Isothermal drop calorimeter provides measurements for alpha active, pyrophoric materials

Isothermal drop calorimeter measures the heat content of intensely alpha active and pyrophoric materials in inert atmospheres. It consists of a furnace, calorimeter, and aluminum isothermal jacket contained within an inert-atmosphere glove box, which permits the use of unencapsulated materials without exposing personnel to alpha contamination.

Savage, H.↗

A heat flow calorimeter

Reaction mechanism for nickel-cadmium cell is not known well enough to allow calculation of heat effects. Calorimeter can measure heat absorbed or evolved in cell, by determining amount of external heat that must be supplied to calorimeter to maintain constant flow isothermal heat sink.

Johnston, W. V.↗

Use of thin ionization calorimeters for measurements of cosmic ray energy spectra

The reliability of performing measurements of cosmic ray energy spectra with a thin ionization calorimeter was investigated. Monte Carlo simulations were used to determine whether energy response fluctuations would cause measured spectra to be different from the primary spectra. First, Gaussian distributions were assumed for the calorimeter energy resolutions. The second method employed a detailed Monte Carlo simulation of cascades from an isotropic flux of protons. The results show that as long as the energy resolution does not change significantly with energy, the spectral indices can be reliably determined even for sigma sub e/e = 50%. However, if the energy resolution is strongly energy dependent, the measured spectra do not reproduce the true spectra. Energy resolutions greatly improving with energy result in measured spectra that are too steep, while resolutions getting much worse with energy cause the measured spectra to be too flat.

Jones, W. V.↗

Improvements in a calorimeter for high-power CW lasers

A technique for improving the measurement certainty with the BB series (Smith et al., 1972) of electrically calibrated calorimeters used in high-energy lasers is described. The technique is based on monitoring the energy which is backscattered from the meter and monitoring the overspill radiation impinging on the calorimeter at the entrance aperture. The design and performance of a second generation BB meter is discussed and compared to that of the original device in terms of number of electrical calibrations, the residual standard deviation of electrical calibration, the calibration constant for laser energy, the correcting factor for systematics, inaccuracy, imprecision, and uncertainty.

Chamberlain, G. E.↗

Calorimeter probes for measuring high thermal flux

Expendable, slug-type calorimeter probes were developed for measuring high heat-flux levels of 10-30 kW/sq cm in electric-arc jet facilities. The probes were constructed with thin tungsten caps mounted on Teflon bodies. The temperature of the back surface of the tungsten cap is measured, and its time rate of change gives the steady-state absorbed heat flux as the calorimeter probe heats to destruction when inserted into the arc jet. Design, construction, test, and performance data are presented.

Russell, L. D.↗

Calorimeter probes for measuring high thermal flux

The paper describes expendable, slug-type calorimeter probes developed for measuring high heat-flux levels of 10-30 kW/sq cm in electric-arc jet facilities. The probes are constructed with thin tungsten caps mounted on Teflon bodies; the temperature of the back surface of the tungsten cap is measured, and its rate of change gives the steady-state, absorbed heat flux as the calorimeter probe heats to destruction when inserted into the arc jet. It is concluded that the simple construction of these probes allows them to be expendable and heated to destruction to obtain a measurable temperature slope at high heating rates.

Russell, L. D.↗

Measurement of liquid water content in a melting snowpack using cold calorimeter techniques

Liquid water in a snowpack is a quantifiable parameter of hydrological significance. It is also important in the interpretation of snowpack remote sensing data using microwave techniques. One acceptable approach to measuring liquid water content of a snowpack (by weight) is the cold calorimeter. This technique is presented from theory through application. Silicon oil was used successfully as the freezing agent. Consistent results can be obtained even when using operators with a minimum of training. Data can be obtained approximately every 15 minutes by using two calorimeters and three operators. Accuracy within one to two percent can be achieved under reasonable field conditions.

Rango, A.↗

Comparison of thin-film resistance heat-transfer gages with thin-skin transient calorimeter gages in conventional hypersonic wind tunnels

Thin film gages deposited at the stagnation region of small (8.1-mm-diameter) hemispheres and gages mounted flush with the surface of a sharp-leading-edge flat plate were tested in the Langley continuous-flow hypersonic tunnel and in the Langley hypersonic CF4 tunnel. Two substrate materials were tested, quartz and a machinable glass-ceramic. Small hemispheres were also tested utilizing the thin-skin transient calorimeter technique usually employed in conventional tunnels. One transient calorimeter model was a thin shell of stainless steel, and the other was a thin-skin insert of stainless steel mounted into a hemisphere fabricated from a machinable-glass-ceramic. Measured heat-transfer rates from the various hemispheres were compared with one another and with predicted rates. The results demonstrate the feasibility and advantages of using-film resistance heat-transfer gages in conventional hypersonic wind tunnels over a wide range of conditions.

Miller, C. G., III↗

High-temperature containerless calorimeter

A high-temperature (greater than 1500 K) containerless calorimeter is described and its usefulness demonstrated. The calorimeter uses the technique of omnidirectional electron bombardment of pendant drops to achieve an isothermal test environment. The small heat input into the sample (i.e., 15-50 W) can be controlled and measured. The apparatus can be used to determine the total hemispherical emissivity, specific heat, heat of fusion, surface tension, and equilibrium melting temperature of small molten drops in the temperature range of 1500 to 3500 K. The total hemispherical emissivity and specific heat of pure niobium and two alloys of niobium-germanium have been measured in the temperature range of 1700 to 2400 K. As reported in the literature, the total hemispherical emissivity varied as a function of temperature. However, specific heat values for both the pure metal and alloys seem to be independent of temperature. Specific heat for the liquid alloy phase was also measured and compared to the solid phase.

Robinson, M. B.↗

High-pressure calorimeter chamber tests for liquid oxygen/kerosene (LOX/RP-1) rocket combustion

An experimental program was conducted to investigate the rocket combustion and heat transfer characteristics of liquid oxygen/kerosene (LOX/RP-1) mixtures at high chamber pressures. Two water-cooled calorimeter chambers of different combustion lengths were tested using 37- and 61-element oxidizer-fuel-oxidizer triplet injectors. The tests were conducted at nominal chamber pressures of 4.1, 8.3, and 13.8 MPa abs (600, 1200, and 2000 psia). Heat flux Q/A data were obtained for the entire calorimeter length for oxygen/fuel mixture ratios of 1.8 to 3.3. Test data at 4.1 MPa abs compared favorably with previous test data from another source. Using an injector with a fuel-rich outer zone reduced the throat heat flux by 47 percent with only a 4.5 percent reduction in the characteristic exhaust velocity efficiency C* sub eff. The throat heat transfer coefficient was reduced approximately 40 percent because of carbon deposits on the chamber wall.

Masters, Philip A.↗

Observations of cosmic-ray electrons and positrons using an imaging calorimeter

A ballon-borne magnet spectrometer system was flown for 5.5 hr at an altitude of more than 117,00 feet from Prince Albert, Saskatchewan (Canada), on 1989 September 5, when the Newark neutron monitor rate was 2952. The instrument was a modified version of the one used to observe antiprotons in 1979. The most significant modification was the addition of an imaging calorimeter, 7.33 radiation lengths thick. Inclusion of the calorimeter has significantly improved the ability to distinguish electrons and positrons from the other constituents of the cosmic rays. The absolute electron flux has been determined in the energy interval 1.3-26 GeV. The electron spectrum at the top of the atmosphere was found to be J(sub e-) = 177E(exp -(3.15+/-0.13)) electrons/ sq m/(sr s GeV) in the energy range 4.0-26 GeV. Below 4 GeV, the spectrum showed flattening, which is consistent with the effect of solar modulation. The e(+)/(e(+)+e(-)) ratio was found to be (0.11 +/- 0.03) in the energy range 5.2-13 GeV.

Golden, R. L.↗

Metallized Gelled Propellants: Oxygen/RP-1/Aluminum Rocket Engine Calorimeter Heat Transfer Measurements and Analysis

A set of analyses was conducted to determine the heat transfer characteristics of metallized gelled liquid propellants in a rocket engine. The analyses used the data from experiments conducted with a small 30- to 40-lbf thrust engine composed of a modular injector, igniter, chamber and nozzle. The fuels used were traditional liquid RP-1 and gelled RP-1 with 0-wt %, 5-wt%, and 55-wt% loadings of aluminum with silicon dioxide gellant, and gaseous oxygen as the oxidizer. Heat transfer was computed based on measurements using calorimeter rocket chamber and nozzle hardware with a total of 31 cooling channels. A gelled fuel coating formed in the 0-, 5- and 55-wt% engines, and the coating was composed of unburned gelled fuel and partially combusted RP-1. The coating caused a large decrease in calorimeter engine heat flux in the last half of the chamber for the 0- and 5-wt% RP-1/Al. This heat flux reduction effect was analyzed by comparing engine runs and the changes in the heat flux during a run as well as from run to run. Heat transfer and time-dependent heat flux analyses and interpretations are provided. The 5- and 55-wt% RP-1/Al fueled engines had the highest chamber heat fluxes, with the 5-wt% fuel having the highest throat flux. This result is counter to the predicted result, where the 55 wt% fuel has the highest combustion and throat temperature, and therefore implies that it would deliver the highest throat heat flux. The 5-wt% RP-1/Al produced the most influence on the engine heat transfer and the heat flux reduction was caused by the formation of a gelled propellant layer in the chamber and nozzle.

Palaszewski, Bryan↗

The Scintillating Optical Fiber Calorimeter Instrument Performance (SOFCAL)

SOFCAL is a balloon-borne instrument designed to measure the P-He cosmic ray spectra from about 200 GeV/amu - 20 TeV/amu. SOFCAL uses a thin lead and scintillating-fiber ionization calorimeter to measure the cascades produced by cosmic rays interacting in the hybrid detector system. Above the fiber calorimeter is an emulsion chamber that provides the interaction target, primary particle identification and in-flight energy calibration for the scintillating fiber data. The energy measurement technique and its calibration are described, and the present results from the analysis of a 1 day balloon flight will be presented.

Christl, M. J.↗

Imaging Calorimeter for ACCESS Simulations with GEANT/FLUKA

Imaging Calorimeter for ACCESS (ICA) is a candidate of the calorimeter for the NASA's ACCESS program to be flown on the International Space Station. The ICA studies the origin and acceleration mechanism of cosmic rays by measuring the elemental composition of the cosmic rays in the energy up to 10(exp 16) eV. For the past year, Monte Carlo simulation study for the ICA has been conducted using GEANT/FLUKA to predict the detector performance and to design the system for match the scientific objectives. Simulation results will be shown for the detector response and the energy resolution for various configurations.

Watts, John↗

Charge Detector Study for a Thin Sampling Calorimeter for ACCESS

Advanced Cosmic ray Composition Experiment for Space Station (ACCESS) is a NASA's new mission concept that is now being studied. The scientific objective is to measure cosmic ray elemental energy spectra in the energy range from I TeV up to 1000 TeV. ACCESS will carry two instruments and measure the energy and charge of incoming particles. One of these will be a calorimeter with a charge detector. The charge detector will see not only signals from the incident cosmic rays but also signals from radiation backscattered from the calorimeter. In that case, bias information on particle identification is unavoidable. This study shows how much the charge detector will be affected by backscatter and how it can be designed with a minimized effect.

Lee, Jeongin↗