Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CLEARANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Comparison of Two Alternate Methods for Tracking Toe Clearance

Analyses of toe clearance during the swing phase of locomotion has often been utilized in determining a subject s propensity to trip while either walking or stepping over an obstacle. In the literature, toe clearance has been studied using a marker on the superior aspect of the second toe (rtoe), a marker on the lateral aspect of the fifth metatarsal head (mth5), or a virtual marker positioned at the anterior tip of the toe (vtoe). The purpose of this study was to compute toe clearance and associated parameters using a fifth metatarsal marker and a virtual toe marker, and compare the results with those of the standard toe marker. Subjects walked on a motorized treadmill at five different speeds while performing a visual acuity task at two separate target distances (ten 60-second trials). The minimum vertical height (TCl) was determined for each stride, along with its point of occurence in the gait cycle, and the angles of the foot and ankle at that time. A regression analysis was performed on the vtoe and mth5 results versus rtoe individually. For all TCl parameters, the mth5 marker did not correlate well with rtoe; the vtoe marker showed better agreement. Most importantly, the mth5 marker predicted a later occurence of TCl than rtoe and vtoe - thereby missing the most dangerous point in swing phase for a trip. From this analysis, the vtoe marker proved to be a better analog to rtoe than mth5, especially for determining a subject s propensity to trip.

Miller, Christopher A.↗

Blade tip clearance control apparatus using bellcrank mechanism

A clearance control apparatus has a positioning mechanism for controlling clearance between rotor blade tips and a shroud segment of a gas turbine engine casing. The positioning mechanism is supported by the casing, coupled to the shroud segment, and actuatable for moving the shroud segment toward and away from the rotor blade tips to reach a position at which a desired clearance is established. The mechanism includes a shaft and a bellcrank actuating assembly. The shaft is mounted through a passage defined by a mounting structure on the casing for radial movement along a longitudinal axis of the shaft toward and away from the rotor axis and is coupled at its inner end to the shroud segment. The bellcrank actuating assembly is coupled to an outer end of the shaft and mounted to the casing adjacent the shaft for pivotal movement about an axis spaced from and extending transverse to the longitudinal axis of the shaft. The pivotal movement of the bellcrank actuating assembly produces radial movement of the shaft and shroud segment therewith toward and away from the rotor blade tips.

Corsmeier, Robert J.↗

Automation for "Direct-to" Clearances in Air-Traffic Control

A method of automation, and a system of computer hardware and software to implement the method, have been invented to assist en-route air-traffic controllers in the issuance of clearances to fly directly to specified waypoints or navigation fixes along straight paths that deviate from previously filed flight plans. Such clearances, called "direct-to" clearances, have been in use since before the invention of this method and system.

Erzberger, Heinz↗

Clearance Sensitivity Mitigation in Small Core Compressors

As future aircraft become lighter and more aerodynamically efficient, thrust requirements will decrease, reducing the core size of the engine. Furthermore, in the pursuit of improved fuel burn, engine overall pressure ratio and bypass ratio will increase, further driving down engine core size. These drivers together mean that the core size, or corrected mass flow rate at the compressor exit, for future single-aisle aircraft applications will shrink below 3.0 lbm/s. Traditionally, this small core compressor size is in the domain of axi-centrifugal designs, machines that are typically less efficient and limited to pressure ratios of ~25 due to stress and thermomechanical fatigue in the centrifugal impeller. In this light, NASA, Pratt & Whitney and the Raytheon Technologies Research Center embarked upon a program to develop technologies to enable an all-axial high-pressure compressor with a core size below 3.0 lbm/s and an overall pressure ratio greater than 50. One of the challenges with an all-axial high-pressure compressor at this core size is the small span at the rear of the compressor. As core size is scaled down, the rotor tip clearances do not scale with span, leading to significant efficiency penalties. This paper documents a numerical and experimental effort to mitigate this penalty through design optimization and technology insertion, enabling an estimated 5 to 10% fuel burn reduction relative to 2020 best-in-class. The experimental program consisted of two builds of a high-speed rig: a baseline build and a second build to insert technology to manage large rotor tip gap/span ratios. The results demonstrated a reduction in the sensitivity of the compressor to large clearance ratios, which would be likely at the end-of-life of a small core application. The test campaign demonstrated that, with the insertion of technology, small core compressors can maintain a similar efficiency to current best-in-class large core size compressors. In addition to advancing the state-of-the-art of technology, the program also advanced the modeling standards for multistage compressors with large clearance-to-span ratios. The validation of this approach is described in the paper.

Axial Compressors↗

Clearance Sensitivity Mitigation in Small Core Compressors

As future aircraft become lighter and more aerodynamically efficient, thrust requirements will decrease, reducing the core size of the engine. Furthermore, in the pursuit of improved fuel burn, engine overall pressure ratio and bypass ratio will increase, further driving down engine core size. These drivers together mean that the core size, or corrected mass flow rate at the compressor exit, for future single-aisle aircraft applications will shrink below 3.0 lb/s. Traditionally, this small core compressor size is in the domain of axi-centrifugal designs, machines that are typically less efficient and limited to pressure ratios of ~25 due to stress and thermomechanical fatigue in the centrifugal impeller. In this light, NASA, Pratt & Whitney and the Raytheon Technologies Research Center embarked upon a program to develop technologies to enable an all-axial high-pressure compressor with a core size below 3.0 lb/s and an overall pressure ratio greater than 50. One of the challenges with an all-axial high-pressure compressor at this core size is the small span at the rear of the compressor. As core size is scaled down, the rotor tip clearances do not scale with span, leading to significant efficiency penalties. This paper documents a numerical and experimental effort to mitigate this penalty through design optimization and technology insertion, enabling an estimated 5 to 10% fuel burn reduction relative to 2020 best-in-class. The experimental program consisted of two builds of a high-speed rig: a baseline build and a second build to insert technology to manage large rotor tip gap/span ratios. The results demonstrated a reduction in the sensitivity of the compressor to large clearance ratios, which would be likely at the end-of-life of a small core application. The test campaign demonstrated that, with the insertion of technology, small core compressors can maintain a similar efficiency to current best-in-class large core size compressors. In addition to advancing the state-of-the-art of technology, the program also advanced the modeling standards for multistage compressors with large clearance-to-span ratios. The validation of this approach is described in the paper.

Axial Compressors↗

Measurement Concept for a Possible Clearance of Mercury Waste from Nuclear Facilities - 19138

This paper describes the development of a measurement concept for a clearance of mercury waste from the decommissioning of nuclear facilities. A decontamination of mercury is performed after which large parts of the waste could possibly be released into reuse or conventional mercury disposal. The focus of this work is on the development and validation of a gamma-spectrometric measurement setup that is used for decision-making measurements for a possible clearance procedure. The measurement system is validated by a comparison of experimental measurements with nuclear simulations using Monte Carlo N-Particle{sup R} Transport Code (MCNP{sup R}). The validated MCNP{sup R} simulation model is used to determine the energy-dependent photopeak efficiencies and subsequently the sensitivity of the measurements. Preliminary results of gamma spectrometry in combination with MCNP{sup R} simulations indicate that a clearance of elemental mercury should be possible after decontamination. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nodal Clearance Rate and Long-Term Efficacy of Individualized Sentinel Node–Based Pelvic Intensity Modulated Radiation Therapy for High-Risk Prostate Cancer

Purpose: To assess the efficacy of individual sentinel node (SN)-guided pelvic intensity modulated radiation therapy (IMRT) by determining nodal clearance rate [(n expected nodal involvement − n observed regional recurrences)/n expected nodal involvement] in comparison with surgically staged patients. Methods and Materials: Data on 475 high-risk prostate cancer patients were examined. Sixty-one consecutive patients received pelvic SN-based IMRT (5 × 1.8 Gy/wk to 50.4 Gy [pelvic nodes + individual SN] and an integrated boost with 5 × 2.0 Gy/wk to 70.0 Gy to prostate + [base of] seminal vesicles) and neo-/adjuvant long-term androgen deprivation therapy; 414 patients after SN–pelvic lymph node dissection were used to calculate the expected nodal involvement rate for the radiation therapy sample. Biochemical control and overall survival were estimated for the SN-IMRT patients using the Kaplan-Meier method. The expected frequency of nodal involvement in the radiation therapy group was estimated by imputing frequencies of node-positive patients in the surgical sample to the pattern of Gleason, prostate-specific antigen, and T category in the radiation therapy sample. Results: After a median follow-up of 61 months, 5-year OS after SN-guided IMRT reached 84.4%. Biochemical control according to the Phoenix definition was 73.8%. The nodal clearance rate of SN-IMRT reached 94%. Retrospective follow-up evaluation is the main limitation. Conclusions: Radiation treatment of pelvic nodes individualized by inclusion of SNs is an effective regional treatment modality in high-risk prostate cancer patients. The pattern of relapse indicates that the SN-based target volume concept correctly covers individual pelvic nodes. Thus, this SN-based approach justifies further evaluation, including current dose-escalation strategies to the prostate in a larger prospective series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Arsenic (+ 3 oxidation state) methyltransferase genotype affects steady-state distribution and clearance of arsenic in arsenate-treated mice

Arsenic (+ 3 oxidation state) methyltransferase (As3mt) catalyzes formation of mono-, di-, and tri-methylated metabolites of inorganic arsenic. Distribution and retention of arsenic were compared in adult female As3mt knockout mice and wild-type C57BL/6 mice using a regimen in which mice received daily oral doses of 0.5 mg of arsenic as arsenate per kilogram of body weight. Regardless of genotype, arsenic body burdens attained steady state after 10 daily doses. At steady state, arsenic body burdens in As3mt knockout mice were 16 to 20 times greater than in wild-type mice. During the post dosing clearance period, arsenic body burdens declined in As3mt knockout mice to {approx} 35% and in wild-type mice to {approx} 10% of steady-state levels. Urinary concentration of arsenic was significantly lower in As3mt knockout mice than in wild-type mice. At steady state, As3mt knockout mice had significantly higher fractions of the body burden of arsenic in liver, kidney, and urinary bladder than did wild-type mice. These organs and lung had significantly higher arsenic concentrations than did corresponding organs from wild-type mice. Inorganic arsenic was the predominant species in tissues of As3mt knockout mice; tissues from wild-type mice contained mixtures of inorganic arsenic and its methylated metabolites. Diminished capacity for arsenic methylation in As3mt knockout mice prolongs retention of inorganic arsenic in tissues and affects whole body clearance of arsenic. Altered retention and tissue tropism of arsenic in As3mt knockout mice could affect the toxic or carcinogenic effects associated with exposure to this metalloid or its methylated metabolites.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Resveratrol protects the ovary against chromium-toxicity by enhancing endogenous antioxidant enzymes and inhibiting metabolic clearance of estradiol

Resveratrol (RVT), a polyphenolic component in grapes and red wine, has been known for its cytoprotective actions against several diseases. However, beneficial effects of RVT against early exposure to endocrine disrupting chemicals (EDCs) have not been understood. EDCs are linked to several ovarian diseases such as premature ovarian failure, polycystic ovary syndrome, early menopause and infertility in women. Hexavalent chromium (CrVI) is a heavy metal EDC, and widely used in > 50 industries. Environmental contamination with CrVI in the US is rapidly increasing, predisposing the human to several illnesses including cancers and still birth. Our lab has been involved in determining the molecular mechanism of CrVI-induced female infertility and intervention strategies to mitigate CrVI effects. Lactating mother rats were exposed to CrVI (50 ppm potassium dichromate) from postpartum days 1–21 through drinking water with or without RVT (10 mg/kg body wt., through oral gavage daily). During this time, F1 females received respective treatments through mother's milk. On postnatal day (PND) 25, blood and the ovary, kidney and liver were collected from the F1 females for analyses. CrVI increased atresia of follicles by increasing cytochrome C and cleaved caspase-3; decreasing antiapoptotic proteins; decreasing estradiol (E{sub 2}) biosynthesis and enhancing metabolic clearance of E{sub 2}, increasing oxidative stress and decreasing endogenous antioxidants. RVT mitigated the effects of CrVI by upregulating cell survival proteins and AOXs; and restored E{sub 2} levels by inhibiting hydroxylation, glucuronidation and sulphation of E{sub 2}. This is the first study to report the protective effects of RVT against any toxicant in the ovary. - Highlights: • Resveratrol (RVT) protects the ovary against CrVI-toxicity. • RVT mitigated CrVI-induced apoptosis and follicle atresia. • RVT restored estradiol level against CrVI-toxicity. • RVT inhibited metabolic clearance of estradiol in the ovary, kidney and liver. • RVT mitigated CrVI toxicity by upregulating cell survival proteins and antioxidants.

60 APPLIED LIFE SCIENCES↗

The effect of angiotensin receptor neprilysin inhibitor, sacubitril/valsartan, on central nervous system amyloid-β concentrations and clearance in the cynomolgus monkey

Sacubitril/valsartan (LCZ696) is the first angiotensin receptor neprilysin inhibitor approved to reduce cardiovascular mortality and hospitalization in patients with heart failure with reduced ejection fraction. As neprilysin (NEP) is one of several enzymes known to degrade amyloid-β (Aβ), there is a theoretical risk of Aβ accumulation following long-term NEP inhibition. The primary objective of this study was to evaluate the potential effects of sacubitril/valsartan on central nervous system clearance of Aβ isoforms in cynomolgus monkeys using the sensitive Stable Isotope Labeling Kinetics (SILK™)-Aβ methodology. The in vitro selectivity of valsartan, sacubitril, and its active metabolite sacubitrilat was established; sacubitrilat did not inhibit other human Aβ-degrading metalloproteases. In a 2-week study, sacubitril/valsartan (50 mg/kg/day) or vehicle was orally administered to female cynomolgus monkeys in conjunction with SILK™-Aβ. Despite low cerebrospinal fluid (CSF) and brain penetration, CSF exposure to sacubitril was sufficient to inhibit NEP and resulted in an increase in the elimination half-life of Aβ1-42 (65.3%; p = 0.026), Aβ1-40 (35.2%; p = 0.04) and Aβtotal (29.8%; p = 0.04) acutely; this returned to normal as expected with repeated dosing for 15 days. CSF concentrations of newly generated Aβ (AUC{sub (0–24} {sub h)}) indicated elevations in the more aggregable form Aβ1-42 on day 1 (20.4%; p = 0.039) and day 15 (34.7%; p = 0.0003) and in shorter forms Aβ1-40 (23.4%; p = 0.009), Aβ1-38 (64.1%; p = 0.0001) and Aβtotal (50.45%; p = 0.00002) on day 15. However, there were no elevations in any Aβ isoforms in the brains of these monkeys on day 16. In a second study cynomolgus monkeys were administered sacubitril/valsartan (300 mg/kg) or vehicle control for 39 weeks; no microscopic brain changes or Aβ deposition, as assessed by immunohistochemical staining, were present. Further clinical studies are planned to address the relevance of these findings. - Highlights: • Sacubitril/valsartan reduced Aβ clearance on day 1, but not after 15 daily doses. • Sacubitril/valsartan increased CSF Aβ but did not result in increases in brain Aβ. • No Aβ brain pathology in 39 week monkey study with high dose sacubitril/valsartan.

60 APPLIED LIFE SCIENCES↗

Blade tip clearance measurement of the turbine engines based on a multi-mode fiber coupled laser ranging system

The blade tip clearance is a parameter of great importance to guarantee the efficiency and safety of the turbine engines. In this article, a laser ranging system designed for blade tip clearance measurement is presented. Multi-mode fiber is utilized for optical transmission to guarantee that enough optical power is received by the sensor probe. The model of the tiny sensor probe is presented. The error brought by the optical path difference of different modes of the fiber is estimated and the length of the fiber is limited to reduce this error. The measurement range in which the optical power received by the probe remains essentially unchanged is analyzed. Calibration experiments and dynamic experiments are conducted. The results of the calibration experiments indicate that the resolution of the system is about 0.02 mm and the range of the system is about 9 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-242: Design of a Novel Afterloader Clearance QA Device for Biliary HDR Therapy

Purpose: Bile duct cancer affects 2–3 thousand people annually in the United States. Radiation therapy has been shown to double median survival, with combined external beam and intraluminal high dose-rate (HDR) brachytherapy being most effective. Endoscopic retrograde cholangiopancreatography (ERCP) biliary HDR, a less-invasive alternative to trans-hepatic brachytherapy, is delivered through a catheter that travels a tortuous path from nose to bile duct, requiring wire drive force and dexterity beyond typical afterloader performance specifications. Thus, specific afterloader quality assurance(QA) is recommended for this procedure. Our aim was to create a device and process for Varisource afterloader clearance QA with objectives that it be quantitative and can monitor afterloader performance over time, compare performance between two distinct afterloaders and potentially Result in a predictive nomogram for patient-specific clearance. Methods: Based on retrospective reconstruction of 20 ERCP patient anatomies, we designed a phantom to test afterloader ability to drive the source wire along an intended treatment path. The ability of the afterloader to fully extend the intended treatment path is a function of number and diameters of turns. We have determined experimentally that relative position of the turns does not impact performance. Results: Both patient and QA paths involve three common turns/loops: a large turn representing the stomach(10.8cm±2.0cm), an elliptical loop representing the duodenum(7.3cm±1.5cmx4.8cm±0.7cm), and a final turn at the end of the bile duct that may be tight for some patient-specific anatomies and absent in others(3.7cm±0.7cm, where present). Our phantom design uses anatomical average turn diameters for the stomach and duodenum then terminates in a turn of quantitatively selectable diameter. The smallest final turn diameter that an afterloader can pass is recorded as the QA parameter. Conclusion: With this device and QA process, we have the ability to quantitatively evaluate and track our afterloader performance for a technically challenging ERCP brachytherapy procedure.

60 APPLIED LIFE SCIENCES↗

Modeling suggests SARS-CoV-2 rebound after nirmatrelvir-ritonavir treatment is driven by target cell preservation coupled with incomplete viral clearance

In a subset of SARS-CoV-2-infected individuals treated with the antiviral nirmatrelvir-ritonavir, the virus rebounds following treatment. The mechanisms driving this rebound are not well understood. We used a mathematical model to describe the longitudinal viral load dynamics of 51 individuals treated with nirmatrelvir-ritonavir, 20 of whom rebounded. Target cell preservation, either by a robust innate immune response or initiation of N-R near the time of symptom onset, coupled with incomplete viral clearance, appears to be the main factor leading to viral rebound. Moreover, the occurrence of viral rebound is likely influenced by the time of treatment initiation relative to the progression of the infection, with earlier treatments leading to a higher chance of rebound. A comparison with an untreated cohort suggests that early treatments with nirmatrelvir-ritonavir may be associated with a delay in the onset of an adaptive immune response. Nevertheless, our model demonstrates that extending the course of nirmatrelvir-ritonavir treatment to a 10-day regimen may greatly diminish the chance of rebound in people with mild-to-moderate COVID-19 and who are at high risk of progression to severe disease. Altogether, our results suggest that in some individuals, a standard 5-day course of nirmatrelvir-ritonavir starting around the time of symptom onset may not completely eliminate the virus. Thus, after treatment ends, the virus can rebound if an effective adaptive immune response has not fully developed. These findings on the role of target cell preservation and incomplete viral clearance also offer a possible explanation for viral rebounds following other antiviral treatments for SARS-CoV-2.

60 APPLIED LIFE SCIENCES↗

TiO{sub 2} nanorods branched on fast-synthesized large clearance TiO{sub 2} nanotube arrays for dye-sensitized solar cells

A large clearance TiO{sub 2} nanotube arrays (LTAs) has been synthesized by a not more than 12 h anodization duration and based on this a branched TiO{sub 2} nanotube arrays (BLTs) has been achieved through TiO{sub 2} nanorods branch-like grown on the LTAs. Some key factors and probable mechanisms of the fabrication processes on two novel nanoarchitectures are discussed. Exhilaratingly, it is found that the obtained LTAs has demonstrated large pore diameter and void spaces (pore diameter {approx}350 nm; void spaces {approx}160 nm; and tube length {approx}3.5 {mu}m), and the synthesized hierarchical BLTs, compared with conventional TiO{sub 2} nanotube arrays, has shown a much stronger dye absorption performance and an approximately double of the solar cell efficiency (in our case from 1.62% to 3.18% under simulated AM 1.5 conditions). - Graphical Abstract: The schematic diagram of synthesis process for LTAs and BLTs is on the above and the corresponding FESEM images of obtained photoanodes samples are shown below. Highlights: > Large clearance TiO{sub 2} nanotube arrays (LTAs) was synthesized by a fast anodization process of 12 h. > Anodization time of 12 h is just 10% of about 120 h reported in the previous references. > Branch-like TiO{sub 2} nanotube arrays (BLTs) was achieved by growing TiO{sub 2} nanorods on the LTAs. > Obtained BLTs and LTAs show impressive morphology and noticeable improvement of surface area. > BLTs shows about more than 1 times higher solar cell efficiency than that of TiO{sub 2} nanotube arrays.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Testing and Performance Validation of a Shielded Waste Segregation and Clearance Monitor Designed for the Measurement of Low Level Waste-13043

This paper describes the development, testing and validation of a shielded waste segregation and clearance monitor designed for the measurement of low-density low-level waste (LLW). The monitor is made of a measurement chamber surrounded by detectors and a shielded outer frame. The shielded chamber consists of a steel frame, which contains typically 1.5 inches (3.81 cm) of lead and 0.5 inches (1.27 cm) of steel shielding. Inside the shielding are plastic scintillator panels, which serve as gross gamma ray detectors. The detector panels, with embedded photomultipliers, completely surround the internal measurement chamber on all 6 sides. Care has been taken to distribute the plastic scintillator detectors in order to optimise both the efficiency for gamma ray detection and at the same time achieve a volumetric sensitivity, which is as uniform as possible. A common high voltage power supply provides the bias voltage for each of the six photomultipliers. The voltage signals arising from the detectors and photomultipliers are amplified by six sensitive amplifiers. Each amplifier incorporates a single channel analyser with both upper and lower thresholds and the digitised counts from each detector are recorded on six scalars. Operation of the device is by means of a microprocessor from which the scalars are controlled. An internal load cell linked to the microprocessor determines the weight of the waste object, and this information is used to calculate the specific activity of the waste. The monitor makes background measurements when the shielded door is closed and a sample, usually a bag of low-density waste, is not present in the measurement chamber. Measurements of the minimum detectable activity (MDA) of an earlier large volume prototype instrument are reported as part of the development of the Waste Segregation and Clearance Monitor (WSCM) described in the paper. For the optimised WSCM a detection efficiency of greater than 32% was measured using a small Cs-137 source placed in the centre of the measurement chamber. Small sources have also been used to determine the spatial variation of the detection efficiency for various positions within the measurement chamber. The data have been used to establish sentencing limits and different 'fingerprints' for specific waste streams including waste streams containing fission products and others based on other radionuclides including Am-241. Some of the test data that are presented have been used to validate the instrument performance. The monitor is currently in routine use at a nuclear facility for the measurement and sentencing of low-density low activity radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Future Liver Remnant Indocyanine Green Plasma Clearance Rate as a Predictor of Post-hepatectomy Liver Failure After Portal Vein Embolization

PurposeTo evaluate the utility of future liver remnant plasma clearance rate of indocyanine green (ICGK-F) for predicting post-hepatectomy liver failure (PHLF) compared with percentage future liver remnant volume-to-total liver volume ratio (%FLR) after portal vein embolization (PVE).Materials and MethodsPVE procedures in 20 patients (15 patients underwent PVE with absolute ethanol; 5 patients with gelatin particles) from 2010 to 2017 were analyzed. %FLR = future liver remnant volume (ml)/[total liver volume (ml) − tumor volume (ml)] × 100; ICGK-F = plasma clearance rate of indocyanine green (ICGK) × %FLR/100 were calculated before and after PVE. PHLF was categorized according to the criteria of the International Study Group of Liver Surgery. For predicting PHLF, we compared the ICGK-F and %FLR after PVE between the grade A PHLF group and the non-grade A PHLF (grades B and C) group.ResultsAll PVE procedures were successful. While the ICGK-F of the grade A PHLF group (median 0.073, n = 16) was about twice that of the non-grade A PHLF group (median 0.043, n = 4), showing a significant difference (Mann–Whitney U test: P = 0.002), there was no significant difference in %FLR between the grade A PHLF group and the non-grade A PHLF group (Mann–Whitney U test: P = 0.335).ConclusionICGK-F was significantly higher in the grade A PHLF group than in the non-grade A PHLF group (grades B and C), and ICGK-F was more useful for predicting PHLF than %FLR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clearance rates of freshwater bivalves Corbicula fluminea and Utterbackia imbecillis in the presence and absence of light

Light affects bivalve behavior and gaping activity, but its potential effects on bivalve filtration remain poorly investigated. In this paper, clearance rates of two bivalve species: the Asian clam, Corbicula fluminea and the paper pondshell, Utterbackia imbecillis, were assessed in light (6.5 ± 0.5 µmol m -2 s -1 ) and dark (0.0 µmol m -2 s -1 ) conditions. We found that clearance rates remained similar between C. fluminea (50 ± 18 mL g -1 h -1 ) and U. imbecillis (41 ± 10 mL g -1 h -1 ) during light conditions. However, C. fluminea (110 ± 15 mL g -1 h -1 ) filtered significantly faster than U. imbecillis (24 ± 6 mL g -1 h -1 ) in the dark condition (p < 0.05). The results indicated that light might affect the filtration activity in freshwater bivalves differently, depending on species.

59 BASIC BIOLOGICAL SCIENCES↗