Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Checklist”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Community-Driven Metadata Standards for Agricultural Microbiome Research

Accelerating the pace of microbiome science to enhance crop productivity and agroecosystem health will require transdisciplinary studies, comparisons among datasets, and synthetic analyses of research from diverse crop management contexts. However, despite the widespread availability of crop-associated microbiome data, variation in field sampling and laboratory processing methodologies, as well as metadata collection and reporting, significantly constrains the potential for integrative and comparative analyses. Here we discuss the need for agriculture-specific metadata standards for microbiome research, and propose a list of “required” and “desirable” metadata categories and ontologies essential to be included in a future minimum information metadata standards checklist for describing agricultural microbiome studies. We begin by briefly reviewing existing metadata standards relevant to agricultural microbiome research, and describe ongoing efforts to enhance the potential for integration of data across research studies. Our goal is not to delineate a fixed list of metadata requirements. Instead, we hope to advance the field by providing a starting point for discussion, and inspire researchers to adopt standardized procedures for collecting and reporting consistent and well-annotated metadata for agricultural microbiome research.

59 BASIC BIOLOGICAL SCIENCES↗

Design and Evaluation of joint resistance in SSC Rutherford type cable splices for Torus magnet for the Jefferson Lab 12 GeV Upgrade

The Hall B 3.6-T superconducting torus magnet is being designed and built as part of the Jefferson Lab 12-GeV upgrade. The magnet consists of six trapezoidal coils connected in series, with an operating current of 3770 A. The magnet and the joints (or splices) connecting the coils are all conduction cooled by supercritical 4.6-K helium. This paper studies the design and manufacturing process of the splices made between two SSC Rutherford-type cables and discusses the tests performed to evaluate the performance of the splices under varying incident magnetic fields.

Ghoshal, Probir K.↗

Implementation of early psychosis services in Latin America: A scoping review

Abstract Aim The evidence of the effectiveness and cost‐effectiveness of early intervention for psychosis (EIP) services has motivated their implementation worldwide. However, complex interventions of such EIP services require local adaptations to successfully match population needs and cultural differences. Latin America is a heterogenous region where EIP services are progressively being adopted. Our aim is to map such initiatives in the region with a focus on implementation outcomes. Methods A scoping review following the Preferred Reporting Items for Systematic review and Meta‐Analysis extension for Scoping Reviews guidelines was conducted. International and regional databases were searched for publications describing EIP programmes in the region. Besides mapping the services, we described implementation outcomes based on the Standards for Reporting Implementation Studies Checklist. Results Ten articles describing seven EIP initiatives from the region were found. Four countries were represented: Argentina, Brazil, Chile and Mexico. The implementation outcomes reporting was heterogenous, although it was possible to ascertain EIP services are feasible and adequate for the region's context. Also, there is some evidence of effectiveness in terms of reducing hospitalizations and improving symptoms. Information about fidelity measures was scarce and there was no information about costs or cost‐effectiveness. Conclusions Only a small proportion of Latin American countries have adopted EIP services. Although these programmes seem to be feasible and effective, data on other implementation outcomes, such as fidelity, cultural appropriateness, cost‐effectiveness and affordability are not available. This might in part explain why this effective approach has not been yet scaled‐up at nationwide levels.

Aceituno, David↗

Trial of a proposed protocol for constancy control of digital mammography systems

Purpose: Evaluate the utility of tests in a proposed protocol for constancy control of digital mammography systems. Methods: The protocol contained tests for image acquisition, mechanical function and safety, monitors and printers, and viewing conditions. Nine sites with digital systems from four equipment manufacturers were recruited. Dedicated PMMA test objects and Excel spreadsheets were developed. Quantitative measurements were done on processed images for systems where these images were the ones most readily available. For daily assessment of the automatic exposure control system, a homogeneous PMMA phantom was exposed under clinical conditions. The mAs and signal to noise ratio (SNR) were recorded, the deviation from a target value calculated, and the resulting image inspected for artifacts. For thickness tracking, the signal difference to noise ratio obtained for three thicknesses was calculated. Detector uniformity was assessed through comparison of SNR values for regions of interest in the center and corners of an image of a homogeneous test object. Mechanical function and safety control included a compression test, a checklist for mechanical aspects, and control of field alignment. Monitor performance was evaluated by visual inspection of the AAPM TG 18 QC test image [E. Samei et al., ''Assessment of display performance for medical imaging systems,'' Task Group 18 (Madison, WI, April 2005)]. Results: For quantitative parameters, target values and tolerance limits were established. Test results exceeding the limits were registered. Most systems exhibited stable mAs values, indicating that the tolerance limit of {+-}10% was readily achievable. The SNR also showed little variation, indicating that the tolerance limit of {+-}20% was too wide. At one site, a defective grid caused artifacts that were visible in the test images. The monitor controls proved more difficult to implement due to both difficulties importing and displaying the test image, and the radiographic technologists not getting necessary access to the reading stations. Conclusions: The proposed tests could easily be performed by trained radiographic technologists and within a time frame comparable to similar programs for analog systems. Tests with quantitative measures were more readily performed than procedures that required a subjective evaluation. Several of the proposed tests revealed equipment performance that required intervention, and which would otherwise have gone unnoticed. They therefore defend a place in a vendor-independent constancy control protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-18C-06: Initial Experience with Implementing MRI Safety Guidelines for Patients with Pacemakers - Medical Physicist Perspective

Purpose: Several institutions have developed MRI guidelines for patients with MR-unsafe or MR-conditional pacemakers. Here we highlight the role of a medical physicist in implementing these guidelines for non-pacemaker dependent patients. Guidelines: Implementing these guidelines requires involvement from several medical specialties and a strong collaboration with the site MRI supervisor to develop a structured workflow. A medical physicist is required to be present during the scan to supervise the MR scanning and to maintain a safety checklist that ensures: 1) uninterrupted patient communication with the technologist, 2) continuous patient physiologic monitoring (e.g. blood pressure and electrocardiography) by a trained nurse, 3) redundant patient vitals monitoring (e.g. pulse oximetry) due to the possibility of in vivo electrocardiography reading fluctuations during image acquisition. A radiologist is strongly recommended to be available to review the images before patients are discharged from the scanner. Pacemaker MRI should be restricted to 1.5T field strength. The MRI sequences should be optimized by the physicist with regards to: a) SAR: limited to <1.5 W/Kg for MR-unsafe pacemakers in normal operating mode, b) RF exposure time: <30 min, c) Coils: use T/R coils but not restricted to such, d) Artifacts: further optimization of sequences whenever image quality is compromised due to the pacemaker. In particular, cardiac, breast and left-shoulder MRIs are most susceptible to these artifacts. Possible strategies to lower the SAR include: a) BW reduction, 2) echo-train-length reduction, 3) increase TR, 4) decrease number of averages, 5) decrease flip angle, 6) reduce slices and/or a combination of all the options. Conclusion: A medical physicist in collaboration with the MR supervisor plays an important role in the supervision/implementation of safe MR scanning of pacemaker patients. Developing and establishing a workflow has enabled our institution to scan over 30 patients with pacemakers without complications, including 3 cardiac MR exams.

60 APPLIED LIFE SCIENCES↗

SU-E-T-310: Targeting Safety Improvements Through Analysis of Near-Miss Error Detection Points in An Incident Learning Database

Purpose: Radiation treatment planning involves a complex workflow that can make safety improvement efforts challenging. This study utilizes an incident reporting system to identify detection points of near-miss errors, in order to guide our departmental safety improvement efforts. Previous studies have examined where errors arise, but not where they are detected or their patterns. Methods: 1377 incidents were analyzed from a departmental nearmiss error reporting system from 3/2012–10/2013. All incidents were prospectively reviewed weekly by a multi-disciplinary team, and assigned a near-miss severity score ranging from 0–4 reflecting potential harm (no harm to critical). A 98-step consensus workflow was used to determine origination and detection points of near-miss errors, categorized into 7 major steps (patient assessment/orders, simulation, contouring/treatment planning, pre-treatment plan checks, therapist/on-treatment review, post-treatment checks, and equipment issues). Categories were compared using ANOVA. Results: In the 7-step workflow, 23% of near-miss errors were detected within the same step in the workflow, while an additional 37% were detected by the next step in the workflow, and 23% were detected two steps downstream. Errors detected further from origination were more severe (p<.001; Figure 1). The most common source of near-miss errors was treatment planning/contouring, with 476 near misses (35%). Of those 476, only 72(15%) were found before leaving treatment planning, 213(45%) were found at physics plan checks, and 191(40%) were caught at the therapist pre-treatment chart review or on portal imaging. Errors that passed through physics plan checks and were detected by therapists were more severe than other errors originating in contouring/treatment planning (1.81 vs 1.33, p<0.001). Conclusion: Errors caught by radiation treatment therapists tend to be more severe than errors caught earlier in the workflow, highlighting the importance of safety checks in dosimetry and physics. We are utilizing our findings to improve manual and automated checklists for dosimetry and physics.

60 APPLIED LIFE SCIENCES↗

SU-E-T-627: Failure Modes and Effect Analysis for Monthly Quality Assurance of Linear Accelerator

Purpose: To develop and implement a failure mode and effect analysis (FMEA) on routine monthly Quality Assurance (QA) tests (physical tests part) of linear accelerator. Methods: A systematic failure mode and effect analysis method was performed for monthly QA procedures. A detailed process tree of monthly QA was created and potential failure modes were defined. Each failure mode may have many influencing factors. For each factor, a risk probability number (RPN) was calculated from the product of probability of occurrence (O), the severity of effect (S), and detectability of the failure (D). The RPN scores are in a range of 1 to 1000, with higher scores indicating stronger correlation to a given influencing factor of a failure mode. Five medical physicists in our institution were responsible to discuss and to define the O, S, D values. Results: 15 possible failure modes were identified and all RPN scores of all influencing factors of these 15 failue modes were from 8 to 150, and the checklist of FMEA in monthly QA was drawn. The system showed consistent and accurate response to erroneous conditions. Conclusion: The influencing factors of RPN greater than 50 were considered as highly-correlated factors of a certain out-oftolerance monthly QA test. FMEA is a fast and flexible tool to develop an implement a quality management (QM) frame work of monthly QA, which improved the QA efficiency of our QA team. The FMEA work may incorporate more quantification and monitoring fuctions in future.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-408: Evaluation of the Type and Frequency of Variations Discovered During Routine Secondary Patient Chart Review

Purpose: Desire to improve efficiency and throughput inspired a review of our physics chart check procedures. Departmental policy mandates plan checks pre-treatment, after first treatment and weekly every 3–5 days. This study examined the effectiveness of the “after first” check with respect to improving patient safety and clinical efficiency. Type and frequency of variations discovered during this redundant secondary review was examined over seven months. Methods: A community spreadsheet was created to record variations in care discovered during chart review following the first fraction of treatment and before the second fraction (each plan reviewed prior to treatment). Entries were recorded from August 2014 through February 2015, amounting to 43 recorded variations out of 906 reviewed charts. The variations were divided into categories and frequencies were assessed month-to-month. Results: Analysis of recorded variations indicates an overall variation rate of 4.7%. The initial rate was 13.5%; months 2–7 average 3.7%. The majority of variations related to discrepancies in documentation at 46.5%, followed by prescription, plan deficiency, and dose tracking related variations at 25.5%, 12.8%, and 12.8%, respectively. Minor variations (negligible consequence on patient treatment) outweighed major variations 3 to 1. Conclusion: This work indicates that this redundant secondary check is effective. The first month spike in rates could be due to the Hawthorne/observer effect, but the consistent 4% variation rate suggests the need for periodical re-training on variations noted as frequent to improve awareness and quality of the initial chart review process, which may lead to improved treatment quality, patient safety and increased clinical efficiency. Utilizing these results, a continuous quality improvement process following Deming’s Plan-Do-Study-Act (PDSA) methodology was generated. The first iteration of this PDSA was adding a specific dose tracking checklist item in the pre-treatment plan check assessment; the ramification of which will be assessed in future data.

60 APPLIED LIFE SCIENCES↗

SU-E-T-421: Failure Mode and Effects Analysis (FMEA) of Xoft Electronic Brachytherapy for the Treatment of Superficial Skin Cancers

Purpose: To perform a failure mode and effects analysis (FMEA) of the process for treating superficial skin cancers with the Xoft Axxent electronic brachytherapy (eBx) system, given the recent introduction of expanded quality control (QC) initiatives at our institution. Methods: A process map was developed listing all steps in superficial treatments with Xoft eBx, from the initial patient consult to the completion of the treatment course. The process map guided the FMEA to identify the failure modes for each step in the treatment workflow and assign Risk Priority Numbers (RPN), calculated as the product of the failure mode’s probability of occurrence (O), severity (S) and lack of detectability (D). FMEA was done with and without the inclusion of recent QC initiatives such as increased staffing, physics oversight, standardized source calibration, treatment planning and documentation. The failure modes with the highest RPNs were identified and contrasted before and after introduction of the QC initiatives. Results: Based on the FMEA, the failure modes with the highest RPN were related to source calibration, treatment planning, and patient setup/treatment delivery (Fig. 1). The introduction of additional physics oversight, standardized planning and safety initiatives such as checklists and time-outs reduced the RPNs of these failure modes. High-risk failure modes that could be mitigated with improved hardware and software interlocks were identified. Conclusion: The FMEA analysis identified the steps in the treatment process presenting the highest risk. The introduction of enhanced QC initiatives mitigated the risk of some of these failure modes by decreasing their probability of occurrence and increasing their detectability. This analysis demonstrates the importance of well-designed QC policies, procedures and oversight in a Xoft eBx programme for treatment of superficial skin cancers. Unresolved high risk failure modes highlight the need for non-procedural quality initiatives such as improved planning software and more robust hardware interlock systems.

60 APPLIED LIFE SCIENCES↗

MO-B-BRB-00: Optimizing the Treatment Planning Process

The radiotherapy treatment planning process has evolved over the years with innovations in treatment planning, treatment delivery and imaging systems. Treatment modality and simulation technologies are also rapidly improving and affecting the planning process. For example, Image-guided-radiation-therapy has been widely adopted for patient setup, leading to margin reduction and isocenter repositioning after simulation. Stereotactic Body radiation therapy (SBRT) and Radiosurgery (SRS) have gradually become the standard of care for many treatment sites, which demand a higher throughput for the treatment plans even if the number of treatments per day remains the same. Finally, simulation, planning and treatment are traditionally sequential events. However, with emerging adaptive radiotherapy, they are becoming more tightly intertwined, leading to iterative processes. Enhanced efficiency of planning is therefore becoming more critical and poses serious challenge to the treatment planning process; Lean Six Sigma approaches are being utilized increasingly to balance the competing needs for speed and quality. In this symposium we will discuss the treatment planning process and illustrate effective techniques for managing workflow. Topics will include: Planning techniques: (a) beam placement, (b) dose optimization, (c) plan evaluation (d) export to RVS. Planning workflow: (a) import images, (b) Image fusion, (c) contouring, (d) plan approval (e) plan check (f) chart check, (g) sequential and iterative process Influence of upstream and downstream operations: (a) simulation, (b) immobilization, (c) motion management, (d) QA, (e) IGRT, (f) Treatment delivery, (g) SBRT/SRS (h) adaptive planning Reduction of delay between planning steps with Lean systems due to (a) communication, (b) limited resource, (b) contour, (c) plan approval, (d) treatment. Optimizing planning processes: (a) contour validation (b) consistent planning protocol, (c) protocol/template sharing, (d) semi-automatic plan evaluation, (e) quality checklist for error prevention, (f) iterative process, (g) balance of speed and quality Learning Objectives: Gain familiarity with the workflow of modern treatment planning process. Understand the scope and challenges of managing modern treatment planning processes. Gain familiarity with Lean Six Sigma approaches and their implementation in the treatment planning workflow.

60 APPLIED LIFE SCIENCES↗

MO-B-BRB-01: Optimize Treatment Planning Process in Clinical Environment

The radiotherapy treatment planning process has evolved over the years with innovations in treatment planning, treatment delivery and imaging systems. Treatment modality and simulation technologies are also rapidly improving and affecting the planning process. For example, Image-guided-radiation-therapy has been widely adopted for patient setup, leading to margin reduction and isocenter repositioning after simulation. Stereotactic Body radiation therapy (SBRT) and Radiosurgery (SRS) have gradually become the standard of care for many treatment sites, which demand a higher throughput for the treatment plans even if the number of treatments per day remains the same. Finally, simulation, planning and treatment are traditionally sequential events. However, with emerging adaptive radiotherapy, they are becoming more tightly intertwined, leading to iterative processes. Enhanced efficiency of planning is therefore becoming more critical and poses serious challenge to the treatment planning process; Lean Six Sigma approaches are being utilized increasingly to balance the competing needs for speed and quality. In this symposium we will discuss the treatment planning process and illustrate effective techniques for managing workflow. Topics will include: Planning techniques: (a) beam placement, (b) dose optimization, (c) plan evaluation (d) export to RVS. Planning workflow: (a) import images, (b) Image fusion, (c) contouring, (d) plan approval (e) plan check (f) chart check, (g) sequential and iterative process Influence of upstream and downstream operations: (a) simulation, (b) immobilization, (c) motion management, (d) QA, (e) IGRT, (f) Treatment delivery, (g) SBRT/SRS (h) adaptive planning Reduction of delay between planning steps with Lean systems due to (a) communication, (b) limited resource, (b) contour, (c) plan approval, (d) treatment. Optimizing planning processes: (a) contour validation (b) consistent planning protocol, (c) protocol/template sharing, (d) semi-automatic plan evaluation, (e) quality checklist for error prevention, (f) iterative process, (g) balance of speed and quality Learning Objectives: Gain familiarity with the workflow of modern treatment planning process. Understand the scope and challenges of managing modern treatment planning processes. Gain familiarity with Lean Six Sigma approaches and their implementation in the treatment planning workflow.

60 APPLIED LIFE SCIENCES↗

MO-B-BRB-02: Maintain the Quality of Treatment Planning for Time-Constraint Cases

The radiotherapy treatment planning process has evolved over the years with innovations in treatment planning, treatment delivery and imaging systems. Treatment modality and simulation technologies are also rapidly improving and affecting the planning process. For example, Image-guided-radiation-therapy has been widely adopted for patient setup, leading to margin reduction and isocenter repositioning after simulation. Stereotactic Body radiation therapy (SBRT) and Radiosurgery (SRS) have gradually become the standard of care for many treatment sites, which demand a higher throughput for the treatment plans even if the number of treatments per day remains the same. Finally, simulation, planning and treatment are traditionally sequential events. However, with emerging adaptive radiotherapy, they are becoming more tightly intertwined, leading to iterative processes. Enhanced efficiency of planning is therefore becoming more critical and poses serious challenge to the treatment planning process; Lean Six Sigma approaches are being utilized increasingly to balance the competing needs for speed and quality. In this symposium we will discuss the treatment planning process and illustrate effective techniques for managing workflow. Topics will include: Planning techniques: (a) beam placement, (b) dose optimization, (c) plan evaluation (d) export to RVS. Planning workflow: (a) import images, (b) Image fusion, (c) contouring, (d) plan approval (e) plan check (f) chart check, (g) sequential and iterative process Influence of upstream and downstream operations: (a) simulation, (b) immobilization, (c) motion management, (d) QA, (e) IGRT, (f) Treatment delivery, (g) SBRT/SRS (h) adaptive planning Reduction of delay between planning steps with Lean systems due to (a) communication, (b) limited resource, (b) contour, (c) plan approval, (d) treatment. Optimizing planning processes: (a) contour validation (b) consistent planning protocol, (c) protocol/template sharing, (d) semi-automatic plan evaluation, (e) quality checklist for error prevention, (f) iterative process, (g) balance of speed and quality Learning Objectives: Gain familiarity with the workflow of modern treatment planning process. Understand the scope and challenges of managing modern treatment planning processes. Gain familiarity with Lean Six Sigma approaches and their implementation in the treatment planning workflow.

60 APPLIED LIFE SCIENCES↗

MO-B-BRB-03: Systems Engineering Tools for Treatment Planning Process Optimization in Radiation Medicine

The radiotherapy treatment planning process has evolved over the years with innovations in treatment planning, treatment delivery and imaging systems. Treatment modality and simulation technologies are also rapidly improving and affecting the planning process. For example, Image-guided-radiation-therapy has been widely adopted for patient setup, leading to margin reduction and isocenter repositioning after simulation. Stereotactic Body radiation therapy (SBRT) and Radiosurgery (SRS) have gradually become the standard of care for many treatment sites, which demand a higher throughput for the treatment plans even if the number of treatments per day remains the same. Finally, simulation, planning and treatment are traditionally sequential events. However, with emerging adaptive radiotherapy, they are becoming more tightly intertwined, leading to iterative processes. Enhanced efficiency of planning is therefore becoming more critical and poses serious challenge to the treatment planning process; Lean Six Sigma approaches are being utilized increasingly to balance the competing needs for speed and quality. In this symposium we will discuss the treatment planning process and illustrate effective techniques for managing workflow. Topics will include: Planning techniques: (a) beam placement, (b) dose optimization, (c) plan evaluation (d) export to RVS. Planning workflow: (a) import images, (b) Image fusion, (c) contouring, (d) plan approval (e) plan check (f) chart check, (g) sequential and iterative process Influence of upstream and downstream operations: (a) simulation, (b) immobilization, (c) motion management, (d) QA, (e) IGRT, (f) Treatment delivery, (g) SBRT/SRS (h) adaptive planning Reduction of delay between planning steps with Lean systems due to (a) communication, (b) limited resource, (b) contour, (c) plan approval, (d) treatment. Optimizing planning processes: (a) contour validation (b) consistent planning protocol, (c) protocol/template sharing, (d) semi-automatic plan evaluation, (e) quality checklist for error prevention, (f) iterative process, (g) balance of speed and quality Learning Objectives: Gain familiarity with the workflow of modern treatment planning process. Understand the scope and challenges of managing modern treatment planning processes. Gain familiarity with Lean Six Sigma approaches and their implementation in the treatment planning workflow.

60 APPLIED LIFE SCIENCES↗

MO-D-213-01: Workflow Monitoring for a High Volume Radiation Oncology Center

Purpose: Implement a center wide communication system that increases interdepartmental transparency and accountability while decreasing redundant work and treatment delays by actively monitoring treatment planning workflow. Methods: Intake Management System (IMS), a program developed by ProCure Treatment Centers Inc., is a multi-function database that stores treatment planning process information. It was devised to work with the oncology information system (Mosaiq) to streamline interdepartmental workflow.Each step in the treatment planning process is visually represented and timelines for completion of individual tasks are established within the software. The currently active step of each patient’s planning process is highlighted either red or green according to whether the initially allocated amount of time has passed for the given process. This information is displayed as a Treatment Planning Process Monitor (TPPM), which is shown on screens in the relevant departments throughout the center. This display also includes the individuals who are responsible for each task.IMS is driven by Mosaiq’s quality checklist (QCL) functionality. Each step in the workflow is initiated by a Mosaiq user sending the responsible party a QCL assignment. IMS is connected to Mosaiq and the sending or completing of a QCL updates the associated field in the TPPM to the appropriate status. Results: Approximately one patient a week is identified during the workflow process as needing to have his/her treatment start date modified or resources re-allocated to address the most urgent cases. Being able to identify a realistic timeline for planning each patient and having multiple departments communicate their limitations and time constraints allows for quality plans to be developed and implemented without overburdening any one department. Conclusion: Monitoring the progression of the treatment planning process has increased transparency between departments, which enables efficient communication. Having built-in timelines allows easy prioritization of tasks and resources and facilitates effective time management.

60 APPLIED LIFE SCIENCES↗

WE-G-BRA-03: Developing a Culture of Patient Safety Utilizing the National Radiation Oncology Incident Learning System (ROILS)

Purpose: To transition from an in-house incident reporting system to a ROILS standards system with the intent to develop a safety focused culture in the Department and enroll in ROILS. Methods: Since the AAPM Safety Summit (2010) several safety and reporting systems have been implemented within the Department. Specific checklists and SBAR reporting systems were introduced. However, the active learning component was lost due to reporting being viewed with distrust and possible retribution.To Facilitate introducing ROILS each leader in the Department received a copy of the ROILS participation guide. Four specific tasks were assigned to each leader: develop a reporting tree, begin the ROILS based system, facilitate adopting ROILS Terminology, and educate the staff on expectations of safety culture. Next, the ROILS questions were broken down into area specific questions (10–15) per departmental area. Excel spreadsheets were developed for each area and setup for error reporting entries. The Role of the Process Improvement Committee (PI) has been modified to review and make recommendations based on the ROILS entries. Results: The ROILS based Reporting has been in place for 4 months. To date 64 reports have been entered. Since the adoption of ROILS the reporting of incidents has increased from 2/month to 18/month on average. Three reports had a dosimetric effect on the patient (<5%) dose variance. The large majority of entries have been Characterized as Processes not followed or not sure how to Characterize, and Human Behavior. Conclusion: The majority of errors are typo’s that create confusion. The introduction of the ROILS standards has provided a platform for making changes to policies that increase patient safety. The goal is to develop a culture that sees reporting at a national level as a safe and effective way to improve our safety, and to dynamically learn from other institutions reporting.

60 APPLIED LIFE SCIENCES↗

Technical Note: Dosimetry of Leipzig and Valencia applicators without the plastic cap

Purpose: High dose rate (HDR) brachytherapy for treatment of small skin lesions using the Leipzig and Valencia applicators is a widely used technique. These applicators are equipped with an attachable plastic cap to be placed during fraction delivery to ensure electronic equilibrium and to prevent secondary electrons from reaching the skin surface. The purpose of this study is to report on the dosimetric impact of the cap being absent during HDR fraction delivery, which has not been explored previously in the literature. Methods: GEANT4 Monte Carlo simulations (version 10.0) have been performed for the Leipzig and Valencia applicators with and without the plastic cap. In order to validate the Monte Carlo simulations, experimental measurements using radiochromic films have been done. Results: Dose absorbed within 1 mm of the skin surface increases by a factor of 1500% for the Leipzig applicators and of 180% for the Valencia applicators. Deeper than 1 mm, the overdosage flattens up to a 10% increase. Conclusions: Differences of treating with or without the plastic cap are significant. Users must check always that the plastic cap is in place before any treatment in order to avoid overdosage of the skin. Prior to skin HDR fraction delivery, the timeout checklist should include verification of the cap placement.

60 APPLIED LIFE SCIENCES↗

SU-F-T-234: Quality Improvements in the Electronic Medical Record of Patients Treated with High Dose-Rate Brachytherapy

Purpose: To improve workflow efficiency and patient safety by assessing the quality control documentation for HDR brachytherapy within our Electronic Medical Record System (Mosaiq). Methods: A list of parameters based on NRC regulations, our quality management program (QMP), recommendations of the ACR and the American Brachytherapy Society, and HDR treatment planning risks identified in our previous FMEA study was made. Next, the parameter entries were classified according to the type of data input—manual, electronic, or both. Manual entry included the electronic Brachytherapy Treatment Record (BTR) and pre-treatment Mosaiq Assessments list. Oncentra Treatment Reports (OTR) from the Oncentra Treatment Control System constituted the electronic data. The OTR includes a Pre-treatment Report for each fraction, and a Treatment Summary Report at the completion of treatment. Each entry was then examined for appropriateness and completeness of data; adjustments and additions as necessary were then made. Results: Ten out of twenty-one recorded treatment parameters were identified to be documented within both the BTR and OTR. Of these ten redundancies, eight were changed from recorded values to a simple checklist in the BTR to avoid recording errors. The other redundancies were kept in both documents due to their value to ensuring patient safety. An edit was made to the current BTR quality assessment; this change revises the definition of a medical event in accordance with ODH Regulation 3701:1-58-101. One addition was made to the current QMP documents regarding HDR. This addition requires a physician to be present through the duration of HDR treatment in accordance with ODH Regulation 3701:1-58-59; Paragraph (F); Section (2); Subsection (a). Conclusion: Careful examination of HDR documentation that originates from different sources can help to improve the accuracy and reliability of the documents. In addition, there may be a small improvement in efficiency due to elimination of unnecessary redundancies.

60 APPLIED LIFE SCIENCES↗

SU-F-T-251: The Quality Assurance for the Heavy Patient Load Department in the Developing Country: The Primary Experience of An Entire Workflow QA Process Management in Radiotherapy

Purpose: To implement an entire workflow quality assurance (QA) process in the radiotherapy department and to reduce the error rates of radiotherapy based on the entire workflow management in the developing country. Methods: The entire workflow QA process management starts from patient registration to the end of last treatment including all steps through the entire radiotherapy process. Error rate of chartcheck is used to evaluate the the entire workflow QA process. Two to three qualified senior medical physicists checked the documents before the first treatment fraction of every patient. Random check of the treatment history during treatment was also performed. A total of around 6000 patients treatment data before and after implementing the entire workflow QA process were compared from May, 2014 to December, 2015. Results: A systemic checklist was established. It mainly includes patient’s registration, treatment plan QA, information exporting to OIS(Oncology Information System), documents of treatment QAand QA of the treatment history. The error rate derived from the chart check decreases from 1.7% to 0.9% after our the entire workflow QA process. All checked errors before the first treatment fraction were corrected as soon as oncologist re-confirmed them and reinforce staff training was accordingly followed to prevent those errors. Conclusion: The entire workflow QA process improved the safety, quality of radiotherapy in our department and we consider that our QA experience can be applicable for the heavily-loaded radiotherapy departments in developing country.

60 APPLIED LIFE SCIENCES↗