the soft tissue window and scored on a 3-point scale as acceptable, borderline acceptable, and unacceptable for diagnosis. The facility default AP scan was identified to the reviewer while the 7 remaining AP scans were randomized and de-identified of acquisition and reconstruction details. The observers were also asked to comment on the subjective image quality criteria they used for scoring images. This included visibility of specific anatomical structures and tissue textures. Results: Radiologists scored images as acceptable or borderline acceptable for target noise index settings of up to 20. Due to the postmortem subjects’ close representation of living human anatomy, readers were able to evaluate images as they would those of actual patients. Conclusion: Postmortem subjects have already been proven useful for direct CT organ dose measurements. This work illustrates the validity of their use for the crucial evaluation of image quality during CT protocol optimization, especially when investigating the effects of new technologies.

60 APPLIED LIFE SCIENCES↗

The impact of system matrix dimension on small FOV SPECT reconstruction with truncated projections

Purpose: A dedicated cardiac hybrid single photon emission computed tomography (SPECT)/CT scanner that uses cadmium zinc telluride detectors and multiple pinhole collimators for stationary acquisition offers many advantages. However, the impact of the reconstruction system matrix (SM) dimension on the reconstructed image quality from truncated projections and 19 angular samples acquired on this scanner has not been extensively investigated. In this study, the authors aimed to investigate the impact of the dimensions of SM and the use of body contour derived from adjunctive CT imaging as an object support in reconstruction on this scanner, in relation to background extracardiac activity. Methods: The authors first simulated a generic SPECT/CT system to image four NCAT phantoms with various levels of extracardiac activity and compared the reconstructions using SM in different dimensions and with/without body contour as a support for quantitative evaluations. The authors then compared the reconstructions of 18 patient studies, which were acquired on a GE Discovery NM570c scanner following injection of different radiotracers, including {sup 99m}Tc-Tetrofosmin and {sup 123}I-mIBG, comparing the scanner’s default SM that incompletely covers the body with a large SM that incorporates a patient specific full body contour. Results: The simulation studies showed that the reconstructions using a SM that only partially covers the body yielded artifacts on the edge of the field of view (FOV), overestimation of activity and increased nonuniformity in the blood pool for the phantoms with higher relative levels of extracardiac activity. However, the impact on the quantitative accuracy in the high activity region, such as the myocardium, was subtle. On the other hand, an excessively large SM that enclosed the entire body alleviated the artifacts and reduced overestimation in the blood pool, but yielded slight underestimation in myocardium and defect regions. The reconstruction using the larger SM with body contour yielded the most quantitatively accurate results in all the regions of interest for a range of uptake levels in the extracardiac regions. In patient studies, the SM incorporating patient specific body contour minimized extracardiac artifacts, yielded similar myocardial activity, lower blood pool activity, and subsequently improved myocardium-to-blood pool contrast (p < 0.0001) by an average of 7% (range 0%–18%) across all the patients, compared to the reconstructions using the scanner’s default SM. Conclusions: Their results demonstrate that using a large SM that incorporates a CT derived body contour in the reconstruction could improve quantitative accuracy within the FOV for clinical studies with high extracardiac activity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technical Note: Effect of explicit M and N-shell atomic transitions on a low-energy x-ray source

Purpose: In EGSnrc, atomic transitions to and from the M and N-shells are treated in an average way by default. This approach is justified in which the energy difference between explicit and average M and N-shell binding energies is less than 1 keV, and for most applications can be considered negligible. However, for simulations of low energy x-ray sources on thin, high-Z targets, characteristic x-rays can make up a significant portion of the source spectra. As of release V4-2.4.0, EGSnrc has included an option to enable a more complete algorithm of all atomic transitions available in the EADL compilation. In this paper, the effect of M and N-shell averaging on the calculation of half-value layer (HVL) and relative depth dose (RDD) curve of a 50 kVp intraoperative x-ray tube with a thin gold target was investigated. Methods: A 50 kVp miniature x-ray source with a gold target (The INTRABEAM System, Carl Zeiss, Germany) was modeled with the EGSnrc user code cavity, both with and without M and N-shell averaging. From photon fluence spectra simulations, the source HVLs were determined analytically. The same source model was then used with egs-chamber to calculate RDD curves in water. Results: A 4% increase of HVL was reported when accounting for explicit M and N-shell transitions, and up to a 9% decrease in local relative dose for normalization at 3 mm depth in water. Conclusions: The EGSnrc default of using averaged M and N-shell binding energies has an observable effect on the HVL and RDD of a low energy x-ray source with high-Z target. For accurate modeling of this class of devices, explicit atomic transitions should be included.

60 APPLIED LIFE SCIENCES↗

SU-D-BRB-02: Combining a Commercial Autoplanning Engine with Database Dose Predictions to Further Improve Plan Quality

Purpose: Database dose predictions and a commercial autoplanning engine both improve treatment plan quality in different but complimentary ways. The combination of these planning techniques is hypothesized to further improve plan quality. Methods: Four treatment plans were generated for each of 10 head and neck (HN) and 10 prostate cancer patients, including Plan-A: traditional IMRT optimization using clinically relevant default objectives; Plan-B: traditional IMRT optimization using database dose predictions; Plan-C: autoplanning using default objectives; and Plan-D: autoplanning using database dose predictions. One optimization was used for each planning method. Dose distributions were normalized to 95% of the planning target volume (prostate: 8000 cGy; HN: 7000 cGy). Objectives used in plan optimization and analysis were the larynx (25%, 50%, 90%), left and right parotid glands (50%, 85%), spinal cord (0%, 50%), rectum and bladder (0%, 20%, 50%, 80%), and left and right femoral heads (0%, 70%). Results: All objectives except larynx 25% and 50% resulted in statistically significant differences between plans (Friedman’s χ{sup 2} ≥ 11.2; p ≤ 0.011). Maximum dose to the rectum (Plans A-D: 8328, 8395, 8489, 8537 cGy) and bladder (Plans A-D: 8403, 8448, 8527, 8569 cGy) were significantly increased. All other significant differences reflected a decrease in dose. Plans B-D were significantly different from Plan-A for 3, 17, and 19 objectives, respectively. Plans C-D were also significantly different from Plan-B for 8 and 13 objectives, respectively. In one case (cord 50%), Plan-D provided significantly lower dose than plan C (p = 0.003). Conclusion: Combining database dose predictions with a commercial autoplanning engine resulted in significant plan quality differences for the greatest number of objectives. This translated to plan quality improvements in most cases, although special care may be needed for maximum dose constraints. Further evaluation is warranted in a larger cohort across HN, prostate, and other treatment sites. This work is supported by Philips Radiation Oncology Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-P-06: Moving From Computed Radiography to Digital Radiography: A Collaborative Approach to Improve Image Quality

Purpose: To bring together radiologists, technologists, and physicists to utilize post-processing techniques in digital radiography (DR) in order to optimize image acquisition and improve image quality. Methods: Sub-optimal images acquired on a new General Electric (GE) DR system were flagged for follow-up by radiologists and reviewed by technologists and medical physicists. Various exam types from adult musculoskeletal (n=35), adult chest (n=4), and pediatric (n=7) were chosen for review. 673 total images were reviewed. These images were processed using five customized algorithms provided by GE. An image score sheet was created allowing the radiologist to assign a numeric score to each of the processed images, this allowed for objective comparison to the original images. Each image was scored based on seven properties: 1) overall image look, 2) soft tissue contrast, 3) high contrast, 4) latitude, 5) tissue equalization, 6) edge enhancement, 7) visualization of structures. Additional space allowed for additional comments not captured in scoring categories. Radiologists scored the images from 1 – 10 with 1 being non-diagnostic quality and 10 being superior diagnostic quality. Scores for each custom algorithm for each image set were summed. The algorithm with the highest score for each image set was then set as the default processing. Results: Images placed into the PACS “QC folder” for image processing reasons decreased. Feedback from radiologists was, overall, that image quality for these studies had improved. All default processing for these image types was changed to the new algorithm. Conclusion: This work is an example of the collaboration between radiologists, technologists, and physicists at the University of New Mexico to add value to the radiology department. The significant amount of work required to prepare the processing algorithms, reprocessing and scoring of the images was eagerly taken on by all team members in order to produce better quality images and improve patient care.

60 APPLIED LIFE SCIENCES↗

SU-F-T-362: Quantification and Modelling of the Ionization Chamber Simulation Effective Points On Monaco Treatment Planning System

Purpose: Because of statistical noise in Monte Carlo dose calculations, effective point doses may not be accurate. Volume spheres are useful for evaluating dose in Monte Carlo plans, which have an inherent statistical uncertainty.We use a user-defined sphere volume instead of a point, take sphere sampling around effective point make the dose statistics to decrease the stochastic errors. Methods: Direct dose measurements were made using a 0.125cc Semiflex ion chamber (IC) 31010 isocentrically placed in the center of a homogeneous Cylindric sliced RW3 phantom (PTW, Germany).In the scanned CT phantom series the sensitive volume length of the IC (6.5mm) were delineated and defined the isocenter as the simulation effective points. All beams were simulated in Monaco in accordance to the measured model. In our simulation using 2mm voxels calculation grid spacing and choose calculate dose to medium and request the relative standard deviation ≤0.5%. Taking three different assigned IC over densities (air electron density(ED) as 0.01g/cm3 default CT scanned ED and Esophageal lumen ED 0.21g/cm3) were tested at different sampling sphere radius (2.5, 2, 1.5 and 1 mm) statistics dose were compared with the measured does. Results: The results show that in the Monaco TPS for the IC using Esophageal lumen ED 0.21g/cm3 and sampling sphere radius 1.5mm the statistical value is the best accordance with the measured value, the absolute average percentage deviation is 0.49%. And when the IC using air electron density(ED) as 0.01g/cm3 and default CT scanned EDthe recommented statistical sampling sphere radius is 2.5mm, the percentage deviation are 0.61% and 0.70%, respectivly. Conclusion: In Monaco treatment planning system for the ionization chamber 31010 recommend air cavity using ED 0.21g/cm3 and sampling 1.5mm sphere volume instead of a point dose to decrease the stochastic errors. Funding Support No.C201505006.

60 APPLIED LIFE SCIENCES↗

Making Data Prefetch Smarter: Adaptive Prefetching on POWER7

Hardware data prefetch engines are integral parts of many general purpose server-class microprocessors in the eld to- day. Some prefetch engines allow the user to change some of their parameters. The prefetcher, however, is usually enabled in a default conguration during system bring-up and dynamic reconguration of the prefetch engine is not an autonomic feature of current machines. Conceptually, however, it is easy to infer that commonly used prefetch algorithms, when applied in a xed mode will not help per- formance in many cases. In fact, they may actually de- grade performance due to useless bus bandwidth consump- tion and cache pollution. In this paper, we present an adap- tive prefetch scheme that dynamically modies the prefetch settings in order to adapt to the workload requirements. We implement and evaluate adaptive prefetching in the con- text of an existing, commercial processor, namely the IBM POWER7. Our adaptive prefetch mechanism improves per- formance with respect to the default prefetch setting up to 2.7X and 30% for single-threaded and multiprogrammed workloads, respectively. Categories