Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CoP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Effect of Long-Duration Spaceflight on Postural Control During Self-Generated Perturbations

This report is the first systematic evaluation of the effects of prolonged weightlessness on the bipedal postural control processes during self-generated perturbations produced by voluntary upper limb movements. Spaceflight impacts humans in a variety of ways, one of which is compromised postflight postural control. We examined the neuromuscular activation characteristics and center of pressure motion (COP) associated with arm movement of eight subjects who experienced long duration spaceflight (3-6 months) aboard the Mir space station. Surface electromyography (EMG), arm acceleration, and COP motion were collected while astronauts performed rapid unilateral shoulder flexions prior to and after spaceflight. Subjects displayed compromised postural control after flight as evidenced by modified peak-to-peak COP anterior-posterior and medio-lateral motion and COP pathlength relative to preflight values. These changes were associated with disrupted neuromuscular activation characteristics, particularly after the completion of arm acceleration (i.e. when subjects were attempting to maintain their upright posture). These findings suggest that although the subjects were able to assemble coordination modes that enabled them to generate rapid arm movements, the subtle control necessary to maintain bipedal equilibrium evident in their preflight performance is compromised after long duration spaceflight.

Layne, Charles S.↗

U.S. Spacesuit Knowledge Capture – Creation, Curation, and Dissemination

The U.S. spacesuit is a special system that has intrigued and fascinated the world since Neil Armstrong set foot on the Moon in 1969. With over 50 years since that momentous achievement, NASA is planning to land the first woman and next man on the Moon in the near future. This goal begets the need to build a new spacesuit, a spacesuit created from the legacy knowledge of the Extravehicular Mobility Unit (EMU), combined with knowledge gained from technology development over the decades. As NASA transitions to its new horizon, the U.S. Spacesuit Knowledge Capture (SKC) Program is poised to help. The SKC Program’s primary function has been to capture, curate, and disseminate spacesuit-related knowledge among scientists, engineers, and technicians. The SKC Program was created in 2007 to capture knowledge primarily from spacesuit subject-matter experts (SMEs) who were retiring from NASA. These SMEs had 30 to 50 years of spacesuit knowledge. Over the years, the SKC Program has evolved and expanded its scope with a current focus on complementing the buildup of the Exploration EMU (xEMU) at the Johnson Space Center. As part of this focus, the SKC Program recently teamed with the xEMU Community of Practice (CoP) for knowledge sharing. The xEMU CoP provides a forum where early career engineers, professionals new to human spaceflight, and the xEMU community can come together regularly to seek guidance, share knowledge, meet their peers, discover resources, and ask questions. The CoP created an environment where the knowledge can be easily and routinely captured and recorded. The recorded events are archived and curated in an SKC Program library and disseminated as appropriate. This paper details the roles that the SKC Program and CoP play in the xEMU buildup, along with the navigation of the creation, curation, and dissemination processes.

Cinda Chullen↗

Human Stability While Exercising on a VIS Device in Zero Gravity

BACKGROUND: A Vibration Isolation and Stabilization (VIS) system is being designed for use with the European Enhanced Exploration Exercise Device (E4D) [1]. The exercise bar is attached to cables that extend and retract through openings in the E4D platform, which the subject stands on while exercising. Since the E4D is mounted on a moving VIS device, the whole system moves under the subject’s feet. While tension in the cables does help stabilize a crew member in 0g by bracing him or her against the moving platform, flexible cables do not offer full support against falling. This raises the question of whether various exercises that are successfully performed in 1g on a stationary device can be performed without losing balance in 0g on a moving device. Quantifying stability conditions and establishing stability requirements for exercise countermeasure systems is a long-standing challenge and this work helped to inform this specific need for integrated E4D/VIS flight project development. METHODS AND RESULTS: A simplified stability analysis can be attempted based on platform accelerations generated by the VIS device simulation. In this type of analysis, the subject is conceived as standing on the platform in 0g while being held down to it by the tension in the cables. If the sideways acceleration of the platform is such that the cables cannot generate a sufficient moment relative to, e.g., the heels or the toes of the subject to overcome the tipping moment from the inertial forces on the accelerated subject’s body, the subject becomes unstable. This approach, which we refer to as the ‘static’ approximation, indicated failure of all the exercises that were considered in the comprehensive VIS analysis of the E4D. It was realized, however, that platform accelerations are not externally imposed but are themselves induced by the motion of the subject’s body during exercise, and a model calculation confirmed that this drastically altered the tipping moment on the subject, with the potential to even switch the direction in which the body would tip over. This made it imperative to consider in a coupled manner both the motion of the exercising subject’s body and the induced VIS platform motion while considering stability. The coupled dynamics requirement was met by the VIS simulation incorporating time-dependent human mass properties atop the platform and driven by the inertial forces from the prescribed subject motion relative to the platform based on motion-capture recorded human trajectories in 1g on a stationary E4D [2]. To analyze simulation results, a stability criterion was also needed. We do not know how to account for the human ‘control system’ that would take visual and vestibular cues as inputs as the platform moves in 0g. We thus chose to follow an approach we had previously used to analyze the dynamic feasibility of performing a task in lunar gravity along the human body trajectory recorded in 1g [3]. In this approach, one analyzes the center of pressure (COP) between the shoes and the ground (or platform) and checks if the COP remains within the convex hull of the footprints on the ground (or platform), commonly referred to as base of support (BOS). Since pressure is vertical and, in the absence of foot restraints, positive, the COP going outside the BOS indicates that the trajectory recorded in 1g is not dynamically feasible in microgravity and/or on the moving platform of the device. The outcome of the COP-based analysis was that some of the key exercises, especially the deadlift and the back squat exercises, were found to be dynamically feasible for at least some number of the exercise cycles, this number increasing with the cable tension. While this type of stability analysis does not account for the likely alteration of the exercise trajectory from its 1g form in space, it does show that there exist at least some realistic trajectories that pass the dynamic feasibility criterion. This adds confidence that, with further adjustment by the subject of the exercise form in 0g on a moving device, a number of exercises can be performed without losing balance.

D Frenkel↗

PERFORMANCE ASSESSMENT ASSISTANCE ACTIVITIES IN THE DOE COMPLEX

The United States Department of Energy Office of Environmental Management (DOE-EM) has established a Performance Assessment Community of Practice (PA CoP) to foster the sharing of information among performance assessment (PA) and risk assessment practitioners, regulators and oversight personnel. The general intent is to contribute to continuous improvement in the consistency, technical adequacy and quality of implementation of PAs and risk assessments around the DOE Complex. The PA CoP activities have involved commercial disposal facilities and international participants to provide a global perspective. The PA CoP has also sponsored annual technical exchanges as a means to foster improved communication and to share lessons learned from on-going modelling activities. The PA CoP encourages activities to provide programmatic and technical assistance in the form of sharing experience and lessons learned with practitioners during the development of PAs and risk assessments. This assistance complements DOE-EM reviews through the Low-Level Waste Disposal Facility Federal Review Group (LFRG) that are conducted after modelling efforts are completed. Such up-front assistance is providing additional value in terms of improving consistency and sharing of information. There has been a substantial increase in the amount of assistance being provided. The assistance has been well received by practitioners and regulators that have been involved. The paper highlights assistance and sharing of information that has been conducted in the last two years to support activities underway in support of proposed disposal facilities at Paducah, Portsmouth, and the Idaho National Laboratory and tank closure at Hanford.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energy Factor Analysis for Gas Heat Pump Water Heaters

Gas heat pump water heaters (HPWHs) can improve water heating efficiency with zero GWP and zero ODP working fluids. The energy factor (EF) of a gas HPWH is sensitive to several factors. In this work, expressions are derived for EF of gas HPWHs, as a function of heat pump cycle COP, tank heat losses, burner efficiency, electrical draw, and effectiveness of supplemental heat exchangers. The expressions are used to investigate the sensitivity of EF to each parameter. EF is evaluated on a site energy basis (as used by the US DOE for rating water heater EF), and a primary energy-basis energy factor (PEF) is also defined and included. Typical ranges of values for the six parameters are given. For gas HPWHs, using typical ranges for component performance, EF will be 59 80% of the heat pump cycle thermal COP (for example, a COP of 1.60 may result in an EF of 0.94 1.28). Most of the reduction in COP is due to burner efficiency and tank heat losses. Gas-fired HPWHs are theoretically be capable of an EF of up to 1.7 (PEF of 1.6); while an EF of 1.1 1.3 (PEF of 1.0 1.1) is expected from an early market entry.

Gluesenkamp, Kyle R↗

Searching for eco-friendly working fluids for an ejector-driven heat pump for domestic water heating

This study searches for refrigerants with low global warming potential (GWP) and zero ozone depletion potential (ODP) for an ejector heat pump water heater (EHPWH). Several criteria are set, and R1336mzz(Z), R601a, R1233zd(E), R1224yd(Z), R1234ze(Z), and R600a are shortlisted. A theoretical model is built to study the performance of EHPWH and the corresponding ejector design at different operating conditions. For the same ejector design, a refrigerant with a high specific heat ratio produces a high entrainment ratio and heating COP. This is because the expansion wave angle in the ejector is small for refrigerants with a high specific heat ratio, allowing more mass flow rate to be entrained. A higher entrainment ratio does not necessarily correlate to a high COP because the saturation curve of the tested refrigerants is not the same. Results show that the heating COP of R601a is the highest, but it is extremely flammable. R1224yd(Z) and R1234ze(Z) are the most candidates for EHPWH when the trade-off between the COP and safety criteria is considered. The results presented in this work could help building an EHPWH using eco-friendly refrigerants.

Mohammed, Ramy H.↗

Experimental study of steam-driven ejector heat pump

Ejector-driven systems have been shown to be promising for heating applications. Most of the research works have been devoted to cooling purposes, while little attention has been focused on heating applications. An experimental steam ejector heat pump system (EHP) was designed and constructed to assess its applicability to water heating applications. The effect of the primary nozzle exit position (NXP) on the performance of the steam ejector system was investigated for primary nozzle throat diameter of 1.5 mm and 2.0 mm. The ejector system was run for high-temperature evaporator (HTE) temperatures of 120, 130, and 140 °C and low-temperature evaporator (LTE) temperatures of 10, 15, and 20 °C. The target of this investigation was to attain the highest condensing temperature to be able to use the proposed system for water heating purposes. The ejector heat pump coefficient of performance (EHP COP) was used to determine the system efficiency. Larger LTE temperatures were found to result in higher EHP COPs and condensing temperatures. A maximum EHP COP of 2.02 was attained for a HTE and LTE temperatures of 120 °C and 20 °C, respectively; however only resulted in a condensing temperature of 22.88 °C. Higher HTE temperatures were found to result in higher condensing temperatures but at the cost of EHP COP.

Spitzenberger, Jeremy↗

Experimental Investigation on Heating Performance of a Cold Climate Thermoelectric-Assisted Heat Pump

To accelerate the electrification of air source heat pumps (ASHPs) in cold climates across the United States, various initiatives have been launched to enhance the effectiveness of ASHPs. One avenue of research involves incorporating thermoelectric (TE) technology into vapor compression refrigeration cycles. This study aims to assess the heating performance of a cold climate ASHP by employing TE modules as a liquid line subcooler. The tested system is a nominal 4.5-ton split heat pump utilizing R410A, equipped with a scroll compressor and an accumulator. An electronic expansion valve was employed for both cooling and heating modes. Two configurations of TE sub-coolers, one utilizing 2 TE bundles and the other 4 TE bundles, were integrated into the liquid line of the tested system. The heating performance of these configurations was evaluated. The results revealed that activating the TE subcooler led to a notable increase in total heat capacity, reaching 1318 W at -15.0 °C and 1164 W at -19.0 °C. The corresponding TE coefficients of performance (COPs) were 1.76 and 1.63, respectively. The activation of the TE sub-cooler resulted in a slight reduction in the overall system COP, with a decrease ranging from -2.6% to -4.2% for these two temperatures. The system COPs were measured at 2.10 and 1.86 for -15.0 °C and -19.0 °C, respectively. This prototype demonstrated a significant augmentation in heating capacity with a minimal sacrifice in COP.

Hu, Yifeng↗

Development and evaluation of a multi-functional heat pump with embedded thermal storage

We developed and tested a novel multi-functional packaged vertical heat pump designed for multi-family buildings, capable of providing space cooling, space heating, water heating, and energy storage integration. The system employs a 3-speed scroll compressor and supports energy-efficient cooling and heating across different ambient conditions, while utilizing both indoor and outdoor air sources for water heating. Key performance metrics include an integrated energy efficiency ratio of 18.0 for cooling, a heating seasonal performance factor of 10.0, and a coefficient of performance (COP) of 2.1 for heating in cold climates down to −15 ˚C. Additionally, the system delivers an annual water heating COP greater than 4.0, with outstanding performance in combined space cooling and water heating modes, achieving a total COP of 8.8 by recovering condenser waste heat. The heat pump also demonstrated thermal energy storage capabilities, integrating with phase change material systems to store heating and cooling energy. Furthermore, this versatile system offers a promising solution for improving energy efficiency and sustainability in multi-family buildings, providing high-performance heating, cooling, and water heating across a range of climates.

COP↗

Final Scientific/Technical Report-FREE-piston Zero Emissions Refrigerator (FREEZER)

The FREE-piston Zero Emissions Refrigerator (FREEZER™) is a natural refrigerant Stirling-cycle cooler developed by AMSC in partnership with Heatcraft, targeted as a replacement refrigeration system for walk-in coolers or freezers found commonly in restaurants, convenience stores, supermarkets, etc. The FREEZER™, combined with a closed-loop CO2 heat-transfer system, had the goal to provides an efficient (Target COP = 1.4), zero ODP (Ozone Depletion Potential) and near zero GWP (Global Warming Potential) refrigeration solution with no synthetic, flammable, or toxic refrigerants. Other near zero GWP refrigeration systems do not exist at the scale and performance level of FREEZER. ARPA-E Continuation Funding enabled the design and fabrication of one Advanced Development Unit (ADU) cooler and two Field Test Unit (FTU) coolers, and a new revised Field Test Unit (new FTU). Heatcraft was to extensively test the various coolers at their facilities, which closely simulate real-world conditions. The original plan was to install and operate FREEZER FTUs alongside a traditional cooling solution at one or more customer locations to obtain data on direct performance comparisons with existing commercial refrigeration systems. Success in this FREEZER refinement and field-test project will establish the basis for a new class of environmentally friendly refrigeration systems that will revolutionize the industry. The hardware developed under the program is shown below in Figure 1. Five Stirling-cycle machines were built within the program, with a sixth cooler still under construction. The original DU and the ADU coolers met the performance target with a coefficient of performance (COP) of 1.2. The FTU was underperforming during the initial tuning of the free-piston Stirling cycle dynamics when there was a catastrophic failure of the fasteners on pressure boundary. This caused a pause to the program while the failure mechanism was investigated. The root cause was an inadequate flange design that allowed an excessive cyclic loading on the fasteners, leading to a fatigue failure. It was determined that existing FTU design could not be reasonably salvaged in a safe manner, and that fact, combined with the lower-than-expected performance of the new experimental heat exchanger modules lead to the design of the “new FTU” with a more conventional shell-and-tube heat exchanger design which should get close to the design target COP of 1.4, but have a higher overall machine cost. The program ran out of time before the fabrication of the new FTU was completed, but AMSC is still working on the cooler, with the majority of the parts fabricated, and hopes to have the unit under test sometime in early 2022, after which it will be shipped to Heatcraft for additional testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Roadmap to Cooperative Operating Practices for Strategic Conflict Detection and Resolution in the Upper Class-E Traffic Management Concept

As the governing body of flight operations in the highly anticipated emergent area of Upper Class E airspace (60,000 ft and above), the Federal Aviation Administration (FAA) has recognized the potential for a possible extensible traffic management system for new entrants into this domain. Following the successes with Unmanned Aircraft Systems (UAS) Traffic Management (UTM) and Advanced / Urban Air Mobility (AAM / UAM) Traffic Management programs, FAA put forth an initial concept of operations for supporting the start of the Upper Class E Traffic Management (ETM) concept. Like UTM and AAM / UAM, ETM is envisioned to also be a community-based, industry driven cooperative management concept. However, tailoring it to be adaptable to the atmospheric communication, navigation, and surveillance deficits, as well as the diverse vehicle and mission profiles operating in the ETM environment will be the challenge. As such, the National Aeronautics and Space Administration (NASA) Ames Research Center has been investigating several technologies that will help enable industry in the development of this new type of cooperative operating environment. These technologies are being prototyped and will be tested in a collaborative evaluation of an initial ETM system in late 2023. The evaluation will concentrate on building out ETM system technologies that will inform the participants regarding operational intent sharing, strategic conflict detection, and the resultant deconfliction process. In addition to the technical aspects, key roles and responsibilities will need to be defined. This will be done through exploring community-agreed upon Cooperative Operating Practices (COPs) that include procedures and capabilities to aid in timely, strategic conflict identification and resolution to be developed during the evaluation. As an initial step to the evaluation, the ETM research team at NASA Ames solicited industry feedback on various aspects of ETM operations from subject matter experts. A virtual tabletop walkthrough session was held over a two-day period to follow a roadmap through the functional steps needed to build COPs, focusing on strategic conflict detection and resolution. Overall, the ETM tabletop provided insights into how the community wanted to instantiate the generation and sharing of operational intent, detect strategic conflicts and resolve those conflicts using a preliminary set of procedural community-agreed upon COPs.

Upper Class-E Traffic Management (ETM)↗

Structures of a synthetic antibody selected against and bound to the C‐terminal domain of Clostridium perfringens enterotoxin

Abstract Clostridium perfringensenterotoxin (CpE) causes cytotoxic gastrointestinal disease in mammalian epithelium by binding membrane protein receptors called claudins. Claudins direct the formation of cell/cell tight junctions through oligomerization and govern the transport of molecules between individual cells. CpE binds claudins through its C‐terminal domain (cCpE) and induces cytotoxicity through its N‐terminal domain. The non‐toxic cCpE is a useful tool to study claudins, tight junctions, and for translational applications, such as increasing the permeability of restrictive tissues like the blood–brain barrier or selective targeting of claudin overexpressing cancers. Conversely, there are no specialized molecular tools to study CpE or cCpE, or to modulate or inhibit their functions. We previously reported the development of synthetic antigen‐binding fragments (sFabs) that bind cCpE, and low‐resolution structures of them bound to claudin/cCpE complexes. Here, we determine high‐resolution structures of sFab COP‐2 bound to cCpE using X‐ray crystallography and cryogenic electron microscopy. The structures and biophysical findings provide the mechanism of COP‐2 binding to cCpE and the molecular determinants driving their interactions. These insights can advance the design of new antibody‐based tools from our COP‐2 scaffold to study or alter cCpE function and give rise to a “Trojan horse” strategy that exploits cCpE's tight junction barrier disrupting function to selectively deliver conjugated therapeutics through normally impermeable tissues.

Biochemistry & Molecular Biology↗

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗

Thermal performance of an absorption-assisted two-stage ejector air-to-water heat pump

In this work, a gas-fired air-to-water ejector heat pump (EHP) for domestic hot water production is proposed and analyzed thermodynamically. The COP of the EHP is improved by using binary fluids (HFE7500 and water), and the high backpressure in the primary ejector (first-stage) is actively controlled by either a second-stage ejector and/or a LiBr-H 2 O absorption subsystem. A thermodynamic model is established for analysis and performance evaluation. A case study shows the backpressure of the first-stage ejector is reduced by 53.5%, and the backpressure control using the second-stage ejector increases the system COP by 21.0% compared with that using LiBr-H 2 O absorption. Parametric studies are conducted to investigate the roles of the first-stage ejector, the second-stage ejector, and the LiBr-H 2 O absorption subsystem. The first-stage ejector plays a dominant role in the EHP system performance. The EHP’s heating COP can reach 2.0 with an entrainment ratio of 0.12 in the first-stage ejector. EHP performance can be improved with a high entrainment ratio and a low-temperature primary working fluid in the first-stage and second-stage ejectors, a low condensation temperature in the first-stage ejector, and a high generating temperature and a low concentration of the LiBr-H 2 O solution.

30 DIRECT ENERGY CONVERSION↗

A first and second law analysis of a thermoresponsive polymer desiccant dehumidification and cooling cycle

Herein, we present a theoretical description for a new desiccant air conditioning cycle that uses thermoresponsive polymers instead of traditional desiccants. We use a combined first and second law analysis to demonstrate that this new cycle has three major advantages relative to the traditional case: (i) it can regenerate at lower temperatures, (ii) it can harvest liquid water and (iii) it has significantly higher coefficients of performance (COPs). For example, this new cycle can achieve a COP of 5.1 when regenerated at 95 degrees C, whereas the traditional desiccant cycle is limited to a COP of ~ 1. The fundamental origins of these advantages can be traced to the method of regeneration. The traditional desiccant cycle regenerates by flowing hot air over the desiccant, which provides a medium for gaseous water desorption. However, this also generates entropy and places a minimum temperature constraint on the hot air. In contrast, the thermoresponsive polymer cycle regenerates through a polymer phase transition. The polymer absorbs water vapor in humid air, and then it expels liquid water when raised above its transition temperature. This regeneration method generates liquid water that can be harvested and relaxes constraints on entropy generation and minimum temperature. The minimum regeneration temperature of the thermoresponsive cycle is only limited by the transition temperature of the polymer, which can be tuned through materials science. Due to its liquid water harvesting capability, the new cycle potentially eliminates water consumption when used with evaporative cooling, or it can be directly used for atmospheric water harvesting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Micromovements and discomfort associated with flight mission with helmet operation tasks with different levels of cognitive workload

When performing stationary tasks under elevated cognitive workload, individuals must perform continual muscle contractions to maintain stability of the body, resulting in fatigue of the postural muscles. When the muscles perform these contractions in a prolonged manner, the body potentially responds through small changes in body movements—micromovements that may lead to discomfort. The study purpose was to evaluate impact of cognitive load on micromovements. The micromovements were measured during three different cognitive workloads; low, medium, and high. The NASA-TLX score was used to evaluate the perceived mental workload and discomfort was assessed by visual analog scale. In total, 60 subjects (30 males and 30 females) were recruited and performed cognitive tasks that simulated flight operations such as changing the radio frequency based on air traffic control messages, balancing the fuel levels in simulated fuel tanks, and aiming a reticle in a designated moving target using the cyclic control. Cognitive load was defined by the frequency of events. Micromovements were defined by changes in the center of pressure (COP) of the seat pan and COP standard deviation. It was found that the high cognitive workloads had the highest NASA-TLX scores including mental demands, temporal demands, and effort. The neck area had the highest overall levels of discomfort followed by upper back. The highest standard deviation for COP shift and number of micromovements occurred for medium cognitive workloads. In conclusion, while there were some interesting trends, few trends reached a statistical significance due to high variability among subjects for the outcome variables.

60 APPLIED LIFE SCIENCES↗

Exergy analysis and operational efficiency of a horizontal ground-source heat pump system operated in a low-energy test house simulated occupancy conditions

This paper presents detailed analysis of a water to water ground source heat pump (WW-GSHP) to provide all the hot water needs in a 345 m 2 house located in DOE climate zone 4 (mixed-humid). The protocol for hot water use is based on the Building America Research Benchmark Definition (Hendron 2008; Hendron and Engebrecht 2010) which aims to capture the living habits of the average American household and its impact on energy consumption. The entire house was operated under simulated occupancy conditions. Detailed energy and exergy analysis provides a complete set of information on system efficiency and sources of irreversibility, the main cause of wasted energy. The WW-GSHP was sized at 5.275 kW (1.5-ton) for this house and supplied hot water to a 303 L (80 gal) water storage tank. The WW-GSHP shared the same ground loop with a 7.56 kW (2.1-ton) water to air ground source heat pump (WA-GSHP) which provided space conditioning needs to the entire house. Data, analyses, and measures of performance for the WW-GSHP in this paper complements the results of the WA-GSHP published in this journal (Ally, Munk et al. 2012). Understanding the performance of GSHPs is vital if the ground is to be used as a viable renewable energy resource.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling of hydrogen liquefaction using magnetocaloric cycles with permanent magnets

Hydrogen (H 2 ) is promising alternative to replace fossil fuels, but its transport and storage has been challenging. As H 2 fuel cell vehicles are gaining traction, the infrastructure for storing large amounts of liquid H 2 is needed. However, liquid H 2 would suffer from boil-off loss, and traditional vapor compression refrigeration systems would not be able to economically recover the lost H 2 due to the low efficiencies at cryogenic temperature. Magnetocaloric (MC) refrigeration systems could possess much higher coefficient of performance (COP) at cryogenic temperature compared to the vapor compression ones. Previous work on cryogenic MC systems, however, have only focused on large scale applications which use superconducting magnets to provide a large magnetic field but are prohibitively expensive to operate for small scale applications, such as that of a H 2 refilling station. In this work, we model the performance of a MC refrigeration cycle using 1-Tesla permanent magnets for H 2 liquefaction, with the objective of cooling H 2 from 80 K (using liquid nitrogen as the heat sink) to 20 K (boiling point of hydrogen). We evaluate main performance metrics including the total work input to the refrigeration system, COP, total MCM mass in the system, and total volume of the permanent magnets, etc. Our modeling results indicate that such a permanent magnet-based MC cooling system is feasible for small-scale H 2 liquefaction, with projected COP values significantly higher than those of vapor compression systems. In conclusion, this work provides design guidelines for future experimental efforts on permanent magnet MC cooling systems for cryogenic cooling.

08 HYDROGEN↗