Retail Operations to Reduce Risks of Airborne Infectious Disease Transmission
A fact sheet of best practices and guidelines around HVAC, exhaust systems, BAS, elevators, and space use for retail operators.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A fact sheet of best practices and guidelines around HVAC, exhaust systems, BAS, elevators, and space use for retail operators.
This fact sheet examines best practices and guidelines around HVAC, exhaust systems, BAS, elevators, and space use for hotel/motel operators.
A fact sheet of best practices and guidelines around HVAC, exhaust systems, BAS, elevators, and space use for hotel/motel operators.
Significant resources have been invested in making buildings “smart” by digitizing, networking and automating key systems and operations. Smart autonomous buildings create new energy efficiency, economic and environmental opportunities. But as buildings become increasingly networked to the Internet, they can also become more vulnerable to various cyber threats. Automated and Internet-connected buildings systems, equipment, controls, and sensors can significantly increase cyber and physical vulnerabilities that threaten the confidentiality, integrity, and availability of critical systems in organizations. Securing smart autonomous buildings presents a national security and economic challenge to the nation. Ignoring this challenge threatens business continuity and the availability of critical infrastructures that are enabled by smart buildings. In this chapter, the authors address challenges and explore new opportunities in securing smart buildings that are enhanced by machine learning, cognitive sensing, artificial intelligence (AI) and smart-energy technologies. The chapter begins by identifying cyber-threats and challenges to smart autonomous buildings. Then it provides recommendations on how AI enabled solutions can help smart buildings and facilities better protect, detect and respond to cyber-physical threats and vulnerabilities. Next, the chapter will provide case studies that examine how combining AI with innovative smart-energy technologies can increase both cybersecurity and energy efficiency savings in buildings. The chapter will conclude by proposing recommendations for future cybersecurity and energy optimization research for examining AI enabled smart-energy technology.
Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.
The goal of this project is to develop Mortar.io, an open-source BAS platform designed to simplify data collection, archiving, event scheduling and coordination of cross-system interactions. Mortar.io is optimized for (1) robustness to network outages, (2) ease of installation using plug-and-play and (3) scalable support for small to large buildings and campuses.
For this study, lighting system control data from five patient rooms in a neonatal intensive care unit (NICU) over a 25-week monitoring period were analyzed to better understand how the NICU staff and families interacted with an automatic tunable lighting system (variable spectrum and intensity) with manual override options. The data were analyzed to determine the amount of time spent in available lighting modes, estimate energy consumption, and to observe any patterns in how the lighting system was being used by occupants. Further analysis revealed opportunities for optimizing the system for occupant needs and energy savings. The patient room occupants were clearly engaged in using the lighting system throughout the 24-hour day to meet needs and preferences. Giving occupants control over the lighting system did not result in a considerable increase in energy use. Implementing a time-out would minimize the extended periods of time when the lights were left on without need at the highest brightness level, further decreasing energy use. This analysis reveals the potential of lighting control data to contribute to energy savings.
Modern buildings are increasingly automated and often equipped with multiple building services (e.g., air-conditioning and mechanical ventilation (ACMV), dynamic shading, dimmable lighting). These systems are conventionally controlled individually without considering their interactions, affecting the building’s overall energy inefficiency and occupant comfort. A model predictive control (MPC) system that features a multi-objective MPC scheme to enable coordinated control of multiple building services for overall optimized energy efficiency, indoor thermal and visual comfort, as well as a hybrid model for predicting indoor visual comfort and lighting power is proposed. The MPC system was implemented in a test facility having two identical, side-by-side experimental cells to facilitate comparison with a building management system (BMS) employing conventional reactive feedback control. The MPC system coordinated the control of the ACMV, dynamic façade and automated dimmable lighting systems in one cell while the BMS controlled the building services in the other cell in a conventional manner. The MPC side achieved 15.1–20.7% electricity consumption reduction, as compared to the BMS side. Simultaneously, the MPC system improved indoor thermal comfort by maintaining the room within the comfortable range (-0.5 < predicted mean vote < 0.5) for 98.3% of the time, up from 91.8% of the time on the BMS side. Visual comfort, measured by indoor daylight glare probability (DGP) and horizontal illuminance level at work plane height, was maintained for the entire test period on the MPC side, improving from having visual comfort for 94.5% and 85.7% of the time, respectively, on the BMS side.
In this study, the Brick ontology is a unified semantic metadata standard for building assets and their relationships, serving as a key enabler for effective interoperability and automation of building systems and analytics. However, creating a Brick model, in other words, standard semantic metadata based on the Brick ontology for a building dataset, can be a complex task. This paper presents two case studies of the creation of Brick models for real-world residential and commercial building datasets, highlighting the challenges during the Brick model creation process. Additionally, the paper introduces VizBrick, an interactive authoring tool for creating semantic building metadata. VizBrick facilitates the creation of Brick models by providing an intuitive visual interface and interactive capabilities, such as keyword search, automatic mapping suggestions, and recommendations. The use of VizBrick is shown to significantly reduce the time and effort required during the Brick model creation process.
Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.
To support and accelerate the development of simulation protocols in atomistic modelling, we introduce an integrated development environment (IDE) for computational materials science called pyiron (http://pyiron.org). The pyiron IDE combines a web based source code editor, a job management system for build automation, and a hierarchical data management solution. The core components of the pyiron IDE are pyiron objects based on an abstract class, which links application structures such as atomistic structures, projects, jobs, simulation protocols and computing resources with persistent storage and an interactive user environment. The simulation protocols within the pyiron IDE are constructed using the Python programming language. To highlight key concepts of this tool as well as to demonstrate its ability to simplify the implementation and testing of simulation protocols we discuss two applications. In these examples we show how pyiron supports the whole life cycle of a typical simulation, seamlessly combines ab initio with empirical potential calculations, and how complex feedback loops can be implemented. While originally developed with focus on ab initio thermodynamics simulations, the concepts and implementation of pyiron are general thus allowing to employ it for a wide range of simulation topics.
Developers of real-time embedded software often need to build the operating system, kernel, tools and supporting applications from source to work with the differences in their hardware configuration. The first attempts to introduce Linux-based real-time embedded systems into the Fermilab accelerator controls system used this approach but it was found to be time-consuming, difficult to maintain and difficult to adapt to different hardware configurations. Buildroot is an open source build system with a menu-driven configuration tool (similar to the Linux kernel build system) that automates this process. A customized Buildroot [1] system has been developed for use in the Fermilab accelerator controls system that includes several hardware configuration profiles (including Intel, ARM and PowerPC) and packages for Fermilab support software. A bootable image file is produced containing the Linux kernel, shell and supporting software suite that varies from 3 to 20 megabytes large – ideal for network booting. The result is a platform that is easier to maintain and deploy in diverse hardware configurations
This fact sheet describes a grid-interactive efficient building technology that is undergoing field validation tests through DOE's National Labs. It summarizes the technology application (MelRok's Energy IOT Touch), the parameters of the demonstration, and the characteristics of the field validation site.
This fact sheet describes a grid-interactive efficient building technology that is undergoing field validation tests through DOE's National Labs. It summarizes the technology application (Synapse software from Kinetic Buildings) and the characteristics of the field validation site.
The U.S. General Services Administration's (GSA's) Green Proving Ground (GPG) program, in partnership with the National Laboratory of the Rockies (NLR), completed a field study of a Grid-Interactive Efficient Buildings (GEB) software solution. The study focused on a single testbed facility to test the GEB functionality of the software solution, along with other features. The testbed facility - a courthouse - is a common building type in GSA's vast building portfolio, offering potentially impactful findings on a scalable level. The study evaluated Prescriptive Data's technology, Nantum OS, a connected building operating system ("GEB Solution") which aggregates multiple sources of previously siloed building data and combines that data with external sources, such as weather information or utility signals, into a single integrated platform. A GEB Solution is a type of Energy Management Information System (EMIS). EMIS is defined as a system of devices, data services, and software applications that communicates with any building system or third-party data source to aggregate and transform data into new capabilities to aid in the optimization of energy use at the building, campus, or agency level. This specific GEB Solution is an EMIS with ASO, automated system optimization, offering supervisory control of certain aspects of the Building Automation System (BAS). Multiple features were evaluated including, but not limited to, Continuous Demand Management to avoid setting new monthly kilowatt (kW) peaks, energy efficiency for reduction of kilowatt hours (kWh) and natural gas consumption, and automated demand response (ADR) for purposes of lowering demand during a utility called Demand Response (DR) event. The testbed facility was the Foley Federal Building and US Courthouse ("Foley Federal Building") located in Las Vegas, NV. This is a 209,496 sq. ft. building constructed in the 1960s with major renovations in 2004. The facility was a good candidate due to the large prevalence of office and courthouse spaces in the GSA portfolio of buildings. It also has many features which allow integration into and control of the building and a strong facilities team to assist with the study. Quantitative and qualitative performance objectives were developed using GSA's GPG GEB project template along with input from the vendor and building facility staff; these are outlined in Table 1. The quantitative performance objectives focused on continuous demand management, energy efficiency, and automated demand response. The qualitative performance objectives focused on the ease of installation and commissioning as well as the operability of the GEB solution. Other performance metrics that are reported on include carbon reduction, cost effectiveness, and occupant acceptance.
The U.S General Services Administration's (GSA's) Green Proving Ground program, in partnership with the National Renewable Energy Laboratory. completed a large pilot study of an Energy Management Information Systems (EMIS) with Automated System Optimization (ASO). Four test bed facilities, each with different building characteristics and systems, were chosen for the implementation of cloud-based EMIS with ASO. Depending on functionality, this tool can be extremely effective in energy management and energy optimization in buildings. The capabilities evaluated in the pilot ranged from energy savings and energy consumption predictions to evaluations of user acceptance, operability, and ease of installation. This report presents the methodology, lessons learned and best practices, and deployment recommendations for the GSA's portfolio of commercial office space, comprising more than 8,500 properties.
Energy systems are increasingly complicated by the proliferation of clean energy technologies such as solar, wind, storage, electric vehicles, and building automations. Future energy systems will require secure, autonomous, and reliable communications, control, and interoperability among millions of distributed generation points and billions of buildings, vehicles, and more. To enable effective management of the anticipated growth of distributed devices and the deluge of data and extensive metering that will follow, the National Renewable Energy Laboratory (NREL) has developed the concept of autonomous energy systems (AES).
Energy management information systems (EMIS) are a broad and rapidly evolving family of tools that monitor, analyze, and control building energy use and system performance. Critical systems are often integrated with or operate on the same networks as EMIS scope systems, necessitating stable, continuous, and secure communication. When connecting EMIS to building automation and utility control systems, there are also many physical assets that could cause harm to the building and its occupants if a malicious act or human error were introduced. It is imperative to ensure all EMIS scope systems are connected securely to the EMIS and do not open vulnerable pathways to other facility networks and operations. The Federal Energy Management Program (FEMP) promotes best practices for impactful utilization of EMIS at federal facilities. This best practice document is part of a series of fact sheets created to help accelerate the market adoption and use of EMIS in the federal sector. It provides an overview of required EMIS cybersecurity standards for compliance and authority to operate along with additional recommendations.