Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Calorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

COLUTA: Custom 8-Channel 15-bit 40-MSPS ADC for the ATLAS Liquid Argon Calorimeter Readout

The stringent radiation-tolerance, quantization requirements, and the need for seamless integration of the on-detector readout electronics chain require the design of a full-custom analog-to-digital converter (ADC) for the 182,468 channels in the ATLAS Liquid Argon (LAr) calorimeter at the Large Hadron Collider (LHC) at CERN, as part of the High-Luminosity LHC (HL-LHC) upgrade. Each of the 8 channels in the prototype 65 nm CMOS ADC with 15-bit resolution and >68 dB signal-to-noise-and-distortion ratio (SNDR), or equivalently >11 effective number of bits (ENOB), consists of a Multiplying-DAC (MDAC) and a successive-approximation (SAR) ADC. A digital data processing unit (DDPU) calibrates and serially transmits the quantized data. Initial lab characterization of 18 chips shows a minimum SNDR of 69.5 dB at full-scale at about 5 MHz and a maximum power consumption of 1.17 W; differential non-linearity (DNL) measurements show no missing codes. Additional validation of the ADC is ongoing before approximately 70k chips can be mass-produced for the upgrade.

Rui Xu↗

Experimental tests of a single-photon calorimeter for X-ray spectroscopy

Tests have been made of a nondispersive spectroscopic X-ray detector which operates by measuring the temperature rise following absorption of a single photon. Thermal pulses from 6-keV X-rays have been observed, and the different amplitudes resulting from Mn K-alpha and K-beta events have been resolved. This device was assembled to make quantitative tests of theoretical calculations of the properties of such detectors, and its high heat capacity does not allow it to attain the very high resolution predicted for detectors made by more sophisticated, but still straightforward, techniques. Both the measured resolution of 270-eV full width at half maximum and the absolute amplitude of the response are consistent with predictions. Nonthermal effects in the thermistor limit the precision of this comparison to about 30 percent.

Mccammon, D.↗

NBC boil-off calorimeter for measuring thermal conductivity of insulating materials

Modern temperature, pressure and flow sensors along with a high speed digital control system have been incorporated into an existing thermal conductivity apparatus (ASTM C745). The system has also been modified to include the use of liquid helium as the refrigerant, if desired. The apparatus can be used to study thermal conductivity in the temperature range from 4 K to room temperature. Preliminary results on insulating materials indicate that the system update has significantly improved the precision and operational characteristics of the apparatus. Basic principles of operation, sources of system error and the reduction of system error by application of digital control and modern sensors are discussed. Preliminary data are presented.

Dube, W. P.↗

Progress in kinetic inductance thermometers for X-ray calorimeters

Conventional X-ray microcalorimeters have so far used ionimplanted resistors for thermometers. Recently, however, several new methods for sensing small temperature changes have been suggested that are nondissipative. Such devices may have intrinsically better energy resolution by eliminating the Johnson noise present in resistive devices. The use of kinetic inductance thermometers for X-ray microcalorimeters is being investigated. This technique exploits the strong temperature dependence of magnetic penetration depth of thin superconducting films. The prototype system, designed for operation at 1.5 K, uses films of aluminum and tin. Once the expected temperature sensitivity and alpha particle detection have been demonstrated, aluminum will be replaced with titanium or another material with a suitable critical temperature and the device will be operated at 0.3 K. At this temperature, the energy resolution from thermal noise should be sufficiently good to allow X-ray detection.

Rawley, G. L.↗

Characterization and wall compatibility testing of a 40K pound thrust class swirl-coaxial injector and calorimeter combustion chamber

Subscale injector-combustor tests under the NASA Space Transportation Engine Thrust Chamber Technology program measured characteristic velocity (c-asterisk) efficiencies and wall heat fluxes for the pressure range 1710 psia to 2360 psia and for the overall O2/H2 mixture ratio range 5.5 to 6.4. Tests involving radially-uniform mixture ratio profiles produced c-asterisk efficiencies above 99 percent; nonuniform profiles associated with wall durability-enhancement schemes resulted in lower efficiencies. Though all three wall protection methods proved successful at reducing wall heat flux, scarfing of the outer-row, swirl-coaxial injection elements was the technique which resulted in the least debit in c-asterisk per unit reduction in heat flux.

Petersen, E. L.↗

Heat flux sensor research and development: The cool film calorimeter

The goal was to meet the measurement requirement of the NASP program for a gauge capable of measuring heat flux into a 'typical' structure in a 'typical' hypersonic flight environment. A device is conceptually described that has fast response times and is small enough to fit in leading edge or cowl lip structures. The device relies heavily on thin film technology. The main conclusion is the description of the limitations of thin film technology both in the art of fabrication and in the assumption that thin films have the same material properties as the original bulk material. Three gauges were designed and fabricated. Thin film deposition processes were evaluated. The effect of different thin film materials on the performance and fabrication of the gauge was studied. The gauges were tested in an arcjet facility. Survivability and accuracy were determined under various hostile environment conditions.

Abtahi, A.↗

Cubic Calorimeter for High-Energy Electrons in Ultra-Long Ballooning

The concept and optimization study of a balloon-borne instrument to study high-energy (from 100 GeV to 5 TeV) cosmic ray electrons will be presented. This energy range of electrons is very interesting for the study of cosmic ray propagation and the search for the nearby sources of high-energy electrons. The instrument is based on a cubic design that allows the detection from all sides. Proton rejection is provided by stringent track analysis, which allows defining when an electron shower is exhausted while the hadron shower continues development. The collecting power of a nominal balloon-borne instrument using this concept will be over 2 square meters sr. This will provide approximately 3,000 electron events above 500 GeV for 3-month long ULDB flight. This instrument will also be capable of detecting sharp features in the high energy gamma-ray spectrum such as gamma-ray lines originating from the dark matter annihilation.

Moiseev, Alexander A.↗

Cosmology, Clusters and Calorimeters

I will review the current state of Cosmology with Clusters and discuss the application of microcalorimeter arrays to this field. With the launch of Astro-E2 this summer and a slew of new missions being developed, microcalorimeters are the next big thing in x-ray astronomy. I will cover the basics and not-so-basic concepts of microcalorimeter designs and look at the future to see where this technology will go.

Figueroa-Feliciano, Enectali↗

Electron Calorimeter Experiment

Boron loaded scintillators are suitable for measuring secondary neutrons produced by high-energy particles: protons & electrons Neutron flux can be used to discriminate hadron and electro-magnetic particles Combined effectiveness of all e/p discriminators techniques employedTBD Only moderate improvement in detection efficiency for B-10 concentrations >few% in thick moderators Bottom scintillator might serve as cascade penetration counter (TBC)

Adams, James H.↗