The effects of reduced oxygen and of carbon monoxide on performance in a mouse pole-jump apparatus

The effects on reaction time and behavior were studied for exposure to reduced oxygen concentrations in the presence and absence of carbon monoxide. Tests were run with Swiss Webster mice in a pole-jump apparatus. The results show that reaction times increase gradually with a decrease in oxygen (O2) to 10 percent O2. Below 10 percent O2 reaction times increase dramatically and performance is degraded almost immediately. At carbon monoxide (CO) concentrations of 500 ppm and reduced O2 levels, reaction times are increased even more. At CO concentrations of 1000 ppm, performance is nearly completely degraded even without reduced oxygen levels.

Cagliostro, D. E.↗

Regulation of cyclic nucleotide-gated channels and membrane excitability in olfactory receptor cells by carbon monoxide

1. The effect of the putative neural messenger carbon monoxide (CO) and the role of the cGMP second-messenger system for olfactory signal generation was examined in isolated olfactory receptor neurons (ORNs) of the tiger salamander. 2. With the use of whole cell voltage-clamp recordings in combination with a series of ionic and pharmological tests, it is demonstrated that exogenously applied CO is a potent activator (K1/2 = 2.9 microM) of cyclic nucleotide-gated (CNG) channels previously described to mediate odor transduction. 3. Several lines of evidence suggest that CO mediates its effect through stimulation of a soluble guanylyl cyclase (sGC) leading to formation of the second-messenger cGMP. This conclusion is based on the findings that CO responses show an absolute requirement for guanosine 5'-triphosphate (GTP) in the internal solution, that no direct effect of CO on CNG currents in the absence of GTP is detectable, and that a blocker of sGC activation, LY85383 (10 microM), completely inhibits the CO response. 4. The dose-response curve for cGMP at CNG channels is used as a calibration to provide a quantitative estimate of the CO-stimulated cGMP formation. This analysis implies that CO is a potent activator of olfactory sGC. 5. Perforated patch recordings using amphotericin B demonstrate that low micromolar doses of CO effectively depolarize the membrane potential of ORNs through tonic activation of CNG channels. This effect in turn regulates excitable and adaptive properties of ORNs and modulates neuronal responsiveness. 6. These data argue for an important role of the cGMP pathway in olfactory signaling and support the idea that CO may function as a diffusible messenger in the olfactory system.

NASA Discipline Neuroscience↗

The effect of ambient conditions on carbon monoxide emissions from an idling gas turbine combustor

A test program employing a gas turbine combustor is outlined; the results of which quantize the effects of changes in ambient temperature and humidity on carbon monoxide emissions at simulated idle operating conditions. A comparison of the experimental results with analytical results generated by a kinetic model of the combustion process, and reflecting changing ambient conditions, is given. It is demonstrated that for a complete range of possible ambient variations, significant changes do occur in the amount of carbon monoxide emitted by a gas turbine at idle, and that the analytical model is reasonably successful in predicting changes.

Subramanian, A. K.↗

Combustion characteristics of hydrogen. Carbon monoxide based gaseous fuels

An experimental rig program was conducted with the objective of evaluating the combuston performance of a family of fuel gases based on a mixture of hydrogen and carbon monoxide. These gases, in addition to being members of a family, were also representative of those secondary fuels that could be produced from coal by various gasification schemes. In particular, simulated Winkler, Lurgi, and Blue-water low and medium energy content gases were used as fuels in the experimental combustor rig. The combustor used was originally designed as a low NOx rich-lean system for burning liquid fuels with high bound nitrogen levels. When used with the above gaseous fuels this combustor was operated in a lean-lean mode with ultra long residence times. The Blue-water gas was also operated in a rich-lean mode. The results of these tests indicate the possibility of the existence of an 'optimum' gas turbine hydrogen - carbon monoxide based secondary fuel. Such a fuel would exhibit NOx and high efficiency over the entire engine operating range. It would also have sufficient stability range to allow normal light-off and engine acceleration. Solar Turbines Incorporated would like to emphasize that the results presented here have been obtained with experimental rig combustors. The technologies generated could, however, be utilized in future commercial gas turbines.

Notardonato, J. J.↗

Some effects of argon and helium upon explosions of carbon monoxide and oxygen

Report presents the results of an investigation conducted to study the effects of the inert gases, argon and helium, upon flame speed and expansion ratio in exploding mixtures of carbon monoxide, oxygen and water.For the particular gas mixtures investigated the results show that: (1) With the possible exception of helium in small amounts the addition of inert gas always produces decreased flame speed and expansion ratio; (2) like volumes of argon and helium have very different effects upon flame speed but practically the same effect upon expansion ratio; and (3) the difference in the effect of these two gases upon speed is independent of the ratio of carbon monoxide to oxygen. A discussion of some possible modes by which inert gases may produce the observed effects is included.

Fiock, Ernst F↗

Analysis of the feasibility of an experiment to measure carbon monoxide in the atmosphere

The feasibility of measuring atmospheric carbon monoxide from a remote platform using the correlation interferometry technique was considered. It has been determined that CO data can be obtained with an accuracy of 10 percent using this technique on the first overtone band of CO at 2.3 mu. That band has been found to be much more suitable than the stronger fundamental band at 4.6 mu. Calculations for both wavelengths are presented which illustrate the effects of atmospheric temperature profiles, inversion layers, ground temperature and emissivity, CO profile, reflectivity, and atmospheric pressure. The applicable radiative transfer theory on which these calculations are based is described together with the principles of the technique.

Bortner, M. H.↗

Carbon monoxide measurement in the global atmospheric sampling program

The carbon monoxide measurement system used in the NASA Global Atmospheric Sampling Program (GASP) is described. The system used a modified version of a commercially available infrared absorption analyzer. The modifications increased the sensitivity of the analyzer to 1 ppmv full scale, with a limit of detectability of 0.02 ppmv. Packaging was modified for automatic, unattended operation in an aircraft environment. The GASP system is described along with analyzer operation, calibration procedures, and measurement errors. Uncertainty of the CO measurement over a 2-year period ranged from + or - 3 to + or - 13 percent of reading, plus an error due to random fluctuation of the output signal + or - 3 to + or - 15 ppbv.

Dudzinski, T. J.↗

Concentration of carbon monoxide in the upper stratosphere

The concentration of telluric carbon monoxide has been determined in the upper stratosphere from infrared solar spectra recorded by balloon in October 1978 and September 1979, over Texas. The average mixing ratios were found to be (2.1 plus or minus 3) x 10 to the -8th ppv and (3.7 plus or minus 0.4) x 10 the the -8th ppv above the float altitudes of 30.6 and 36.8 km, respectively. The concentration profile deduced from all the measurements indicates that the CO mixing ratio increases in the upper stratosphere, from (1 plus or minus 0.3) x 10 to the -8th ppv at 30.6 km, to about 4 x 10 to the -8th ppv above 41 km.

Zander, R.↗

Carbon Monoxide Detector

Beckman Instruments, Inc. has introduced another technical approach to pollution detection which was used aboard Skylab. This technique, developed with Ames assistance is known as nondispersive infrared spectroscopy. Previous nondispersive analyzers could not selectively distinguish between water vapor and carbon monoxide, thus necessitating water removal by another device before measurement. These analyzers also were susceptible to vibrations and other problems. New instrument which stimulates fluorescent in two carbon monoxide isotopes in two sealed cells, eliminates these problems and increases sensitivity to a tenth of a part per million.

Source record↗

Carbon Monoxide Accumulation in the Extravehicular Mobility Unit

Introduction: Life support technology in large closed systems like submarines and space stations catalyzes carbon monoxide (CO) to carbon dioxide, which is easily removed. However, in a small system like the Extravehicular Mobility Unit (EMU), spacesuit, CO from exogenous (contaminated oxygen (O (sub 2) supply) and endogenous (human metabolism) sources will accumulate in the free suit volume. The free volume becomes a sink for CO that is rebreathed by the astronaut. The accumulation through time depends on many variables: the amount absorbed by the astronaut, the amount produced by the astronaut (between 0.28 and 0.34 moles per hour per kilogram)[1], the amount that enters the suit from contaminated O (sub 2), the amount removed through suit leak, the free volume of the suit, and the O (sub 2) partial pressure[2], just to list a few. Contamination of the EMU O (sub 2) supply with no greater than 1 part per million CO was the motivation for empirical measurements from CO pulse oximetry (SpCO) as well as mathematical modeling of the EMU as a rebreather for CO. Methods: We developed a first-order differential mixing equation as well as an iterative method to compute CO accumulation in the EMU. Pre-post measurements of SpCO (Rad-57, Masimo Corporation) from EMU ground training and on-orbit extravehicular activities (EVAs) were collected. Results: Initial modeling without consideration of the astronaut as a sink but only the source of CO showed that after 8 hours breathing 100 percent O (sub 2) with a 10 milliliter per minute (760 millimeters Hg at 21 degrees Centigrade standard) suit leak, an endogenous production rate of 0.23 moles per hour per kilogram for a 70 kilogram person with 42 liters (1.5 cubic feet) free suit volume resulted in a peak CO partial pressure (pCO) of 0.047 millimeters Hg at 4.3 pounds per square inch absolute (222 millimeters Hg). Preliminary results based on a 2008 model[3] with consideration of the astronaut as a sink and source of CO suggests that most of the rebreathed CO stays bound to hemoglobin and myoglobin and; therefore, pCO only increased to 0.002 millimeters Hg in the EMU. Hemoglobin saturation after 8 hours was an insignificant 0.4 percent compared to about 4 percent for cigarette smokers in the general population. This preliminary modeling result supplements 11 pre-post index finger SpCO measurements from EMU ground training (mean 0.5 percent versus 1 percent, probability equal to 0.41 from paired t-test) and 10 on-orbit pre-post EVAs (mean 1.5 percent versus 1.1 percent, probability equal to 0.17 from paired t-test) that showed no consistent increase, at least no increase outside the accuracy of the oximeter (1 percent display resolution with plus or minus 3 percent Standard Deviation). Discussion: Simulations continue, but a preliminary conclusion is that rebreathing endogenous CO accumulating in the EMU is not a serious medical issue during EVA. The absence of CO poisoning signs or symptoms following hundreds of EVAs is also good empirical evidence that corroborates the limited SpCO measurements and preliminary modeling results.

Conkin, J.↗

The effect of ambient temperature and humidity on the carbon monoxide emissions of an idling gas turbine

Changes in ambient temperature and humidity affect the exhaust emissions of a gas turbine engine. The results of a test program employing a JT8D combustor are presented which quantize the effect of these changes on carbon monoxide emissions at simulated idle operating conditions. Analytical results generated by a kinetic model of the combustion process and reflecting changing ambient conditions are given. It is shown that for a complete range of possible ambient variations, significant changes do occur in the amount of carbon monoxide emitted by a gas turbine engine.

Kauffman, C. W.↗

An analytical study of nitrogen oxides and carbon monoxide emissions in hydrocarbon combustion with added nitrogen - Preliminary results

The influence of ground-based gas turbine combustor operating conditions and fuel-bound nitrogen (FBN) found in coal-derived liquid fuels on the formation of nitrogen oxides and carbon monoxide is investigated. Analytical predictions of NOx and CO concentrations are obtained for a two-stage, adiabatic, perfectly-stirred reactor operating on a propane-air mixture, with primary equivalence ratios from 0.5 to 1.7, secondary equivalence ratios of 0.5 or 0.7, primary stage residence times from 12 to 20 msec, secondary stage residence times of 1, 2 and 3 msec and fuel nitrogen contents of 0.5, 1.0 and 2.0 wt %. Minimum nitrogen oxide but maximum carbon monoxide formation is obtained at primary zone equivalence ratios between 1.4 and 1.5, with percentage conversion of FBN to NOx decreasing with increased fuel nitrogen content. Additional secondary dilution is observed to reduce final pollutant concentrations, with NOx concentration independent of secondary residence time and CO decreasing with secondary residence time; primary zone residence time is not observed to affect final NOx and CO concentrations significantly. Finally, comparison of computed results with experimental values shows a good semiquantitative agreement.

Bittker, D. A.↗

Nano-crystalline porous tin oxide film for carbon monoxide sensing

A tin oxide sol is deposited on platinum electrodes (12) of a sensor (10). The sol is calcined at a temperature of 500 to 800.degree. C. to produce a thin film of tin oxide with a thickness of about 150 nm to 2 .mu. and having a nano-crystalline structure with good stability. The sensor rapidly detects reducing gases, such as carbon monoxide, or hydrocarbons and organic vapors. Sensors using films calcined at around 700.degree. C. have high carbon monoxide selectivity with a response time of around 4 minutes and a recovery time of 1 minute, and therefore provide good detection systems for detection of trace amounts of pollutants such as toxic and flammable gases in homes, industrial settings, and hospitals.

Liu, Chung-Chiun↗