Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cherenkov detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Measuring the neutrino-oxygen neutral current quasielastic cross section using the accelerator neutrino neutron interaction experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-doped water Cherenkov detector located on-axis to Fermilab’s Booster Neutrino Beam (BNB). ANNIE is uniquely positioned to perform high-statistics measurements of neutrino-nucleus interactions in water, benefiting from a large neutrino flux due to a short (100-meter) baseline. A central focus of ANNIE’s physics program is the measurement of both charged current (CC) and neutral current (NC) cross sections on water, including neutral current quasielastic (NCQE) and CC-inclusive channels. The NCQE measurement is particularly critical for constraining uncertainties in rare-event searches such as the Diffuse Supernova Neutrino Background (DSNB), where atmospheric $\nu$NCQE interactions constitute a significant and poorly constrained background. This dissertation presents a measurement of the flux-averaged neutrino-oxygen neutral current quasielastic ($\nu$NCQE) cross section using $2.573 \times 10^{20}$~POT of BNB exposure from the 2022 and 2023 beam years. The $\nu$NCQE interaction is identified through the primary $\gamma$-rays produced by nuclear de-excitation of the residual $^{15}$N$^*$ or $^{15}$O$^*$ nucleus following nucleon knockout from $^{16}$O. A dedicated Monte Carlo (MC) re-tuning campaign was conducted using an americium-beryllium (AmBe) calibration source, Michel electrons from stopped muons, and throughgoing dirt muons originating upstream of the detector. This multi-sample approach provided a wide-ranging $\mathcal{O}(\text{MeV})$--$\mathcal{O}(\text{GeV})$ dataset for tuning the simulated detector response, which was subsequently validated against AmBe neutron and Michel electron data for use in the $\nu$NCQE analysis. A dedicated laser calibration campaign was carried out to reduce timing uncertainties across the PMT system, enabling reconstruction of the BNB bunch substructure with sufficient resolution to serve as a background rejection tool. By selecting events in-time with individual neutrino bunches, beam-correlated $\nu$NCQE events are separated from diffuse and accelerator-induced backgrounds, notably skyshine neutrons and externally-originating events, that would otherwise dominate traditional charge-based selections within a small-scale, surface-level, short-baseline detector. A data-driven estimation of the skyshine neutron and external background rates was performed and incorporated into the systematic uncertainty budget. The flux-averaged $\nu$NCQE cross section on oxygen is measured to be $1.57 \pm 0.06\,(\text{stat.})$ $^{+0.91}_{-0.67}\,(\text{syst.})$ $\times 10^{-38}\ \text{cm}^{2}$. A full systematic budget is constructed by propagating uncertainties in the secondary hadronic interaction modeling, background cross section normalizations, detector response, neutrino flux, and the primary $\gamma$-ray emission probabilities from oxygen nuclear de-excitation. An idealized de-excitation model, constructed from existing measurements in the literature is developed to benchmark the predictions of the \textsc{GENIE} event generator. A comparison reveals that \textsc{GENIE} systematically overpredicts the primary $\gamma$-ray emission probability from oxygen de-excitation by a factor of $1.49\times$ for $E_\gamma > 6$~MeV and $3.07\times$ in the $3$--$6$~MeV band. This comparison motivates the dominant systematic uncertainty in this analysis, where a conservative uncertainty of $^{+39.9\%}_{-0\%}$ on the primary $\gamma$-ray signal prediction is assigned. The ANNIE result is consistent with and complementary to existing flux-averaged $\nu$NCQE cross section measurements from T2K and Super-Kamiokande, providing an independent measurement with a different detector, neutrino beam, and analysis methodology. Looking ahead, an upgrade to the ANNIE DAQ infrastructure enabling continuous extended readout will allow a complementary $\nu$NCQE neutron multiplicity measurement, directly relevant to constraining the NCQE background in DSNB searches, competitive with the recent T2K measurement at SK-Gd. The planned Super-SANDI upgrade, deploying a large Water-based Liquid Scintillator (WbLS) volume, will further extend ANNIE's reach to hadronic final states and exclusive NC channels, and enable joint measurements with liquid argon detectors sharing the BNB beamline ahead of DUNE and Hyper-Kamiokande.

Doran, Steven [Iowa State U.]↗

Integration and performance of large area picosecond photodetectors in the accelerator neutrino neutron interaction experiment

ANNIE, the Accelerator Neutrino Neutron Interaction Experiment, is a 26-ton Gadolinium-loaded water Cherenkov detector located at the Booster Neutrino beam line at Fermilab to mainly measure neutron multiplicity of neutrino interactions and test the performance of Large Area Picosecond Photodetectors (LAPPD). This thesis presents the integration of LAPPD at ANNIE and the preliminary performance analysis. LAPPDs achieved 2.48ns bunch structure resolution, even considering the time of flight and the intrinsic bunch width. The analysis also achieves better than 100ps intrinsic timing resolution, sub-mm position resolution for a single photoelectron, and cm-level resolution in conditional muon track reconstruction.

Feng, Yue [Iowa State U.] (ORCID:0000000332021351)↗

Measuring Charged Current Muon Neutrino Cross Sections on Oxygen with the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a $26$-ton gadolinium-doped water Cherenkov detector on-axis of the Booster Neutrino Beam (BNB) at Fermilab. With ANNIE, this dissertation provides the first results of a high statistics muon neutrino charged current cross section on oxygen at a short baseline on axis. This thesis explains the necessity of the measurements and details how the measurements are performed. Focus is given on the physics behind the models used to predict neutrino cross sections. The measurements include the CC inclusive and CC$0\pi$ cross section channels. This thesis details the processes of event selection, reconstruction, handling systematics, and unfolding as part of cross section measurements. A data unblinding procedure is documented and acts as the first implementation of data unblinding in ANNIE. These results provide additional constraints on existing neutrino interaction models and are the necessary steps for a joint analysis with liquid Argon experiments also on the BNB line.

Minock, James [Rutgers U., Piscataway (main)]↗

Low power implementation of high frequency SiPM readout for Cherenkov and scintillation detectors in TOF-PET

State-of-the-art (SoA) electronic readout for silicon photomultiplier (SiPM)-based scintillation detectors that demonstrate experimental limits in achievable coincidence time resolution (CTR) leverage low noise, high frequency signal processing to facilitate a single photon time response that is near the limit of the SiPMs architecture. This readout strategy can optimally exploit fast luminescence and prompt photon populations, and promising measurements show detector concepts employing this readout can greatly advance PET detector CTR, relative to SoA in clinical systems. However, the technique employs power hungry components which make the electronics chain impractical for channel-dense time-of-flight (TOF)-PET detectors. We have developed and tested a low noise and high frequency readout circuit which is performant at low power and consists of discrete elements with small footprints, making it feasible for integration into TOF-PET detector prototypes. A 3 × 3 mm 2 Broadcom SiPM with this readout chain exhibited sub-100 ps single photon time resolution at 10 mW of power consumption, with a relatively minor performance degradation to 120 ± 2 ps FWHM at 5 mW. CTR measurements with 3 × 3 × 20 mm 3 LYSO and fast LGSO scintillators demonstrated 127 ± 3 ps and 113 ± 2 ps FWHM at optimal power operation and 133 ± 2 ps and 121 ± 3 ps CTR at 5 mW. BGO crystals 3 × 3 × 20 mm 3 in size show 271 ± 5 ps FWHM CTR (1174 ± 14 ps full-width-at-tenth-maximum (FWTM)) at optimal power dissipation and 289 ± 8 ps (1296 ± 33 ps FWTM) at 5 mW. The compact and low power readout topology that achieves this performance thereby offers a platform to greatly advance PET system CTR and also opportunities to provide high performance TOF-PET at reduced material cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The scintillator surface detector of the Pierre Auger observatory

Data collected so far by the Pierre Auger Observatory have enabled major advances in ultra-high energy cosmic ray physics and demonstrated that improved determination of masses of primary cosmic-ray particles, preferably on an event-by-event basis, is necessary for understanding their origin and nature. Improvement in primary mass measurements was the main motivation for the upgrade of the Pierre Auger Observatory, called AugerPrime. As part of this upgrade, scintillator detectors are added to the existing water-Cherenkov surface detector stations. By making use of the differences in detector response to the electromagnetic particles and muons between scintillator and water-Cherenkov detectors, the electromagnetic and muonic components of cosmic-ray air showers can be disentangled. Since the muonic component is sensitive to the primary mass, such combination of detectors provides a powerful way to improve primary mass composition measurements over the original Auger surface detector design. In this paper, the so-called Scintillator Surface Detectors are discussed, including their design characteristics, production process, testing procedure and deployment in the field.

Detector design and construction technologies and ↗

The ePIC dual-radiator RICH detector

The dual radiator Ring Imaging Cherenkov (dRICH) detector is required to provide continuous hadron identification from ≈3 GeV/c up to ≈50 GeV/c, and to supplement electron and positron identification from a few hundred MeV/c up to about 15 GeV/c, in the forward (ion-side) end-cap of the ePIC experiment. Such an extended momentum range imposes the use of two radiators, gas and aerogel. The common imaging system, that ensures compactness and cost-effectiveness, is based on SiPM sensors to work in a high non-uniform magnetic field. During the R&D phase, the dual radiator principle and the single component performance have been validated. A status overview of the project is presented. The design and technological choices are discussed together with the results obtained from laboratory characterization of the component demonstrators and beam tests of the evolving prototypes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deployment of Water-based Liquid Scintillator in the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton water Cherenkov neutrino detector installed on the Booster Neutrino Beam (BNB) at Fermilab. Its main physics goals are to perform a measurement of the neutron yield from neutrino-nucleus interactions, as well as a measurement of the charged-current cross section of muon neutrinos. An equally important focus is the research and development of new detector technologies and target media. Specifically, water-based liquid scintillator (WbLS) is of interest as a novel detector medium, as it allows for the simultaneous detection of Cherenkov light and scintillation. This paper presents the deployment of a 366 L WbLS vessel in ANNIE in March 2023 and the subsequent detection of both Cherenkov light and scintillation from the WbLS. Finally, this proof-of-concept allows for the future development of reconstruction and particle identification algorithms in ANNIE, as well as dedicated analyses within the WbLS volume, such as the search for neutral-current events and the hadronic scintillation component.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AI-optimized detector design for the future Electron-Ion Collider: the dual-radiator RICH case

Advanced detector R&D requires performing computationally intensive and detailed simulations as part of the detector-design optimization process. Here, we propose a general approach to this process based on Bayesian optimization and machine learning that encodes detector requirements. As a case study, we focus on the design of the dual-radiator Ring Imaging Cherenkov (dRICH) detector under development as a potential component of the particle-identification system at the future Electron-Ion Collider (EIC). The EIC is a US-led frontier accelerator project for nuclear physics, which has been proposed to further explore the structure and interactions of nuclear matter at the scale of sea quarks and gluons. We show that the detector design obtained with our automated and highly parallelized framework outperforms the baseline dRICH design within the assumptions of the current model. Our technique can be applied to any detector R&D, provided that realistic simulations are available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Plutonium Mass Uncertainty Assessment Using a Cherenkov-Based Neutron Multiplicity Water Detector

We present a new analysis of the sensitivity of a water Cherenkov-based neutron multiplicity counter for nondestructive assay of trace quantities of 240 Pu. The multiplicity counter [water-based neutron detector (WaND)] contains 1.0 m 3 of water doped with 0.2% gadolinium in the form of a gadolinium salt (0.4% GdCl 3 ). It can be used for testing the presence of trace quantities of 240 Pu within a sample of unknown material by observing the correlated timing behavior of neutron capture candidates in the detector. The new analysis takes advantage of the fact that the detector is comprised almost entirely of a homogeneous medium, which permits the use of a simple model to reproduce the observed neutron capture timing behavior. Finally, the results of this analysis indicate that the detector has an absolute neutron detection efficiency of 23.4 ± 1.1% and is sensitive to a 240 Pu mass as small as 2.3 mg (at 1σ) after a 1-h data acquisition.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Novel Instrumentation for Advanced Quantum Chromodynamics Studies with Flavor Sensitivity

The true nature of ordinary matter has always fascinated humankind, whose imagination has been pointed to the right direction since the 5th century BC with the first known atomic theory by Leucippus and Democritus. They described the matter as formed by small, invisible, indivisible, and eternal particles: the atoms. A long investigation followed them, including contributions from several of history?s greatest philosophers and scientists. The progress led to the understanding that atoms have an internal structure consisting of a central nucleus composed of protons and neutrons, surrounded by a cloud of electrons. About 50 years ago, scientists discovered that nucleons also have an internal structure. Through the Deep Inelastic Scattering (DIS) experiments, on which a lepton is scattered off a nucleon, it was possible to access the distribution of partons inside the nucleon along the longitudinal direction defined by the hard-scale probe. It was a crucial step in developing Quantum Chromodynamics (QCD), currently the best theory describing the subatomic matter. Ultimately, DIS was recognized as a limited tool to investigate the nucleon structure because it is mainly sensitive to observables at the probe?s energy scale. In recent decades, theoretical developments have allowed defining soft-scale observables by measuring more complex processes. Reactions such as Semi-Inclusive Deep Inelastic Scattering (SIDIS) with single or di-hadron production, can provide information about the momentum of parton inside the nucleon. In particular, polarized SIDIS allows access to the Transverse-Momentum-Dependent (TMD) parton distributions describing the correlations of the quark and gluon degrees of freedom in transverse momentum and spin. This study can provide three-dimensional imaging of nucleon structure and inner dynamics, as long as the hadronic component in the final state can be measured. Identifying the species of the produced particles provides information on the quark flavor and assumes a crucial role in this context. The thesis describes the work carried out by the author in preparing novel instrumentation for particle identification in the final state of DIS experiments, to support modern analysis of the parton dynamics within the basic confined object (nucleon) with flavor sensitivity. The work has been focused on the CLAS12 spectrometer in operation at Jefferson Laboratory (JLab), Newport News, VA, USA, and the ePIC experiment in preparation for the future Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL), Long Island, NY, USA. CLAS12 is a fixed-target experiment using a 12 GeV beam of polarized electrons scattering off polarized nuclear targets. In 2018 and 2022, two Ring Imaging Cherenkov (RICH) detector modules were installed to improve the ?±/K± separation in the high-momentum region (3÷8 GeV/c) of the experiment. The author contributed to the assembly, installation, and com- missioning of the second RICH module, to the efficiency studies of the first module, and to the first SIDIS analysis with high-momentum kaons identified by the RICH. These studies led to the observation of the first spin asymmetry with high-momentum kaons from the CLAS12 experiment, and an initial assessment of the systematic error associated with the hadron identification. ePIC will be the first experiment at the future EIC, the new collider designed to expand the frontiers of QCD. The author was involved in the development of the dual-radiator Ring Imaging Cherenkov (dRICH). This detector will interpolate the measurements of the Cherenkov angles of photons produced by relativistic particles crossing two different radiators to identify charged hadrons. The author contributed to the studies conducted with the dRICH prototype, developing the reconstruction and analysis software and simulations, characterizing the aerogel radiator samples, and being responsible for the tracking system used during the beam tests. The performance obtained by the prototype has been progressively improved and the results are now comparable with the expectation derived from the simulation and satisfy the requirements of the experiment. In Chapter 1, the SIDIS theory is briefly introduced, outlying the connection with the experimental measurement. Chapter 2 includes the description of the CLAS12 RICH, its assembly and installation, and the efficiency study. In Chapter 3, the analysis of the Beam-Spin Asymmetry associated with SIDIS kaons is described. Chapter 4 describes the contribution to the dRICH for EIC, starting from a description of the ePIC experiment and focusing on the studies performed for the dRICH prototype. The conclusions of this work are summarized at the end.

Vallarino, Simone↗

Scalable DAQ system operating the CHIPS-5 neutrino detector

The CHIPS R&D project focuses on development of low-cost water Cherenkov neutrino detectors through novel design strategies and resourceful engineering. This work presents an end-to-end DAQ solution intended for a recent 5 kt CHIPS prototype, which is largely based on affordable mass-produced components. Much like the detector itself, the presented instrumentation is composed of modular arrays that can be scaled up and easily serviced. A single such array can carry up to 30 photomultiplier tubes (PMTs) accompanied by electronics that generate high voltage in-situ and deliver time resolution of up to 0.69 ns. In addition, the technology is compatible with the White Rabbit timing system, which can synchronize its elements to within 100 ps. While deployment issues did not permit the presented DAQ system to operate beyond initial evaluation, the presented hardware and software successfully passed numerous commissioning tests that demonstrated their viability for use in a large-scale neutrino detector, instrumented with thousands of PMTs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the absolute single-photon detection efficiency of HRPPD

Pixelated High Rate Picosecond Photon Detectors (HRPPDs) by Incom Inc. are promising photosensors for use in Ring Imaging CHerenkov (RICH) detectors, where a high gain, sub-mm position resolution and sub-100ps timing resolution are required in a single photon mode. Quantum Efficiency (QE) has been measured for the first batch of EIC HRPPDs both by Incom and EIC research groups at Jefferson Lab and Brookhaven Lab, with peak values at ∼365 nm typically exceeding 30%. Furthermore, in this study, we present a first direct measurement of Photon Detection Efficiency being equal to (17.1 ± 0.1 [stat] ± 0.3 [sys])% at 398.6 nm, for a pixel near the center of HRPPD, in a photoelectron pulse counting mode using a picosecond diode laser. HRPPD QE at the same spot and at the same wavelength was evaluated to be (24.4 ± 0.1 [stat] ± 0.3 [sys])%, leading to a Collection Efficiency estimate of (70.3 ± 1.6)%, which is consistent with the expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MCP-PMT development at Argonne for particle identification

The proposed high-energy high-luminosity polarized Electron-Ion Collider (EIC) demands excellent particle identification over a wide range of particles momenta to achieve the best separation between signal and background particles. Various Cherenkov imaging detector sub-systems are being considered in EIC detector concepts for hadron identification for particles momenta up to 50 GeV/c. One important challenge in this case is to provide a reliable highly pixelated photosensor working in the high radiation and high magnetic field environment. The recently commercialized Large Area Picosecond Photo-Detector (LAPPD) provides a promising low-cost photosensor solution for the various EIC Cherenkov imaging sub-systems. Optimization of the phtosensor design for high magnetic field tolerance, precision timing resolution, and pixelated readout was performed at Argonne National Laboratory with 6 x 6 cm(2) microchannel plate photomultipliers. The techniques and optimized design parameters would be transferrable to industrial partners for low-cost LAPPD production to achieve the demonstrated performance.

atomic layer deposition↗

Nucleon Decays into Light New Particles in Neutrino Detectors

Proton and neutron decays into light new particles 𝑋 can drastically change the experimental signatures and benefit from the complementarity of large water-Cherenkov neutrino detectors such as Super- and Hyper-Kamiokande and tracking detectors such as JUNO and DUNE. The proton decays 𝑝 → ℓ + ⁢𝑋 and 𝑝 → 𝜋 + ⁢𝑋 with 𝑚 𝑋 near phase-space closure lead to charged particles below the Cherenkov threshold, rendering them practically invisible in Super- and Hyper-Kamiokande but not in JUNO and DUNE, which are therefore uniquely positioned for these baryon-number-violating signatures despite their smaller size. As an additional signature, such nucleon decays in the Earth can produce a sizable flux of 𝑋 particles in underground detectors. We present a simple model in which nucleons decay into sub-GeV sterile neutrinos that subsequently decay through active-sterile neutrino mixing, with a promisingly large number of events in Super-Kamiokande even in the seesaw-motivated parameter space.

Baryon & lepton number symmetries↗

Acceptance tests of Hamamatsu R7081 photomultiplier tubes

Photomultiplier tubes (PMTs) are traditionally an integral part of large underground experiments as they measure the light emission from particle interactions within the enclosed detection media. The BUTTON experiment will utilise around 100 PMTs to measure the response of different media suitable for rare event searches. A subset of low-radioactivity 10-inch Hamamatsu R7081 PMTs were tested, characterised, and compared to manufacture certification. This manuscript describes the laboratory tests and analysis of gain, peak-to-valley ratio and dark rate of the PMTs to give an understanding of the charge response, signal-to-noise ratio and dark noise background as an acceptance test of the suitability of these PMTs for water-based detectors. Following the evaluation of these tests, the PMT performance agreed with the manufacturer specifications. These results are imperative for modeling the PMT response in detector simulations and providing confidence in the performance of the devices once installed in the detector underground.

neutrino detectors↗

EAS Optical Cherenkov Signatures of Tau Neutrinos for Space and Suborbital Detectors

Multi-messenger observations of transient astrophysical sources have the potential to characterize the highest energy accelerators and the most extreme environments in the Universe. Detection of neutrinos, in particular tau neutrinos generated by neutrino oscillations in transit from their sources to Earth, is possible for neutrino energies above 10 PeV using optical Cherenkov detectors imaging upward-moving extensive air showers (EAS). These EAS are produced from Earth-interacting tau neutrinos leading to tau leptons that subsequently decay in the atmosphere. We compare neutrino detection sensitivities for generic short- and long-burst transient neutrino sources and sensitivities to the diffuse neutrino flux for the second generation Extreme Universe Space Observatory on a Super-Pressure Balloon (EUSO-SPB2) balloon-borne mission and the proposed space-based Probe of Extreme Multi-Messenger Astrophysics (POEMMA) mission.

Mary Hall Reno↗