Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cherenkov”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Towards robust PICOSEC Micromegas precise timing detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel PICOSEC MM prototype with 10 × 10 cm 2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below σ = 18 ps. The objective of this work is to improve the PICOSEC MM detector robustness aspects, i.e. integration of resistive MM and carbon-based photocathodes, while maintaining good time resolution. The PICOSEC MM prototypes have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon beams at the CERN SPS H4 beam line. The excellent timing performance below σ = 20 ps for an individual pad obtained with the 10 × 10 cm 2 area resistive PICOSEC MM of 20 MΩ/$\square$ showed no significant time resolution degradation as a result of adding a resistive layer. A single-pad prototype equipped with a 12 nm thick Boron Carbide (B 4 C) photocathode presented a time resolution below σ = 35 ps, opening up new possibilities for detectors with robust photocathodes. The results made the concept more suitable for the experiments in need of robust detectors with good time resolution.

RETHGEM↗

Reconstruction of neutrino events in the Accelerator Neutrino Neutron Interaction Experiment. Part I

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) was designed to reconstruct neutrino events from the Fermilab Booster Neutrino Beam (BNB) with the parallel goals of measuring neutron production in interactions with oxygen and serving as a testbed for new technology. The ANNIE detector consists of a 26-ton water Cherenkov target tank instrumented with conventional photomultiplier tubes (PMTs), a downstream tracking muon spectrometer, and an upstream double wall of plastic scintillator to serve to veto charged particles incoming from neutrino events that occur upstream of the experimental setup. ANNIE has also deployed multiple Large-Area Picosecond PhotoDetectors (LAPPDs) and a test vessel of water-based liquid scintillator (WbLS). This paper describes the event reconstruction performance of the detector before implementation of these novel technologies, which will serve as a baseline against which their impact can be measured. That said, even the techniques used for event reconstruction using only the conventional PMT array and muon spectrometer are significantly different than those used in other water Cherenkov detectors due to the small size of ANNIE (which makes nanosecond-scale timing not as useful as in a large detector) and the availability of reconstruction information from the tracking muon spectrometer. We demonstrate that combining the information from these two elements into a single fit using only pattern recognition yields a muon vertex uncertainty of 60 cm, a directional uncertainty of 13.2 degrees, and energy reconstruction uncertainty of about 10% for BNB muon neutrino Charged Current Zero Pion (CC0π) events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the liquid argon scintillation pulse shape using differentiable simulation in the coherent CAPTAIN-Mills experiment

The coherent CAPTAIN-Mills (CCM) experiment is a liquid argon (LAr) light collection detector searching for MeV-scale neutrino and beyond Standard Model physics signatures. Two hundred eight-inch photomultiplier tubes instrument the seven-ton fiducial volume with 50% photocathode coverage to detect light produced by charged particles. CCM’s light-based approach reduces requirements of LAr purity, compared to other detection technologies, such that sub-MeV particles can be reliably detected without additional LAr filtration and with 𝒪⁡(1) parts per million of common contaminants. We present a measurement of LAr light production and propagation parameters, with uncertainties, obtained from a sample of MeV-scale electromagnetic events. The optimization of this high-dimensional parameter space was facilitated by a differentiable optical photon Monte Carlo simulation and detailed photomultiplier tube response characterization. This result accurately predicts the timing and spatial distribution of light due to scintillation and Cherenkov emission in the detector. This is the first description of photon propagation in LAr to include several effects, including anomalous dispersion of the index of refraction near the ultraviolet resonance, Mie scattering from impurities, and Cherenkov light production.

Cherenkov detectors↗

Measurement of neutron-proton capture in the $\mathrmSNO+ water phase

The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV γ 's produced by neutron capture on hydrogen were made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV γ. Analysis of the delayed coincidence between the 4.4-MeV γ and the 2.2-MeV capture γ revealed a neutron detection efficiency that is centered around 50% and varies at the level of 1% across the inner region of the detector, which to our knowledge is the highest efficiency achieved among pure water Cherenkov detectors. Finally, in addition, the neutron capture time constant was measured and converted to a thermal neutron-proton capture cross section of $336.3^{+1.2}_{-1.5}$ mb .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evidence of Antineutrinos from Distant Reactors Using Pure Water at SNO+

The SNO+ Collaboration reports the first evidence of reactor antineutrinos in a Cherenkov detector. The nearest nuclear reactors are located 240 km away in Ontario, Canada. Here, this analysis uses events with energies lower than in any previous analysis with a large water Cherenkov detector. Two analytical methods are used to distinguish reactor antineutrinos from background events in 190 days of data and yield consistent evidence for antineutrinos with a combined significance of 3.5 σ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of the Crab Nebula with the 9.7 m prototype Schwarzschild-Couder telescope

The Schwarzschild-Couder Telescope (SCT) is a telescope concept proposed for the Cherenkov Telescope Array. It employs a dual-mirror optical design to remove comatic aberrations over an 8° field of view, and a high-density silicon photomultiplier camera (with a pixel resolution of 4 arcmin) to record Cherenkov emission from cosmic ray and gamma-ray initiated particle cascades in the atmosphere. Additionally, the prototype SCT (pSCT), comprising a 9.7 m diameter primary mirror and a partially instrumented camera with 1536 pixels, has been constructed at the Fred Lawrence Whipple Observatory. The telescope was inaugurated in January 2019, with commissioning continuing throughout 2019. We describe the first campaign of observations with the pSCT, conducted in January and February of 2020, and demonstrate the detection of gamma-ray emission from the Crab Nebula with a statistical significance of 8.6σ.

79 ASTRONOMY AND ASTROPHYSICS↗

Atmospheric pion, kaon, and muon fluxes for sub-orbital experiments

Cosmic rays interacting with the Earth's atmosphere generate extensive air showers, which produce Cherenkov, fluorescence and radio emissions. These emissions are key signatures for detection by ground-based, sub-orbital, and satellite-based telescopes aiming to study high energy cosmic ray and neutrino events. However, detectors operating at ground and balloon altitudes are also exposed to a background of atmospheric charged particles, primarily pions, kaons, and muons, that can mimic or obscure the signals from astrophysical sources. In this work, we use coupled cascade equations to calculate the atmospheric pion, kaon and muon fluxes reaching detectors at various altitudes. Our analysis focuses on energies above 10 GeV, where the influence of the Earth's magnetic field on particle trajectories is minimal. We provide angular and energy-resolved flux estimates and discuss their relevance as background for extensive air shower detection. Furthermore, our results are potentially relevant for interpreting data from current and future balloon-borne experiments such as EUSO-SPB2 and for refining trigger and veto strategies in Cherenkov and fluorescence telescopes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A gaseous RICH detector for SiD or ILD

This paper describes a preliminary study of a gaseous Ring Imaging Cherenkov (RICH) system capable of discriminating between kaons and pions at high momenta — up to 50 GeV/c — and thus enhancing particle identification at future colliders. The system possesses a compact design, facilitating easy integration into existing detector concepts. Here, a study of the key contributions to the Cherenkov angle resolution is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geant4 simulations of sampling and homogeneous hadronic calorimeters with dual readout for future colliders

Calorimeters with dual readout measure both scintillation and Cherenkov light produced in their active media. They offer improvements in energy resolution and, therefore, have become increasingly interesting due to the need for precision jet measurements at Higgs factories. Furthermore, this paper presents GEANT4 simulations of single-particle responses in sampling and homogeneous calorimeters, and demonstrates the effect of inclusion of Cherenkov light in the reconstruction of energies.

Detector modeling and simulations↗

HRPPD photosensors for RICH detectors with a high resolution timing capability

Recently, a new version of DC-coupled High Rate Picosecond Photodetectors (DC-HRPPDs) substantially re-designed for use at the Electron-Ion Collider (EIC) has been developed. A first batch of seven “EIC HRPPDs” was manufactured in early 2024. These HRPPDs are DC-coupled photosensors based on Micro-Channel Plates (MCPs) that have an active area of 104 mm by 104 mm, 32 × 32 direct readout pixel array at a pitch of 3.25 mm, peak quantum efficiency in excess of 30%, exceptionally low dark count rates and timing resolution of 15–20 ps for a single photon detection. As such, these photosensors are very well suited for Ring Imaging CHerenkov (RICH) detectors that can additionally provide high resolution timing capability, especially in a configuration where a detected charged particle passes through the sensor window, which produces a localized flash containing a few dozens of Cherenkov photons in it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Strip-based Scintillation Detector for Dual-readout High-granularity Calorimetry

New calorimeter technology is being developed for future collider experiments. We are developing a calorimeter that integrates two technologies, a high-granularity calorimeter and a dual-readout calorimeter, and has high time resolution at a picosecond level. The proposed calorimeter is a sampling calorimeter based on scintillation and Cherenkov detectors with high-granularity readout. The Cherenkov detector has a picosecond level time resolution. For the high-granularity scintillation detector, scintillator strips of 300mm × 30mm ×3mm-thick are aligned horizontally and vertically to realize an effective 30mm-square-cell segmentation. Prototype strips with different designs and scintillator materials were tested to compare the performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent high-power RF wakefield generation by electron bunch trains in a metamaterial structure

In this paper, we present an experimental study of coherent high-power wakefield generation in a metamaterial (MTM) structure at 11.7 GHz by 65 MeV electron bunch trains at the Argonne Wakefield Accelerator (AWA), following a previous experiment, the Stage-I experiment, at the AWA. Both the Stage-II experiment, reported in this paper, and the Stage-I experiment were conducted using MTM structures, which are all-metal periodic structures with the period being much smaller than the wavelength. Differences between the two experiments include (1) structure length (Stage-I 8 cm and Stage-II 20 cm); (2) number of bunches used to excite the structure (Stage-I with two bunches, up to 85 nC of total charge; Stage-II with eight bunches, up to 224 nC of total charge); and (3) highest peak power measured (Stage-I 80 MW in a 2 ns pulse and Stage-II 380 MW in a 10 ns pulse). High-power radio frequency pulses were generated by reversed Cherenkov radiation of the electron beam due to the negative group velocity in the MTM structures. Because the radiation is coherent, a train of bunches with a proper spacing can build up to achieve a high peak power. The observed output power levels are very promising for future applications in direct collinear wakefield acceleration or in transfer to a second accelerator for two-beam acceleration.

36 MATERIALS SCIENCE↗

Proof-of-concept of a neutron time-of-flight ellipsoidal detector

The time-resolved measurement of neutrons emitted from nuclear implosions at inertial confinement fusion facilities is used to characterize the fusing plasma. Several significant quantities are routinely measured by neutron time-of-flight (nToF) detectors in these experiments. Current nToF detectors use scintillators as well as solid-state Cherenkov radiators. The latter has an inherently faster time response and can provide a co-registered γ-ray measurement as well as improved precision in the bulk hot-spot velocity. This work discusses a nToF ellipsoidal detector that also utilizes a solid-state Cherenkov radiator. The detector has the potential to achieve a fast instrument response function allowing for characterization of the γ-ray burn history as well as the ability to field the detector closer to the fusion source. Proof-of-concept testing of the nToF ellipsoidal detector has been conducted at the National Ignition Facility using commercial optics. A time-resolved neutron signal has been measured from the diagnostic. Preliminary simulations corroborate the results.

Jeet, J. (ORCID:0000000291091563)↗

Initial assessment of second generation of large-area picosecond photodetectors with multi-channel systems-on-a-chip readout

Here, we first briefly describe the history and motivation behind Cherenkov and scintillation light detection. We then discuss the instrumentation needed to detect these photons as it applies to both photodetectors and readout electronics. One of the motivations is future large neutrino detectors that could, in principle, differentiate between Cherenkov and scintillation light if using novel water-based scintillators. In this paper, we present the first measurements utilizing the second generation of Large Area Picosecond Photodetectors (LAPPDs) in conjunction with commercial system-on-a-chip readouts from Nalu Scientific—in particular, the High Density System on Chip (HDSoC) and Advanced ASoC Rapid Digitizer, Variable Adaptive Readout Chip (AARDVARC) platforms. These state-of-the-art full-waveform digitizers feature sampling rates on the order of 1 and 10 samples per nanosecond, respectively. Using a picosecond laser, we measured the timing jitter between a pair of LAPPD channels, demonstrating the potential of this setup for precise timing applications.

Li, V. A. [Lawrence Livermore National Laboratory ↗

The POEMMA (Probe of Extreme Multi-Messenger Astrophysics) observatory

The Probe Of Extreme Multi-Messenger Astrophysics (POEMMA) is designed to accurately observe ultra-high-energy cosmic rays (UHECRs) and cosmic neutrinos from space with sensitivity over the full celestial sky. POEMMA will observe the air fluorescence produced by extensive air showers (EASs) from UHECRs and potentially UHE neutrinos above 20 EeV. Additionally, POEMMA has the ability to observe the Cherenkov signal from upward-moving EASs induced by Earth-interacting tau neutrinos above 20 PeV. The POEMMA spacecraft are designed to quickly re-orientate to follow up transient neutrino sources and obtain currently unparalleled neutrino flux sensitivity. Developed as a NASA Astrophysics Probe-class mission, POEMMA consists of two identical satellites flying in loose formation in 525 km altitude orbits. Each POEMMA instrument incorporates a wide field-of-view (45°) Schmidt telescope with an optical collecting area of over 6 m 2 . The hybrid focal surface of each telescope includes a fast (1 μs) near-ultraviolet camera for EAS fluorescence observations and an ultrafast (10 ns) optical camera for Cherenkov EAS observations. In a 5-year mission, POEMMA will provide measurements that open new multi-messenger windows onto the most energetic events in the universe, enabling the study of new astrophysics and particle physics at these extreme energies.

Astronomy & Astrophysics↗

An optimized search for dark matter in the galactic halo with HAWC

The Galactic Halo is a key target for indirect dark matter detection. The High Altitude Water Cherenkov (HAWC) observatory is a high-energy (~300 GeV to >100 TeV) gamma-ray detector located in central Mexico. HAWC operates via the water Cherenkov technique and has both a wide field of view of ~ 2 sr and a >95% duty cycle, making it ideal for analyses of highly extended sources. We made use of these properties of HAWC and a new background-estimation technique optimized for extended sources to probe a large region of the Galactic Halo for dark matter signals. With this approach, we set improved constraints on dark matter annihilation and decay between masses of 10 and 100 TeV. Due to the large spatial extent of the HAWC field of view, these constraints are robust against uncertainties in the Galactic dark matter spatial profile.

79 ASTRONOMY AND ASTROPHYSICS↗

Combined dark matter search towards dwarf spheroidal galaxies with Fermi -LAT, HAWC, H.E.S.S., MAGIC, and VERITAS

Dwarf spheroidal galaxies (dSphs) are excellent targets for indirect dark matter (DM) searches using gamma-ray telescopes because they are thought to have high DM content and a low astrophysical background. The sensitivity of these searches is improved by combining the observations of dSphs made by different gamma-ray telescopes. We present the results of a combined search by the most sensitive currently operating gamma-ray telescopes, namely: the satellite-borne Fermi -LAT telescope; the ground-based imaging atmospheric Cherenkov telescope arrays H.E.S.S., MAGIC, and VERITAS; and the HAWC water Cherenkov detector. Individual datasets were analyzed using a common statistical approach. Results were subsequently combined via a global joint likelihood analysis. We obtain constraints on the velocity-weighted cross section 〈σv〉 for DM self-annihilation as a function of the DM particle mass. This five-instrument combination allows the derivation of up to 2-3 times more constraining upper limits on 〈σv〉 than the individual results over a wide mass range spanning from 5 GeV to 100 TeV. Depending on the DM content modeling, the 95% confidence level observed limits reach 1.5×10 -24 cm 3 s -1 and 3.2×10 -25 cm 3 s -1 , respectively, in the τ + τ - annihilation channel for a DM mass of 2 TeV.

79 ASTRONOMY AND ASTROPHYSICS↗

A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level

Abstract The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a photocathode operating in a semi-transparent mode and a Micromegas amplification structure. The first proof of concept single-channel prototype was able to achieve a time resolution below 25 ps. One of the crucial aspects in the development of precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm 2 suffered from degraded timing resolution due to the non-uniformity of the preamplification gap thickness. A new 100 cm 2 detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over the measured pads and a time resolution below 25 ps. More recent measurements with a thinner drift gap detector module and newly developed RF pulse amplifiers show that the pad centre resolution can be enhanced to the level of 17 ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.

Utrobicic, A.↗