Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Covariance Matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Physicochemical and Performance Characterization of Six Commercial Organic Solvent Nanofiltration Membranes

This work introduces a novel, gradient-free metamaterial design method based on Gaussian process regression to represent the density field of a unit cell. The dimension of the design space is determined by the covariance matrix dimension in the Gaussian process regression. We propose compressing this matrix using an autoencoder, enabling the decoder to generate the density field and effectively reduce the originally large design space to a lower-dimensional subspace. In this compressed space, we employ an active learning method, Bayesian Adaptive Direct Search (BADS), for efficient exploration of the design space. We demonstrate that for simple 2D designs aimed at maximizing unit cell stiffness, our method yields results comparable to those of standard topology optimization. Furthermore, we extend our approach to various mechanical problems, from linear elasticity to hyperelastic large deformation and elasto-plasticity under finite deformation, to 3D metamaterial design. This illustrates the method’s versatility and effectiveness across a range of applications.

Wu, Haoran↗

Combination of cluster number counts and two-point correlations: validation on mock Dark Energy Survey

ABSTRACT We present a method of combining cluster abundances and large-scale two-point correlations, namely galaxy clustering, galaxy–cluster cross-correlations, cluster autocorrelations, and cluster lensing. This data vector yields comparable cosmological constraints to traditional analyses that rely on small-scale cluster lensing for mass calibration. We use cosmological survey simulations designed to resemble the Dark Energy Survey Year 1 (DES-Y1) data to validate the analytical covariance matrix and the parameter inferences. The posterior distribution from the analysis of simulations is statistically consistent with the absence of systematic biases detectable at the precision of the DES-Y1 experiment. We compare the χ2 values in simulations to their expectation and find no significant difference. The robustness of our results against a variety of systematic effects is verified using a simulated likelihood analysis of DES-Y1-like data vectors. This work presents the first-ever end-to-end validation of a cluster abundance cosmological analysis on galaxy catalogue level simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Windowed multipole representation of R -matrix cross sections

Nuclear cross sections are basic inputs to any nuclear computation. Campaigns of experiments are fitted with the parametric R-matrix model of quantum nuclear interactions, and the resulting cross sections are documented—both pointwise and as resonance parameters (with uncertainties)—in standard evaluated nuclear data libraries (ENDF, JEFF, BROND, JENDL, CENDL, TENDL): these constitute our common knowledge of fundamental low-energy nuclear cross sections. In the past decade, a collaborative effort has been deployed to establish a new nuclear cross-section library format—the Windowed Multipole Library—with the goal of considerably reducing the computational cost of cross-section calculations in nuclear transport simulations. This work lays the theoretical foundations underpinning these efforts. From general R-matrix scattering theory, we derive the windowed multipole representation of nuclear cross sections. Though physically and mathematically equivalent to R-matrix cross sections, the windowed multipole representation is particularly well suited for subsequent temperature treatment of angle-integrated cross sections, in particular Doppler broadening, which is the averaging of cross sections over the thermal motion of the target atoms. Doppler broadening is of critical importance in neutron transport applications, as it ensures the stability of many nuclear reactors (negative thermal reactivity). Yet, Doppler broadening of nuclear cross sections has been a considerable bottleneck for nuclear transport computations, often requiring memory-costly pretabulations. We show that the windowed multipole representation can perform accurate Doppler broadening analytically (up to the first reaction threshold), from which we derive cross-section temperature derivatives to any order—all computable on the fly (without precalculations stored in memory). Furthermore, we here establish a way of converting the R-matrix resonance parameters uncertainty (covariance matrices) into windowed multipole parameters uncertainty. We show that generating stochastic nuclear cross sections by sampling from the resulting windowed multipole covariance matrix can reproduce the cross-section uncertainty in the original nuclear data file. The windowed multipole representation is therefore a novel nuclear physics formalism able to generate Doppler broadened stochastic nuclear cross sections on the fly, unlocking breakthrough computational gains for nuclear computations. Through this foundational paper, we hope to make the windowed multipole representation accessible, reproducible, and usable for the nuclear physics community, as well as provide the theoretical basis for future research on expanding its capabilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Covariance Testing at BNL [Slides]

This presentation discusses testing implemented in FUDGE & ADVANCE in regard to proper ENDF formatting: STAN, STANEF, CHECKR, FUDGE, NJOY, convert to BOXR format, plotting, endfcovreport.py which is an overview of ENDF library’s covariance contents, and covariance Matrix class implements that are the core of all GNDS covariance. Several checks are performed, including symmetric, real, positive definite, condition # of Eigenvalues, and too big uncertainties. The presentation states that it can fix too big and/or small uncertainties and that it can plot matrices. It states that further testing is recommended by CSEWG but has not yet been implemented and suggests methods such as documentation which needs a human to execute, completeness which is partially complete, and reasonableness which has not been started. The presentation concludes by elaborating on reasonableness and states that only cross section is documented, that similar limits on CP reactions cross sections are needed, that maximum limits are needed too which is tricky since ENDF assumes Normal PDFs, and that there may be other observables.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NOvA Inclusive Nue CC Cross Section Data Release

NOvA inclusive electron neutrino cross section results presented at Neutrino2020Exposure:8.09E20 protons-on-target, neutrino-enhanced beamData release contains 3 ROOT files containing the double-differential measurement with respect to electron angle (cos theta) and electron energy, a single-differential measurement with respect to squared four-momentum transfer (Q2), and the total cross section as a function of neutrino energy. The 1D cross-section measurements include the same kinematic phase space restrictions present in the double-differential analysis.The files, xsec_{dThdE/Enu/dQ2}.root, contain the extracted cross section and associated covariance matrices for the double-differential cross section with respect to the observed electron kinematics, dThdE, neutrino energy, Enu, and squared four-momentum transfer, Q^2.In each file there will be the following histograms:— TH2D/TH1D xsec: unfolded measured cross section— TH2D xsec_cov: cross section covariance matrix— TH2D stat_cov: statistical covariance matrixIncludes text files, xsec_{dThdE/Enu/dQ2}.txt show the corresponding histograms in plain text format.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Controller design for the improvement of feedback properties: A method for tuning the weight in the evaluation function of the LQG theory

In the controller design of a linear time-invariant system, it is important to improve the feedback properties such as robust stability and sensitivity. In the multi-input multi-output case, these properties can be estimated by using the singular values of return difference matrix. The design method to obtain better singular-value-points is desired. How to tune the weight matrix of performance index and/or covariance matrix of noise in the Linear Quadratic Gaussian (LQC) theory to get a desired singular-value-plot was studied. First, the property of singular-value plots of return difference matrix of a system designed by LQG theory is examined from the viewpoint of tuning weight. Second, a distance between real singular-value-plots and a desired plot is defined, and the weight of performance index is numerically determined by quasi-Newton method so that the distance is minimized.

Saeki, Masami↗

Analytical and EZmock covariance validation for the DESI 2024 results

The estimation of uncertainties in cosmological parameters is an important challenge in Large-Scale-Structure (LSS) analyses. For standard analyses such as Baryon Acoustic Oscillations (BAO) and Full-Shape two approaches are usually considered. First: analytical estimates of the covariance matrix use Gaussian approximations and (nonlinear) clustering measurements to estimate the matrix, which allows a relatively fast and computationally cheap way to generate matrices that adapt to an arbitrary clustering measurement. On the other hand, sample covariances are an empirical estimate of the matrix based on an ensemble of clustering measurements from fast and approximate simulations. While more computationally expensive due to the large amount of simulations and volume required, these allow us to take into account systematics that are impossible to model analytically. In this work we compare these two approaches in order to enable DESI's key analyses. We find that the configuration space analytical estimate performs satisfactorily in BAO analyses and its flexibility in terms of input clustering makes it the fiducial choice for DESI's 2024 BAO analysis. On the contrary, the analytical computation of the covariance matrix in Fourier space does not reproduce the expected measurements in terms of Full-Shape analyses, which motivates the use of a corrected mock covariance for DESI's 2024 Full Shape analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Power series evaluation of transition and covariance matrices.

Reexamination power series solutions to the matrix covariance differential equation and the transition differential equation. Truncation error bounds are derived which are computationally attractive and which extend previous results. Polynomial approximations are obtained by exploiting the functional equations satisfied by the transition and covariance matrices. The series-functional equation propagation technique represents a fast and accurate alternative to the numerical integration of the time-invariant transition and covariance equations.

Bierman, G. J.↗

CrysFieldExplorer : rapid optimization of the crystal field Hamiltonian

A new approach to the fast optimization of crystal electric field (CEF) parameters to fit experimental data is presented. This approach is implemented in a lightweight Python-based program, CrysFieldExplorer. The main novelty of the method is the development of a unique loss function, referred to as the spectrum characteristic loss (L Spectrum ), which is based on the characteristic polynomial of the Hamiltonian matrix. Particle swarm optimization and a covariance matrix adaptation evolution strategy are used to find the minimum of the total loss function. It is demonstrated that CrysFieldExplorer can perform direct fitting of CEF parameters to any experimental data such as a neutron spectrum, susceptibility or magnetization measurements etc. CrysFieldExplorer can handle a large number of non-zero CEF parameters and reveal multiple local and global minimum solutions. Crystal field theory, the loss function, and the implementation and limitations of the program are discussed within the context of two examples.

42 ENGINEERING↗

Generalized covariance analysis for partially autonomous deep space missions

A new covariance analysis method is presented that is suitable for the evaluation of multiple impulsive controllers acting on some stochastic process x. The method accommodates batch and sequential estimators with equal ease and accounts for time-delay effects in a natural manner. The formalism is developed in terms of a generalized state vector that is formed from the system state vector x, augmented by various fixed epoch estimates, and a data vector formed from discrete time observations of the system. Recursions are developed for time transition, measurement incorporation, and impulsive control updating of the generalized covariance matrix. Means of limiting the dimensional growth of the generalized state vector via the processes of estimator epoch adjustment and measurement vector deflation are described and the application of numerically stable matrix factorization methods to the generalized covariance recursions is outlined. The method is applied to the Magellan spacecraft to demonstrate the capability of ground-based optimal estimation and control of gyro/star scanner misalignment.

Boone, Jack N.↗

Monte Carlo Perturbation Analysis of Fuel Temperature Variations in the MCNP Model of the Annular Core Research Reactor

The Annular Core Research Reactor (ACRR) Monte Carlo N-Particle (MCNP) model is used by ACRR reactor operators and experiment designers at Sandia National Laboratories for a variety of computational calculations ranging from reactor kinetics parameter estimates and safety analyses to experimental planning. To understand the dominant source of uncertainty within the MCNP model, perturbations in temperature were applied to individual ACRR MCNP fuel rods. Fuel rod temperatures were randomly sampled from a uniform distribution from operational temperatures to quantify temperature-related uncertainty effects. Stochastic mixing was used to blend the cross sections of the desired temperatures using the MCNP continuous and Thermal Neutron Scattering Treatment [S(α,β)] libraries in ENDF/B-VII.1. Furthermore, this uncertainty analysis produced a 640 row × 640 column correlation and covariance matrix of the neutron energy spectra. Positive covariance was produced around the 1-MeV region and the 0.2-eV region. Correlation was found in the thermal and fast energy regions, but no correlation was observed in the slowing-down energy region because interactions in this region are not dominated by fuel.

ACRR↗

HYMPS: Numerical Techniques

The digital calculations that drive the classification portion of the Hybrid Pattern Recognition System (HYMPS) are considered. A revision of these calculations is suggested that involves three items: matrix inversion, det calculations and singularity, and covariance factorization. It is shown that it is more economical to first factor the covariance matrix, and by so doing, delete the matrix inversion routine. In addition, the necessary det calculations can be more easily realized by use of simple theoretical facts about the factorization.

Decell, H. P., Jr.↗

Kalman Filtering of Angular-Momentum-Based Attitude Parameters

This paper presents an extended Kalman filter using an attitude parameterization that is advantageous for attitude estimation of spinning spacecraft. The parameters are the angular momentum components in an inertial reference frame, the angular momentum components in the body frame, and a rotation angle. To avoid the singularity of the 7x7 covariance of this state vector arising from the constraint that the magnitude of the angular momentum vector is the same in the inertial and body frames, the Kalman filter employs the nonsingular 6x6 covariance of a reduced error state. Three of the components of this six-component error state are the usual infinitesimal attitude error angles, so the usual 3x3 attitude covariance matrix is a submatrix of the 6x6 covariance. The performance of the resulting filter is compared with that of a quaternion-based filter.

Markley, F. Landis↗

The Effects of Noise on Polarimetric SAR Data

Polarimetric SAR data can provide a great deal of information about the scattering behavior of the surface under observation. Polarimetric SAR systems often measure the scattering matrices of the areas under observation in linear polarizations (H and V). From the scattering matrix commonly used forms such as the covariance matrix and the Stokes matrix can be easily derived. Other measures derived from polarimetric SAR data include the standard deviation of texture, correlation coefficients between scattering matrix terms, and the mode and variance of phase differences between scattering matrix terms. The effects of additive system noise on these measurements is not often considered in the literature on this subject.

Polarimetric SAR Data analysis↗