Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16-channel RF coil

Purpose: This study aims to develop, implement, and evaluate a 16-channel radiofrequency (RF) coil for integrated positron emission tomography/magnetic resonance (PET/MR) imaging of breast cancer. The RF coil is designed for optimized MR imaging performance and PET transparency and attenuation correction (AC) is applied for accurate PET quantification. Methods: A 16-channel breast array RF coil was designed for integrated PET/MR hybrid imaging of breast cancer lesions. The RF coil features a lightweight rigid design and is positioned with a spacer at a defined position on the patient table of an integrated PET/MR system. Attenuation correction is performed by generating and applying a dedicated 3D CT-based template attenuation map. Reposition accuracy of the RF coil on the system patient table while using the positioning frame was tested in repeated measurements using MR-visible markers. The MR, PET, and PET/MR imaging performances were systematically evaluated using modular breast phantoms. Attenuation correction of the RF coil was evaluated with difference measurements of the active breast phantoms filled with radiotracer in the PET detector with and without the RF coil in place, serving as a standard of reference measurement. The overall PET/MR imaging performance and PET quantification accuracy of the new 16-channel RF coil and its AC were then evaluated in first clinical examinations on ten patients with local breast cancer. Results: The RF breast array coil provides excellent signal-to-noise ratio and signal homogeneity across the volume of the breast phantoms in MR imaging and visualizes small structures in the phantoms down to 0.4 mm in plane. Difference measurements with PET revealed a global loss and thus attenuation of counts by 13% (mean value across the whole phantom volume) when the RF coil is placed in the PET detector. Local attenuation ranging from 0% in the middle of the phantoms up to 24% was detected in the peripheral regions of the phantoms at positions closer to attenuating hardware structures of the RF coil. The position accuracy of the RF coil on the patient table when using the positioning frame was determined well below 1 mm for all three spatial dimensions. This ensures perfect position match between the RF coil and its three-dimensional attenuation template during the PET data reconstruction process. When applying the CT-based AC of the RF coil, the global attenuation bias was mostly compensated to ±0.5% across the entire breast imaging volume. The patient study revealed high quality MR, PET, and combined PET/MR imaging of breast cancer. Quantitative activity measurements in all 11 breast cancer lesions of the ten patients resulted in increased mean difference values of SUV{sub max} 11.8% (minimum 3.2%; maximum 23.2%) between nonAC images and images when AC of the RF breast coil was applied. This supports the quantitative results of the phantom study as well as successful attenuation correction of the RF coil. Conclusions: A 16-channel breast RF coil was designed for optimized MR imaging performance and PET transparency and was successfully integrated with its dedicated attenuation correction template into a whole-body PET/MR system. Systematic PET/MR imaging evaluation with phantoms and an initial study on patients with breast cancer provided excellent MR and PET image quality and accurate PET quantification.

60 APPLIED LIFE SCIENCES↗

NCSX Trim Coil Design

The National Compact Stellarator Experiment (NCSX) was being constructed at the Princeton Plasma Physics Laboratory in partnership with Oak Ridge National Laboratory before work was stopped in 2008. The objective of this experiment was to develop the stellarator concept and evaluate it's potential as a model for future fusion power plants. Stellarator design requires very precisely positioned Modular Coils of complex shape to form 3D plasmas. In the design of NCSX, Trim Coils were required to compensate for both the positioning of the coils during assembly and the fabrication tolerances of the Modular Coils. Use of the Trim Coils allowed for larger tolerances increasing ease of assembly and decreasing overall cost. A set of Trim coils was developed to suppress the toroidal flux in island regions due to misalignment, magnetic materials, and eddy currents. The requirement imposed upon the design forced the toroidal flux in island regions below 10% of the total toroidal flux in the plasma. An analysis was first performed to evaluate candidate Trim Coil configurations iterating both the size, number, and position of the coils. The design was optimized considering both performance and cost while staying within the tight restraints presented by the space limited geometry. The final design of the Trim Coils incorporated a 48 Coil top bottom symmetric set. Fabrication costs were minimized by having only two coil types and using a planar conventional design with off the shelf commercial conductor. The Trim Coil design incorporated supports made from simple structural shapes assembled together in a way which allowed for adjustment as well as accommodation for the tolerance build up on the mating surfaces. This paper will summarize the analysis that led to the optimization of the Trim Coils set, the trim coil mechanical design, thermal and stress analysis, and the design of the supporting Trim Coil structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and Test of a Large Aperture $Nb_3Sn$ Cos-Theta Dipole Coil with Stress Management

An innovative stress-management (SM) concept for cos-theta (CT) coils (SMCT coil concept) has been proposed at Fermilab. A large-aperture two-layer Nb3Sn SMCT dipole coil was designed and manufactured to validate and test the SM concept including coil design, fabrication technology, and performance. The first large-aperture SMCT coil (SMCT1) was fabricated and assembled with a small-aperture Nb3Sn coil inside a dipole mirror magnet. SMCT1 coil tests in a dipole mirror structure was performed in two configurations - SMCTM1a with only powered two-layer SMCT1 coil and SMCTM1b with the SMCT coil connected in series with an inner two-layer dipole coil. The test goals are to prove the SMCT coil concept in two-layer and four-layer mirror configurations; demonstrate that the magnet can reach the targeted quench current at the established preload; study magnet training, training memory after thermal cycle, ramp rate and temperature dependences of the magnet quench current; and test the SMCT1 coil quench protection parameters. This paper summarizes the SMCT1 coil design and parameters, the coil main fabrication steps, its assembly in the dipole mirror structure. The results of the SMCTM1a/b mirror test are presented and discussed.

43 PARTICLE ACCELERATORS↗

Mid-Range Coil Array for Magnetic Resonance Imaging of Small Animals

The vast majority of articles on MRI RF coils over the past two decades have focused on large coils, where sample losses dominate, or on micro-coils, where sample and capacitor losses are negligible. Few have addressed the mid-range coils, seen in the majority of small-animal applications, where all the sources of loss are important, for example, mouse brain and body coils from 125 to 750 MHz. We developed a four-saddle coil array for magnetic resonance imaging of small animals. The saddle coil elements in the array were evenly distributed to cover the rat's head. The coil array was tuned to the resonant frequency of 170 MHz. Due to the close proximity of the coil elements, it was necessary to decouple the coil array using nonmagnetic trimmers and, it was operated in the transceiver mode and quadrature-driven. To test the coil array performance at high field, phantom images were acquired with our saddle coil array and standard pulse sequences on a research-dedicated 4 Tesla scanner. Ex vivo brain images of a rat were also acquired, and proved the feasibility of the scaled version of a saddle coil array and, its compatibility with standard pulse sequences when used in a high field magnetic resonance imager.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A multi-slot surface coil for MRI of dual-rat imaging at 4T

A slotted surface coil inspired by the hole-and-slot cavity magnetron was developed for magnetic resonance imaging of obese rats at 4 T. Full-wave analysis of the magnetic field was carried out at 170 MHz for both the slotted and circular-shaped coils. The noise figure values of two coils were investigated via the numerical calculation of the quality factors. Fat simulated phantoms to mimic overweight rats were included in the analysis with weights ranging from 300 to 900 g. The noise figures were 1.2 dB for the slotted coil and 2.4 dB for the circular coil when loaded with 600 g of simulated phantom. A slotted surface coil with eight circular slots and a circular coil with similar dimensions were built and operated in the transceiver mode, and their performances were experimentally compared. The imaging tests in phantoms demonstrated that the slotted surface coil has a deeper RF-sensitivity and better field uniformity than the single-loop RF-coil. High quality images of two overweight Zucker rats were acquired simultaneously with the slotted surface coil using standard spin-echo pulse sequences. Experimental results showed that the slotted surface coil outperformed the circular coil for imaging considerably overweight rats. Thus, the slotted surface coil can be a good tool for MRI experiments in rats on a human whole-body 4 T scanner.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coil optimization for quasi-helically symmetric stellarator configurations

Filament-based coil optimizations are performed for several quasi-helical stellarator configurations, beginning with the one from Landreman & Paul ( Phys. Rev. Lett. , vol. 128, 2022, 035001), demonstrating that precise quasi-helical symmetry can be achieved with realistic coils. Several constraints are placed on the shape and spacing of the coils, such as low curvature and sufficient plasma–coil distance for neutron shielding. The coils resulting from this optimization have a maximum curvature 0.8 times that of the coils of the Helically Symmetric eXperiment (HSX) and a mean squared curvature 0.4 times that of the HSX coils when scaled to the same plasma minor radius. When scaled up to reactor size and magnetic field strength, no fast particle losses were found in the free-boundary configuration when simulating 5000 alpha particles launched at $3.5\,\mathrm {MeV}$ on the flux surface with a normalized toroidal flux of $s=0.5$ . An analysis of the tolerance of the coils to manufacturing errors is performed using a Gaussian process model, and the coils are found to maintain low particle losses for smooth, large-scale errors up to amplitudes of approximately $0.15\,\mathrm {m}$ . Another coil optimization is performed for the Landreman–Paul configuration with the additional constraint that the coils are purely planar. Visual inspection of the Poincaré plot of the resulting magnetic field-lines reveal that the planar modular coils alone do a poor job of reproducing the target equilibrium. Additional non-planar coil optimizations are performed for the quasi-helical configuration with $5\,\%$ volume-averaged plasma beta from Landreman et al. ( Phys. Plasma , vol. 29, issue 8, 2022, 082501), and a similar configuration also optimized to satisfy the Mercier criterion. The finite beta configurations had larger fast-particle losses, with the free-boundary Mercier-optimized configuration performing the worst, losing approximately $5.5\,\%$ of alpha particles launched at $s=0.5$ .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing multi-modal, non-axisymmetric plasma response metrics with additional coil rows on DIII-D

The expansion of the DIII-D tokamak operational space via the addition of new non-axisymmetric coil rows is investigated using the linear MHD plasma response code MARS-F. The plasma response to magnetic perturbations imposed by five distinct low- and high-field side coil geometries is modeled for toroidal mode numbers up to n = 6. A set of linear (~δB^2: resonant, kink mode amplitude) and quadratic (~δB: core and edge integrated NTV torque) plasma metrics are defined and compared directly for the various coil geometries. Coil size is also scanned as a secondary optimization variable. An in-vessel coil located at the low-field side midplane is identified as the most efficient plasma response actuator across all metrics and toroidal mode numbers. The multi-row combination of this new midplane (M) coil with the existing DIII-D non-axisymmetric coil set is considered in numerical optimization studies to quantify the impact of this new coil on modeled plasma response metrics. The addition of the M coil is shown to significantly increase the actuator efficiency in maximizing individual plasma response metrics as well as maximizing multi-modal ratios of response metrics, e.g. maximizing resonant modes or edge NTV torque while minimizing kink modes or core NTV torque. The ex-vessel midplane (C) coil is also observed to have an outsize effect on multi-modal optimization due to its uniquely narrow poloidal spectra, and the expansion of optimization space due to the combined use of the two existing in-vessel coil rows with both the M and C coils is notably larger than either coil's individual contribution even though both share similar poloidal locations. This four-row system is expected to greatly extend abilities to understand and optimize the control of transients and rotation on the DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Composites and additive manufacturing for high-field coil supports for stellarators

The utilization of composites layered on an additive manufactured substrate, for the production of coil supports for modular coils in small or middle size experimental stellarators is assessed. The focus of the study is a monolithic coil support comprising the coils of a half-period of a stellarator, somewhat similar to the ones in UST_2 and ARIES-CS stellarators. However, the concept may be applicable to quasi-monolithic coil supports (coil forms of NCSX type) or individual coil casings (W7-X type).Coil supports for stellarators require high precision, stiffness and strength for large contorted parts. Traditionally, monolithic coil supports are produced by steel casting/forging and final machining. This production method and material gives accurate, stiff and strong coil supports, but the method may be expensive for monolithic supports due to the geometrical complexity and required accuracy of the structure. In relation to those matters, this work investigates whether a monolithic coil support comprising an additive manufactured resin substrate, which is externally (outward from the coils) surrounded with a thick layer of fibre-reinforced resin, may achieve enough strength and stiffness under middle/high magnetic fields. Finite element calculations are produced to obtain the direction of the principal stresses and their values in compression and tension at different areas of the monolithic support, which is relevant for anisotropic materials. The feasibility of directional application of (carbon) fibres on the winding surface of the stellarator outward from the coils is experimentally tested on a scaled-down additively manufactured prototype of a monolithic support. The strength and stiffness of the composite structure appears sufficient for common magnetic fields in experimental stellarators, and the 3D-composite design and manufacturing was technically feasible.

Queral, Vicente↗

A six-channel pediatric coil array for detection of children spinal pathologies by MRI at 1.5 Tesla

Nowadays, magnetic resonance (MR) in Mexico has become a standard technique for clinical imaging. Although most of the times the MR systems contain only coils oriented for adults. Radiologists use these coils for children studies due to the non-availability of pediatric coils. Image quality is decreased due to the low signal to noise ratio delivered to the system. The development of RF coils is always focused towards increasing SNR and optimizing the RF penetration into the sample. Moreover, spinal pathologies in children, which are an important topic in pediatric care, cover congenital and neuromuscular disorders that occur in childhood. In this work, the design of a dedicated six-channel coil for detection of spinal pathologies at 1.5 Tesla is addressed. Numerical electromagnetic simulations were performed in order to evaluate their magnetic field performance at (63.6 MHz) 1.5 Tesla. The magnetic field uniformity as well as the RF penetration depth of the coil configurations was evaluated in order to find the best/optimized coil array configuration. The coil is comprised of three rows, one with 4 coil elements and two with only one coil element. Phantom and in vivo images were acquired with the six-channel pediatric coil array. The phantom images agree with the simulated data. In vivo images acquired with the 6-channel pediatric coil array have shown very good penetration depth and homogeneity, which allow better image quality throughout the whole FOV. In addition, the parallel imaging capabilities of the array allow the acceleration of the experiments avoiding possible motion artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A flexible and differentiable coil proxy for stellarator equilibrium optimization

Balancing plasma performance and coil cost is a significant challenge when designing a stellarator power plant. Most current stellarator designs are produced through two-stage optimization: stage-1 for the equilibrium and stage-2 for a coil design that reproduces its magnetic configuration. Because few proxies connect both stages, two-stage optimization can produce plasmas that have high-quality physical properties but overly complex coils. In recent years, single-stage optimization has increasingly been used to optimize the plasma and coils simultaneously in order to improve the plasma–coil balance. However, all existing single-stage tools are specialized for filament coils, cannot model coil systems containing permanent magnets or dipole arrays, and continue to be challenged by numerical problems. The quasi-single-stage optimization finds a middle ground by integrating a coil optimization subproblem into stage-1 optimization. We present a flexible, differentiable coil complexity proxy based on the newly developed QUADCOIL coil optimization code. QUADCOIL is fast and can target realistic coil metrics and constraints that are unavailable to codes with comparable speed. We demonstrate the effectiveness and flexibility of the QUADCOIL proxy by presenting two QSS optimization studies. The first study produces a permanent magnet solution for the MUSE stellarator with 34% fewer magnets than previous solutions. The second study produces a coil solution for the ARIES-CS stellarator with 30% reductions in both peak and root-mean-square force.

Fu, Lanke [Princeton Plasma Physics Laboratory (PP↗

The magnetic gradient scale length explains why certain plasmas require close external magnetic coils

Abstract The separation between the last closed flux surface of a plasma and the external coils that magnetically confine it is a limiting factor in the construction of fusion-capable plasma devices. This plasma-coil separation must be large enough so that components such as a breeding blanket and neutron shielding can fit between the plasma and the coils. Plasma-coil separation affects reactor size, engineering complexity, and particle loss due to field ripple. For some plasmas it can be difficult to produce the desired flux surface shaping with distant coils, and for other plasmas it is infeasible altogether. Here, we seek to understand the underlying physics that limits plasma-coil separation and explain why some configurations require close external coils. In this paper, we explore the hypothesis that the limiting plasma-coil separation is set by the shortest scale length of the magnetic field as expressed by the ∇ B tensor. We tested this hypothesis on a database of > 40 stellarator and tokamak configurations. Within this database, the coil-to-plasma distance compared to the minor radius varies by over an order of magnitude. The magnetic scale length is well correlated to the coil-to-plasma distance of actual coil designs generated using the REGCOIL method (Landreman 2017 Nucl. Fusion 57 046003). Additionally, this correlation reveals a general trend that larger plasma-coil separation is possible with a small number of field periods.

Physics↗

Effect of Inductive Coil Geometry and Current Sheet Trajectory of a Conical Theta Pinch Pulsed Inductive Plasma Accelerator

Results are presented demonstrating the e ect of inductive coil geometry and current sheet trajectory on the exhaust velocity of propellant in conical theta pinch pulsed induc- tive plasma accelerators. The electromagnetic coupling between the inductive coil of the accelerator and a plasma current sheet is simulated, substituting a conical copper frustum for the plasma. The variation of system inductance as a function of plasma position is obtained by displacing the simulated current sheet from the coil while measuring the total inductance of the coil. Four coils of differing geometries were employed, and the total inductance of each coil was measured as a function of the axial displacement of two sep- arate copper frusta both having the same cone angle and length as the coil but with one compressed to a smaller size relative to the coil. The measured relationship between total coil inductance and current sheet position closes a dynamical circuit model that is used to calculate the resulting current sheet velocity for various coil and current sheet con gura- tions. The results of this model, which neglects the pinching contribution to thrust, radial propellant con nement, and plume divergence, indicate that in a conical theta pinch ge- ometry current sheet pinching is detrimental to thruster performance, reducing the kinetic energy of the exhausting propellant by up to 50% (at the upper bound for the parameter range of the study). The decrease in exhaust velocity was larger for coils and simulated current sheets of smaller half cone angles. An upper bound for the pinching contribution to thrust is estimated for typical operating parameters. Measurements of coil inductance for three di erent current sheet pinching conditions are used to estimate the magnetic pressure as a function of current sheet radial compression. The gas-dynamic contribution to axial acceleration is also estimated and shown to not compensate for the decrease in axial electromagnetic acceleration that accompanies the radial compression of the plasma in conical theta pinches.

Hallock, Ashley K.↗

Two-Slotted Surface Coil Array for Magnetic Resonance Imaging at 4 Tesla

Arrays of antennas have been widely accepted for magnetic resonance imaging applications due to their high signal-to-noise ratio (SNR) over large volumes of interest. A new surface coil based on the magnetron tube and called slotted surface coil, has been recently introduced by our group. This coil design experimentally demonstrated a significant improvement over the circular-shaped coil when used in the receive-only mode. The slotted coils formed a two-sheet structure with a 90 deg. separation and each coil had 6 circular slots. Numerical simulations were performed using the finite element method for this coil design to study the behaviour of the array magnetic field. Then, we developed a two-coil array for brain magnetic resonance imaging to be operated at the resonant frequency of 170 MHz in the transceiver mode. Phantom images were acquired with our coil array and standard pulse sequences on a research-dedicated 4 Tesla scanner. Numerical simulations demonstrated that electromagnetic interaction between the coil elements is negligible, and that the magnetic field showed a good uniformity. In vitro images showed the feasibility of this coil array for standard pulses for high field magnetic resonance imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Numerical Study of a Crossed Loop Coil Array for Parallel Magnetic Resonance Imaging

A coil design has been recently proposed by Temnikov (Instrum Exp Tech. 2005;48;636-637), with higher experimental signal-to-noise ratio than that of the birdcage coil. It is also claimed that it is possible to individually tune it with a single chip capacitor. This coil design shows a great resemble to the gradiometer coil. These results motivated us to numerically simulate a three-coil array for parallel magnetic resonance imaging and in vivo magnetic resonance spectroscopy with multi nuclear capability. The magnetic field was numerical simulated by solving Maxwell's equations with the finite element method. Uniformity profiles were calculated at the midsection for one single coil and showed a good agreement with the experimental data. Then, two more coils were added to form two different coil arrays: coil elements were equally distributed by an angle of a 30 deg. angle. Then, uniformity profiles were calculated again for all cases at the midsection. Despite the strong interaction among all coil elements, very good field uniformity can be achieved. These numerical results indicate that this coil array may be a good choice for magnetic resonance imaging parallel imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and Construction of a Prototype Solenoid Coil for MICE Coupling Magnets

A superconducting coupling solenoid mounted around four conventional RF cavities, which produces up to 2.6 T central magnetic field to keep the muons within the cavities, is to be used for the Muon Ionization Cooling Experiment (MICE). The coupling coil made from copper matrix NbTi conductors is the largest of three types of magnets in MICE both in terms of 1.5 m inner diameter and about 13MJ stored magnetic energy at full operation current of 210A. The stress induced inside the coil assembly during cool down and magnet charging is relatively high. In order to validate the design method and develop the coil winding technique with inside-wound SC splices required for the coupling coil, a prototype coil made from the same conductor and with the same diameter and thickness but only one-fourth long as the coupling coil was designed and fabricated by ICST. The prototype coil was designed to be charged to strain conditions that are equivalent or greater than would be encountered in the coupling coil. This paper presents detailed design of the prototype coil as well as developed coil winding skills. The analyses on stress in the coil assembly and quench process were carried out.

42 ENGINEERING↗

Electromagnetic and Mechanical Analysis of the Coil Structure for the CLAS12 Torus for 12 GeV Upgrade

The torus magnet for the CLAS12 spectrometer is a 3.6 T superconducting magnet being designed and built as part of the Jefferson Lab 12 GeV Upgrade. The magnet consists of six coil case assemblies mounted to a cold central hub. The coil case assembly consists of an aluminum case and cover enclosing an epoxy vacuum impregnated coil pack. The coil pack consists of a 117 turn double-pancake winding wrapped with 2 layers of 0.635 mm thick copper cooling sheets. The coil case assembly is cooled by supercritical helium at 4.6 K. This report details the structural analysis of the coil case assembly and the assessment of the coil pack stresses. For the normal operation of the torus magnet, the coil case assembly was analyzed for cool down to 4.6 K and the Lorentz forces at normal operating current. In addition to the normal operating configuration, the coil case assembly was analyzed for Lorentz forces arising from coil misalignment and current imbalances. The allowable stress criteria for the magnet followed the approach of the ASME codes. Primary stresses were limited to the lesser of 2/3 times the yield strength or 1/3 times the ultimate tensile strength. Primary plus secondary stresses were limited to 3 times the primary stress allowable. The analysis was performed using ANSYS Maxwell to calculate the magneto-static loads and ANSYS Mechanical to calculate the stresses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic coil optimization for reduced Lorentz forces

Abstract The reduction of magnetic forces on electromagnetic coils is an important consideration in the design of high-field devices such as the stellarator or tokamak. Unfortunately, these forces may be too time-consuming to evaluate by conventional finite element modeling within an optimization loop. Although mutual forces can be computed rapidly by approximating large-bore coils as infinitely thin, this approximation does not hold for self-forces as it leads to an unphysical divergence. Recently, a novel reduced model for the self-field, self-force, and self-inductance of electromagnetic coils based on filamentary models was rigorously derived and demonstrated to be highly accurate and numerically efficient to evaluate (Hurwitz et al 2024 IEEE Trans. Magn. 60 7001614). In this paper, we present an implementation of the reduced self-force model employing automatic differentiation within the simsopt stellarator design software and use it in derivative-based coil optimization for a quasi-axisymmetric stellarator. We show that it is possible to significantly reduce point-wise forces throughout the coils, though this comes with trade-offs to fast particle losses and the minimum distance between coils and the plasma surface. The trade-off between magnetic forces and coil-surface distance is mediated by the minimum coil–coil distance for coils near the inboard side of the ‘bean’ cross-section of the plasma. The relationship between forces and fast particle losses is mediated by the normal field error. Coil forces can be lowered to a threshold with minimal deterioration to losses. Importantly, the magnet optimization approach here can be used also for tokamaks, other fusion concepts, and applications outside of fusion.

Hurwitz, Siena (ORCID:0000000166599659)↗

CLOSURE OF HLW TANKS FORMULATION FOR A COOLING COIL GROUT

The Tank Closure and Technology Development Groups are developing a strategy for closing the High Level Waste (HLW) tanks at the Savannah River Site (SRS). Two Type IV tanks, 17 and 20 in the F-Area Tank Farm, have been successfully filled with grout. Type IV tanks at SRS do not contain cooling coils; on the other hand, the majority of the tanks (Type I, II, III and IIIA) do contain cooling coils. The current concept for closing tanks equipped with cooling coils is to pump grout into the cooling coils to prevent pathways for infiltrating water after tank closure. This task addresses the use of grout to fill intact cooling coils present in most of the remaining HLW tanks on Site. The overall task was divided into two phases. Phase 1 focused on the development of a grout formulation (mix design) suitable for filling the HLW tank cooling coils. Phase 2 will be a large-scale demonstration of the filling of simulated cooling coils under field conditions using the cooling coil grout mix design recommended from Phase 1. This report summarizes the results of Phase 1, the development of the cooling coil grout formulation. A grout formulation is recommended for the full scale testing at Clemson Environmental Technology Laboratory (CETL) that is composed by mass of 90% Masterflow (MF) 816 (a commercially available cable grout) and 10% blast furnace slag, with a water to cementitious material (MF 816 + slag) ratio of 0.33. This formulation produces a grout that meets the fresh and cured grout requirements detailed in the Task Technical Plan (2). The grout showed excellent workability under continuous mixing with minimal change in rheology. An alternative formulation using 90% MF 1341 and 10% blast furnace slag with a water to cementitious material ratio of 0.29 is also acceptable and generates less heat per gram than the MF 816 plus slag mix. However this MF 1341 mix has a higher plastic viscosity than the MF 816 mix due to the presence of sand in the MF 1341 cable grout and a lower water to solids ratio. Nevertheless, the higher viscosity grout may still meet the requirements for the cooling coil grout under certain pumping conditions or alternatively, the mix may be made more fluid by a short period of high shear mixing during production. The mixes have not been optimized for large scale production. It may be possible, for example, to adjust the water to cementitious materials ratio to provide improved performance of these mixes based on the results and conclusions of the large scale testing at CETL. Recommendations from this task include incorporation of a backup mixing/pumping system that is either integrated into the system or is available for immediate use in case of a pump or mixer failure of the primary system. A second recommendation is to conduct a laboratory scale investigation to determine the impact of operational variation on the properties of the grout. This effort would be initiated after feedback is received from the large scale testing at CETL. The purpose of this proposed variability testing is to better understand the limits of the operational variations (such as temperature and mixing time), and to identify possible approaches for remediation to ensure that the grout produced will flow effectively in the coils while still meeting the performance requirements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗