Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CID”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A compact dication source for Ba 2+ tagging and heavy metal ion sensor development

Here, we present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cadmium samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean Ba 2+ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb 2+ and Cd 2+ also demonstrated for this purpose.

47 OTHER INSTRUMENTATION↗

Dark Energy Survey Year 3 results: Simulation-based cosmological inference with wavelet harmonics, scattering transforms, and moments of weak lensing mass maps. II. cosmological results

Here, we present a simulation-based cosmological analysis using a combination of Gaussian and non-Gaussian statistics of the weak lensing mass (convergence) maps from the first three years of the Dark Energy Survey. We implement the following: (1) second and third moments; (2) wavelet phase harmonics; (3) the scattering transform. Our analysis is fully based on simulations, spans a space of seven 𝑤 Cold Dark Matter (𝑤⁢ CDM) cosmological parameters, and forward models the most relevant sources of systematics inherent in the data: masks, noise variations, clustering of the sources, intrinsic alignments, and shear and redshift calibration. We implement a neural network compression of the summary statistics, and we estimate the parameter posteriors using a simulation-based inference approach. Including and combining different non-Gaussian statistics is a powerful tool that strongly improves constraints over Gaussian statistics (in our case, the second moments); in particular, the figure of merit (𝑆 8 , Ω m ) is improved by 70% (Λ ⁢CDM) and 90% (𝑤 ⁢CDM). When all the summary statistics are combined, we achieve a 2% constraint on the amplitude of fluctuations parameter 𝑆 8 ≡ 𝜎 8 ⁢(Ω m /0.3) 0.5 , obtaining 𝑆 8 = 0.794 ±0.017 (Λ⁢ CDM) and 𝑆 8 = 0.817 ±0.021 (𝑤 ⁢CDM), and a ∼10% constraint on Ω m , obtaining Ω m =0.259 ±0.025 (Λ ⁢CDM) and Ω m = 0.273 ±0.029 (𝑤⁢ CDM). In the context of the 𝑤⁢ CDM scenario, these statistics also strengthen the constraints on the parameter 𝑤, obtaining 𝑤 <−0.72. The constraints from different statistics are shown to be internally consistent (with a 𝑝-value>0.1 for all combinations of statistics examined). We compare our results to other weak lensing results from the first three years of the Dark Energy Survey data, finding good consistency; we also compare with results from external datasets, such as planck constraints from the cosmic microwave background, finding statistical agreement, with discrepancies no greater than <2.2⁢𝜎.

79 ASTRONOMY AND ASTROPHYSICS↗

Electroluminescence Yield Measurements in Xenon Gas with the NEXT-DEMO++ Detector

The NEXT-DEMO++ detector, a high-pressure xenon gas time projection chamber serving as a prototype for the NEXT-100 experiment, was used to measure the electroluminescence (EL) yield as a function of reduced electric field ($E/p$) across pressures from 2.0 to 9.4 bar, utilizing the 41.5 keV de-excitation peak of $^{83m}$Kr. These measurements were made to examine the pressure dependence of the slope of the reduced EL yield $Y/p$, which has shown inconsistencies in the literature. The reduced yield was fitted with a linear model, revealing a modest ($\sim$5%) change in slope, beginning around 5 bar and increasing with pressure up to 9.4 bar.

Renner, J. [Valencia U., IFIC]↗

Detection of scintillation light in noble gases with wavelength-shifting optical fibers

Wavelength-shifting (WLS) techniques enable particle detectors based on noble gases, whose scintillation light is predominantly emitted in the vacuum-ultraviolet. We investigate WLS fibers coated with tetraphenyl butadiene (TPB) for scintillation light detection in gaseous xenon and argon at pressures up to 8.5 bar, motivated by future high-pressure xenon time-projection chambers of the NEXT program. Two detector configurations are studied: an elongated high-pressure vessel with four PTFE panels equipped with WLS fibers read by temperature-stabilized SiPMs, and a compact box-shaped detector operated at 1 bar Xe with WLS fibers read out by PMTs. Both operate with continuous gas purification. The detector response is characterized using cosmic muons and alpha particles from a $^{241}$Am source. With the SiPM setup, we measure a light collection efficiency (LCE) of ${1.18 \pm 0.01~\mathrm{(sta.)}~^{+0.07}_{-0.09}~\mathrm{(sys.)}~\%}$ for xenon and ${1.07 \pm 0.01~\mathrm{(sta.)}~^{+0.06}_{-0.08}~\mathrm{(sys.)}~\%}$ for argon. With PMT readout, we measure a LCE of ${0.45 \pm 0.01~\mathrm{(sta.)} \pm 0.05~\mathrm{(sys.)}~\%}$ in xenon, in agreement with the SiPM result once photon detection efficiency is accounted for. Average scintillation waveforms in xenon and argon are studied to assess the time structure of the emitted light. Cosmic-muon measurements yield a mean energy required to produce a scintillation photon $45\pm7~\mathrm{(sta.)}~^{+4}_{-5}~\mathrm{(sys.)}~\mathrm{eV}$ at 1.5 bar, in agreement with the literature. The results demonstrate that TPB-coated WLS fiber systems can reliably detect scintillation light in high-pressure gaseous noble detectors, with a LCE representing an upper limit for realistic large-scale TPCs, where additional photon losses from materials and fiber attenuation are expected.

Soleti, S. R. [Donostia Intl. Phys. Ctr., San Seba↗

Investigation of Uranyl Perchlorate Anion Complexes in the Gas Phase via Infrared Multiphoton Dissociation and Collision‐Induced Dissociation

The infrared multiphoton dissociation spectrum of the gas-phase uranyl perchlorate anion ([UO 2 (ClO 4 ) 3 ] − ) was measured. Here, the asymmetric uranyl stretch lies somewhere between 930 and 1030 cm −1 , though it could not be deconvoluted from a closely located perchlorate stretching mode. The experimentally measured spectrum was in good agreement with spectra calculated using density functional theory with the B3LYP and TPSSh functionals and Grimme's D3 dispersion corrections with Becke–Johnson damping. The calculations suggest that the asymmetric uranyl stretch lies in the range of 970–980 cm −1 , about 20–30 cm −1 higher than for the analogous uranyl trinitrato complex and consistent with perchlorate as a weaker ligand than nitrate. Like the uranyl trinitrato anion, fragmentation of [UO 2 (ClO 4 ) 3 ] − by collision-induced dissociation resulted in loss of a ClO 3 • radical to form [UO 3 (ClO 4 ) 2 ] − . Infrared multiphoton dissociation measurements of [UO 3 (ClO 4 ) 2 ] − indicate that the structure of the product ion has an O − ligand bound to the uranyl in a T-arrangement and two perchlorate ligands, matching the findings from uranyl nitrato complexes. The uranyl stretch in this complex was slightly separated from the perchlorate modes and was measured at 906 cm −1 , slightly higher than for the analogous nitrate complex, again consistent with perchlorate as a weaker ligand than nitrate in the gas phase.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging

If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $\overline{cos θ}$ and $\overline{T_1}$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of neutrinoless double beta decay searches in gaseous xenon with NEXT

The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in 136 Xe, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this technology, operated in the Laboratorio Subterráneo de Canfranc. Achieving an energy resolution of 1% FWHM at 2.6 MeV and further background rejection by means of the topology of the reconstructed tracks, NEXT-White has been exploited beyond its original goals in order to perform a neu- trinoless double beta decay search. The analysis considers the combination of 271.6 days of 136 Xe-enriched data and 208.9 days of 136Xe-depleted data. A detailed background modeling and measurement has been developed, ensuring the time stability of the radiogenic and cosmogenic contributions across both data samples. Limits to the neutrinoless mode are obtained in two alternative analyses: a background-model-dependent approach and a novel direct background-subtraction technique, offering results with small dependence on the background model assumptions. With a fiducial mass of only 3.50 ± 0.01 kg of 136 Xe-enriched xenon, 90% C.L. lower limits to the neutrinoless double beta decay are found in the $T^{0v}_{1/2} > 5.5 \times 10^{23} - 1.3 \times 10^{24}$ yr range, depending on the method. The presented techniques stand as a proof-of-concept for the searches to be implemented with larger NEXT detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of energy resolution with the NEXT-White silicon photomultipliers

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses $^{83m}$Kr data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9 ± 0.6)%, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs.[graphic not available: see fulltext]

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diverse events have transferred genes for edible seaweed digestion from marine to human gut bacteria

Humans harbor numerous species of colonic bacteria that digest fiber polysaccharides in commonly consumed terrestrial plants. More recently in history, regional populations have consumed edible macroalgae seaweeds containing unique polysaccharides. It remains unclear how extensively gut bacteria have adapted to digest these nutrients. Here, in this work, we show that the ability of gut bacteria to digest seaweed polysaccharides is more pervasive than previously appreciated. Enrichment-cultured Bacteroides harbor previously discovered genes for seaweed degradation, which have mobilized into several members of this genus. Additionally, other examples of marine bacteria-derived genes, and their mobile DNA elements, are involved in gut microbial degradation of seaweed polysaccharides, including genes in gut-resident Firmicutes. Collectively, these results uncover multiple separate events that have mobilized the genes encoding seaweed-degrading-enzymes into gut bacteria. This work further underscores the metabolic plasticity of the human gut microbiome and global exchange of genes in the context of dietary selective pressures.

42 ENGINEERING↗

OzDES Reverberation Mapping of Active Galactic Nuclei: Final Data Release, Black-Hole Mass Results, & Scaling Relations

Over the last decade, the Australian Dark Energy (OzDES) collaboration has used Reverberation Mapping to measure the masses of high redshift supermassive black holes. Here we present the final review and analysis of this OzDES reverberation mapping campaign. These observations use 6-7 years of photometric and spectroscopic observations of 735 Active Galactic Nuclei (AGN) in the redshift range 0.13-3.85 and bolometric luminosity range 44.3 - 47.5 erg/s. Both photometry and spectra are observed in visible wavelengths, allowing for the physical scale of the AGN broad line region to be estimated from reverberations of the H{̱e̱ṯa̱}̱, MgII and CIV emission lines. We successfully use reverberation mapping to constrain the masses of 62 super-massive black holes, and combine with existing data to fit a power law to the lag-luminosity relation for the H{̱e̱ṯa̱}̱ and MgII lines with a scatter of ~0.25 dex, the tightest yet identified, fit specifically for consistency with high redshift AGN. We fit a similarly constrained relation for CIV, resolving a tension with the low luminosity literature AGN by accounting for selection effects arising from finite survey length. We also examine the impact of emission line width and luminosity (related to accretion rate) in reducing the scatter of these scaling relationships and find no significant improvement over the lag-only approach for any of the three lines. Using these relations, we further estimate the masses and accretion rates of 246 AGN with single epoch methods. We also use these relations to estimate the relative sizes of the H{̱e̱ṯa̱}̱, MgII and CIV emitting regions. In short, we provide a comprehensive benchmark of high redshift AGN reverberation mapping at the close of this most recent generation of surveys, including light curves, time-delays, and a set of significantly improved radius-luminosity relations for use with high-redshift populations.

McDougall, Hugh [Queensland U.]↗

A Dual-Gated Structures for Lossless Ion Manipulations-Ion Mobility Orbitrap Mass Spectrometry Platform for Combined Ultra-High-Resolution Molecular Analysis

High-resolution ion mobility spectrometry-mass spectrometry (HR-IMS-MS) instruments have enormously advanced the ability to characterize complex biological mixtures. Unfortunately, HR-IMS and HR-MS measurements are typically performed independently due to mismatches in analysis time scales. Here we overcome this limitation by using a dual-gated ion injection approach to couple an 11-meter path length structures for lossless ion manipulations (SLIM) module to a Q-Exactive Plus Orbitrap MS. The dual-gate setup was implemented by placing one ion gate before the SLIM module and a second ion gate after. The dual-gated ion injection approach allowed the new SLIM-Orbitrap platform to simultaneously perform an 11-meter SLIM separation, Orbitrap mass analysis using the highest selectable mass resolution setting (up to 140k), and high-energy collision induced dissociation (HCD) in ~25 minutes over an $m/z$ range of ~1500 amu. The SLIM-Orbitrap was initially characterized using a mixture of standard phosphazene cations and demonstrated an average SLIM CCS resolving power (Rp CCS ) of ~218 and SLIM peak capacity of ~156 while simultaneously obtaining high mass resolutions. SLIM-Orbitrap analysis with fragmentation was then performed on mixtures of standard peptides and two reverse peptides (SDGRG 1+ , GRGDS 1+ , Rp CCS = 305) to demonstrate the utility of combined HR-IMS-MS/MS measurements for peptide identification. Our new HR-IMS-MS/MS capability was further demonstrated by analyzing a complex lipid mixture and showcasing SLIM separations on isobaric lipids. In conclusion, this new SLIM-Orbitrap platform demonstrates a critical new capability for proteomics and lipidomics applications, and the high-resolution multimodal data obtainable with this system establishes the foundation for reference-free identification of unknown ion structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TMTpro Complementary Ion Quantification Increases Plexing and Sensitivity for Accurate Multiplexed Proteomics at the MS2 Level

Multiplexed proteomics is a powerful tool to assay cell states in health and disease, but accurate quantification of relative protein changes is impaired by interference from co-isolated peptides. Most widely, this issue is alleviated by MS3-based quantification, reducing sensitivity and requiring specialized instrumentation. An alternative approach is quantification by complementary ions, which allows accurate and precise multiplexed quantification at the MS2 level and is compatible with the most widely distributed instruments. However, complementary ions of the popular TMT tag form inefficiently and plexing is limited to five channels. In this work, we evaluate and optimize complementary ion quantification for the recently released TMTPro tag, which increases plexing capacity to 8 channels (TMTProC). We find that the beneficial fragmentation properties increase quantification signal five-fold compared to TMT. This increased sensitivity results in ~50% more proteins quantified compared to TMTPro-MS3 and even slightly outperforms TMTPro-MS2. Furthermore, TMTProC quantification is more accurate than TMTPro-MS2 and even superior to TMTPro-MS3. To demonstrate the power of TMTProC, we analyzed a human and yeast interference sample and were able to quantify 13,290 proteins in 24 fractions. Thus, TMTProC advances multiplexed proteomics data quality and widens access to accurate multiplexed proteomics beyond laboratories with MS3-capable instrumentation.

59 BASIC BIOLOGICAL SCIENCES↗

Exploring Fluoropyridine Electrolytes in Li–S Batteries: Balancing Performance and Stability across Temperatures

A novel high-donor 3-fluoropyridine (3FPy) electrolyte has been introduced for use in Li-S batteries, demonstrating an inhibition effect on the polysulfide shuttle, even without the addition of LiNO 3 . In this study, fluoropyridine electrolytes, including 2-fluoropyridine (2FPy) and 3FPy electrolytes, are studied using electrochemical analysis, mass spectrometry (MS), and high-performance liquid chromatography (HPLC) methods. Collision-induced dissociation spectra revealed that Li + preferentially solvates with different fluoropyridines, with 2FPy exhibiting a stronger interaction due to ortho-fluorine's influence, compared to 4FPy and 3FPy. However, MS and HPLC analyses showed that 2FPy is reactive with polysulfides, while 3FPy offers high solubility for polysulfides and sulfur without reacting with them at room temperature. Further, despite 3FPy performing well at room temperature, further electrochemistry studies at elevated (60 °C) and reduced (0 °C) temperatures reveal the challenges. At high temperatures, LiNO 3 is essential to suppress the polysulfide shuttle; and at low temperatures, the performance with the 3FPy electrolyte significantly lags behind that of the ether-based electrolyte.

25 ENERGY STORAGE↗