Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building Dataset”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

SWS Building Electric Demand Profile

This dataset contains data on the electric use of the building in 15-minute increments (kilowatt-hours and average kilowatts).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Generative Adversarial Network based Autoencoder: Application to fault detection problem for closed loop dynamical systems

Fault detection problem for closed loop uncertain dynamical systems, is investigated in this paper, using different deep learning based methods. Traditional classifier based method does not perform well, because of the inherent difficulty of detecting system level faults for closed loop dynamical system. Specifically, acting controller in any closed loop dynamical system, works to reduce the effect of system level faults. A novel Generative Adversarial based deep Autoencoder is designed to classify datasets under normal and faulty operating conditions. This proposed network performs significantly well when compared to any available classifier based methods, and moreover, does not require labeled fault incorporated datasets for training purpose. Finally, this aforementioned network's performance is tested on a high complexity building energy system dataset.

deep learning, Active fault detection↗

Buildings Sector Scenarios: Demand-side data to support energy system planning in the United States

The US energy system is in a period of high uncertainty about load growth, its implications for the energy generation mix, and downstream impacts on customer energy costs. In this context, there is a need for comprehensive, credible, and readily-customized projections of energy demand to ensure that planning decisions account for end-use management opportunities to improve system reliability and affordability. Here we introduce the Buildings Sector Scenarios (BSS) dataset, which includes a benchmark suite of such projections for the buildings sector — a key source of energy consumption, peak electricity demand, and consumer energy expenditures. The dataset contains projections through 2050 covering the contiguous United States (CONUS) resolved down to the county, hourly level by sector and end use for electricity demand and to the state, annual level by sector and end use for non-electric fuels. We summarize the BSS analysis workflow and the tools and datasets that support it, document key BSS scenario inputs and modeling assumptions, and outline BSS scenario outputs. We assess the technical quality of the dataset against historical surveys and projected estimates of buildings sector demand. Finally, we provide guidance on how stakeholders can access, use, and reproduce the dataset, and/or create new scenarios to explore their own analysis questions.

Langevin, Jared↗

Electric load shape benchmarking for small- and medium-sized commercial buildings

Small- and medium-sized commercial buildings owners and utility managers often look for opportunities for energy cost savings through energy efficiency and energy waste minimization. However, they currently lack easy access to low-cost tools that help interpret the massive amount of data needed to improve understanding of their energy use behaviors. Benchmarking is one of the techniques used in energy audits to identify which buildings are priorities for an energy analysis. Traditional energy performance indicators, such as the energy use intensity (annual energy per unit of floor area), consider only the total annual energy consumption, lacking consideration of the fluctuation of energy use behavior over time, which reveals the time of use information and represents distinct energy use behaviors during different time spans. To fill the gap, this study developed a general statistical method using 24-hour electric load shape benchmarking to compare a building or business/tenant space against peers. Specifically, the study developed new forms of benchmarking metrics and data analysis methods to infer the energy performance of a building based on its load shape. We first performed a data experiment with collected smart meter data using over 2,000 small- and medium-sized businesses in California. We then conducted a cluster analysis of the source data, and determined and interpreted the load shape features and parameters with peer group analysis. Finally, we implemented the load shape benchmarking feature in an open-access web-based toolkit (the Commercial Building Energy Saver) to provide straightforward and practical recommendations to users. The analysis techniques were generic and flexible for future datasets of other building types and in other utility territories.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Accuracy of automated measurement and verification (M&V) techniques for energy savings in commercial buildings

Trustworthy savings calculations are critical to convincing investors in energy efficiency projects of the benefit and cost-effectiveness of such investments and their ability to replace or defer supply-side capital investments. However, today’s methods for measurement and verification (M&V) of energy savings constitute a significant portion of the total costs of efficiency projects. They also require time-consuming manual data acquisition and often do not deliver results until years after the program period has ended. The rising availability of “smart” meters, combined with new analytical approaches to quantifying savings, has opened the door to conducting M&V more quickly and at lower cost, with comparable or improved accuracy. These meter- and software-based approaches, increasingly referred to as “M&V 2.0”, are the subject of surging industry interest, particularly in the context of utility energy efficiency programs. Program administrators, evaluators, and regulators are asking how M&V 2.0 compares with more traditional methods, how proprietary software can be transparently performance tested, how these techniques can be integrated into the next generation of whole-building focused efficiency programs. This paper expands recent analyses of public-domain whole-building M&V methods, focusing on more novel M&V2.0 modeling approaches that are used in commercial technologies, as well as approaches that are documented in the literature, and/or developed by the academic building research community. We present a testing procedure and metrics to assess the performance of whole-building M&V methods. We then illustrate the test procedure by evaluating the accuracy of ten baseline energy use models, against measured data from a large dataset of 537 buildings. The results of this study show that the already available advanced interval data baseline models hold great promise for scaling the adoption of building measured savings calculations using Advanced Metering Infrastructure (AMI) data. Median coefficient of variation of the root mean squared error (CV(RMSE)) was less than 25% for every model tested when twelve months of training data were used. With even six months of training data, median CV(RMSE) for daily energy total was under 25% for all models tested. Finally, these findings can be used to build confidence in model robustness, and the readiness of these approaches for industry uptake and adoption

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Conditional distribution estimation of building characteristics with diffusion models for urban energy modeling

Understanding current energy consumption behavior in communities is critical for informing future energy use decisions and enabling efficient energy management. Urban energy models, which are used to simulate these energy use patterns, require large datasets with detailed building characteristics for accurate outcomes. However, such detailed characteristics at the individual building level are often unknown and costly to acquire, or unavailable. Through this work, we propose using a generative modeling approach to generate realistic building attributes to fill in the data gaps and finally provide complete characteristics as inputs to energy models. Our model learns complex, building-level patterns from training on a large-scale residential building stock model containing 2.2 million buildings. We employ a tabular diffusion-based framework that is designed to handle heterogeneous (discrete and continuous) features in tabular building data, such as occupancy, floor area, heating, cooling, and other equipment details. We develop a capability for conditional diffusion, enabling the imputation of missing building characteristics conditioned on known attributes. We conduct a comprehensive validation of our conditional diffusion model, firstly by comparing the generated conditional distributions against the underlying data distribution, and secondly, by performing a case study for a Baltimore residential region, showing the practical utility of our approach. Our work is one of the first to demonstrate the potential of generative modeling to accelerate building energy modeling workflows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing simulated demand flexibility against actual performance in commercial office buildings

Commercial building energy benchmarking has been used as a mechanism to evaluate energy use of a single building over time, relative to other similar buildings, or to simulations of a reference building conforming to various energy standards. Lack of empirical demand flexibility data and consistent flexibility metrics has limited the ability to compare demand flexibility performance with estimated demand flexibility in buildings. In this study, we collected demand response performance data for a total of 831 demand response events from 192 sites as a first step to build such a building demand flexibility dataset, and propose a standard core data schema to consolidate field data from different sources. We also performed parametric simulations of a control strategy called “global temperature adjustment” using commercial office prototype building models. We then compared the simulated demand flexibility performance against the actual data for offices with global temperature adjustment strategy implemented. During demand response events with an average outside air temperature of 34 °C (range 23 °C–42 °C), the measured demand decrease intensity of the demand flexibility metrics were 6.1 watts per square meter (W/m 2 ), 10.0 W/m 2 , 11.1 W/m 2 , 7.1 W/m 2 , and 4.7 W/m 2 for small, small–medium, medium, medium–large, and large office buildings, respectively. Compared to the measured data in medium- and large-size buildings, the simulated demand decrease intensity was 0.7 W/m 2 (17%) lower on average. The discrepancy between simulated and measured peak demand intensities fell within one standard deviation of the mean measured data. Here, the comparison results validate the credibility of simulations in capturing real building data for assessing the technical potential of building demand flexibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling City Building Stock for Large-Scale Energy Efficiency Improvements using CityBES

Buildings in San Francisco consumed 52% of total primary energy. Improving building energy efficiency is one of the key strategies cities are adopting towards their energy and climate goals. Urban building energy models (UBEM) can support city managers to evaluate and prioritize energy conservation measures for investment and to design effective incentive and rebate programs. This paper introduces methods to develop a standardized dataset of city building stock, and it demonstrates the use of a UBEM tool, City Building Energy Saver (CityBES), for an urban-scale energy retrofit analysis of building stock in the city of San Francisco. CityBES is an open web-based data and computing platform providing city-scale building energy modeling and performance visualization and benchmarking. CityBES utilizes an international standard CityGML to represent the three-dimensional building stock in cities. As an application example, 940 office and retail buildings in six districts of northeast San Francisco were modeled and analyzed with CityBES to evaluate energy savings for five selected measures. The analysis found that replacing existing lighting with LED and adding an air economizer to HVAC systems are cost-effective measures with combined savings per building between 17% to 31%. The CityBES retrofit analysis feature does not require users to have deep knowledge of building systems or building energy models, which helps overcome barriers for city managers and their consultants to adopt UBEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sharing is caring: An extensive analysis of parameter-based transfer learning for the prediction of building thermal dynamics

In recent years deep neural networks have been proposed as a lightweight data-driven model to capture high-dimensional, nonlinear physical processes to predict building thermal responses. However, the need of a large amount of data for the training process of deep neural networks clashes with the potential limited data availability in most existing or new buildings. Transfer learning aims to enhance the performance of a target learner exploiting knowledge from related and similar environments. This study conducted a suite of experiments that leveraged 250 data-driven models based on a synthetic dataset of a building archetype to study the influence of data availability, energy efficiency level, occupancy and climate for the transfer process of thermal dynamics. The performance of the transfer learning process was compared against a classical machine learning approach. Here, the results suggest that building thermal dynamics can be effectively transferred under the same climatic conditions, increasing performance when dealing with different occupancy schedules, efficiency levels and low data availability. Furthermore, the paper compares the performance of both transfer learning and machine learning approaches in an online fashion, to support the implementation in real-world deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Datasets of Faults in Variable Air Volume Terminal Units in a Multi-Zone Commercial Building

Faults in HVAC systems can decrease system efficiency and equipment lifespan, leading to 5%–30% of energy consumption being wasted in commercial buildings. We identified two common faults in HVAC variable air volume systems: a stuck damper fault in the variable air volume terminal unit and a discharge airflow sensor fault. We conducted three sets of damper stuck tests and two sets of airflow sensor tests, each including a fault-free scenario and scenarios with varying levels of faults, over one day. The faults were implemented in Oak Ridge National Laboratory’s two-story Flexible Research Platform building to generate a high-quality, well-controlled dataset covering fault-induced and fault-free scenarios. The test building, fault test scenarios, and data validation are described here. The open-source dataset includes 1 min intervals of weather and building data on the presence and absence of building faults. This dataset can be used to analyze the effects of HVAC system faults on system operation and indoor building conditions, and to develop or evaluate a fault detection and diagnosis algorithm.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

WearGP: A computationally efficient machine learning framework for local erosive wear predictions via nodal Gaussian processes

Computational fluid dynamics (CFD)-based wear predictions are computationally expensive to evaluate, even with a high-performance computing infrastructure. Thus, it is difficult to provide accurate local wear predictions in a timely manner. Data-driven approaches provide a more computationally efficient way to approximate the CFD wear predictions without running the actual CFD wear models. In this paper, a machine learning (ML) approach, termed WearGP, is presented to approximate the 3D local wear predictions, using numerical wear predictions from steady-state CFD simulations as training and testing datasets. The proposed framework is built on Gaussian process (GP) and utilized to predict wear in a much shorter time. The WearGP framework can be segmented into three stages. At the first stage, the training dataset is built by using a number of CFD simulations in the order of O (10 2 ). At the second stage, the data cleansing and data mining process are performed, where the nodal wear solutions are extracted from the solution database to build a training dataset. At the third stage, the wear predictions are made, using trained GP processes. Two CFD case studies including 3D slurry pump impeller and casing are used to demonstrate the WearGP framework, in which 144 training and 40 testing data points are used to train and test the proposed method, respectively. The numerical accuracy, computational effiency and effectiveness between the WearGP framework and CFD wear model for both slurry pump impellers and casings are compared. It is shown that the WearGP framework can achieve highly accurate results that are comparable with the CFD results, with a relatively small size training dataset, with a computational time reduction in an order of 10 5 to 10 6 .

42 ENGINEERING↗

Development of a metamodelling framework for building energy models with application to fifth-generation district heating and cooling networks

Fully defined physics-based building energy models can accurately represent building systems; however, generating models based on high-level parameters is time consuming and simulation time of complex models can be slow. This article discusses the development of a Metamodelling Framework to create metamodels from a building energy modelling dataset. The framework generates metamodels using either linear regression, random forests, or support vector regressions. A fifth-generation district heating and cooling system analysis use case was used to motivate the development of the framework. The use case required quick and accurate representations of annual building loads reported hourly. Typical annual building modelling approaches can result in a runtime of 10 min. The metamodels runtime was reduced to less than 10 s to load and run an annual simulation with user-defined covariates. The results of the metamodel performance and an abbreviated topology analysis based on the motivating use case will be presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dataset for Biorefinery-specific feedstock price variability, Part 1: Corn stover

This dataset was utilized in a report to highlight parameters that affect near-term sustainable supply of corn stover and forest resources at $56 and $74 per dry ton delivered. While the report focus is restricted to 2018, the modeling runs are available from 2016-2022. In the 2016 Billion-ton Report (BT16), two stover cases were presented. In this dataset, we vary technical levels of those assumptions to measure stover supply response and to evaluate the major determinants of stover supply. In each of these cases, the supply is modeled first at the farmgate at prices up to $80 per dry ton for five deterministic scenarios. Building on this dataset, a supplementary dataset of delivered supply was modeled for 800k dry ton per year capacity facilities in two facility siting approaches. Results were summarized across delivered supply curves for twelve scenarios. The resulting supply curves are highly elastic, resulting in a range of potential supplies across scenarios at specified prices. Interactive visualization of these data allows exploration into any specified nth plant supply sensitivity to key variables and spatial distribution of stover resources. The analysis is economic supply risk and doesn’t account for disruptions from competing demands, namely livestock feed and bedding markets. Scenario ending in _BC3080 is a reference scenario consistent with BT16 Basecase (BC1), but with corn stover price isolation. Scenario ending in _OHB080 includes high operational efficiency constraints for corn stover. Scenario ending in _OLB080 includes low operational efficiency constraints for corn stover. Scenario ending in _PLB080 includes low opportunity cost. Scenario ending in _PHB080 includes high opportunity cost. No Land Rental costs are applied to these scenarios. All scenarios were under an exogenous price simulation using POLYSYS (v2017).

Agricultural residues, biomass resources, 2018, bi↗

Data Sets for Evaluation of Building Fault Detection and Diagnostics Algorithms

This documentation and dataset can be used to test the performance of automated fault detection and diagnostics algorithms for buildings. The dataset was created by LBNL, PNNL, NREL, ORNL and ASHRAE RP-1312 (Drexel University). It includes data for air-handling units and rooftop units simulated with PNNL's large office building model.

AHU↗

A Comprehensive Comparison of Building Height Products at a Global Level

The built environment continues to expand due to increasing human populations with some projections indicating additional growth of 2.5 billion persons by 2050. Buildings are a key component of the built environment and information on building height and urban morphology in general can help to better understand and address a host of development and urban planning issues including energy consumption, urbanization, population dynamics, urban heat islands, environmental degradation, and others. To date, several approaches have been developed to address the need for mapping building height at scale. These approaches can be grouped into two main categories: 1) directly measure height from remote sensing products or 2) indirectly estimate height from footprint morphology features at the building-by-building level. Due to a number of these global height datasets now being available for consumption and use across domains, there is a critical need to understand the differences displayed between these products and how the use of these may influence the outcome when applied. In this analysis, we compare and evaluate 5 global building height datasets: Global Human Settlement, World Settlement Footprint 3D, Global Building Morphology dataset, three-dimensional Global Building Footprints, and an approach developed at Oak Ridge National Laboratory (ORNL). Our analysis shows that, across 5 cities at a global scale with high-quality building height reference data, the approach developed by ORNL of inferring height at the building-by-building level is more accurate and consistent. This was evidenced by the ORNL product improving upon the baseline in all 5 cities, the only product to do so. These findings will aid researchers in choosing a global building height product that best meets their needs and provides global availability, consistency, and accuracy.

42 ENGINEERING↗

Model America

Data set including 17 fields of information for 141,506,665 U.S. buildings. Advantages of this dataset include: Resolution - actionable data and models for individual U.S. buildings; Flexibility - ability to modify data, models, and analysis for any simulation-informed use case; Scalability - dynamic archetypes can be used as representative models for any geography of interest; Accuracy - error rates for total energy use at city-scale of 1-5%

New, JoshuaR↗

Data-driven Thermal Model Inference with ARMAX, in Smart Environments, based on Normalized Mutual Information

Understanding the models that characterize the thermal dynamics in a smart building is important for the comfort of its occupants and for its energy optimization. Here, a significant amount of research has attempted to utilize thermodynamics (physical) models for smart building control, but these approaches remain challenging due to the stochastic nature of the intermittent environmental disturbances. This paper presents a novel data-driven approach for indoor thermal model inference, which combines an Autoregressive Moving Average with eXogenous inputs model (ARMAX) with a Normalized Mutual Information scheme (NMI). Based on this information-theoretic method, NMI, causal dependencies between the indoor temperature and exogenous inputs are explicitly obtained as a guideline for the ARMAX model to find the dominating inputs. For validation, we use three datasets based on building energy systems-against which we compare our method to an autoregressive model with exogenous inputs (ARX), a regularized ARMAX model, and state-space models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗